Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

KONUS-W gamma-ray burst experiment for ISTP WIND spacecraft

The primary task of the KONUS-W experiment to be flown on board the WIND spacecraft is to observe gamma-ray bursts and solar flares with moderate and high time resolution. The scientific objectives of the experiment include the study of continuum energy spectra and spectral features of these events in the energy range of 10 keV to 10 MeV as well as their time histories in soft, medium, and hard energy bands with a time resolution up to 2 ms. The general design and operation of the KONUS-W gamma-ray detector are briefly described, and the nomial program of burst observations is examined.

Aptekar', R. L.↗

Prospects for high pressure imaging gas scintillation drift chambers

The current developmental status and future potential of a promising hard X-ray and gamma ray detector are presented: the high pressure xenon gas scintillation imaging drift chamber. A scheme for reading out the scintillation light waveshifting fibers, which allows operation at pressures at least as high as 20 atmospheres, is used. This technique combines excellent spatial resolution (approximately 200 rms allowing 1.5 arcminute mapping resolution), very good energy resolution (within a factor of three of Ge detectors), good time resolution (approximately 100 ns), and extremely high sensitivity because of excellent background rejection capabilities; it also offers possibilities for extrapolation to large area detectors. Results from tests with a prototype chamber are presented. The design of a scientific instrument for a balloon flight planned in 1995 is described. This instrument, the Scintillation Imaging Gas filled Hard X-ray Telescope (SIGHT), is optimized for detecting 30 to 300 keV X-rays. It has an active area of 1140 sq cm, with a stopping power of between 2.0 and 2.7 g/sq cm of xenon at 20 atmospheres. Possible future evolutionary tracks of the technology leading to innovative satellite applications are discussed.

Edberg, T. K.↗

Data Acquisition and Prompt Analysis System for High Altitude Balloon Experiments

An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.

Sarkady, A. A.↗

Purification and Crystal Growth of Lead Iodide by Physical Vapor Transport Method

Lead iodide (PbI2) is a layered compound semiconductor being developed as room temperature x- and gamma-ray detector. Compared to the more studied material, mercuric iodide, PbI2 has a higher melting temperature and no phase transition until liquid phase which are indications of better mechanical properties. In this study, the source material was purified by the zone-refining process, and the purest section was extracted from center of the the zone-refined ingot to be grown by physical vapor transport (PVT) method. The zone-refined material and as-grown crystals were characterized by optical microscopy and differential scanning calorimetry (DSC) to reveal the surface morphology, purity and stoichiometry. The results shows that both materials are near-stoichiometric composition, with the purity of the as-grown crystals higher than zone-refined materials. The resistivity of the as-grown crystal (10" Omega-cm) was derived from current-voltage (I-V) measurement, and is 10 times higher than the zone-refined materials. Detail results will be presented and discussed.

Wright, G. W.↗

Research Facilities

Donald E. Bohringer, Argonne engineering specialist employed NASA information in two projects associated with the laboratory's Intense Pulsed Neutron Source (IPNS) facility. The NASA technology Bohringer employed involved improved vibration protection for a gamma ray detector in one project, and in the other a new leak detection technology. IPNS and other Argonne facilities have many vacuum and pressure vessels and early detection of leaks is highly important. Bohringer learned of both items in Tech Briefs.

Source record↗

Impurity Studies of Cd(0.8)Zn(0.2)Te Crystals Using Photoluminescence and Glow Discharge Mass Spectroscopy

Cd(1-x)Zn(x)Te semiconductor crystal is a highly promising material for room temperature x- and gamma-ray detector applications because of its high resistivity, long carrier lifetime, and relatively high hole and electron mobilities. This paper reports the investigation of the impurities in several Cd(1-x)Zn(x)Te (x = 0.20) crystals grown using the vertical Bridgman method under a Cd overpressure. The impurity concentrations were measured using glow discharge mass spectroscopy (GDMS). The energy states of the impurities were studied using photoluminescence (PL) spectroscopy at liquid helium temperature. The PL spectra showed a series of sharp high energy lines which are associated with free excitons and excitons bound to impurities as donors and acceptors in the crystals. The impurities also contributed to donor-acceptor pair recombination. The correlation between the GDMS and PL results will be reported.

