Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “horizontal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Microwave Sintering Lunar Landing Pads & Horizontal Infrastructure

Moon to Mars Planetary Autonomous Construction Technology’s (MMPACT) Microwave Structure Construction Capability (MSCC) team is developing the ability to prepare the lunar regolith and densify it into glass-ceramic landing pads and horizontal infrastructure. Microwave energy will be utilized to densify the lunar regolith. Some of the concept of operations, simulant and synthetic minerals, site preparation, design, microwave sintering, testing, & ancillary instrument technical challenges were listed. A current status of the MSCC project is also provided.

Microwave, sintering, lunar, regolith, landing pad↗

Validation of Simplified Load Equations through Loads Measurement and Modeling of a Small Horizontal-Axis Wind Turbine Tower; NREL (National Renewable Energy Laboratory)

As part of an ongoing effort to improve the modeling and prediction of small wind turbine dynamics, NREL tested a small horizontal axis wind turbine in the field at the National Wind Technology Center (NWTC). The test turbine was a 2.1-kW downwind machine mounted on an 18-meter multi-section fiberglass composite tower. The tower was instrumented and monitored for approximately 6 months. The collected data were analyzed to assess the turbine and tower loads and further validate the simplified loads equations from the International Electrotechnical Commission (IEC) 61400-2 design standards. Field-measured loads were also compared to the output of an aeroelastic model of the turbine. Ultimate loads at the tower base were assessed using both the simplified design equations and the aeroelastic model output. The simplified design equations in IEC 61400-2 do not accurately model fatigue loads. In this project, we compared fatigue loads as measured in the field, as predicted by the aeroelastic model, and as calculated using the simplified design equations.

17 WIND ENERGY↗

Radiographic Imaging with Right/Left Discrimination Using Near-Horizontal Muons

Presentation describes development of a configurable muon detector using gas drift tubes coupled to two 2-foot by 2-foot plastic scintillator paddles oriented in a configuration that collects near-horizontal travelling muon tracks and determines the direction of the muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of horizontal resolution on simulation quality in the Community Atmospheric Model, CAM5.1

We present an analysis of version 5.1 of the Community Atmospheric Model (CAM5.1) at a high horizontal resolution. Intercomparison of this global model at approximately 0.25°, 1°, and 2° is presented for extreme daily precipitation as well as for a suite of seasonal mean fields. In general, extreme precipitation amounts are larger in high resolution than in lower-resolution configurations. In many but not all locations and/or seasons, extreme daily precipitation rates in the high-resolution configuration are higher and more realistic. The high-resolution configuration produces tropical cyclones up to category 5 on the Saffir-Simpson scale and a comparison to observations reveals both realistic and unrealistic model behavior. In the absence of extensive model tuning at high resolution, simulation of many of the mean fields analyzed in this study is degraded compared to the tuned lower-resolution public released version of the model.

58 GEOSCIENCES↗

Future changes in regional precipitation simulated by a half-degree coupled climate model: Sensitivity to horizontal resolution

The global fully coupled half-degree Community Climate System Model Version 4 (CCSM4) was integrated for a suite of climate change ensemble simulations including five historical runs, five Representative Concentration Pathway 8.5 [RCP8.5) runs, and a long Pre-Industrial control run. This study focuses on precipitation at regional scales and its sensitivity to horizontal resolution. The half-degree historical CCSM4 simulations are compared to observations, where relevant, and to the standard 1° CCSM4. Both the halfdegree and 1° resolutions are coupled to a nominal 1° ocean. North American and South Asian/Indian monsoon regimes are highlighted because these regimes demonstrate improvements due to higher resolution, primarily because of better-resolved topography. Agriculturally sensitive areas are analyzed and include Southwest, Central, and Southeast U.S., Southern Europe, and Australia. Both mean and extreme precipitation is discussed for convective and large-scale precipitation processes. Convective precipitation tends to decrease with increasing resolution and large-scale precipitation tends to increase. Improvements for the half-degree agricultural regions can be found for mean and extreme precipitation in the Southeast U.S., Southern Europe, and Australian regions. Climate change responses differ between the model resolutions for the U.S. Southwest/Central regions and are seasonally dependent in the Southeast and Australian regions. Both resolutions project a clear drying signal across Southern Europe due to increased greenhouse warming. As a result, differences between resolutions tied to the representation of convective and large-scale precipitation play an important role in the character of the climate change and depend on regional influences.

