Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat transfer coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Deflagration to Detonation Transition Update: XDDT Code Modularization

A legacy FORTRAN 77 implementation of the Baer–Nunziato two-phase mixture theory for deflagration-to-detonation transition (DDT) in reactive granular materials—hereafter the XDDT (eXplosive DDT) code—has been modularized to Fortran 90 with modular structure, external input files, and adaptive mesh capability. During validation, two code defects were identified and corrected: an inconsistency in the nodal solid pressure evaluation and a nonphysical burn-front tracking criterion. The ignition criterion was also corrected to use the granular surface temperature from the interface heat transfer model, matching the original Baer implementation. An initial attempt to validate against Figure 3 of the original Baer and Nunziato (1986) paper revealed that the code’s detonation velocity on a 201-node mesh (5.5 km/s) was approximately 21% below the expected Chapman–Jouguet value for 70% TMD HMX (∼7 km/s). Validation was redirected to the piston-driven DDT experiments of McAfee et al. (1989), Shot B-9036, for which well-characterized ionization-pin data are available. With the compaction-burn coefficient calibrated to 𝐶 𝛼 = 75, the XDDT code reproduces the DDT transition time to within 0.4% and produces a steady-state detonation velocity within 4% of the McAfee experimental value of 6.36 km/s. The burn model was generalized to support pressure-dependent exponents, enabling application to nitrocellulose-based ball propellants (TS3659) with a cube-root pressure dependence. Validation against the Sandusky/Baer PDC82 piston-impact experiment yielded a reactive wave velocity of 2.3–2.8 km/s, in good agreement with the experimental value of ∼2.2 km/s, and wave coalescence within 5% of the experimental timing. The mathematical model, input parameter requirements, and a roadmap for extending XDDT to PETN with an autocatalytic burn model are presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Automated reaction kinetics and network exploration (Arkane): A statistical mechanics, thermodynamics, transition state theory, and master equation software

The open-source statistical mechanics software described here, Arkane–Automated Reaction Kinetics and Network Exploration–facilitates computations of thermodynamic properties of chemical species, high-pressure limit reaction rate coefficients, and pressure-dependent rate coefficient over multi-well molecular potential energy surfaces (PES) including the effects of collisional energy transfer on phenomenological kinetics. Arkane can use estimates to fill in information for molecules or reactions where quantum chemistry information is missing. The software solves the internal energy master equation for complex unimolecular reaction systems. Inputs to the software include converged electronic structure computations performed by the user using a variety of supported software packages (Gaussian, Molpro, Orca, TeraChem, Q-Chem, Psi4). The software outputs high-pressure limit rate coefficients and pressure-dependent phenomenological rate coefficients, as well as computed thermodynamic properties (enthalpy, entropy, and constant pressure heat capacity) with added energy corrections. Some of the key features of Arkane include treatment of 1D, 2D or ND hindered internal rotation modes, treatment of free internal rotation modes, quantum tunneling effect consideration, transition state theory (TST) and Rice-Ramsperger-Kassel-Marcus (RRKM) rate coefficient computations, master equation solution with four implemented methods, inverse-Laplace transform of high-pressure limit rate coefficients into the energy domain, energy corrections based on bond-additivity or isodesmic reactions, automated and efficient PES exploration, and PES sensitivity analysis. The present work describes the design of Arkane, how it should be used, and refers to the theory that it employs. Arkane is distributed via the RMG-Py software suite (https://github.com/ReactionMechanismGenerator/RMG-Py).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and application of ReaxFF methodology for understanding the chemical dynamics of metal carbonates in aqueous solutions

