Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

High Repetition Rate Pulsed 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed at NASA Langley Research Center. Such a laser transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of approximately 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. The measured standard deviation of the laser frequency jitter is about 3 MHz.

Singh, Uprendra N.↗

Coupled Hydromechanical Modeling of Induced Seismicity From CO 2 Injection in the Illinois Basin

Injection of CO 2 for geologic carbon sequestration into deep sedimentary formations involves fluid pressure increases that engage hydromechanical processes that can cause seismicity by activation of existing faults. In this work, we use a coupled multiphase fluid flow and geomechanical simulator to model spatiotemporal fluid pressure and stress changes in order to study the poroelastic effect of CO 2 injection on faults in crystalline basement rock below the injection zone. The seismicity rate along features interpreted to be basement faults is modeled using Dieterich's rate-and-state earthquake nucleation model. The methodology is applied to microseismicity detected during CO 2 injection into the Mount Simon formation during the Illinois Basin—Decatur Project. The modeling accurately captures an observed reduction in seismicity rate when the injection in the second well was into a slightly shallower zone above the base of the Mount Simon formation. Moreover, the modeling shows that it is important to consider poroelastic stress changes, in addition to fluid pressure changes for accurately modeling of the observed seismicity rate.

58 GEOSCIENCES↗

Injection-induced turbulence in stagnation-point boundary layers

A theory is developed for the stagnation point boundary layer with injection under the hypothesis that turbulence is produced at the wall by injection. From the existing experimental heat transfer rate data obtained in wind tunnels, the wall mixing length is deduced to be a product of a time constant and an injection velocity. The theory reproduces the observed increase in heat transfer rates at high injection rates. For graphite and carbon-carbon composite, the time constant is determined to be 0.0002 sec from the existing ablation data taken in an arc-jet tunnel and a balistic range.

Park, C.↗

TPSAS-NF1676L-11931-DND

Researchers at NASA Langley Research Center have developed an efficient, high repetition rate, pulsed, 2-µm coherent DIAL/IPDA transmitter for CO2 measurements. This transmitter will be employed to measure atmospheric CO2 profiles (by DIAL) initially from a ground platform, and then measure both the atmospheric CO2 profiles (by DIAL) and column densities (by IPDA) from an airborne platform with the potential for measuring CO2 column density from a space-borne platform. The transmitter consists of a pulsed Q-switched ring-cavity Ho:YLF laser operating at 2.05 micron, being pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz with corresponding energy of 25 to 1 mJ, respectively. This transmitter can be used for direct or coherent detection of CO2 from ground, air or space-borne platform, as it is capable of providing required energy/repetition rate even from space platform. This presentation will describe the details of the injection-seeded highrepetition rate 2-micron transmitter and demonstrate its flexibility for direct or coherent detection of CO2.

Upendra N Singh↗

Photoionization-regulated star formation and the structure of molecular clouds

A model for the rate of low-mass star formation in Galactic molecular clouds and for the influence of this star formation on the structure and evolution of the clouds is presented. The rate of energy injection by newly formed stars is estimated, and the effect of this energy injection on the size of the cloud is determined. It is shown that the observed rate of star formation appears adequate to support the observed clouds against gravitational collapse. The rate of photoionization-regulated star formation is estimated and it is shown to be in agreement with estimates of the observed rate of star formation if the observed molecular cloud parameters are used. The mean cloud extinction and the Galactic star formation rate per unit mass of molecular gas are predicted theoretically from the condition that photionization-regulated star formation be in equilibrium. A simple model for the evolution of isolated molecular clouds is developed.

Mckee, Christopher F.↗

Separation Control in a Multistage Compressor Using Impulsive Surface Injection

Control of flow separation using impulsive surface injection is investigated within the multistage environment of a low speed axial-flow compressor. Measured wake profiles behind a set of embedded stator vanes treated with suction-surface injection indicate significant reduction in flow separation at a variety of injection-pulse repetition rates and durations. The corresponding total pressure losses across the vanes reveal a bank of repetition rates at each pulse duration where the separation control remains nearly complete. This persistence allows for demands on the injected-mass delivery system to be economized while still achieving effective flow control. The response of the stator-vane boundary layers to infrequently applied short injection pulses is described in terms of the periodic excitation of turbulent strips whose growth and propagation characteristics dictate the lower bound on the band of optimal pulse repetition rates. The eventual falloff in separation control at higher repetition rates is linked to a competition between the benefits of pulse-induced mixing and the aggravation caused by the periodic introduction of low-momentum fluid. Use of these observations for impulsive actuator design is discussed and their impact on modeling the time-average effect of impulsive surface injection for multistage steady-flow simulation is considered.

