Tri-state logic computation by activating DNA origami chains
A rod-like DNA origami circuit platform, featuring sticky ends near each semi-flexible hinge can operate two-state and tri-state logic gate by using configuration change as output signals.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A rod-like DNA origami circuit platform, featuring sticky ends near each semi-flexible hinge can operate two-state and tri-state logic gate by using configuration change as output signals.
Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.
Energy storage plays a pivotal role in enabling power system operation with more flexibility and resilience. Unlike current practice that considers energy storages as attached ancillary devices, this paper focuses on storages as a core infrastructure by looking at their spatial distribution in the system. A sensitivity analysis based on production cost modeling is conducted to demonstrate the benefits of distributed energy storages. First, the modeling of energy storages in production cost modeling is presented. Second, potential optimal locations of distributed energy storages in a power system are discussed. Finally, multiple scenarios with various numbers and locations of additional distributed energy storages in the WECC 2030 model are created. The production cost modeling results of these scenarios show that distributed energy storages have higher utilization compared to the centralized ES units and therefore provide significantly more benefits in terms of reduction in generation cost, emission cost, and volatility of location marginal prices. A saturation effect is observed suggesting the selection of optimal locations will further improve the benefits.
To empower flexible and scalable operations, distributed control of multi-inverter microgrids, based on classical communication networks among distributed energy resources, has attracted considerable attention as it can guarantee synchronization and provide suitable remedies to the problem of improper power sharing. Notwithstanding this, resilience of the current schemes on classical communication makes microgrids vulnerable to cyber attacks. Inspired by recent revolutionary breakthroughs in quantum communication, in this paper, we devise a novel synchronization mechanism. We extend the synchronization framework utilized in distributed control algorithms to networks of quantum systems by generating pinning terms and coupling mechanism for the new synchronization rule via exploiting proper quantum jump operators and observables, and show that the quantum system will converge to a time-variant target state. Our devised quantum distributed controller (QDC) gives rise to a novel quantum communication scheme for distributed control of microgrids and enables microgrids to exploit the state-of-the-art quantum communication frameworks as communication infrastructure. Finally, test results on two representative AC and DC networked microgrids validate the efficacy and universality of the quantum distributed control.
Atomtronics deals with matter-wave circuits of ultracold atoms manipulated through magnetic or laser-generated guides with different shapes and intensities. In this way, new types of quantum networks can be constructed in which coherent fluids are controlled with the know-how developed in the atomic and molecular physics community. In particular, quantum devices with enhanced precision, control, and flexibility of their operating conditions can be accessed. Concomitantly, new quantum simulators and emulators harnessing on the coherent current flows can also be developed. Here, the authors survey the landscape of atomtronics-enabled quantum technology and draw a roadmap for the field in the near future. The authors review some of the latest progress achieved in matter-wave circuits' design and atom-chips. Atomtronic networks are deployed as promising platforms for probing many-body physics with a new angle and a new twist. The latter can be done at the level of both equilibrium and nonequilibrium situations. Numerous relevant problems in mesoscopic physics, such as persistent currents and quantum transport in circuits of fermionic or bosonic atoms, are studied through a new lens. The authors summarize some of the atomtronics quantum devices and sensors. Finally, the authors discuss alkali-earth and Rydberg atoms as potential platforms for the realization of atomtronic circuits with special features.
Many recipes for realizing topological superconductivity rely on broken time-reversal symmetry, which is often attained by applying a substantial external magnetic field. Alternatively, using magnetic materials can offer advantages through low-field operation and design flexibility on the nanoscale. Mechanisms for lifting spin degeneracy include exchange coupling, spin-dependent scattering, spin injection – all requiring direct contact between the bulk or induced superconductor and a magnetic material. Here, we implement locally broken time-reversal symmetry through dipolar coupling from nearby micromagnets to superconductor-semiconductor hybrid nanowire devices. Josephson supercurrent is hysteretic due to micromagnets switching. At or around zero external magnetic field, we observe an extended presence of Andreev bound states near zero voltage bias. We also show a zero-bias peak plateau of a non-quantized value. Our findings largely reproduce earlier results where similar effects were presented in the context of topological superconductivity in a homogeneous wire, and attributed to more exotic time-reversal breaking mechanisms [Nat. Phys. 17, 43 (2020)]. In contrast, our stray field profiles are not designed to create Majorana modes, and our data are compatible with a straightforward interpretation in terms of trivial states in quantum dots. At the same time, the use of micromagnets in hybrid superconductor-semiconductor devices shows promise for future experiments on topological superconductivity.