A new ReaxFF reactive force field has been developed for metal carbonate systems including Na + , Ca 2+ , and Mg 2+ cations and the CO 3 2– anion. This force field is fully transferable with previous ReaxFF water and water/electrolyte descriptions. The Me–O–C (Me = metal) three-body valence angle parameters and Me–C non-reactive parameters of the force field have been optimized against quantum mechanical calculations including equations of state, heats of formation, heats of reaction, angle distortions and vibrational frequencies. The new metal carbonate force field has been validated using molecular dynamics simulations to study the solvation and reactivity of metal and carbonate ions in water at 300 K and 700 K. The coordination radius and self-diffusion coefficient show good consistency with existing experimental and simulation results. The angular distribution analysis explains the structural preference of carbonate ions to form carbonates and bicarbonates, where Na + predominantly forms carbonates due to weaker angular strain, while Ca 2+ and Mg 2+ prefer to form bicarbonate monodentate in nature. Residence time distribution analyses on different systems reveal the role of ions in accelerating and decelerating the dynamics of water and carbonate ions under different thermodynamic conditions. The formation and dissolution of bicarbonates and carbonates in solution were explored on the basis of the protonation capability in different systems. Here, the nucleation phenomenon of metal carbonates at ambient and supercritical conditions is explained from the perspective of cluster formation over time: Ca 2+ ions can form prenucleation clusters at ambient temperature but show saturation with increasing temperature, whereas Na + and Mg 2+ ions show a rapid increase in cluster size and amount upon increasing time and temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding flow dynamics in membrane distillation: Effects of reactor design on polarization

Optimization and design of full-scale membrane distillation (MD) systems usually require Sherwood and Nusselt correlations that are developed from lab-scale systems. However, entrance effects in lab-scale systems can significantly impact heat, mass and momentum transfer in the reactor, therefore affect the accuracy of the developed experimental Sherwood and Nusselt correlations. Here, Computational Fluid Dynamics (CFD) simulations using OpenFOAM are performed to understand the effects of right-angled bends and inlet design on flow dynamics, temperature and concentration polarization in MD systems. Simulation results show that the presence of right-angled bends and inlets with sudden expansions lead to the formation of Dean vortices. Dean vortices enhance perpendicular mixing in MD systems and reduce both temperature and concentration polarization. Temperature and concentration polarization coefficients in MD systems with right-angled bends and inlets with sudden expansions vary significantly for the same volumetric flow rate. Our studies show that lab-scale systems with the same volumetric flow rate but different designs lead to significantly different Nusselt and Sherwood correlations. Here, this study demonstrates the importance of CFD-informed design of lab-scale systems to minimize entrance effects and suppress Dean vortices for consistent model development and calibration across multiple scales.

42 ENGINEERING↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Process Modeling of CO 2 Absorption with Monoethanolamine Aqueous Solutions Using Rotating Packed Beds

A first-principle process simulation model is presented for the chemical absorption of carbon dioxide (CO 2 ) with monoethanolamine (MEA) aqueous solutions using rotating packed beds (RPB). Built on a proven rate-based packed bed absorber model, the RPB model rigorously simulates the phase and chemical equilibria at the vapor-liquid interface, the heat and mass transfer across the gas and liquid films, the fast reactions between MEA and CO 2 in the liquid film, and the RPB hydraulics. Here, estimation of the mass transfer rate across the liquid film is central to accurate simulation of the CO 2 absorption process with MEA aqueous solutions. We show that the literature lab-scale RPB data for CO 2 removal efficiency can be satisfactorily correlated by introducing a correction factor for the effective packing surface area predicted by the Onda correlation. Given the validated RPB model, we further show that, among the gas-phase mass transfer coefficient, the liquid-phase mass transfer coefficient, and the reaction rate constant for the reaction between amine and CO 2 , the reaction rate constant is the controlling step with the highest potential to enhance the CO 2 absorption performance in RPB.

42 ENGINEERING↗

First-principles investigation of the thermophysical properties of NaCl, PuCl 3 , and NaCl-PuCl 3 Molten salts

Molten salts have a variety of applications that span the nuclear and solar industries, and which involve thermal storage and heat transfer. There is a present knowledge gap in the thermophysical properties of molten salts, which limits the readiness level of molten salt applications. This is especially pertinent for molten salt reactors where the fissile material is dissolved within the molten salt. Ab initio molecular dynamics is a common method employed to investigate the structural and thermophysical properties at elevated temperatures. NaCl-PuCl 3 is a candidate fuel salt in molten salt reactors. The scope of this study is to investigate the seven unique compositions and a range of temperatures of NaCl-PuCl 3 and calculate the density, heat capacity, compressibility, enthalpy of mixing, and coefficient of thermal expansion. Within this work, the van der Waals (vdW) interactions are primarily handled with the vdW-DF2 functional but spot-checked with both the dDsC and DFT-D3 methods. The calculated densities are in good agreement with the NaCl and the eutectic compositions, and no experimental values exist for PuCl 3 at these temperatures. The densities are fit to a first-order Redlich-Kister expansion as a function of both composition and temperature. The heat capacity in the literature is scattered but the calculated values agree well with one of the experimental results. Here, the heat capacity increases as a linear function with respect to concentration at a rate of about 7.5 J/mol-K per 10 mol% PuCl 3 .