58 GEOSCIENCES↗

Measurement of partial vapor pressures of salt mixtures via combined horizontal transpiration and thermogravimetric analysis

A method combining thermogravimetric analysis (TGA) and horizontal transpiration with elemental analysis via inductively coupled plasma mass spectrometry or ion chromatography enabled calculation of partial pressures of individual salts in molten mixtures. TGA quantified total mass loss, while transpiration identified vapor-phase composition. Furthermore, two chloride (NaCl-MgCl 2 , NaCl-MgCl 2 + UCl 3 ) salts and one mixed halide (LiCl-LiF + Li 2 O) salt were analyzed at 750 °C and 550 °C, respectively. NaCl and MgCl 2 vapor pressures were 2.19–2.61 × 10 -4 atm and 2.47–2.48 × 10 -5 atm (dependent upon the identity of the invesitgated mixture); UCl 3 was 1.42 × 10 -7 atm. LiCl and LiF vapor pressures at 550 °C were 1.53 × 10 -6 and 6.32 × 10 -6 atm, respectively. Additionally, the TGA method was validated against values from the literature for unary LiCl and LiF.

36 MATERIALS SCIENCE↗

A Numerical Simulation of Transport Phenomena During the Horizontal Single Belt Casting Process Using an Inclined Feeding System

Horizontal single belt casting (HSBC) has great potential to replace current conventional continuous casting (CCC) processes for sheet metal production, by directly casting 3 to 1 mm sheet for the automobile industry. In the present paper, two-dimensional mathematical models were developed to study transport phenomena, for the case of an inclined wall feeding system for a liquid aluminum wrought alloy (AA6111). Based on the commercial software ANSYS FLUENT 14.5 and user-defined functions, a two-layer turbulence model was used to examine the fluid flow emanating from a slot nozzle set above a water-cooled, high-speed, steel belt. The Volume of Fluid (VOF) method was used to predict the shape of the melt-air interface. A transformed coordinate system (x′, y′) was established in order to analyze the fluid flow on the inclined wall of the feeding system. The total pressure gauge gradient (∂p{sub total}/∂x) was used to describe the behavior of the melt film inside the slot nozzle of the head box. The modeling results show that during the melt film falling process, the total gauge pressure varies within the slot nozzle, which can decrease the stability of the falling film. The first impingement between the falling film and the inclined refractory wall of the feeding system gives rise to a local oscillation, and this influences the stability of the melt film moving downwards. At the rear meniscus position between the inclined wall and the moving belt, there is a clear vibration of the air-melt interface, together with a recirculation zone. The weak vibration of the air-melt interface could be induced by the periodic variation of the melt-air interface. Moreover, the formation of tiny air pockets is predicted. Finally, on the inclined wall of the feeding system, a suitable length of the transition area is needed to avoid over-acceleration of the melt film due to the force of gravity.

36 MATERIALS SCIENCE↗

Numerical Simulation of the Effects of Horizontal and Vertical EMBr on Jet Flow and Mold Level Fluctuation in Continuous Casting

In this article, a new type of electromagnetic braking (EMBr), named vertical EMBr (V-EMBr) was introduced in the continuous casting process. In order to investigate its capability and applicability, the impacts of horizontal and vertical EMBrs on the flow pattern in a continuous casting mold were simulated by means of an implemented Reynolds-averaged Navier–Stokes (RANS) SST k–ω turbulence model. The characteristics of electromagnetic field and flow field inside a 1450 mm × 230 mm mold with Ruler-EMBr and V-EMBr have been compared. The numerical simulation results indicate that the static magnetic field generated by Ruler-EMBr can cover the main part of the discharging jet flow, which has a better control of the flow pattern in lower part of the mold. The static magnetic field generated by V-EMBr can cover both the vicinity of the mold narrow faces and the impingement region of the jet flow, which can effectively control the liquid steel flow in the upper recirculation zone. The parametric study also shows that the large vortices beneath the jet flow can be almost completely eliminated at an optimized magnetic flux density with Ruler-EMBr. In addition, the surface velocity and steel/slag interface fluctuation can be suppressed with the application of V-EMBr to acceptable values even with a wide variation of SEN port angles. It is estimated that to reach the same level of braking effect on the upper recirculation flow, a magnetic flux density of 0.1 T is sufficient for V-EMBr, while 0.2 T is needed for Ruler-EMBr. Based on the results, a second-generation V-EMBr has been developed, which combines both of the merits of Ruler-EMBr and V-EMBr.

