Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The 20 kW battery study program

Six battery configurations were selected for detailed study and these are described. A computer program was modified for use in estimation of the weights, costs, and reliabilities of each of the configurations, as a function of several important independent variables, such as system voltage, battery voltage ratio (battery voltage/bus voltage), and the number of parallel units into which each of the components of the power subsystem was divided. The computer program was used to develop the relationship between the independent variables alone and in combination, and the dependent variables: weight, cost, and availability. Parametric data, including power loss curves, are given.

Source record↗

Practical considerations for Abel inverting of photographic data with application to the analysis of a 15-kW wall-stabilized arc-light source

Temperature profiles were measured for agron atmospheric pressure by using absolute line and continuum intensity and were compared with stark width and shift measurements. A detailed analysis of the engineering aspects of setting up for Abel inverting deta photographically is presented. The merits of using photographic detection and of using continuum radiation for temperature profile analysis are discussed. The importance of empirically determining the optical depth is emphasized by discrepancies between measured (two-path) and calculated estimates.

Snow, W. L.↗

Experimental determination of the vibration level in 5,100 kW electric locomotive assemblies

Because of the high vibration level occurring during the running of electric locomotives, mechanical defects occur in the control mechanisms of auxiliary services. This fact has given rise to the necessity of determining the values of these vibrations in electric locomotives during their running. Measurements were conducted on the Craiova-Drobeta-Turnu Severin line, and measures to reduce the vibration level in electric locomotives were instituted.

Criciotoiu, E.↗

A 2.5 kW advanced technology ion thruster

A program has been conducted in order to improve the performance characteristics of 30 cm thrusters. This program was divided into three distinct, but related tasks: (1) the discharge chamber and component design modifications proposed for inclusion in the engineering model thruster were evaluated and engineering specifications were verified; (2) thrust losses which result from the contributions of double charged ions and nonaxial ion trajectories to the ion beam current were measured and (3) the specification and verification of power processor and control requirements of the engineering model thruster design were demonstrated. Proven design modifications which provide improved efficiencies are incorporated into the engineering model thruster during a structural re-design without introducing additional delay in schedule or new risks. In addition, a considerable amount of data is generated on the relation of double ion production and beam divergence to thruster parameters. Overall thruster efficiency is increased from 68% to 71% at full power, including corrections for double ion and beam divergence thrust losses.

Poeschel, R. L.↗

NaK-nitrogen liquid metal MHD converter tests at 30 kw

The feasibility of electrical power generation with an ambient temperature liquid-metal MHD separator cycle is demonstrated by tests in which a NaK-nitrogen LM-MHD converter was operated at nozzle inlet pressures ranging from 100 to 165 N/sq cm, NaK flow rates from 46 to 72 kg/sec, and nitrogen flow rates from 2.4 to 3.8 kg/sec. The generator was operated as an eight-phase linear induction generator, with two of the eight phases providing magnetic field compensation to minimized electrical end losses at the generator channel inlet and exit.

Cerini, D. J.↗

The aerodynamic design of a compressor-drive turbine for use in a 75 kw automotive engine

The design of a single stage axial-flow turbine with a tip diameter of 11.15 cm is presented. The design specifications are given, and the aerodynamic design procedure is described. The aerodynamic information includes the results of flow path, velocity diagram, and blade profile studies. Predicted off-design performance characteristics are also presented.

Roelke, R. J.↗

Aerodynamic design of a free power turbine for a 75 KW gas turbine automotive engine

A single stage axial-flow turbine having a tip diameter of 15.41 centimeters was designed. The design specifications are given and the aerodynamic design procedure is described. The design includes the transition duct and the turbine exit diffuser. The aerodynamic information includes typical results of a parametric study, velocity diagrams, blade surface and wall velocities, and blade profile and wall coordinates.

Kofskey, M. G.↗

The 7.5 kW solar array simulator

A high power solar array simulator capable of providing the input power to simultaneously operate two 30 cm diameter ion thruster power processors was designed, fabricated, and tested. The maximum power point is set to between 150 and 7500 watts representing an open circuit voltage from 50 to 300 volts and a short circuit current from 4 to 36 amps. Illuminated solar cells are used as the control element to provide a true solar cell characteristic and permit the option of simulating changes in this characteristic due to variations in solar intensity and/or temperature of the solar array. This is accomplished by changing the illumination and/or temperature of the control cells. The response of the output to a step change in load closely approximates that of an actual solar array.

Robson, R. R.↗

7.5 kW solar array simulator

A high power solar array simulator capable of providing the input power to simultaneously operate two 30 cm diameter ion thruster power processors was designed, fabricated, and tested. The maximum power point may be set to between 150 and 7500 watts. This represents an open circuit voltage from 50 to 300 volts and a short circuit current from 4 to 36 amps. Illuminated solar cells are used as the control element. The illuminated solar cells provide a true solar cell characteristic and permit the option of simulating changes in this characteristic due to variations in solar intensity and/or temperature of the solar array. This is accomplished by changing the illumination and/or temperature of the control cells. The response of the output to a step change in load closely approximates that of an actual solar array.

Robson, R. R.↗

Research study on multi-KW DC distribution system

Power distribution system noise and transient stress on switchgear in large space vehicle power systems were investigated in terms of the effect of flight designs of long power distribution cables on load interface EMI requirements. A fifty meter cable pair was simulated to study interactions between the cable, load, and power source terminations. Power system noise characteristics were evaluated based on current spacecraft data, interface hardware filter designs, and power cable parameters. Parametric approaches were defined for evaluating switching transients at various distribution voltage levels. It is concluded that the state-of-the-art semiconductor switches represent a viable approach toward the implementation of power system design with distribution voltages of 120 VDC or less. The interface definition and design for the bus control unit was updated to be consistent with the established requirements.

