Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Towards Improved Decision Making for the Smarter Grid: Geomagnetic Disturbance Implicit Modeling Uncertainty Quantification

Geomagnetic disturbances can greatly disrupt the power grid operation. This is caused by low-frequency changes in the earth’s magnetic field, which upon interaction with the deep earth conductivity induces a changing electric field at the earth’s surface. This in turn induces quasi-direct currents which have the potential to cause protective devices to operate, widespread damage to high-voltage transformers, or voltage collapse due to induced reactive power losses. While these impacts have been known since the 1940s, only recently have standards for GMD response been implemented. Because these standards are heavily based on models, it is important to understand when it is appropriate to make certain modeling assumptions. In this work, implicit modeling uncertainty is quantified for the purpose of enhanced decision making for disturbance impact mitigation. Considering electromagnetic models, modeling assumptions of non-uniform grounding, imbalanced operation, transformer saturation, and geomagnetically induced currents, voltage estimation values are analyzed. Statistical characteristics of modeling uncertainty are obtained by analysis of synthetically generated data. Results statistically characterize geomagnetic disturbances modeling uncertainty, providing an important tool for impact mitigation.

grid analysis↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Measurement-Based Approach for Inertia-Trend Analysis of the US Western Interconnection

Rising deployment of inverter-based resources (IBRs), characterized by a lack of rotating mass, is decreasing the total inertia of the system. This can lead to an increased Rate of Change of Frequency (RoCoF) during the disturbance and false activation of protective devices. There is a need to assess the inertia over the past decade amidst the evolving landscape of renewable energy sources to develop strategies for integrating energy storage, enhancing resilience measures, and ensuring the stable and reliable operation of the grid. Therefore, a realistic assessment of the inertia trend using a measurement-based approach that addresses the limitations of existing models is proposed. An inertia study of the Western Interconnection in the United States is performed utilizing the data from 2013 to 2022, obtained from FNET/ GridEye network. The three-second RoCoF time window is chosen for the study as it showed an optimum balance between a strong correlation with the power imbalance (ΔP) and minimum inclusion of primary response from governor. The obtained inertia trend result shows a small percentage declination of inertia over the decade. By examining the result alongside a generation mix graph, insights are gained into the dynamic interplay between shifting energy landscape and system inertia.

Dulal, Saurav↗

Omega-Limit Sets and Input-To-State Stability in Power Grids with Switching Equilibria

This paper studies a power transmission system with both conventional generators (CGs) and distributed energy assets (DEAs) providing frequency control. We consider an operating condition with demand aggregating two dynamic components: one that switches between different values on a finite set, and one that varies smoothly over time. Such dynamic operating conditions may result from protection scheme activations, external cyber-attacks, or due to the integration of dynamic loads, such as data centers. Mathematically, the dynamics of the resulting system are captured by a system that switches between a finite number of vector fields - or modes -, with each mode having a distinct equilibrium point induced by the demand aggregation. To analyze the stability properties of the resulting switching system, we leverage tools from hybrid dynamic inclusions and the concept of ..omega.. -limit sets from sets. Specifically, we characterize a compact set that is semi-globally practically asymptotically stable under the assumption that the switching frequency and load variation rate are sufficiently slow. For arbitrarily fast variations of the load, we use a level-set argument with multiple Lyapunov functions to establish input-to-state stability of a larger set and with respect to the rate of change of the loads. The theoretical results are illustrated via numerical simulations on the IEEE 39-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Situational Awareness of Grid Anomalies (SAGA)