36 MATERIALS SCIENCE↗

Mixing Behaviors in the Horizontal Bath Smelting Furnaces

In the copper smelting process, sulfides are oxidized by the injected oxygen in the liquid bath. The reaction rate is predominantly determined by the stirring conditions of the bath. Single lance mixing experiments were carried out in a horizontal cylindrical vessel with different gas blown angles to simulate the smelting furnaces gas blown from side and bottom. The mixing behaviors were studied by quantifying the mixing time of the bath under different conditions. The results show that the increase of gas flow rate decreases the mixing time rapidly before it reaches a plateau. In the side blown furnace, mixing time was also shortened significantly by increasing bath height up to certain values, followed by minor promotions of mixing time if further increasing the bath heights. In comparison to the side blown process with the same gas flow conditions, the bottom blown process took more time for the bath to reach homogeneity under the same operating conditions.

36 MATERIALS SCIENCE↗

Evolutions of the Micro- and Macrostructure and Tensile Property of Cu-15Ni-8Sn Alloy During Electromagnetic Stirring-Assisted Horizontal Continuous Casting

The present study investigates the evolution of the micro- and macrostructure and tensile property of the Cu-15Ni-8Sn (weight percent) alloy prepared by horizontal continuous casting and electromagnetic stirring (EMS). The results show that the application of EMS is beneficial for grain refinement and for microstructure transformation from the dendrite to the rosette structure and that it leads to a significant improvement in the tensile property. The forced flow induced by EMS homogenizes the temperature field ahead of the solid-liquid interface, disturbing the heat flow direction and resulting in the columnar to equiaxed transition. The grain refinement under different electromagnetic stirring frequencies is mainly derived from the homogenization of the temperature and the remelting of dendritic arms. In addition, the evolution of the tensile property with and without EMS is discussed from the perspective of fracture mode and fine-grain strengthening.

36 MATERIALS SCIENCE↗

Modeling residence-time distribution in horizontal screw hydrolysis reactors

The dilute-acid thermochemical hydrolysis step used in the production of liquid fuels from lignocellulosic biomass requires precise residence-time control to achieve high monomeric sugar yields. Difficulty has been encountered reproducing residence times and yields when small batch reaction conditions are scaled up to larger pilot-scale horizontal auger-tube type continuous reactors. A commonly used naive model estimated residence times of 6.2-16.7 min, but measured mean times were actually 1.4-2.2 the estimates. Here, this study investigated how reactor residence-time distribution (RTD) is affected by reactor characteristics and operational conditions, and developed a method to accurately predict the RTD based on key parameters. Screw speed, reactor physical dimensions, throughput rate, and process material density were identified as major factors affecting both the mean and standard deviation of RTDs. The general shape of RTDs was consistent with a constant value determined for skewness. The Peclet number quantified reactor plug-flow performance, which ranged between 20 and 357.

09 BIOMASS FUELS↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

On falling film evaporator – A review of mechanisms and critical assessment of correlation on a horizontal tube bundle with updated development

Optimization of the energy efficiency and reduction of the greenhouse gas emission for the heat pump system is imperative to meet the net-zero goals at 2050. Chillers with falling film evaporator design not only possess better system performance but also contain less refrigerant inventory. Hence, accurate prediction of the evaporator performance is pivotal especially when charged with low-GWP refrigerant. Here, the study reviews the correlations for falling film evaporator with a horizontal tube bundle configuration. The major efforts of this study include four tasks: (a) literature review of the experimental studies and available empirical correlations; (b) comprehensive discussion of the falling film evaporation heat transfer mechanism; (c) development of a new rationally based correlation based on available literature; and (d) comparison of different correlations based on the existing data. The collected data includes 4114 data points from 8 sources, 6 refrigerants (R-600a, R-290, R-245fa, R-134a, R-1234ze(E), R-123), 5 types of the tubes (Plain, Turbo-GII-HP, GEWA-B, Low-fin, High-Flux), liquid Weber number from 2.2 × 10 –6 to 0.7, imposed vapor Weber number from 0 to 37.2, heat flux from 2.5 to 151.5 kW/m 2 , and film Reynolds number from 1 to 3159.8. The new correlation gives a MAD of 28.3%, and an R 2 of 0.86. Yet, the developed correlation considers various heat transfer mechanisms, including the transition point from falling film evaporation to the nucleate boiling, local evaporation, dry-out, mist flow, imposed flow, and enhanced tube effects.

