Status of CHIP-TRAP: The Central Michigan University High-Precision Penning Trap

Precise and accurate atomic mass data provide crucial information for applications in a wide range of fields in physics and beyond, including astrophysics, nuclear structure, particle and neutrino physics, fundamental symmetries, chemistry, and metrology. The most precise atomic mass measurements are performed on charged particles confined in a Penning trap. Here, we describe the development, status, and outlook of CHIP-TRAP: the Central Michigan University high-precision Penning trap. CHIP-TRAP aims to perform ultra-high precision (~1 part in 10 11 fractional precision) mass measurements on stable and long-lived isotopes produced with external ion sources and transported to the Penning traps. Along the way, ions of a particular m/q are selected with a multi-reflection time-of-flight mass separator (MR-TOF-MS), with further filtering performed in a cylindrical capture trap before the ions are transported to a pair of hyperbolic measurement traps. In this paper, we report on the design and status of CHIP-TRAP and present results from the commissioning of the ion sources, MR-TOF-MS, and capture trap. We also provide an outlook on the continued development and commissioning of CHIP-TRAP.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Processing iridium foil targets for the production of radioplatinum isotopes

Dissolving noble metals remains challenging because of their high reduction potentials and tendency to passivate as oxides. This barrier is acute for iridium metal targets used to produce platinum radioisotopes, where post-irradiation processing is costly and hazardous with conventional routes. Here, we report a rapid alkali-fusion method that converts Ir metal directly into chloride media compatible with downstream separations. In the process, an Ir foil is fused with Na 2 O 2 and KCl at temperatures above the KCl melting point; the molten salt enhances heat transfer and facilitates O 2− /Na + transport to the Ir surface, overcoming Ir's oxidation resistance. The fused cake is then cooled and leached in 10 M HCl, yielding Ir in solution without specialized microwave digestion or HF. Pt separation from bulk Ir was evaluated using extraction-chromatography resins. A newly formulated ionic-liquid resin containing Cyphos IL 104 (E104) was compared with two commercial resins (TrisKem TK200 and TK201). All resins achieved >90 % Ir recovery. Pt co-recovery depended on resin chemistry: TK200 recovered 85.9 % Pt, TK201 recovered 54.1 % Pt, and E104 recovered 72.9 % Pt. This study introduces a fast, scalable dissolution route for solid Ir targets and demonstrates resin choices that tune Ir/Pt separation, lowering the barrier to routine production and purification of Pt radioisotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Survey of Neutron Induced Fission Experimental and Evaluated Data for 233 U, 238 Pu, 240 Pu, and 242 Pu between 100 keV and 20 MeV

We review data and evaluations for neutron-induced fission for the actinides 233 U, 238 Pu, 240 Pu and 242 Pu. These isotopes are part of common nuclear fuel cycles, especially for modern fast reactors. We focus on incident neutrons in the energy range of 100 keV to 20 MeV and compare the experimental data from the literature to the major evaluated libraries ENDF/B-VIII.1, JENDL-5, and JEFF-3.3, as well as to LLNL’s ENDL-2009.5 library. Based on the assessment of the fission cross sections, we provide recommendations on which library to use. Additional assessments covering other reaction channels will be provided separately.

07 ISOTOPE AND RADIATION SOURCES↗

Results of Speciation Determination Measurements of Insulating Sulfur Hexafluoride Gas

Under the direction of the NNSA NA-231 Mo-99 Program, SRNL has provided technical assistance to U.S. companies under cooperative agreements. One such area of technical assistance has been for the recommendation for contamination management methods in the eventuality that tritium contaminates the insulating gas of a high-voltage ion source used in the accelerator-based process developed by SHINE Medical Technologies to produce Mo-99. The SHINE accelerator process uses tritium as the target of a deuterium ion beam, where the ion beam is produced within a high-voltage ion source insulated with sulfur hexafluoride (SF 6 ), and is separated from the tritium target by an extensive pump train. Normal operating conditions preclude the conditions necessary for contamination of the insulating gas, however certain atypical conditions could result in a tritium contamination event. Accelerator based processes for medical isotope production represent an anomalous tritium contamination challenge due to the presence of SF 6 . SF 6 decomposes through normal use as an insulator gas, and the exact speciation of the decomposition byproducts depends on a variety of factors. This creates a scenario where the anticipation of species present in the insulating gas mixture is difficult. In turn, the fate of tritium within such a chemical system is unclear. This document discusses the results of measurements made in-situ of the SF 6 insulating gas in use within a SHINE Medical Technology’s high-voltage ion source. This was done in an effort to determine the chemical speciation of the gas, allowing for the recommendation of management strategies in the event that tritium contaminates the insulating gas. The results of the measurements reported in this work suggest that tritium contamination in the insulating gas may result in two chemical forms of tritium in the system, tritiated water and molecular tritium. These two forms of tritium would be captured by two methods. Tritiated water may be captured and removed from the SF 6 by an adsorbent canister already present within the pressure vessel that houses the insulating gas while in use. It may also be separated from the SF 6 during routine purification of the SF 6 , which is performed by SHINE personnel routinely. The purification cart will perform all non-embedded systems cleanup necessary to remediate tritiated species in the system. The purification cart passes the insulating gas through several filters, followed by the liquefication of the SF 6 . The filters will separate tritiated water from the SF 6 at this stage. It is expected that molecular tritium will accumulate in the gas-phase during the liquification step, which is separated and stored. Tritium may be recovered from this mixture through more conventional hydrogen purification methods such as a palladium diffuser.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SPRUCE 13C-Phospholipid Fatty Acid (13C-PLFA) Abundances, June 2014-June 2015

