Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Charge state distributions of oxygen and carbon in the energy range 1 to 300 keV/e observed with AMPTE/CCE in the magnetosphere

Observations of charge state distributions of oxygen and carbon are presented that were obtained with the charge-energy-mass spectrometer onboard the AMPTE/CCE spacecraft. Data were selected for two different local time sectors (apogee at 1300 LT and 0300 LT, respectively), three L-ranges (4-6, 6-8, and greater than 8), and quiet to moderately disturbed days (Kp less than or equal to 4). The charge state distributions reveal the existence of all charge states of oxygen and carbon in the magnetosphere. The relative importance of the different charge states strongly depends on L and much less on local time. The observations confirm that the solar wind and the ionosphere contribute to the oxygen population, whereas carbon only originates from the solar wind. The L-dependence of the charge state distributions can be interpreted in terms of these different ion sources and of charge exchange and diffusion processes that largely influence the distribution of oxygen and carbon in the magnetosphere.

Kremser, G.↗

Thin film growth rate effects for primary ion beam deposited diamondlike carbon films

Diamondlike carbon (DLC) films were grown by primary ion beam deposition and the growth rates were measured for various beam energies, types of hydrocarbon gases and their ratio to Ar, and substrate materials. The growth rate had a linear dependence upon hydrocarbon content in the discharge chamber, and only small dependence on other parameters. For given deposition conditions a threshold in the atomic ratio of carbon to argon gas was identified below which films did not grow on fused silica substrate, but grew on Si substrate and on existing DLC films. Ion source deposition parameters and substrate material were found to affect the deposition threshold and film growth rates.

Nir, D.↗

A plasma generator utilizing the high intensity ASTROMAG magnets

The magnet configuration for the proposed particle astrophysics magnet facility (ASTROMAG) on the space station includes a cusp magnetic field with an intensity of a few tesla. With these large magnets (or others) located in the outer ionosphere, many quite interesting and unique plasma physics experiments become possible. First there are studies utilizing the magnet alone to examine the supersonic, sub-Alfvenic interaction with the ambient medium; the scale length for the magnet perturbation is approx. 20 m. The magnetic field geometry when combined with the Earth's and their relative motion will give rise to a host of plasma phenomena: ring nulls, x-points, ion-acoustic and lower-hybrid shocks, electron heating (possible shuttle glow without a surface) launching of Alfvenwaves, etc. Second, active experiments are possible for a controlled study of fundamental plasma phenomena. A controlled variable species plasma can be made by using an RF ion source; use of two soft iron rings placed about the line cusp would give an adequate resonance zone (ECH or ICH) and a confining volume suitable for gas efficiency. The emanating plasma can be used to study free expansion of plasma along and across field lines (polar wind), plasma flows around the space platform, turbulent mixing in the wake region, long wavelength spectrum of convecting modes, plasma-dust interactions, etc.

Sullivan, James D.↗

The Comet Giacobini-Zinner magnetotail: Axial stresses and inferred near-nucleus properties

Utilizing the electron and magnetic field data from the ICE tail traversal of comet Giacobini-Zinner along with the MHD equations, a steady state, stress balance model of the cometary magnetotail was developed, and used to infer important but unmeasured ion properties within the magnetotail at ICE and upstream at the average point along each streamline where cometary ions are picked-up. The derived tailward ion flow speed at ICE is quite constant at approx. -20 to -30 km/sec across the entire tail. The flow velocity, ion temperature, density, and ion source rates upstream from the lobes (current sheet) at the average pick-up locations are approx. -75 km/sec (approx. -12), approx. 4 million K (approx. 100,000), approx. 20 cc (approx. 400), and approx. 15 cu cm/sec. Gradients in the plasma properties between the two regions are quite strong. Implications of inferred plasma properties for the near-nucleus region and for cometary magnetotail formation are examined.

Mccomas, D. J.↗

Enhanced thermal emittance of space radiators by ion-discharge chamber texturing

The discharge chamber of a 30-cm argon ion source was successfully used to texture potential space radiator materials for the purpose of obtaining values of thermal emittance greater than 0.85 at 700 and 900 K. Some samples were also treated in acid prior to texturing. To evaluate the durability of the textured materials to atomic oxygen, samples were exposed to an RF air plasma environment. The spectral emittance between 2.0 anf 15.0 microns was measured before and after the textured materials were exposed to the plasma asher. The results indicate that copper with extremely high values of emittance after texturing (0.978 and 0.983) at 700 and 900 K, respectively,did not change its values of emittance after ashing, whereas the emittance of stainless steel fell below 0.85 after ashing. These data, along with scanning electron photomicrographs, and the results of texturing and ashing titanium and Nb(1)Zr are presented .