42 ENGINEERING↗

Universal correlation for falling film evaporation on a horizontal plain tube

Falling film evaporators are widely used in many industrial sectors, such as desalination, refrigeration & air-conditioning, and chemical processes. The heat transfer correlations suitable for wider operating conditions and various refrigerants are useful for designing falling film evaporators. Although many researchers developed the correlation for their own experimental data, there is a limited universal correlation for falling film evaporators. In addition, the dry-out effects were not considered in the available universal correlations. Here, therefore, this study proposes a new correlation for falling film evaporation on a single horizontal plain tube, which includes nucleate boiling, film evaporation, and dry-out effects. The proposed correlation covers a wider range of operating conditions (Heat flux is of 2.5–168kWm -2 , and film Reynolds number is up to 3500), various refrigerants (R134a, R245fa, R1234ze(E), R123, R32, R410A, R290, and R600a), and the large number of experimental data (1101 data in total). The proposed correlation is validated against the available standard correlation with regard to mean absolute deviation (MAD) and R 2 values. The MAD of the new correlation is about 10%, respectively, which is the lowest among other correlations. Similarly, the R 2 showed a value of 0.92, which is the highest compared to the existing correlations. A simplified correlation is also proposed.

42 ENGINEERING↗

Comparing numerical accuracy and stability for different horizontal discretizations in MPAS-Ocean

This manuscript investigates the effectiveness of two possible horizontal discretizations for the global ocean model MPAS-Ocean, both applied to Spherical Centroidal Voronoi Tessellations (SCVTs). The first discretization is TRiSK, a C-grid, finite-volume method, that possesses many desirable mimetic properties, but has a low order accuracy. The second discretization was introduced for the first time by Peixoto (2016), and consists of modifications to the TRiSK scheme designed to achieve at least first-order accuracy in the L ∞ norm, with the loss of some of the mimetic properties. Tests on shallow-water and primitive-equation models show that the scheme due to Peixoto is indeed more accurate, but presents stability issues with respect to TRiSK. Here, TRiSK is indeed found to be often more stable in time and more robust with respect to errors in the geometric properties of the grid.

97 MATHEMATICS AND COMPUTING↗

Sensitivity of Mountain Hydroclimate Simulations in Variable-Resolution CESM to Microphysics and Horizontal Resolution

Mountains are natural dams that impede atmospheric moisture transport and water towers that cool, condense, and store precipitation. They are essential in the western United States where precipitation is seasonal, and snowpack is needed to meet water demand. With anthropogenic climate change increasingly threatening mountain snowpack, there is a pressing need to better understand the driving climatological processes. However, the coarse resolution typical of modern global climate models renders them largely insufficient for this task, and signals a need for an advanced strategy. This paper continues the assessment of variable-resolution in the Community Earth System Model (VR-CESM) in modeling mountain hydroclimatology to understand the role of grid-spacing at 55, 28, 14, and 7 km and microphysics, specifically the Morrison and Gettelman (2008, MG1, https://doi.org/10.1175/2008JCLI2105.1) scheme versus the Gettelman and Morrison (2015, MG2, https://doi.org/10.1175/JCLI-D-14-00102.1) scheme. Eight VR-CESM simulations were performed from 1999 to 2015 with the F_AMIP_CAM5 component set, which couples the atmosphere-land models and prescribes ocean data. Refining horizontal grid-spacing from 28 to 7 km with the MG1 scheme did not improve the simulated mountain hydroclimatology. Substantial improvements occurred with the use of MG2 at grid-spacings ≤28 km compared to MG1 as shown with subsequent statistics. Average SWE bias diminished by 9.4X, 4.9X, and 3.5X from 55 to 7 km. The range in minimum (maximum) DJF spatial correlations increased by 0.1–0.2 in both precipitation and SWE. Mountain windward/leeward distributions and elevation profiles improved across hydroclimate variables, however not always with model resolution alone. Disconcertingly, all VR-CESM simulations exhibited a systemic mountain cold bias that worsened with elevation and will require further examination.

58 GEOSCIENCES↗

Horizontal Resolution Sensitivity of the Simple Convection-Permitting E3SM Atmosphere Model in a Doubly-Periodic Configuration

We develop a doubly periodic version of the Simple Convection-Permitting E3SM Atmosphere Model (SCREAM) to provide an efficient configuration for this global convection permitting model (GCPM), akin to a single column model often found in conventional general circulation models. The design details are explained, in addition to the extensive case library associated with the doubly periodic SCREAM (DP-SCREAM) configuration. We demonstrate that doubly periodic cloud resolving models are useful tools to explore the horizontal resolution sensitivity of GCPMs, in addition to replicating biases seen in the global models. Using DP-SCREAM, we show that SCREAM exhibits behaviors of a scale aware model as it is able to naturally partition between sub-grid scale (SGS) and resolved vertical transport across the gray zone of turbulence. We show that SCREAM is reasonably scale insensitive when run at resolutions from 1 to 5 km, but can exhibit sensitivity, particularly for the shallow convective regime, when run at resolutions approaching that of large eddy simulations. We conclude that SGS parameterization improvements are likely needed to reduce this scale sensitivity.

54 ENVIRONMENTAL SCIENCES↗