This data set provides the results of 13C phospholipid fatty acid analysis (13C-PLFA) of peat samples collected from ambient and experimental plots in the SPRUCE experiment site. The samples used to generate this data set were collected just prior to initiation of deep peat heating (DPH; 03 June 2014), after 3 months (09 September 2014), and after 10 months (16 June 2015). This data set includes the abundances and delta-13C isotopic signatures of individual lipids and of groups of lipids indicating total biomass, fungi, Gram-positive bacteria, Gram-negative bacteria, actinomycetes, and anaerobic bacteria. This dataset contains two files in comma separate (*.csv) format. Cores extending to 250 cm (200 cm in June 2015) were collected and subsampled at 10 cm intervals from 0 and 100 cm and 25 cm intervals below 100 cm depth. During the lipid extraction procedure, samples were pooled into the following depth increments in order to obtain sufficient material to achieve adequate lipid yield: 0-20, 20-50, 50-100, 100-150, 150-200, and 200-250cm.

actinomycetes↗

Sapflow and xylem water isotopes from Snodgrass Mountain, East River Watershed, Colorado USA

This dataset includes sapflux and stable water isotopes of soil water and xylem water for aspen, fir and spruce trees along the Snodgrass Mountain transect in the East River Watershed, Colorado USA. The purpose of generating this dataset was to understand: (1) the total flux of water being used by trees in the watershed, (2) separate the component of transpiration that was derived from recent precipitation vs. older water such as winter precipitation of groundwater and (3) understand how total water use and water sources for the trees varies between species and position on a hillslope. The data were collected from May 2019 until October 2022. The sap flux data were collected using ICT SFM1 sensors and are presented in both units of cm h^-1 and as kg h^-1 by multiplying the sap flux by the sapwood area of the tree. All sap flow data has been been corrected using estimates of wounding diameter, water content of wood and sap wood depth. The xylem water isotope data were collected approximately weekly from each of the trees instrumented with sap flux. The stems were collected and the water extracted using classic cryogenic methods. Isotope measurements were done using a Picarro 2140i analyzer. We provide an estimate of the Seasonal Origin Index for each measurements following Allen et al., 2019 (10.5194/hess-23-1199-2019) where values of -1 equate to trees relying on winter precipitation and +1 tree relying on summer precipitation. We also provide the simultaneous sap flux for each isotope measurement when this data was available. This is an update to an earlier data repository with the same name that only included 2019 data. The new dataset was posted in January 2023 and is inclusive of the original 2019 data but now includes 2021 and 2022 data. Please note there was an error in the units of transpiration in the original dataset. It was incorrectly listed as mm h-1 when it should have been kg h-1. This change was made in May 2024.

54 ENVIRONMENTAL SCIENCES↗

New proton emitter 188 At implies an interaction unprecedented in heavy nuclei

We report the discovery of a new atomic nucleus 188 At, which is the heaviest proton-emitting isotope known to date. The new activity was observed through the 107 Ag( 84 Sr, 3n) 188 At fusion-evaporation reaction using the focal-plane spectrometer of the gas-filled recoil separator in the Accelerator Laboratory of the University of Jyväskylä, Finland. To fully interpret the experimental data, we have expanded the non-adiabatic quasiparticle model to treat nuclei in the beyond-lead region. The description reproduced the measured decay rate and pointed towards emission from an extremely prolate-deformed state with a dominant s 1/2 proton component in the wave function. The Thomas-Ehrman shift can be enhanced in low angular momentum states, but such effects have not been observed in heavy nuclei. The single-proton separation energy of 188 At deviates from that extrapolated from the systematics, which can be interpreted as the first evidence of this effect in heavy nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Foliar isotopic and elemental biochemistry and leaf mass per area (LMA), Parque Natural Metropolitano, Panama, 2022