Connected Communities (CCs) are collections of buildings and distributed energy resources (DERs) that incorporate integrated energy management strategies at the multi-building scale. Based on the research conducted for this report, RMI and NREL have identified examples of CCs that are enabling increasingly integrated solutions, sharing resources among buildings, and providing services back to the grid. As demonstrated by these examples, CCs can provide real and scalable solutions to mitigate energy costs, enable more flexibility in grid operations, and offer choices in meeting greenhouse gas (GHG) emissions goals. Nationwide examples of these solutions are included in the appendix of this report. In order to understand the most promising practices for the design, operation, and business models associated with CCs, a search was performed to create a nationwide inventory of CCs and multiple stakeholder interviews were conducted. Based on that research, this paper explores the many factors that influence the development and operation of CCs and evaluates their potential value.
Many manufacturing industries require substantial capital and utilize energy intensive processes that involve complex phenomena. One example of such an industry is the steel industry, which is the fourth largest energy consuming industry in the U.S. By harnessing the power of High-Performance Computing (HPC) to enhance current simulation and visualization methods in the steel industry, it should be possible to increase resolution and/or decrease time of these methods by a factor of 1000. In this way, information can be obtained in a time frame that is useful for making business and engineering decisions, optimizing manufacturing processes and, ultimately, improving the completeness of U.S. industries. For example, if coke usage in blast furnaces were optimized such that the average coke rate was reduced from 797 lb/net tonne of hot metal (NTHM) to 604 lb/NTHM, costs could be reduced by $894 million/year. Additionally, members of the steel industry need the flexibility to efficiently operate blast furnaces at a range of production rates in order to meet fluctuating market demands. Large scale parameter studies can be utilized to discover workable operating parameters at a range of production rates.
Solid oxide cell-based electrolysis (SOEC) systems are being considered for hydrogen production due to their potential for high efficiencies and for their integrability with base load power generation systems when operated in solid oxide fuel cell (SOFC) mode. However, a cost prohibitive combination of SOFC power systems and SOEC systems may be required to operate the plant flexibly to produce a combination of H 2 and power on-demand. A single (consequently less expensive) reversible SOFC/SOEC system, on the other hand, poses technological challenges related to the on demand switching between power and H 2 production. This report provides a high-level technical assessment of a novel SOFC based H 2 production concept that averts the potential drawbacks of the SOEC systems. The novel concept combines the advantages of steam-reforming of natural gas to produce H 2 with the high efficiency power generation capabilities of a SOFC in a single package.
Commercial oxygen generation technologies deploy either cryogenic air separation or vacuum pressure swing adsorption (VPSA). These technologies can provide nearly pure oxygen but are only economically viable at oxygen production rates of 100-7,000 tonnes/day. The state-of-theart cryogenic air separation plants are impending the theoretical limits of thermodynamic efficiency but cannot be scaled down to cater future needs. Therefore, there is great incentive to develop a new approach for oxygen separation that can accommodate the upcoming demands. Our proposed research approach address to find novel methodologies to provide energy efficient modular O 2 on demand systems for modular gasification and other applications. Small scale modular systems for O 2 production offer certain benefits including enhanced energy efficiency, reduced operating costs and flexibility to tailor location specific needs. Our hypothesis is that a small modular system could be engineered using solvent-based capture and thermal release of oxygen, to enable “oxygen on demand” for any combustion-related technology.
This energy services interface (ESI) requirements document represents a process step in the path for creating an ESI specification, which will describe the technical characteristics of an ESI. This document outlines the concepts that need to be covered in the ESI specification, such as principal functions of the ESI, grid services communicated through the ESI, and the ESI lifecycle. It provides context for the Department of Energy’s (DOE’s) Grid Modernization Laboratory Consortium (GMLC) to engage industry participants in the development of the ESI specification. To do this, it describes the desired contents of the ESI specification and provides examples of the type of material that needs to be included in it. The purpose of the ESI specification is to define the requirements that are to be addressed in information and communications technology (ICT) interface standards for enabling the integration of a facility containing responsive distributed energy resources (DER facility) to an electric system consistent with the fundamental ESI principles. In this context, a DER facility may consist of a single DER with a communicating controller or may be as complex as a microgrid campus with several buildings and many DERs. The ESI specification is not a technical interface standard, but the requirements in the specification can be used to check that existing, augmented, or new interface standards meet the interoperability requirements of the ESI concept, which is explained further in this document. In this way, the ESI specification can be used to guide standards advancement work in multiple standards development organizations. To explain the scope of the ESI specification, this ESI requirements document provides examples of situations (or illustrative applications) for using an ESI to coordinate DER flexibility for grid operations. These examples originate from foundational work for describing common grid-DER service agreements that are anticipated to be supported using this interface.