36 MATERIALS SCIENCE↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power

Molten salts are considered as candidate heat transfer fluids and thermal energy storage media for next generation concentrating solar power (CSP). A molten salt circulates inside the piping and heat exchanger and also functions as a lubricant for the sleeve bearings of the CSP pump. Furthermore, wear- and corrosion-resistant high-temperature bearing materials are critical for the pump efficiency and durability. This study evaluated the tribological performance of candidate bearing materials in lubrication of a molten chloride salt mixture (20% NaCl + 40% MgCl 2 + 40% KCl) at 750 °C in an inert argon gas (a simulative CSP pump environment). Six ceramic-alloy pairs were tested, zirconia and silicon nitride against Haynes 244, Hastelloy C276, and Tribaloy T900 alloy, and ranked by the friction coefficient and wear loss. Characterization of worn surfaces suggested the wear mechanism as a combination of abrasion, adhesion, and tribocorrosion. Results from this study provide fundamental insight for the development and selection of bearing materials for molten salt powered CSP pumps.

14 SOLAR ENERGY↗

CFD modeling and simulation for corrosive wear of refractory in molten slag

The development of high-wear resistant refractories having minimal production costs is facilitated by characterizing the wear mechanisms associated with their corrosive wear. Static cup testing is a commonly used method for comparing the corrosion resistance performance of two or more refractory materials. Although the static cup test conditions are not as severe as dynamic tests, this study shows that the thermal gradient present within the system during heating and cooling stages serves to generate movement of the slag leading to mechanical wear. The thermal gradient within the refractory, and between the slag and the refractory, occurs during the ramp stage of the test and lasts until the soaking stage is reached bringing the system to a thermal equilibrium. Using computational fluid dynamics (CFD) capabilities embedded within ANSYS software, this study modelled and quantified the convection currents within the slag and associated shear stresses generated on the refractory walls due to the thermal gradient. A traditional ladle furnace was employed as a case study to verify the results of the studied CFD model. The corrosion rate of the refractory lining was found to depend on the mass transfer coefficient of the refractory dissolution into the slag, and a velocity term which governs the extent of corrosion at any given location. This velocity term is a function of slag viscosity, as well as the concentration gradient and/or temperature gradient at the triple points. In this study, wall shear stress was used as a reliable proxy for identifying high-velocity regions prone to excessive corrosive wear. Elevated wall shear stress near the slag/air and slag/molten steel interfaces align with observed corrosion grooves, which reflects the intensified corrosive wear at these locations.

Ramteke, Rajat Rajat Durgesh Ramteke [University o↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Particle Size and Concentration of Magnesium Oxide on the Lubricating Performance of a Chloride Molten Salt for Concentrating Solar Power

One engineering challenge for the next-generation concentrating solar power (CSP) is to identify appropriate heat transfer and thermal energy storage media. A chloride salt mixture (20 wt % NaCl + 40 wt % MgCl 2 + 40 wt % KCl) in a molten phase is proposed as a potential fluid for carrying the heat as well as lubricating the CSP pump bearings. Due to the hygroscopic nature of MgCl 2 , the presence of magnesium oxide (MgO) particles is inevitable. In order to understand the impact of MgO particles, this study investigated the tribological behavior of the molten chloride salt mixture containing MgO of various particle sizes and concentrations. Tests were conducted at 750 °C in a dry Ar environment using a zirconia ball sliding against a Haynes 244 alloy disc lubricated by the molten salt. There was a clear trend of the increased friction coefficient and wear loss for a larger particle size and/or a higher concentration of MgO. Distinct wear mechanisms were identified for the ceramic ball and alloy disc. Results provide fundamental insights for this new research avenue of molten salt lubrication for CSP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗

Impact of electron transport models on capillary discharge plasmas

Magnetohydrodynamics (MHD) can be used to model capillary discharge waveguides in laser-wakefield accelerators. However, the predictive capability of MHD can suffer due to poor microscopic closure models. Here, we study the impact of electron heating and thermal conduction on the capillary waveguide performance as part of an effort to understand and quantify uncertainties in modeling and designing next-generation plasma accelerators. To do so, we perform two-dimensional high-resolution MHD simulations using an argon-filled capillary discharge waveguide with three different electron transport coefficients models. The models tested include (i) Davies et al., (ii) Spitzer, and (iii) Epperlein–Haines (EH). We found that the EH model overestimates the electron temperature inside the channel by over 20% while predicting a lower azimuthal magnetic field. Furthermore, the Spitzer model, often used in MHD simulations for plasma-based accelerators, predicts a significantly higher electron temperature than the other models suggest.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Separation of volatile organic contaminants from water using a direct-contact dehumidifier: An experimental study and modeling

A packed-bed, direct-contact dehumidifier (PB-DCD) has been developed to selectively condense water from a gaseous mixture of organic contaminants. In this process, hot air is humidified by mixing with wastewater vapor in a static mixer and is dehumidified by subcooled fresh water passing through the PB-DCD in a counter-current configuration. The goal of this study is to understand the relationship between various operating parameters and how they affect separation of isopropyl alcohol (IPA) from the gaseous mixture with the purpose of expanding the investigation to other contaminants in the future. The process has been successfully used to separate IPA from wastewater. Different parameters including the concentration of IPA in water, feed temperature, air-to-vapor ratio, and cooling-water-to-vapor mass ratio, as well as residence time were examined to determine their influence on contaminant separation and clean water recovery rate. The Buckingham Pi theorem was applied to reduce the number of studying variables by generating non-dimensional groups. Experiments were performed to determine the relationship between the non-dimensional parameters and model mass transfer in the system. Mass transfer coefficients for multicomponent gaseous mixture condensation in a packed-bed direct contact condenser column are calculated and a modified correlation of mass transfer is developed. The parameters of the mass transfer model are obtained from operating conditions of the PB-DCD, stream conditions and thermodynamic properties. A modified Sherwood correlation is developed to predict IPA separation from a gaseous mixture consisting of air, water, and IPA. The modified Sherwood correlation is applied to successfully predict the Sherwood number with a mean absolute error equal to 6.6 %. According to the experimental results, the maximum IPA separation achieved was 76.3 %, which corresponds to a water recovery rate of 58.7 %.

42 ENGINEERING↗

Analysis of the High-Pressure High-Temperature (HPHT) growth of single crystal diamond

A multi-scale, computational model is developed to describe the growth characteristics of single-crystal diamond in the High-Pressure, High-Temperature (HPHT) process. This model is the first to connect phase-change kinetics governing crystal growth to the continuum transport of carbon through the growth cell. Results show the importance of convective transport driven by buoyant flow in the metallic solvent, which increases the growth rate by nearly an order of magnitude over that obtained under diffusion alone. Parametric studies show how crystal growth may be kinetically-limited or transport-limited, depending on the value of the macroscopic kinetic coefficient. Estimating this kinetic coefficient from growth experiments yields a phase-change Damköhler number of unity, indicating a mixed regime where phase-change kinetics and transport are comparable and strongly coupled in this system. Mechanisms responsible for slowing growth as the crystal size increases are explained. Finally, supersaturation inhomogeneities along the facets of larger crystals are predicted, which may be relevant to solvent inclusion formation during growth.