Wundrow, David W.↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flow visualization study of the effect of injection hole geometry on an inclined jet in crossflow

A flow visualization was studied by using neutrally buoyant, helium-filled soap bubbles, to determine the effect of injection hole geometry on the trajectory of an air jet in a crossflow and to investigate the mechanisms involved in jet deflection. Experimental variables were the blowing rate, and the injection hole geometry cusp facing upstream (CUS), cusp facing downstream (CDS), round, swirl passage, and oblong. It is indicated that jet deflection is governed by both the pressure drag forces and the entrainment of free-stream fluid into the jet flow. For injection hole geometries with similar cross-sectional areas and similar mass flow rates, the jet configuration with the larger aspect ratio experienced a greater deflection. Entrainment arises from lateral shearing forces on the sides of the jet, which set up a dual vortex motion within the jet and thereby cause some of the main-stream fluid momentum to be swept into the jet flow. This additional momentum forces the jet nearer the surface. Of the jet configurations, the oblong, CDS, and CUS configutations exhibited the largest deflections. The results correlate well with film cooling effectiveness data, which suggests a need to determine the jet exit configuration of optimum aspect ratio to provide maximum film cooling effectiveness.

Simon, F. F.↗

Flow visualization study of the effect of injection hole geometry on an inclined jet in crossflow

A flow visualization was studied by using neutrally buoyant, helium-filled soap bubbles, to determine the effect of injection hole geometry on the trajectory of an air jet in a crossflow and to investigate the mechanisms involved in jet deflection. Experimental variables were the blowing rate, and the injection hole geometry cusp facing upstream (CUS), cusp facing downstream (CDS), round, swirl passage, and oblong. It is indicated that jet deflection is governed by both the pressure drag forces and the entrainment of free-stream fluid into the jet flow. For injection hole geometries with similar cross-sectional areas and similar mass flow rates, the jet configuration with the larger aspect ratio experienced a greater deflection. Entrainment arises from lateral shearing forces on the sides of the jet, which set up a dual vortex motion within the jet and thereby cause some of the main-stream fluid momentum to be swept into the jet flow. This additional momentum forces the jet nearer the surface. Of the jet configurations, the oblong, CDS, and CUS configurations exhibited the largest deflections. The results correlate well with film cooling effectiveness data, which suggests a need to determine the jet exit configuration of optimum aspect ratio to provide maximum film cooling effectiveness.

Simon, Frederick F.↗

A study of dynamic measurements made in the settling chamber of the Langley 0.3-meter transonic cryogenic tunnel

Tests have been conducted in a cryogenic wind tunnel settling chamber using a fast response instrumentation to measure the possible existence of temperature fronts due to a sudden or step change in the rate of liquid nitrogen injection into the circuit. No indications of such fronts were obtained using three different techniques to change the rate of nitrogen injection. The normalized pressure and velocity fluctuations at two total temperatures and over a large range of Mach numbers and Reynolds numbers were about 2 x 10 to the -7th to 2 x 10 to the -6th and about 1.8 to 3 percent, respectively. There was no evidence of liquid nitrogen droplets in the flow down to a total temperature of 140 K. The pressure fluctuation power spectra from a pressure transducer correlated with the fan blade passage through the eighth harmonic of the fundamental frequency.

Johnson, C. B.↗

Study of Foam Fracturing for Enhanced Geothermal Systems Using Model Material

Foam fracturing is considered a potential approach to address water concerns with hydraulic fracturing in the development of enhanced geothermal systems (EGS). In many EGS sites, water required for hydraulic fracturing is either unavailable, extremely costly or environmentally unsustainable. This paper presents work performed in the first year of a project sponsored by the U.S. DOE GTO Waterless Stimulation Initiative that investigates foam fracturing as an alternative approach to hydraulic fracturing. One element of this work explores foam formulations that are suitable for EGS conditions. A separate paper submitted to this workshop covers the relevant work on foam characterization (Thakore et al., 2020).This paper describes the development of an experimental setup for studying the applicability of foam fluids for hydraulic fracturing along with enhanced fracture efficiency through cyclic pressurization. The system is equipped with pulse rate automation, dual pulse valves for enhanced pulsation amplitudes, and other functions. It can perform static injection at a given pressurization rate, and pulsed injection at specified pulse size and rate. Both single-phase and foamed fluids can be used. Initial experimental results of foam fracturing using cement as a model material are reported. The observations from the experimental work will be presented and discussed.

Wang, Hong↗

Ignition overpressure study from solid rocket motor firings

The objective was to investigate, through experimental means, the basic mechanisms influencing ignition overpressure and to determine ways to suppress ignition overpressure. Ignition overpressure was studied using solid rocket motors with geometry scaled at 1 percent of the Shuttle's Solid Rocket Boosters. Both water injection and aerosol foam were examined as a mean of reducing ignition overpressure. The results of the water injection tests indicate that a relatively small amount of water is sufficient to provide significant suppression. Of the flow rates tested, the lower water injection flow rates provided the best reduction of the ignition overpressure wave. Also, the test results show there is an optimum water flow rate range that provides the best suppression, and as this range is exceeded the effectiveness of water to reduce ignition overpressure is decreased. Aerosol foam provided very little reduction of ignition overpressure, but only small volumes of foam were used and further testing is necessary to determine its total effectiveness as a means of suppression.