Foliar N and C isotope composition, bulk elemental N and C composition, and leaf mass per area (LMA) for leaves sampled from the Parque Natural Metropolitano (PNM), Panama, from January to April 2022 are presented. Measurements were made on leaves from 17 different tree, shrub and liana species, from sunlit canopy and understory locations on 8 vertical profiles. Full sample details and leaf area index (LAI) from the vertical profiles at PNM are also included in the data package. The aim of this measurement campaign was two-fold: to improve our understanding of the vertical variation in leaf-level water use efficiency, and to improve models which can predict leaf traits from leaf contact spectral measurements. Biochemistry data and sample metadata are presented in .csv files. The original isotopic data report, which includes details about standards and data accuracy, is provided in .xlsx format. Data and metadata meet the ESS-DIVE reporting format requirements for file level metadata (FLMD) and comma separated values (csv). The protocol details are provided as pdf documents. In addition to foliar biochemistry data reported here these samples were also used for measurement of leaf gas exchange, and leaf optical properties. These data can be linked using the unique sample ID and are provided in separate data packages (NGT0192 and NGT0193).

54 ENVIRONMENTAL SCIENCES↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗

13 C-Isotope-Assisted Assessment of Metabolic Quenching During Sample Collection from Suspension Cell Cultures

Metabolomics and fluxomics are core approaches to directly profile and interrogate cellular metabolism in response to various genetic or environmental perturbations. In order to accurately measure the abundance and isotope enrichment of intracellular metabolites, cell culture samples must be rapidly harvested and cold-quenched to preserve the in vivo metabolic state of the cells at the time of sample collection. When dealing with suspension cultures, this process is complicated by the need to separate the liquid culture media from cellular biomass prior to metabolite extraction. Here, we examine the efficacy of several commonly used metabolic quenching methods, using the model cyanobacterium Synechocystis sp. PCC 6803 as an example. Multiple 13 C-labeled compounds, including 13 C-bicarbonate, 13 C-glucose and 13 C-glutamine, were used as tracers during the sample collection and cold-quenching process to assess the extent of metabolic turnover after cells were harvested from culture flasks. We show that the combination of rapid filtration followed by 100% cold (–80°C) methanol quenching exhibits the highest quenching efficiency, while mixing cell samples with a partially frozen 30% methanol slurry (–24°C) followed by centrifugation is slightly less effective at quenching metabolism but enables less laborious sample processing. By contrast, rapidly mixing the cells with a saline ice slurry (~0°C) is less effective as indicated by high isotope-labeling rates after sample harvest, while mixing the cells with 60% cold methanol (–65°C) prior to centrifugation causes significant metabolite loss. Furthermore, this study demonstrates a rigorous, quantitative, and broadly applicable method for assessing the metabolic quenching efficacy of protocols used for sample collection in metabolomics and fluxomics studies.

59 BASIC BIOLOGICAL SCIENCES↗

Behavior of selenium and arsenic in $\mathrm{HCl}$ and $\mathrm{HNO}$ 3 on $\mathrm{TRU, TEVA, DGA,}$ and $\mathrm{Pb}$ extraction chromatography resins

The uptake behavior of 73 As and 75 Se was studied in HCl and HNO 3 -H 2 O 2 solutions on commercial extraction chromatography resins (TEVA, TRU, DGA, and Pb resin). There was no uptake of 73 As or 75 Se from HNO 3 media. From HCl, there was 75 Se uptake at high concentrations on all the resins and no uptake of 73 As. Separations of 75 Se and 73 As on these resins have high yields and high radiopurity for 73 As, but limited recovery of 75 Se. TRU and TEVA resin may have potential for use in isotope generators as 75 Se can be retained for at least 26 days with repeated elutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

SPRUCE Sphagnum Phytobiome Responses to Whole Ecosystem Warming and Elevated Atmospheric CO2 in July, 2017-2021