Su, Ching-Hua↗

High-Energy Emission From the Polar Cap and Slot Gap

Thirty-five years after the discovery of rotation-powered pulsars, we still do not understand the fundamentals of their pulsed emission at any wavelength. I will review the latest developments in understanding the high-energy emission of rotation-powered pulsars, with particular emphasis on the polar cap and slot gap models. Special and general relativistic effects play important roles in pulsar emission, from inertial frame-dragging near the stellar surface to aberration, time-of-flight and retardation of the magnetic field near the light cylinder. Understanding how these effects determine what we observe at different wavelengths is critical to unraveling the emission physics. I will discuss how the next generation of gamma-ray detectors, AGILE and GLAST, will test prediction of these models.

Harding, Alice K.↗

New Scintillator Materials (K2CeBr5) and (Cs2CeBr5)

Cesium cerium bromide (Cs2CeBr5) and potassium cerium bromide (K2CeBr5) are new scintillator materials for X-ray and gamma ray detector applications. Recently halide scintillator materials, such as Ce doped lanthanum bromide has been proved to be very important material for the same purpose. These materials are highly hygroscopic; a search for high light yield non-hygroscopic materials was highly desirable to advance the scintillator technology. In this paper, we are reporting the crystal growth of novel scintillator materials, cesium cerium bromide (Cs2CeBr5) and potassium cerium bromide (K2CeBr5). Crystals were successfully grown from the melt using the vertical Bridgman-Stockbarger technique, in a comparison with the high performance LaBr3 or LaCl3 crystals, cerium based alkali halides crystals, (Cs2CeBr5) and (K2CeBr5) have similar scintillation properties, while being much less hygroscopic. Furthermore, cesium based compounds will not suffer from the self-activity present in potassium and lanthanum compounds. However the Cs2CeBr5 crystals did not grow properly probably due to non-congruent melting or to some phase transition during cooling. Keywords." Scintillator materials; Ce3+; Energy resolution; Light yield; K2CeBr5

Hawrami, R.↗

Planetary Geochemistry Techniques: Probing In-Situ with Neutron and Gamma Rays (PING) Instrument

The Probing In situ with Neutrons and Gamma rays (PING) instrument is a promising planetary science application of the active neutron-gamma ray technology so successfully used in oil field well logging and mineral exploration on Earth. The objective of our technology development program at NASA Goddard Space Flight Center's (NASA/GSFC) Astrochemistry Laboratory is to extend the application of neutron interrogation techniques to landed in situ planetary composition measurements by using a 14 MeV Pulsed Neutron Generator (PNG) combined with neutron and gamma ray detectors, to probe the surface and subsurface of planetary bodies without the need to drill. We are thus working to bring the PING instrument to the point where it can be flown on a variety of surface lander or rover missions to the Moon, Mars, Venus, asteroids, comets and the satellites of the outer planets.

Parsons, A.↗

The Hitomi X-Ray Observatory, Part 2

When it was launched on 17 February 2016, the Hitomi X-ray Observatory carried four kinds of new-generation x-ray instruments—the Soft X-ray Spectrometer (SXS), the Soft X-ray Imager (SXI), the Hard X-ray Imager (HXI), and the Soft Gamma-ray Detector (SGD). All four instruments were turned on and were in the process of activation at the time of loss of contact on 26 March 2016. In the time it was operational, Hitomi was able to provide researchers with a trove of ground-breaking scientific results. Initial results demonstrated that the instruments were meeting or exceeding requirements and that Hitomi was on its way to pioneering a new era of broad-band and high-resolution x-ray spectroscopy. The results published here summarize the in-flight instrument performance, calibration, and data processing accomplishments of the observatory. Of the papers accepted for publication in this special section, 17 were presented in Part 1 in the January-March 2018 issue of JATIS (Journal of Astronomical Telescopes, Instruments, and Systems). Ten more papers are presented here as Part 2 in the April-June 2018 issue. These papers cover the detailed in-flight performance of the four state-of the-art instruments on-board the Hitomi X-Ray Observatory. These instruments were extremely diverse in their design and principles of operation, ranging from low temperature x-ray calorimeters for high-resolution spectroscopy, CCDs (Charge-Coupled Devices) for wide field imaging, high fill-factor grazing incidence x-ray optics, including multilayer x-ray optics and silicon strip and CdTe strip detectors for high-energy imaging, and a Si/CdTe Compton cameras for extending the bandpass out to 600 kiloelectronvolts. All of these instruments operated as expected and for sufficient time to validate their operating principles and carry out first light scientific investigations, published elsewhere. Collectively, these instruments, all co-aligned and operated simultaneously, provided a tool for astronomers with unprecedented resolution and broadband sensitivity for investigating high-energy processes throughout the universe. These papers serve as part of the Hitomi legacy and will guide the next generation of instruments planned for future missions.