Mirtich, Michael J.↗

Martin Marietta atomic oxygen Low Earth Orbit (LEO) simulation

An atomic oxygen beam apparatus that produces flux levels and atomic kinetic energy similar to that encountered by spacecraft in low Earth orbit (LEO) is described. The beam apparatus consists of an electric discharge ion source, mass filter, decelerator, and neutralizer. Specific design goals include a 1.3 cm beam diameter, a 5 eV beam energy, and a flux density on the order of 10(15) cm(-2) s(-1). The total fluence will be on the order of 10(19) cm(-2) for an 8 hour test. The neutral oxygen beam will expose various materials contained within a large target chamber. Within the chamber will be a rather complex suite of instrumentation that will allow real-time studies of material mass loss and reactant species spatial distribution. In addition, a UV solar simulator will aid in the understanding of various synergistic effects.

Sjolander, Gary W.↗

Chemically assisted ion beam etching of polycrystalline and (100)tungsten

A chemically assisted ion-beam etching technique is described which employs an ion beam from an electron-bombardment ion source and a directed flux of ClF3 neutrals. This technique enables the etching of tungsten foils and films in excess of 40 microns thick with good anisotropy and pattern definition over areas of 30 sq mm, and with a high degree of selectivity. (100) tungsten foils etched with this process exhibit preferred-orientation etching, while polycrystalline tungsten films exhibit high etch rates. This technique can be used to pattern the dispenser cathode surfaces serving as electron emitters in traveling-wave tubes to a controlled porosity.

Garner, Charles↗

Ion-beam nitriding of steels

A surface of a steel substrate is nitrided without external heating by exposing it to a beam of nitrogen ions under low pressure, a pressure much lower than that employed for ion-nitriding. An ion source is used instead of a glow discharge. Both of these features reduce the introduction of impurities into the substrate surface.

Salik, Joshua↗

Nonvolatile Ionic Two-Terminal Memory Device

Conceptual solid-state memory device nonvolatile and erasable and has only two terminals. Proposed device based on two effects: thermal phase transition and reversible intercalation of ions. Transfer of sodium ions between source of ions and electrical switching element increases or decreases electrical conductance of element, turning switch "on" or "off". Used in digital computers and neural-network computers. In neural networks, many small, densely packed switches function as erasable, nonvolatile synaptic elements.

Williams, Roger M.↗

Upward ion flow in ionospheric holes on Venus

The nature of ion flow within two ionospheric holes on the nightside of Venus was investigated using ion composition measurements made by the ion mass spectrometer on the Pioneer Venus Orbiter. A comparison of the altitude profiles of the observed ion densities with those expected under diffusive equilibrium conditions indicates that the major ions O(+), NO(+), and O2(+), as well as the minor ions H(+) and He(+) flow upward and away from Venus along the axes of the holes. This result agrees with a quantitative evaluation of the ion flow speeds appearing in expressions derived from the equations for conservation of mass and momentum of the ions and electrons. The analysis shows that all ion species flow upward in the holes because the upward force produced by the plasma pressure gradient exceeds all downward forces. However, the nature of the ion source required to maintain such flow is not known.

Hartle, R. E.↗

Ion beam sputtering of in situ superconducting Y-Ba-Cu-O films

Oriented superconducting YBa2Cu3O7 thin films were deposited on yttria stabilized zirconia and SrTiO3 substrates by ion-beam sputtering of a nonstoichiometric oxide target. The films exhibited zero-resistance critical temperatures as high as 83.5 K without post-deposition anneals. Both the deposition rate and the c-lattice parameter data displayed two distinct regimes of dependence on the beam power of the ion source. Low-power sputtering yielded films with large c-dimensions and low Tc. Higher-power sputtering produced a continuous decrease in the c-lattice parameter and increase in critical temperature. Films having the smaller c-lattice parameters were Cu rich. The Cu content of films deposited at beam voltages of 800 V and above increased with increasing beam power.

Klein, J. D.↗

Dual ion beam processed diamondlike films for industrial applications

Single and dual beam ion source systems are used to generate amorphous diamondlike carbon (DLC) films, which were evaluated for a variety of applications including protective coatings on transmitting materials, power electronics as insulated gates and corrosion resistant barriers. A list of the desirable properties of DLC films along with potential applications are presented.

Mirtich, M. J.↗

The ultraviolet photochemistry of diacetylene - Direct detection of primary products of the metastable C4H2* + C4H2 reaction

The products of diacetylene's ultraviolet photochemistry over the 245-220 nm region were directly determined in experiments where C4H2 was excited within a small reaction tube attached to a pulsed nozzle. The products formed in the collisions of C4H2* with C4H2 were subsequently ionized by vacuum UV radiation (at 118 nm) in the ion source of a time-of-flight mass spectrometer. It was found that the reaction of C4H2* with C4H2 produces C6H2 (+C2H2), C8H2 (+2H,H2), and C8H3 (+H), confirming the results of Glicker and Okabe (1987). Under certain conditions, secondary products were observed. Mechanisms for the observed reactions are proposed.

