Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high gradient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Toward an effective use of laser-driven very high energy electrons for radiotherapy: Feasibility assessment of multi-field and intensity modulation irradiation schemes

Radiotherapy with very high energy electrons has been investigated for a couple of decades as an effective approach to improve dose distribution compared to conventional photon-based radiotherapy, with the recent intriguing potential of high dose-rate irradiation. Its practical application to treatment has been hindered by the lack of hospital-scale accelerators. High-gradient laser-plasma accelerators (LPA) have been proposed as a possible platform, but no experiments so far have explored the feasibility of a clinical use of this concept. We show the results of an experimental study aimed at assessing dose deposition for deep seated tumours using advanced irradiation schemes with an existing LPA source. Measurements show control of localized dose deposition and modulation, suitable to target a volume at depths in the range from 5 to 10 cm with mm resolution. The dose delivered to the target was up to 1.6 Gy, delivered with few hundreds of shots, limited by secondary components of the LPA accelerator. Measurements suggest that therapeutic doses within localized volumes can already be obtained with existing LPA technology, calling for dedicated pre-clinical studies.

59 BASIC BIOLOGICAL SCIENCES↗

Design of a high-power, high-gain, 2nd harmonic, 22.848 GHz gyroklystron

In this paper we consider the design of a four-cavity, high-gain K-band gyroklystron experiment for high gradient structure testing. The frequency doubling gyroklystron utilizes a beam voltage of 500 kV and a beam current of 200 A from a magnetron injection gun (MIG) originally designed for a lower-frequency device. The microwave circuit features input and gain cavities in the circular TE{sub 011} mode and penultimate and output cavities that operate at the second harmonic in the TE{sub 021} mode. We investigate the MIG performance and study the behavior of the circuit for different values of perpendicular to parallel velocity ratio (α= V{sub ⊥}/ V{sub z}). This microwave tube is expected to be able to produce at least 20 MW of power in 1μs pulses at a repetition rate of at least 120 Hz. A maximum efficiency of 26% and a large signal gain of 58 dB under zero-drive stable conditions were simulated for a velocity ratio equal to 1.35.

43 PARTICLE ACCELERATORS↗

Observation of multipactor suppression in a dielectric-loaded accelerating structure using an applied axial magnetic field

Efforts by a number of institutions to develop a Dielectric-Loaded Accelerating (DLA) structure capable of supporting high gradient acceleration when driven by an external radio frequency source have been ongoing over the past decade. Single surface resonant multipactor has been previously identified as one of the major limitations on the practical application of DLA structures in electron accelerators. In this paper, we report the results of an experiment that demonstrated suppression of multipactor growth in an X-band DLA structure through the use of an applied axial magnetic field. This represents an advance toward the practical use of DLA structures in many accelerator applications.

43 PARTICLE ACCELERATORS↗

Physical principles of microwave assisted magnetic recording

While the basic physics of Microwave Assisted Magnetization Reversal (MAMR) phenomenon is well established both theoretically and experimentally, its application in a practical magnetic recording environment was so far studied primarily with the help of micromagnetic recording models. In this work, we instead attempt to use analytical formulation and simple numerical models to understand the main challenges as well as benefits that are associated with such a system. It appears that the main difference between the previously introduced theory [G. Bertotti et al., Phys. Rev. Lett. 86, 724 (2001); K. Rivkin et al., Appl. Phys. Lett. 92, 153104 (2008); S. Okamoto et al., J. Appl. Phys. 107, 123914 (2010).] and recording environment is that both the RF and DC magnetic fields are applied at a substantial angle to the anisotropy axis. While the associated symmetry breaking prevents one from describing the reversal process explicitly, it is possible to approximate the solutions well enough to satisfactorily match numerical models both in the case of wire and Spin Torque Oscillator generated RF fields. This approach allows for physical explanation of various effects associated with MAMR such as high gradient of writeable anisotropy and reduction of track width, and offers a clear guidance regarding future optimization of MAMR recording.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of voxel size on dose distribution in Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