Kelley, Richard L.↗

Airborne Lightning Observatory for FEGS and TGFs (ALOFT)

The ALOFT campaign is a unique suborbital campaign to advance the science of highenergy radiation emissions from thunderstorms, validate existing spaceborne lightning mappers and evaluate design concepts for next-generation mappers, and study convection from a suborbital platform. ALOFT is a collaboration between NASA, the University of Bergen, and other institutions that will fly the ER-2 aircraft over tropical thunderstorms around the Gulf of Mexico, Central America, and the Caribbean. The payload will consist of lightning detectors, gamma-ray scintillators, and a mixture of passive and/or active microwave sensors. Supporting the flights will be a diverse groundbased network of lightning instruments spread across the region of interest.

Nikolai Ostgaard↗

Method and apparatus to obtain limited angle tomographic images from stationary gamma cameras

A nuclear imaging system and method for performing three-dimensional imaging of anatomical structures. The system and method includes two or more gamma ray detectors each used in combination with a variable-slant hole collimator. The detectors are positioned in close proximity to, or in contact with, the structure being imaged. The detectors remain in a stationary position during the data collection process. An imaging or reconstruction method is then used to reconstruct a three-dimensional image from the data derived from the detectors.

Kross, Brian J.↗

Triple-mode detector for fast neutrons, slow neutrons, and gamma ray spectroscopy

This disclosure provides systems, methods, and apparatus related to neutron detection and gamma ray detection. In one aspect, a detector comprises a scintillator structure that comprises an organic scintillator and an inorganic scintillator. The organic scintillator is in the form of one or more elements of a specified length. The inorganic scintillator is in the form of one or more elements of the specified length. First ends of the one or more organic scintillator elements and first ends of the one or more inorganic scintillator elements define a first surface. Second ends of the one or more organic scintillator elements and second ends of the one or more inorganic scintillator elements define a second surface.

Derenzo, Stephen↗

Gamma ray spectroscopy in astrophysics: Future role of scintillation detectors

The future role of conventional scintillation detector telescopes for line gamma-ray astronomy is discussed. Although the energy resolution of the germanium detectors now being used by several groups is clearly desirable, the larger effective areas and higher efficiencies available with scintillation detectors is advantageous for many observations. This is particularly true for those observations of astrophysical phenomena where significant line broadening is expected.

Kurfess, J. D.↗

New room temperature high resolution solid-state detector (CdZnTe) for hard x rays and gamma rays

The new CdZnTe high 'Z' material represents a significant improvement in detectors for high energy photons. With the thicknesses available, photons up to 100 keV can be efficiently detected. This material has a wide band gap of 1.5 - 2.2 eV which allows it to operate at room temperature while providing high spectral resolution. Results of resolution evaluations are presented. This detector can be used for high resolution spectral measurements of photons in x-ray and gamma-ray astronomy, offering a significant reduction in the weight, power, and volume of the detector system compared to more conventional detector types such as scintillation counters. In addition, the detector will have the simplicity and reliability of solid-state construction. The CdZnTe detector, as a new development, has not yet been evaluated in space. The Get Away Special program can provide this opportunity.

Stewart, Amyelizabeth C.↗