Improving the understanding of how computational fluid dynamics (CFD) direct numerical simulations (DNS) of flows in the High Flux Isotope Reactor (HFIR) perform when run in parallel using the high performance computing (HPC) platform Summit at the Oak Ridge Leadership Computing Facility (OLCF) is of particular importance to boost the computational tools used to support HFIR conversion to low enriched fuel (LEU). Evaluation of scaling performance was driven by the increasing importance of graphics processing unit (GPU) usage in HPC, which is becoming the standard for modern supercomputers such as Summit. The desired results are to obtain a strong positive correlation between the computational resources dedicated to a problem and the relative speed-up of the simulation in comparison to a benchmark. This capability will allow substantially improvement in HFIR flow analytical capabilities, specifically when predicting turbulence properties at high Reynolds numbers. The study leverages previous simulation results performed with code PHASTA (finite element) on HPC platforms Cori (NERSC) and Theta (ALCF) [1] with computing options provided in the computing platform OpenFOAM (finite volume) at OLCF. Transitioning from PHASTA to OpenFOAM will (1) eliminate dependence on third-party software for mesh generation and manipulation, (2) reduce resource needs by employing modern architectures, and (3) build expertise for future modeling of HFIR-specific problems like heat transfer in involute geometry, entrance effects, flow structure in channel corners, and so on—all important issues when defining the available thermal margins in the transition to LEU. CPUs and GPUs differ significantly in their architecture and utilization, as discussed in the literature [2]. The most important differences are in the approach to computations and their memory. A single GPU contains a large quantity of cores, enabling it to perform with a much higher throughput than a CPU, but execution requires a different approach. GPU codes execute instructions using the Single-Instruction Multiple-Thread (SIMT) approach in which a single instruction is used for groups of threads called warps. A warp typically consists of 32 threads which must execute the same set of instructions, although on separate threads. Alternately, a CPU has far fewer cores that are much more flexible in their operation, excelling at quickly performing more complex serial computations. This is why GPUs have greater throughput when properly utilized. The second important difference is seen when comparing their memory spaces. Limited memory allocations and CPU–GPU communications cause a significant bottleneck in GPU-accelerated programs. Further study was required to properly take advantage of GPU resources. A comprehensive analysis of code performance and the model-specific features of turbulence constitutes the core of this work. In this study, a DNS simulation of HFIR channel turbulence was performed with the finite volume CFD code OpenFOAM v2112 and CUDA v11.0 on Red Hat Enterprise Linux v8.2. The OpenFOAM installation had AMGx integrated to enable GPU acceleration and utilizes the PETSc4FOAM library. The computational resources and the problem size were scaled on CPU and CPU + GPU architectures to gain a better understanding of the performance of a DNS problem on modern computing hardware. The study aimed to analyze the scaling of the code exclusively on CPUs and then to examine the scaling of the codes with GPU acceleration enabled. Scaling studies included CPU and GPU acceleration on a mesh of varying resolution to analyze the impact of problem size relative to computational resources. In the course of preparing the GPU configuration on Summit, mainly using the AMGX solvers, difficulties were encountered stemming from constant changes resulting from extensive ongoing development activities and the changing environment. This resulted in the inability to complete the GPU portion of the work. The code was compiled and tested, but production runs to assess acceleration were not performed because the used discretional compute time allocation expired as year-end approached. The Summit HPC platform is scheduled for decommissioning in 2024, making it unattractive for future use with Nvidia-based GPUs. Therefore, the work will be moved onto NERSC machines in FY24. An application was prepared and submitted, and sufficient node-hours were awarded to continue the research in the next calendar year. This report summarizes work performed thus far, which mostly focused on CPU OpenFOAM computing.