36 MATERIALS SCIENCE↗

Ab-initio molecular dynamics study of eutectic chloride salt: MgCl2–NaCl–KCl

Ionic liquid materials are viable candidates as a heat transfer fluid (HTF) in a wide range of applications, notably within concentrated solar power (CSP) technology and molten salt reactors (MSRs). For next-generation CSP and MSR technologies that strive for higher power generation efficiency, a HTF with wide liquid phase range and energy storage capabilities is crucial. Studies have shown that eutectic chloride salts exhibit thermal stability at high temperatures, high heat storage capacity, and are less expensive than nitrate and carbonate salts. However, the experimental data needed to fully evaluate the potential of eutectic chloride salts as a HTF contender are scarce and entail large uncertainties. Considering the high cost and potential hazards associated with the experimental methods used to determine the properties of ionic liquids, molecular modeling can be used as a viable alternative resource. In this study, the eutectic ternary chloride salt MgCl 2 –NaCl–KCl is modeled using ab-initio molecular dynamics simulations (AIMDs) in the liquid phase. Using the simulated data, the thermophysical and transport properties of eutectic chloride salt can be calculated: density, viscosity, heat capacity, diffusion coefficient, and ionic conductivity. For an initial model validation, experimental pair-distribution function data were obtained from X-ray total scattering techniques and compared to the theoretical pair-distribution function. Additionally, theoretical viscosity values are compared to experimental viscosity values for a similar system. The results provide a starting foundation for a MgCl 2 –NaCl–KCl model that can be extended to predict other fundamental properties.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Automated Control for Nuclear Thermal Propulsion Start-Up using MOOSE-based Applications

This report presents a Griffin/Bison/RELAP-7 numerical model of a prototypical NTP system that features fuel assemblies arranged in rings, and which was designed to simulate rapid startup transients. The physics modeled include full-core neutronics, assembly-wise heat conduction, and conjugate heat transfer, with the balance of plant mainly imposed through boundary conditions. In addition, various forms of automated reactivity control were deployed by using the MOOSE to autonomously drive the model and simulate the reactor transitioning from assumed initial conditions to nominal power in a fraction of a minute. To generate the cross-sections of the neutronics model, and in an effort to simultaneously account for the tremendous axial temperature gradients in the reactor and to limit the number of state points required for cross-section generation, the average component temperatures and hydrogen densities in the cooling channels were correlated to the average fuel and moderator temperatures, and fixed axial profiles were derived for nominal conditions and then used during the transient. With this approximation, a tractable cross-section library tabulated with fuel/moderator temperatures and CD angles was generated using Serpent. The full-core SPH correction procedure and the CD decusping technology in Griffin, respectively, ensure preservation of the multiplication factor and reaction rates at state points, along with a reasonably accurate reactivity worth between tabulated CD angles, despite using a coarse mesh. Feedback from other physics was calculated by modeling one representative fuel assembly per ring, along with the corresponding fuel and moderator cooling channels. To limit power overshoots during startup, another layer of multiphysics coupling was added to the model in order to automatically control the drums. Two different technologies presented herein showed outstanding performance in this regard: (1) a novel hybrid PID controller based on both power and reactivity signals, and (2) a PGC that relies on kinetics parameters and reactivity coefficients to predict future behavior and adjust the desired signal accordingly. A challenging benchmark was devised, featuring a power demand curve that exponentially increases by a factor of 500 within 30 seconds, then levels out after that. Both control approaches create a simulated power curve that closely follows the power demand curve and limits power overshoots to 1% or less. While the former approach requires more tuning of the internal parameters, the latter requires additional knowledge of the reactivity feedback coefficients and rates of change of the corresponding variables, including fuel and moderator temperature, which could be difficult to dynamically measure for a real NTP system. Fortunately, some inaccuracy in these quantities will not drastically degrade the PGC performance. Subsequently, a more realistic startup sequence was considered, in which the mass flow rate and outlet pressures are ramped up to model bootstrap and thrust build-up phases prior to reaching steady-state conditions, demonstrating the ability of the hybrid PID and PGCs to handle such transients, with both types of controllers exhibiting very similar behavior. Nevertheless, a significant chamber temperature overshoot was observed, caused by the demanded power signal and assumed mass flow rate. This issue could be mitigated by deploying a reactor controller that follows the chamber temperature signal and actuates both the control valves and drums (rather than using a power signal based solely on the drums to control reactivity). Enhancement of the hydrogen fluid properties available in MOOSE, as well as a better understanding of prototypical initial conditions, are also needed to further enhance this startup model. Finally, a study was performed to model decay heat post-shutdown, and to prepare for extending this model to predict shutdown behavior and post-shutdown pulsed cooling requirements.

33 ADVANCED PROPULSION SYSTEMS↗