Berkery, E. A.↗

Free vibrations of the ERDA-NASA 100 kW wind turbine

The ERDA-NASA wind turbine (windmill), which consists of a 93-foot truss tower, a bed plate that supports mechanical and electrical equipment, and two 62.5-foot long blades, was analyzed to determine its free vibrations using NASTRAN. The finite element representation of the system consisted of beam and plate elements. The free vibrations of the tower alone, the blades alone, and the complete system were determined experimentally in the field. These results were obtained by instrumenting the tower or blades with an accelerometer and impacting the components with an instrumented mass. The predicted results for natural frequencies and mode shapes were in excellent agreement with measured data.

Chamis, C. C.↗

The 2.5 kW advanced technology ion thruster

A representative thruster was extensively documented with respect to performance parameters and characteristics at selected ion beam currents in the 0.5 to 2.75 A range, including measurements of thrust losses resulting from doubly-charged ions and ion beam divergence. Corrected total efficiency was shown to be relatively insensitive to operating parameter selection at any given power level. Factors affecting doubly-charged ionization were studied and it was found that the fraction of doubly-charged ions is directly proportional to the discharge chamber propellant utilization. The parameter that most affects this proportionality is the accel aperture diameter (which controls neutral atom loss). Thruster-power conditioner interactions were studied with the result that previous power supply specifications remain satisfactory. Options for reducing the number of power supplies required were demonstrated to be feasible. Gimbal actuator designs were studied with the goal of selecting a particular approach for design and development. The conclusion drawn was that optimum gimbal actuator design depends heavily on the thruster application and consequently the effort was concluded by developing a computer program to aid in specifying the gimbal requirements for the thrust vectoring required in a specific application.

Poeschel, R. L.↗

100-kW hingeless metal wind turbine blade design, analysis and fabrication

The design, fabrication and analysis of aluminum wind turbine rotor blades is discussed. The blades are designed to meet criteria established for a 100-kilowatt wind turbine generator operating between 8 and 60-mile-per-hour speeds at 40 revolutions per minute. The design wind speed is 18 miles per hour. Two rotor blades are used on a new facility which includes a hingeless hub and its shaft, gearbox, generator and tower. Experience shows that, for stopped rotors, safe wind speeds are strongly dependent on blade torsional and bending rigidities which the basic D spar structural blade design provides. The 0.25-inch-thick nose skin is brake/bump formed to provide the basic 'D' spar structure for the tapered, twisted blades. Adequate margins for flutter and divergence are predicted from the use of existing, correlated stopped rotor and helicopter rotor analysis programs.

Donham, R. E.↗

Free vibrations of the ERDA-NASA 100 kW wind turbine

The ERDA-NASA wind turbine (windmill), which consists of a 93-foot truss tower, a bed plate that supports mechanical and electrical equipment, and two 62.5-foot long blades, was analyzed to determine its free vibrations using NASTRAN. The finite element representation of the system consisted of beam and plate elements. The free vibrations of the tower alone, the blades alone, and the complete system were determined experimentally in the field. These results were obtained by instrumenting the tower or blades with an accelerometer and impacting the components with an instrumented mass. The predicted results for natural frequencies and mode shapes were in excellent agreement with measured data.

Chamis, C. C.↗

Wind tunnel measurements of the tower shadow on models of the ERDA/NASA 100 KW wind turbine tower

Detailed wind speed profile measurements were made in the wake of 1/25 scale and 1/48 scale tower models to determine the magnitude of the speed reduction (the tower shadow). The 1/25 scale tower modeled closely the actual wind turbine including the service stairway and the equipment elevator rails on one face. The 1/48 scale model was made of all tubular members. Measurements were made on the 1/25 scale model with and without the stairway and elevator rails, and on the 1/48 all tube model without stairs and rails. The test results show that the stairs and rails were a major source of wind flow blockage. The all tubular 1/48 scale tower was found to offer less resistance to the wind than the 1/25 scale model that contained a large number of square sections. Shadow photos are included to show the extent of the blockage offered to the wind from various directions.

Savino, J. M.↗

High-power and 2.5 kW advanced-technology ion thruster

Investigations for improving ion thruster components in the 30 cm engineering model thruster (EMT) resulted in the demonstration of useful techniques for grid short removal and discharge chamber erosion monitoring, establishment of relationships between double ion production and thruster operating parameters, verification of satisfactory specifications on porous tungsten vaporizer material and barium impregnated porous tungsten inserts, demonstration of a new hollow cathode configuration, and specification of magnetic circuit requirements for reproducing desired magnetic mappings. The capacity of a 30 cm EMT to operate at higher beam voltages and currents (higher power) was determined. Operation at 2 A beam current and higher beam voltage is shown to be essentially equivalent to operation at 1.1 kV with regard to efficiency, lifetime and operating conditions. The only additional requirement is an improvement in high voltage insulation and propellant isolator capacity. Operation at minimum voltage and higher beam currents is shown to increase thruster discharge chamber erosion in proportion to beam current. Studies to find alternatives to molybdenum for manufacturing ion optics grids are also reported.

Poeschel, R. L.↗

Design and operating experience on the US Department of Energy experimental Mod-0 100-kW wind turbine

The experimental wind turbine was designed and fabricated to assess technology requirements and engineering problems of large wind turbines. The machine has demonstrated successful operation in all of its design modes and served as a prototype developmental test bed for the Mod-0A operational wind turbines which are currently used on utility networks. The mechanical and control system are described as they evolved in operational tests and some of the experience with various systems in the downwind rotor configurations are elaborated.

Glasgow, J. C.↗