The goal of this project is to build upon the work performed under the Texas Tech IDEAS project (DE-AR0000964 monitored by Dr. Isik Kizilyalli) to bring the developed B-10 enriched hexagonal boron nitride (h- 10 BN or 10 BN or BN) semiconductor neutron detector technology to the next level of maturity. In comparison to He-3 ( 3 He) gas detectors, BN neutron detectors possess all the intrinsic advantages of semiconductor devices: light weight, compact size, fast response speed, high spatial resolution, high temperature and low voltage operation capability, ease of mass production via existing semiconductor infrastructures, low cost of operation and maintenance, flexible form factors, and durability. The project will develop a prototype h- 10 BN neutron detector as a potential replacement for the 3 He gas neutron detectors (LND 25185 or equivalent) used in various neutron survey meters currently produced and commercialized by Ludlum Measurements, Inc. (LMI). To increase the overall detection efficiency, it is essential to maximize the collection efficiency of charge carriers (electrons and holes) generated by the nuclear reaction, which demands a further push to achieve 10 BN epilayers with improved material quality. The material growth processes will be guided by characterization of structural, optical, and electrical properties of h-BN. Selective devices will be calibrated at LMI. During ARPA-E supporting period, the key material parameters of h-BN produced by metal organic chemical vapor deposition (MOCVD), including the layer thickness, mobility-lifetime product, surface recombination field and detector size for maintaining a high charge collection efficiency all have been improved by several orders of magnitude. These improvements have enabled the realization of high-performance h 10BN semiconductor thermal neutron detectors. Presently, h- 10 BN thermal neutron detectors developed under ARPA-E’s support hold the record high detection efficiency among all solid-state detectors at 59%. With further development in manufacturing, there is no question that h-BN detectors will replace the traditional He-3 gas detectors in certain application areas by offering obvious advantages of semiconductor technologies over gas detectors and opportunities for users to dedicate the scarce and expensive supply of He-3 gas to other application areas where substitutes of He-3 gas are not possible.
Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.
Residential buildings with the ability to monitor and control their net-load (sum of load and generation) can provide valuable flexibility to power grid operators. We present a novel multiclass nonintrusive load monitoring (NILM) approach that enables effective net-load monitoring capabilities at high-frequency with minimal additional equipment and cost. The proposed machine learning based solution provides accurate multiclass state predictions while operating at a faster timescale (able to provide a prediction for each 60- Hz ac cycle used in US power grid) without relying on event-detection techniques. We also introduce an innovative hybrid classification-regression method that allows for the prediction of not only load on/off states but also individual load operating power levels. A test bed with eight residential appliances is used for validating the NILM approach. Results show that the overall method has high accuracy, good scaling and generalization properties.
Grid-interactive efficient buildings (GEBs) are those characterized by the combination of energy efficiency and demand flexibility with smart technologies and communications to not only deliver greater affordability and comfort to buildings, but also help utilities manage grid operations and lower system costs. This paper presents an innovative techno-economic assessment framework to effectively examine different GEB design options, explore various use cases, define technically achievable benefits, and thereby assist in informed decision-making. In particular, building load flexibility, thermal storage, and battery energy storage are considered. Advanced optimal dispatch problem is formulated to maximize the stacked value streams from multiple, competing use cases, subject to the physical capabilities and operational flexibility associated with different designs and configurations. Comprehensive case studies were performed for a real-world building to evaluate the cost-effectiveness of different GEB designs and offer in-depth insights. It was found that the proposed assessment method could effectively capture the costs and benefits linked to each GEB design option. Furthermore, the study revealed that outage mitigation and demand response are the two most significant sources of benefits for GEBs.
Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.
This paper proposes a novel Soft-Actor-Critic (SAC) based Deep Reinforcement Learning (DRL) method for optimizing the cost of microgrid operation by leveraging load flexibility. The proposed SAC-DRL method is designed to coordinate the control of distributed energy resources (DERs) and flexible load, addressing practical energy billing formation by power distribution utilities. Key contributions include an innovative reward function to mitigate sparse reward challenges and a mixed control strategy for discrete and continuous variables, ensuring radial network topology and minimizing power loss. We evaluate the proposed method on the model of a real microgrid located in Southern California, U.S.. The SAC-DRL model is tested to demonstrate its efficacy in reducing grid dependence, optimizing resource use, and minimizing costs. The results highlight the potential of DRL in modern energy systems, offering a sustainable and economically efficient solution for energy management in microgrids.