Recently, Monte Carlo (MC) calculation method has reported as the most accurate method of predicting dose distributions in radiotherapy. The MC code system (especially DOSXYZnrc) has been used to investigate the different voxel (volume elements) sizes effect on the accuracy of dose distributions. To investigate this effect on dosimetry parameters, calculations were made with three different voxel sizes. The effects were investigated with dose distribution calculations for seven voxel sizes: 1 × 1 × 0.1 cm{sup 3}, 1 × 1 × 0.5 cm{sup 3}, and 1 × 1 × 0.8 cm{sup 3}. The 1 × 10{sup 9} histories were simulated in order to get statistical uncertainties of 2%. This simulation takes about 9-10 hours to complete. Measurements are made with field sizes 10 × 10 cm2 for the 6 MV photon beams with Gaussian intensity distribution FWHM 0.1 cm and SSD 100.1 cm. MC simulated and measured dose distributions in a water phantom. The output of this simulation i.e. the percent depth dose and dose profile in d{sub max} from the three sets of calculations are presented and comparisons are made with the experiment data from TTSH (Tan Tock Seng Hospital, Singapore) in 0-5 cm depth. Dose that scored in voxels is a volume averaged estimate of the dose at the center of a voxel. The results in this study show that the difference between Monte Carlo simulation and experiment data depend on the voxel size both for percent depth dose (PDD) and profile dose. PDD scan on Z axis (depth) of water phantom, the big difference obtain in the voxel size 1 × 1 × 0.8 cm{sup 3} about 17%. In this study, the profile dose focused on high gradient dose area. Profile dose scan on Y axis and the big difference get in the voxel size 1 × 1 × 0.1 cm{sup 3} about 12%. This study demonstrated that the arrange voxel in Monte Carlo simulation becomes important.

61 RADIATION PROTECTION AND DOSIMETRY↗

Passive Longitudinal-Phase-Space Tailoring of Non-Ultrarelativistic Beams with Dielectric-Lined Waveguides

To date conventional use of dielectric-lined waveguides (DLWs) has mainly concerned high-gradient acceleration. In this paper we investigate an alternative use of such waveguides to impressed wakefield-induced energy correlations on non-ultra-relativistic beams. These correlations are shown to produce density modulations as the beam drifts in a free space. We explore several schemes with a single or multiple DLW structures which can lead to passive compressions and to the formation of sub-picosecond bunch trains. We finally suggest the possible use of multiple structures to bunch the beam at higher frequencies using a scheme similar to a two-stage echo enabled harmonic generation.

43 PARTICLE ACCELERATORS↗

Laser-driven semiconductor switch for generating nanosecond pulses from a megawatt gyrotron

A laser-driven semiconductor switch (LDSS) employing silicon (Si) and gallium arsenide (GaAs) wafers has been used to produce nanosecond-scale pulses from a 3 μs, 110 GHz gyrotron at the megawatt power level. Photoconductivity was induced in the wafers using a 532nm laser, which produced 6 ns, 230 mJ pulses. Irradiation of a single Si wafer by the laser produced 110 GHz RF pulses with a 9 ns width and >70% reflectance. Under the same conditions, a single GaAs wafer yielded 24 ns 110 GHz RF pulses with >78% reflectance. For both semiconductor materials, a higher value of reflectance was observed with increasing 110 GHz beam intensity. Using two active wafers, pulses of variable length down to 3 ns duration were created. The switch was tested at incident 110 GHz RF power levels up to 600 kW. A 1-D model is presented that agrees well with the experimentally observed temporal pulse shapes obtained with a single Si wafer. The LDSS has many potential uses in high power millimeter-wave research, including testing of high-gradient accelerator structures.

43 PARTICLE ACCELERATORS↗

Advances in physics understanding of high poloidal beta regime toward steady-state operation of CFETR

Experimental and modeling investigations of the high βp scenarios on the DIII-D and EAST tokamaks show advantages in high energy confinement, avoidance of n = 1 MHD, and core-edge integration with reduced heat flux, making this scenario an attractive option for CFETR steady-state operation. Experiments show that plasmas with high confinement and high density can be achieved with neutral beam injection on DIII-D (β p ~ 2.2, β N ~ 3.5, f BS ~ 50%, f Gw ~ 1.0, H 98y2 ~ 1.5) and pure RF power on EAST (β P ~ 2.0, β N ~ 1.6, f BS ~ 50%, f Gw ~ 0.8, H 98y2 > 1.3). By tailoring the current density profile, a q-profile with local (off-axis) negative shear is achieved that yields improved confinement and MHD stability. Transport analysis and simulation suggest that the combination of high density gradient and high Shafranov shift allows turbulence stabilization and higher confinement. Using on-axis ECH injection, tungsten accumulation is avoided on EAST, and this is reproduced in modeling. Reduced heat flux (by >40%) and maintenance of high core confinement is achieved with active feedback control of the radiated divertor, an important result for long pulse operation in tokamaks. In conclusion, the improved physics understanding and validated modeling tools are used to design a 1GW steady-state scenario for CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser–solid interaction studies enabled by the new capabilities of the iP2 BELLA PW beamline