Counter, Douglas D.↗

The Effect of Injection-Valve Opening Pressure on Spray-Tip Penetration

The effect of various injection-valve opening pressures on the spray-tip penetration was determined for several injection pressure. A common-rail fuel injection system was used. For a given injection pressure a maximum rate of penetration was obtained with an injection-valve opening pressure equal to the injection pressure. As the excess of the injection pressure over the injection-valve opening pressure was increased for a given injection pressure, the effect of the injection-valve opening pressure on the spray-tip penetration was increased.

Rothrock, A M↗

Influence of Reduced Mass Flow Rate and Chamber Backpressure on Swirl Injector Fluid Mechanics

Industry interest in variable-thrust liquid rocket engines places a demand on engine injector technology to operate over a wide range of liquid mass flow rates and chamber backpressures. One injection technology of current interest for variable thrust applications is an injector design with swirled fluids. Current swirl injector design methodologies do not take into account how swirl injector design parameters respond to elevated chamber backpressures at less than design mass flow rates. The current work was created to improve state-of-the-art swirl injector design methods in this area. The specific objective was to study the effects of elevated chamber backpressure and off-design mass flow rates on swirl injector fluid mechanics. Using a backpressure chamber with optical access, water was flowed through a swirl injector at various combinations of chamber backpressure and mass flow rates. The film thickness profile down the swirl injector nozzle section was measured through a transparent nozzle section of the injector. High speed video showed measurable increases in the film thickness profile with application of chamber backpressure and mass flow rates less than design. At prescribed combinations of chamber backpressure and injected mass flow rate, a discrete change in the film thickness profile was observed. Measured injector discharge coefficient values showed different trends with increasing chamber backpressure at low mass flow rates as opposed to near-design mass flow rates. Downstream spray angles showed classic changes in morphology as the mass flow rate was decreased below the design value. Increasing chamber backpressure decreased the spray angle at any injection mass flow rate. Experimental measurements and discussion of these results are reported in this paper.

Kenny, R Jeremy↗

Quantifying the effects of pressure management for the Williston basin Brine Extraction and Storage Test (BEST) site using machine learning

Active reservoir management (ARM) through brine extraction can reduce pressure buildup during large-scale implementation of carbon capture and storage (CCS) projects. This study used machine learning (ML)-assisted approaches to analyze bottomhole pressure (BHP) responses to various brine injection and extraction scenarios. Field monitoring data were collected over a 2-year operation period at two injection wells and one extraction well (about 400 meters away) as part of a Brine Extraction and Storage Test (BEST) in the North Dakota portion of the Williston Basin. Injection activities increased the BHPs at the injection wells by around 0.70 MPa (~100 psi) during the operation period. Extraction activities demonstrated the capability to decrease the BHPs at the injection wells by approximately 0.21–0.34 MPa (30–50 psi) depending on the ratio of the extraction and injection well flow rates (the “extraction ratio” – a normalization procedure used in the analysis). The pressure reduction provided by the extraction well equated to 30%–50% of the pressure buildup at the injection well. Furthermore, this work shows how ML analytics can play a key role in estimating reservoir pressure responses for complex injection and extraction activities during pressure management practices of CCS projects.

58 GEOSCIENCES↗

Deuterium recycling and wall retention characteristics during boron powder injection in EAST

Boron (B), as a low-Z material, is widely employed for wall conditioning to enhance plasma performance in fusion devices. In the Experimental Advanced Superconducting Tokamak, a series of experiments involving real-time B powder injection has been conducted to investigate fuel particle behavior. It was observed that fuel particle recycling decreased with an increase in the amount of B powder injected, resulting in an increase in short-term fuel retention. The fuel recycling decreased by up to 80%, as indicated by divertor neutral pressure and D α line emission. Furthermore, each B atom exhibited a trapping capacity of 0.3 D particles during B powder injection at a typical flow rate. The real-time B injection had no wall hysteresis effect on D retention, implying that cumulative B injection and deposited film did not affect long-term D retention. The possible mechanism for D retention is the formation of B-C-O-D compounds and co-deposition between B and D particles during discharges. This investigation would be valuable for evaluating T retention when B is used as wall conditioning material in future fusion reactor devices.

36 MATERIALS SCIENCE↗

Effects of air injection on a turbocharged Teledyne Continental Motors TSIO-360-C engine

Results are presented for tests performed to assess the effects of exhaust manifold injection air flow rate on emissions and on exhaust gas temperature and turbine inlet temperature for a range of engine operating conditions (speed, torque, and fuel-air ratios) of a fuel-injected turbocharged six-cylinder air-cooled Teledyne Continental Motors TSIO-360-C engine. Air injection into the exhaust gas at 80 F resulted in a decrease in hydrocarbons and carbon monoxide while exceeding the maximum recommended turbine inlet temperature of 1650 F at the full rich mixture of the engine. The EPA standards could be met within present turbine inlet temperature limits using commercially available air pumps, provided that the fuel-air ratios were leaned in the taxi, climb, and approach modes.

Cosgrove, D. V.↗