The modern power industry becomes more vulnerable to cyber events due to the growing interconnectivity, interdependence, and complexity of the electric power grid. High-fidelity modeling and simulation tools that support the preventative risk analysis on potential cyber-relevant events is essential for ensuring the situational awareness of the system operator as it provides an inexpensive and risk-free environment to test the system responses under various cyber-relevant events and hereby can support research on cyber anomaly detection, optimal protective resource allocation, and mitigation measures. In this webinar, we will share NREL's cybersecurity research capabilities by highlighting the development of a scalable cyber-physical event test bed and demonstration with real hardware in the loop. The developed cyber-physical event test bed is backboned by an integrated transmission, distribution, and communication dynamic co-simulation framework and a plug-and-play cyber event generation module. It is designed to be modular and compatible with parallel computing, and thereby supports large-scale system simulations at an affordable computation cost. The test bed can capture millisecond-to-minutes dynamic frequency and voltage responses under cyber events from the bulk transmission system to the active distribution systems and distributed energy resources at the grid edge.

co-simulation↗

Intel® DOE Grid Security Enhancement Security in Power System Edge. Final Technical Report

Intel® and its partners, Schneider Electric and LiveData Utilities, were tasked by Department of Energy to explore solutions in two areas of grid security. One, secure the existing communication network and the legacy devices with minimal disruption to the infrastructure, and second, to develop capabilities in semiconductor chips such that they come with built-in security to order to provide secure communication and protection from cyberattacks with minimal effort from operation technology (OT) application developers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Protection for Microgrids and DER in Secondary Networks and Meshed Distribution Systems

Although there are increasing numbers of distributed energy resources (DERs) and microgrids being deployed, current IEEE and utility standards generally strictly limit their interconnection inside secondary networks. Secondary networks are low-voltage meshed (non-radial) distribution systems that create redundancy in the path from the main grid source to each load. This redundancy provides a high level of immunity to disruptions in the distribution system, and thus extremely high reliability of electric power service. There are two main types of secondary networks, called grid and spot secondary networks, both of which are used worldwide. In the future, primary networks in distribution systems that might include looped or meshed distribution systems at the primary-voltage (medium-voltage) level may also become common as a means for improving distribution reliability and resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods, systems, and computer readable media for protecting and controlling a microgrid with a dynamic boundary

Methods, systems, and computer readable mediums for protecting and controlling a microgrid with a dynamic boundary are disclosed. One method includes detecting a fault in a microgrid that includes a dynamic point-of-common-coupling (PCC), in response to determining that the microgrid is operating in a grid-connected mode, isolating the fault by tripping a microgrid side smart switch and a grid side smart switch that are located immediately adjacent to the fault, initiating the reclosing of the grid side smart switch, and initiating the reclosing for the microgrid side smart switch via resynchronization if the grid side smart switch is successfully reclosed, and in response to determining that the microgrid is operating in an islanded mode, isolating the fault by tripping a microgrid side smart switch that is located immediately adjacent to the fault, and initiating the reclosing of the microgrid side smart switch.

Wang, Fei↗

NEFTSec: Networked federation testbed for cyber-physical security of smart grid: Architecture, applications, and evaluation

As today's power grid is evolving into a densely interconnected cyber-physical system (CPS), a high fidelity and multifaceted testbed environment is needed to perform cybersecurity experiments in a realistic grid environment. Traditional standalone CPS testbeds lack the ability to emulate complex cyber-physical interdependencies between multiple smart grid domains in a real-time environment. Therefore, there are ongoing research and development (R&D) efforts to develop an interconnected CPS testbed by sharing geographically dispersed testbed resources to perform distributed simulation while analysing simulation fidelity. This paper presents a networked federation testbed for cybersecurity evaluation of today's and emerging smart grid environments. Specifically, it presents two novel testbed architectures, including cyber federation and cyber-physical federation, identifies R&D applications, and also describes testbed building blocks with experimental case studies. It also presents a novel co-simulation interface algorithm to facilitate distributed simulation within cyber-physical federation. The resources available at the PowerCyber CPS security testbed at Iowa State University (ISU) and the US Army Research Laboratory are utilised to develop this platform for performing multiple experimental case studies pertaining to wide-area protection and control applications in power system. Finally, experimental results are presented to analyse the simulation fidelity and real-time performance of the testbed federation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the Resource Adequacy and Community Impacts of an Evolving Grid: Considerations for State Regulators