This dataset reports the carbon (C) and nitrogen (N) isotopic composition of Sphagnum moss tissue collected from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. Tissues were collected inside the SPRUCE experimental study plot, where air and peat warming are combined in whole-ecosystem warming treatments, from 2019-2021. Additionally, rates of nitrogen fixation and methane oxidation measured for Sphagnum from 2017, 2019, and 2021. Sphagnum tissue % water content was measured at all timepoints. This dataset was used to conduct analyses within Petro et al (2023). Sphagnum C and N concentrations and 13C and 15N isotopic natural abundance were determined for three replicate Sphagnum tissue samples collected from inside the SPRUCE enclosures in July 2019-2021. Elemental and isotope analyses were conducted at the University of Georgia – Center for Applied Isotope Studies (CAIS; https://cais.uga.edu/). Plant elemental analysis was performed by the micro-Dumas method, while isotopic natural abundance was measured by isotope ratio mass spectrometry. 13C natural abundance is expressed as the per mille (‰) deviation from the Pee Dee Belemnite standard (PDB) 13C:12C ratio (δ13C), while 15N natural abundance is expressed as the ‰ deviation from the N2 atmospheric 15N:14N ratio (δ15N). Rates of nitrogen fixation and methane oxidation were measured using serum bottle incubations performed with Sphagnum collected inside the SPRUCE enclosures in July 2017, 2019, and 2021. Rates were calculated according to the amount of 15N-N2 or 13C-CH4 (methane) incorporated into the Sphagnum tissue or incubation headspace over the 48-hour intion period. In 2017, incubations were performed in growth chambers set to the temperature of the experimental plots during Sphagnum sampling. In 2019 and 2021, the incubations were performed directly inside the experimental plots. The 13C and 15N isotopic natural abundance data and rate measurements presented in this dataset provide insight into the impacts of whole-ecosystem warming and elevated atmospheric carbon dioxide (CO2) on N and C cycling within the Sphagnum phytobiome. This dataset contains two data files in comma-separate values (*.csv) format. Additional metadata are provided: two data dictionaries and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format. Additional datasets on NH4-N availability, porewater concentrations of CH4 and CO2, and Sphagnum groundcover within the SPRUCE experimental plots are available. These are outlined in the Related Datasets section in the user guide.

delta 13 carbon↗

The Isotopic Limit of Recycling

Despite advances in recycling technologies and practices, the world still mostly operates on a once-through materials use cycle. The once-through approach to the materials supply chain cannot work into perpetuity. The vast majority of current recycling efforts focus on mechanical or chemical separation-based techniques and are often subsequently limited on the number of times a component can be recycled or upcycled. By looking at things from a particle physics and nuclear history perspective, we propose a thought experiment to determine the physical limit of recycling and propose subsequent limits and standards to evaluate all recycling efforts. This uncommon approach to analysis demonstrates that the current limits to recycling are not physical in nature but engineering.

Lang, Eric↗

Carbon, Nitrogen, and Sulfur Analysis of the Cetama Viognier Standard Reference Material

The Viognier sample was analyzed for C, N, and S concentrations and stable isotope compositions using an Elementar Vario Isotope Cube Elemental Analyzer (EA) that is coupled to an IsoPrime PrecisION IRMS. Powder samples were placed in tin capsules and then loaded onto a rotary autosampler. The autosampler dropped samples into the EA, and samples were combusted at 1175 °C over tungsten oxide in a continuous stream of helium carrier gas. A pulse of oxygen is added to the gas stream resulting in flash combustion of the tin capsule containing the sample, which raises the reaction temperature to approximately 1800 °C for a few seconds. The combustion reaction produces SO 2 , N 2 and CO 2 from any sulfur, nitrogen and carbon present in the sample. The resulting gases were then passed through a reduced copper reactor that was heated to 850 °C, to reduce NO x to N 2 , reduce SO 3 to SO 2 , and trap any volatile halogen compounds on silver wool. Following water removal using an adsorption tube, the N 2 , CO 2 , and SO 2 analyte gases were separated and purified using purge-trap columns. The purified gases were then carried through a thermal conductivity detector. The detector signal was passed to software that calculated elemental abundances based on integrated peak areas. The sample gases were then passed to the IRMS and stable isotope ratios were measured. Raw sample peak areas were corrected by subtracting the average peak area from blanks consisting of empty tin capsules run using the same EA analysis method. Blanks were also run following each replicate to verify that all the material was combusted. The Viognier sample was analyzed in triplicate on two days (target sample masses: 30, 60 and 90 mg). The following standards were analyzed to calibrate EA-IRMS measurements: IAEA-C6, USGS-40, USGS-41, IAEA-S1, and IAEA-S2.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Exploring rapid chemical separations of Sc-47 produced from photonuclear reactions on natural vanadium targets

Scandium-47 ( 47 Sc) production via bremsstrahlung irradiation of natural vanadium targets offers significant advantages for producing high purity 47 Sc; this work evaluates several rapid dissolution and chemical separation techniques for recovering high purity 47 Sc from irradiated vanadium. Here, techniques developed are combined into a simple, gram-scale, semi-automated target processing system that enables 47 Sc recovery from irradiated vanadium targets with chemical yields as high as 93 ± 3% and 47 Sc/V separation factors of 6 ± 3 ·10 11 within 90 min total processing times. Future research into H 2 O 2 resistant separation techniques and their applicability for direct process coupling to chelation are recommended.

07 ISOTOPE AND RADIATION SOURCES↗