The new capabilities of the short focal length, high intensity beamline, named iP2, at the BELLA Center will extend the reach of research in high energy density science, including accessing new regimes of high gradient ion acceleration and their applications. This 1 Hz system will provide an on-target peak intensity beyond 1021 W/cm2 with a temporal contrast ratio of <10−14 that will be enabled by the addition of an on-demand double plasma mirror setup. An overview of the beamline design and the main available diagnostics are presented in this paper as well as a selection of accessible research areas. As a demonstration of the iP2 beamline's capabilities, we present 3D particle-in-cell simulations of ion acceleration in the magnetic vortex acceleration regime. The simulations were performed with pure hydrogen targets and multi-species targets. Proton beams with energy up to 125 MeV and an approximately 12° full angle emission are observed as preplasma scale length and target tilt are varied. The number of accelerated protons is on the order of 109/MeV/sr for energies above 60 MeV.

Hakimi, Sahel (ORCID:000000022493564X)↗

A cryogenically cooled 200 kV DC photoemission electron gun for ultralow emittance photocathodes

Novel photocathode materials like ordered surfaces of single crystal metals, epitaxially grown high quantum efficiency thin films, and topologically non-trivial materials with dirac cones show great promise for generating brighter electron beams for various accelerator and ultrafast electron scattering applications. Despite several materials being identified as brighter photocathodes, none of them have been tested in electron guns to extract electron beams due to technical and logistical challenges. In this paper, we present the design and commissioning of a cryocooled 200 kV DC electron gun that is capable of testing a wide variety of novel photocathode materials over a broad range of temperatures from 298 to 35 K for bright electron beam generation. This gun is designed to enable easy transfer of the photocathode to various standard ultra-high-vacuum surface diagnostics and preparation techniques, allowing a full characterization of the dependence of beam brightness on the photocathode material and surface properties. We demonstrate the development of such a high-voltage, high-gradient gun using materials and equipment that are easily available in any standard university lab, making the development of such 200 kV electron guns more accessible.

Instruments & Instrumentation↗

A hybrid six-dimensional muon cooling channel using gas filled rf cavities

We describe an alternative cooling approach to prevent rf breakdown in magnetic fields that simultaneously reduces all six phase-space dimensions of a muon beam. In this process, cooling is accomplished by reducing the beam momentum through ionization energy loss in discrete absorbers and replenishing the momentum loss only in the longitudinal direction through gas-filled rf cavities. The advantage of gas filled cavities is that they can run at high gradients in magnetic fields without breakdown. Using this approach, we show that our channel can achieve a decrease of the 6-dimensional phase-space volume by several orders of magnitude. With the aid of numerical simulations, we demonstrate that the transmission of our proposed channel is comparable to that of an equivalent channel with vacuum rf cavities. Finally, we discuss the sensitivity of the channel performance to the choice of gas and operating pressure.

43 PARTICLE ACCELERATORS↗

Genomic insights into local adaptation and migration success in reintroduced Coho Salmon of the Wenatchee River basin

ABSTRACT Objective Reintroduction of salmonids into regions where they have been extirpated is a common conservation strategy that is often implemented through natural recolonization, translocation of natural populations, or hatchery-based programs. Locally adapting to specific environmental conditions is critical for long-term population viability, particularly for species like Coho Salmon Oncorhynchus kisutch, which face diverse selective pressures during their migration. This study focused on the mid-Columbia River Coho Salmon reintroduction program managed by Yakama Nation Fisheries, which has successfully reintroduced Coho Salmon into the Wenatchee and Methow River basins, Washington. Notably, these populations have adapted to the longer migration route than those in the founding stock, with selection favoring individuals with an earlier arrival time and that can navigate a 15-km, high-gradient canyon to reach optimal spawning grounds. The objectives of this study were to investigate whether specific genomic regions are under selection for traits associated with return location and timing in Coho Salmon. Methods Low-coverage whole-genome resequencing data were used to screen for genomic regions associated with the phenotypes of interest. Results A weak polygenic signal in female Coho Salmon was found to be associated with return group, with a subset of candidate adaptive regions occurring across eight chromosomes. Conclusions These findings provide insights into the genomic mechanisms underlying local adaptation in reintroduced salmon populations and inform broodstock selection strategies aimed at promoting natural production and long-term population sustainability.

Horn, Rebekah L.↗

Single shot cathode transverse momentum imaging in high brightness photoinjectors

In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode rf guns. By tuning the gun solenoid focusing, the electrons’ transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons’ transverse momenta. Both simulations and proof of principle experiments are reported.