As U.S. power systems continue to decarbonize, state regulators must be able to broadly assess the cost and reliability implications of proposed fossil retirements and the corresponding resources that are coming online to replace them. Specifically, regulators must evaluate whether proposed infrastructure investments are sufficient to ensure the long-term reliability of the system, while also protecting rate payers by ensuring that such investments are necessary and not excessive. Broadly speaking, this objective is typically framed in terms of maintaining long-term resource adequacy at the lowest cost, while also ensuring that other social and/or environmental objectives are satisfied. System planners currently have a host of sophisticated analytical tools at their disposal to evaluate the cost-benefit trade-offs of different approaches to ensuring resource adequacy. However, most of these tools and associated metrics were designed with traditional power systems in mind. Over the past decade, it has become increasingly clear that the metrics and models that have reliably assessed resource adequacy in systems dominated by large thermal and hydropower resources will be insufficient for systems with significant contributions from emerging technologies such as wind, solar and storage. Therefore, in recent years many new metrics and modeling approaches have been developed, and are increasingly being implemented, to meet the needs of the clean energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

cerf: A Python package to evaluate the feasibility and costs of power plant siting for alternative futures

Long-term electric power sector planning and capacity expansion is a key area of interest to stakeholders across a wide range of organizations because it helps in making informed decisions about investments in infrastructure within the context of potential future vulnerabilities under various natural and human stressors. Future power plant siting costs will depend on a number of factors including the characteristics of the electricity capacity expansion and electricity demand (e.g., fuel mix of future electric power capacity, and the magnitude and geographic distribution of electricity demand growth) as well as the geographic location of power plants. Electricity technology capacity expansion plans modeled to represent alternate future conditions meeting a set of scenario assumptions are traditionally compared against historical trends which may not be consistent with current and future conditions. We present the `cerf` Python package (a.k.a., the Capacity Expansion Regional Feasibility model) which helps evaluate the feasibility and structure of future, scenario-driven electricity capacity expansion plans by siting power plants in areas that have been deemed the least cost option while considering dynamic future conditions. We can use `cerf` to gain insight to research topics such as: 1) under what conditions future projected electricity expansion plans from models such as GCAM-USA are possible to achieve, 2) where and which on-the-ground barriers to siting (e.g., protected areas, cooling water availability) may influence our ability to achieve certain expansions, and 3) how electricity infrastructure build-outs and value may evolve into the future when considering locational marginal pricing (LMP) based on the supply and demand of electricity from a grid operations model.

20 FOSSIL-FUELED POWER PLANTS↗

Securing Inverter Communication: Proactive Intrusion Detection and Mitigation System to Tap, Analyze, and Act

The electric grid has undergone rapid, revolutionary changes in recent years; from the addition of advanced smart technologies to the growing penetration of distributed energy resources (DERs) to increased interconnectivity and communications. However, these added communications, access interfaces, and third-party software to enable autonomous control schemes and interconnectivity also expand the attack surface of the grid. To address the gap of DER cybersecurity and secure the grid-edge to motivate a holistic, defense-in-depth approach, a proactive intrusion detection and mitigation system (PIDMS) device was developed to secure PV smart inverter communications. The PIDMS was developed as a distributed, flexible bump-in-the-wire (BITW) solution for protecting PV smart inverter communications. Both cyber (network traffic) and physical (power system measurements) are processed using network intrusion monitoring tools and custom machinelearning algorithms for deep packet analysis and cyber-physical event correlation. The PIDMS not only detects abnormal events but also deploys mitigations to limit or eliminate system impact; the PIDMS communicates with peer PIDMSs at different locations using the MQTT protocol for increased situational awareness and alerting. The details of the PIDMS methodology and prototype development are detailed in this report as well as the evaluation results within a cyber-physical emulation environment and subsequent industry feedback.