Bandy, Ralph E.↗

Development of an advanced spacecraft tandem mass spectrometer

The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

Drew, Russell C.↗

Electric Propulsion: Experimental Research

This paper describes experimental electric propulsion research which was carried out at the University of Tennessee Space Institute with support from the Center for Space Transportation and Applied Research. Specifically, a multiplexed LIF technique for obtaining vector velocities, Doppler temperatures, and relative number densities in the exhaust plumes form electric propulsion devices is described, and results are presented that were obtained on a low power argon arcjet. Also, preliminary Langmuir probe measurements on an ion source are described, and an update on the vacuum facility is presented.

Ruyten, W. M.↗

The Diagnostics of the External Plasma for the Plasma Rocket

Three regions of plasma temperature/energy are being investigated to understand fully the behavior of the plasma created by the propulsion device and the operation of the RPA. Each type of plasma has a RPA associated with it; i.e. a thermal RPA, a collimated RPA, and a high temperature RPA. Through the process of developing the thermal and collimated RPAs, the proper knowledge and experience has been gained to not only design a high temperature RPA for the plasma rocket, but to understand its operation, results, and uncertainty. After completing a literature search for, reading published papers on, and discussing the operation of the RPA with electric propulsion researchers, I applied the knowledge gained to the development of a RPA for thermal plasma. A design of a thermal RPA was made which compensates for a large Debye length and low ionized plasma. From this design a thermal RPA was constructed. It consists of an outer stainless steel casing, a phenolic insulator (outgases slightly), and stainless steel mesh for the voltage screens. From the experience and knowledge gained in the development of the thermal RPA, a RPA for collimated plasma was developed. A collimated RPA has been designed and constructed. It compensate for a smaller Debye length and much higher ionization than that existing in the thermal plasma. It is 17% of the size of the thermal RPA. A stainless steel casing shields the detector from impinging electrons and ions. An insulating material, epoxy resin, was utilized which has a negligible outgassing. This material can be molded in styrofoam and machined quite nicely. It is capable of withstanding moderately high temperatures. Attached to this resin insulator are inconel screens attached by silver plated copper wire to a voltage supply. All the work on the RPAs and thermal ion source, I performed in the University of Alabama in Huntsville's (UAH) engineering machine shop.

Karr, Gerald R.↗

Measurement of OH, H2SO4, MSA, DMSO, DMSO2 on the NASA P-3B Aircraft

This project involves the deployment of a variety of unique aircraft measurements for the PEM-Tropics program. These measurements were all to be accomplished on a near simultaneous basis using a two channel selected ion chemical ionization mass spectrometer instrument. The first year of this project consisted of four components; improve and perform additional testing of the OH, H2SO4, and MSA instrument which had only flown on one previous mission (ACE-I); develop and test the vacuum and electronic hardware and software which would allow two independent mass spectrometer systems to be operated from a single instrument (one vacuum/pumping system); construct an aircraft compatible DMSO/DMS02 ion source and calibration system; and operate the above system on the NASA P-3B during PEM-Tropics. The first two of the components were to be accomplished at NCAR. The third component was to be completed at Georgia Tech and the fourth was to be conducted by researchers from both institutions on the NASA P-3B.

Eisele, F. L.↗

Deep Atmosphere Ammonia Mixing Ratio at Jupiter from the Galileo Probe Mass Spectrometer

New laboratory studies employing the Engineering Unit (EU) of the Galileo Probe Mass Spectrometer (GPMS) have resulted in a substantial reduction in the previously reported upper limit on the ammonia mixing ratio derived from the GPMS experiment at Jupiter. This measurement is complicated by background ammonia contributions in the GPMS during direct atmospheric sampling produced from the preceding gas enrichment experiments. These backgrounds can be quantified with the data from the EU studies when they are carried out in a manner that duplicates the descent profile of pressure and enrichment cell loading. This background is due to the tendency of ammonia to interact strongly with the walls of the mass spectrometer and on release to contribute to the gas being directly directed into the ion source from the atmosphere through a capillary pressure reduction leak. It is evident from the GPMS and other observations that the mixing ratio of ammonia at Jupiter reaches the deep atmosphere value at substantially higher pressures than previously assumed. This is a likely explanation for the previously perceived discrepancy between ammonia values derived from ground based microwave observations and those obtained from attenuation of the Galileo Probe radio signal.

Mahaffy, P. R.↗