43 PARTICLE ACCELERATORS↗

Femtosecond MeV Electron Energy-Loss Spectroscopy

Pump-probe electron energy-loss spectroscopy (EELS) with femtosecond temporal resolution will be a transformative research tool for studying nonequilibrium chemistry and electronic dynamics of matter. Here in this article, we propose a concept of femtosecond EELS utilizing mega-electron-volt electron beams from a radio-frequency (rf) photocathode source. The high acceleration gradient and high beam energy of the rf gun are critical to the generation of 10-fs electron beams, which enables an improvement of the temporal resolution by more than 1 order of magnitude beyond the state of the art. In our proposal, the “referencebeam technique” relaxes the energy stability requirement of the rf power source by roughly 2 orders of magnitude. The requirements for the electron-beam quality, photocathode, spectrometer, and detector are also discussed. Supported by particle-tracking simulations, we demonstrate the feasibility of achieving subelectron- volt energy resolution and approximately 10-fs temporal resolution with existing or near-future hardware performance.

43 PARTICLE ACCELERATORS↗

Tunable High-Intensity Electron Bunch Train Production Based on Nonlinear Longitudinal Space Charge Oscillation

High-intensity trains of electron bunches with tunable picosecond spacing are produced and measured experimentally with the goal of generating terahertz (THz) radiation. By imposing an initial density modulation on a relativistic electron beam and controlling the charge density over the beam propagation, density spikes of several-hundred-ampere peak current in the temporal profile, which are several times higher than the initial amplitudes, have been observed for the first time. We also demonstrate that the periodic spacing of the bunch train can be varied continuously either by tuning launching phase of a radiofrequency gun or by tuning the compression of a downstream magnetic chicane. Narrow-band coherent THz radiation from the bunch train was also measured with μJ-level energies and tunable central frequency of the spectrum in the range of ~0.5 to 1.6 THz. Our results pave the way towards generating mJ-level narrow-band coherent THz radiation and driving high-gradient wakefield-based acceleration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Characterization of Electron-Beam-Driven Wakefield Modes in a Dielectric-Woodpile Cartesian Symmetric Structure

Photonic structures operating in the terahertz (THz) spectral region enable the essential characteristics of confinement, modal control, and electric field shielding for very high gradient accelerators based on wakefields in dielectrics. We report in this paper an experimental investigation of THz wakefield modes in a three-dimensional photonic woodpile structure. Selective control in exciting or suppressing of wakefield modes with a nonzero transverse wave vector is demonstrated by using drive beams of varying transverse ellipticity. Additionally, we show that the wakefield spectrum is insensitive to the offset position of strongly elliptical beams. Finally, these results are consistent with analytic theory and three-dimensional simulations and illustrate a key advantage of wakefield systems with Cartesian symmetry: the suppression of transverse wakes by elliptical beams.

43 PARTICLE ACCELERATORS↗

Test of Optimized 120-mm LARP Nb 3 Sn Quadrupole Coil Using Magnetic Mirror Structure

The U.S. Large Hadron Collider accelerator research program is developing a new generation of large-aperture high-field quadrupoles based on Nb 3 Sn conductor for the high-luminosity upgrade of the Large Hadron Collider. Tests of the first series of 120-mm-aperture high-gradient quadrupole (HQ) coils revealed the necessity for further optimization of the coil design and fabrication process. Modifications in coil design were gradually implemented in two HQ coils previously tested at Fermi National Accelerator Laboratory using a magnetic mirror structure (HQM01 and HQM02). This paper describes the construction and test of an HQ mirror model with a coil of optimized design and with an interlayer resistive core in the conductor. The cable for this coil was made of a smaller diameter strand, providing more room for coil expansion during reaction. The 0.8-mm strand, used in all previous HQ coils, was replaced with a 0.778-mm Nb 3 Sn strand of RRP 108/127 subelement design. The coil was instrumented with voltage taps, heaters, and strain gauges to monitor mechanical and thermal properties and quench performance of the coil

43 PARTICLE ACCELERATORS↗

Design of an Achromatic Superconducting Magnet for a Proton Therapy Gantry

Recent studies have shown that strong, alternating focusing magnets can be used to greatly increase the momentum acceptance of hadron therapy gantries. With the high gradients achievable with superconducting magnets a level of momentum acceptance can be reached which may have significant implications to medical gantries and to the introduction of superconducting technology in this area. The design of such a superconducting magnet system for a proton therapy gantry will be presented. The Canted-Cosine-Theta concept is extended to a curved magnet system generating the desired bending and alternating focusing fields for the achromatic optics. In conclusion, magnetic, structural, and thermal analysis of this design is presented along with preliminary efforts towards fabrication and assembly of the curved magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