14 SOLAR ENERGY↗

Planning for Seattle at the Convergence of Resilience and Energy

Grid reliability metrics obscure important temporal, spatial, and categorical considerations for increasing energy resilience. Systemwide or feeder-level outage metrics do not identify which kinds of services are affected by outages, where, and for how long. These outage metrics indicate the impacts of outages but cannot measure the consequences to customers that could result from those outages. The consequences of power outages for surrounding community members are caused by disruptions to electricity-dependent critical services, rather than to electricity itself. Power outages can decrease a community's access to healthcare, fuel, safe indoor temperatures, and provisions like food and water. This project developed critical service access, a new consequence-focused resilience metric that quantifies the relative access to critical services provided to households by distribution infrastructure during normal conditions and major disruptions. We use a spatially granular grid analysis that facilitates targeted resilience interventions; dividing feeders into isolatable sections and combining those sections with the critical service access metric allows us to identify where energy improvements like solar-plus-storage microgrids could create the most benefits for community members by protecting access to food, fuel, health, shelter, and public safety services. We identify locations in a South Seattle study area that could be high priorities for resilience investment and summarize their potential neighborhood-scale resilience benefits. This analysis was complemented by direct feedback from study area residents collect through a survey and focus groups. Results can help utilities understand how and where long power outages can create real consequences for customers, set strategic targets based on that understanding, and measure the potential benefits of energy resilience upgrades for more informed decisions.

14 SOLAR ENERGY↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗

Bishop Paiute Single Family Solar Home Project: Phase 4 (Final Technical Report)

The Bishop Paiute Tribe is committed to energy efficiency, renewable energy, and environmental protection and has a vision to install solar energy systems on all buildings on the Reservation where technically feasible. Through completion of the Bishop Paiute Tribe Residential Solar Program – Phase 4, Bishop Paiute Tribe continued its successful model partnering with non-profit solar installer GRID Alternatives to advance its vision and build energy self-sufficiency on the Bishop Paiute Reservation. The Bishop Paiute Tribe Residential Solar Program – Phase IV deployed 67 kW-AC of new clean, renewable energy through grid-tied, net-metered rooftop solar electric systems installed on a total of 20 (one more than the planned 19) existing owner-occupied, single-family homes for low-income families on the Reservation. This represents nearly 14% of the Reservation’s total “unsolarized” homes. These systems were provided at no cost to the homeowners, who will also receive energy efficiency education to further reduce energy consumption and lower electric bills. GRID led a solar installation for three (3) of the homes where Tribal/community members, were given an opportunity in participating in on-the-roof trainings to gain new skills while installing solar for their low-income community members. Subcontractors through GRID Sub Contractor Partnership Program (GRID SPP) led solar installations for seventeen (17) of the homes. Each installation provided paid employment for a solar trainee trainees hired by the SPP subcontractors as entry level solar installers. It is estimated that the installed 67 kW-AC of solar will produce at least 120,000 kWh/year, displacing at least 30-75% of the 20 homes’ total electricity use for a combined system lifetime electricity cost savings for the low-income homeowners of about $\$$500,000. It is further estimated that the installed renewable energy systems installed will prevent greenhouse gases by about 1,000 tons, equivalent to planting approximately 25,000 trees. Following the successful completed installations, it is expected that the Reservation and surrounding communities will benefit from improved air quality via reduced wood stove use for heating. Cumulatively with other initiatives, the project will result in nearly 40% of the Reservation’s solarizable homes being solarized. Overall, the triple impact of the phase 4 of the Bishop Paiute Tribe Residential Solar Program – Phase 4 is: 1) affordable energy for low-income families; 2) on-site clean energy production, 3) hands on training and paid solar installation work for local tribal/community workers. These impacts will support and grow the Tribe’s energy, economic, environmental, and social self-sufficiency and sovereignty amongst the neediest on the Reservation.

14 SOLAR ENERGY↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