Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Field-Aging Test Bed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.

14 SOLAR ENERGY↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

LETID in Legacy and Modern PV Modules: Accelerated Testing and Field Deployment

The kinetics of light- and elevated temperature-induced degradation (LETID) in silicon solar cells depend on the precise operating excess carrier density (?n) of the device. This dependency causes differences in the way LETID manifests in modern, higher-efficiency devices compared to lower-efficiency, legacy devices that might have been deployed in the field in previous years. In this work we model how different vintages of devices are expected to behave in both accelerated laboratory testing, as well as field deployment. The differing excess carrier densities encountered in various module vintages has implications both for interpreting accelerated test data, as well as identifying, diagnosing, and potentially treating LETID in the field.

excess carrier density↗

Near-field antenna testing using the Hewlett Packard 8510 automated network analyzer

Near-field antenna measurements were made using a Hewlett-Packard 8510 automated network analyzer. This system features measurement sensitivity better than -90 dBm, at measurement speeds of one data point per millisecond in the fast data acquisition mode. The system was configured using external, even harmonic mixers and a fiber optic distributed local oscillator signal. Additionally, the time domain capability of the HP8510, made it possible to generate far-field diagnostic results immediately after data acquisition without the use of an external computer.

Kunath, Richard R.↗

Direct Air Capture Using Novel Structured Adsorbents (DE-FE0031959 Final Technical Report)

The objective of this project was to advance direct air capture (DAC) technology through a novel combination of a vacuum-temperature swing CO 2 adsorption process and structured adsorbent beds (SABs). The technical approach was to construct and operate an Integrated DAC System (IDS) at a test facility in Orange County, California. A 30 kilogram per day (kg/day) integrated field test unit was deployed into the field for testing, producing a concentrated CO 2 stream of at least 95% purity. A novel combination of DAC process and hardware with a transformational structured adsorbent laminate filter was fielded and tested at this site. The field testing also captured operational data on the novel process and material combination under real conditions. Data from this were used to advise techno-economic and life cycle analyses (TEA/LCA) of the technology. Despite the early development status and IDS aiming at field validation at TRL 5 rather than commercial scale operations, these analyses give valuable indications of this new technology route’s potential for cost reductions in DAC-based carbon dioxide removal. Climeworks and Svante are committed to further development of the technology route, including the realization of existing further cost reduction potential.

54 ENVIRONMENTAL SCIENCES↗

Sensorimotor Predictors: Examining the Relationship Between Measures of Post-Landing Sensorimotor Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to Earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on sensorimotor functional tasks. To date, we have recruited fifteen astronauts who returned from the International Space Station on Soyuz and participated in sensorimotor field tests and/or posturography within one day following long-duration spaceflight. We are specifically utilizing a combination of three quantitative post-flight functional task outcomes(relative to pre-flight baselines): tandem walk, recovery from fall and dynamic posturography, along with a subjective self-rating of post-flight decrements and recovery. The recovery from fall is performed with eyes open on a stable support, allowing the use of vestibular, visual and proprioceptive feedback for task performance. In contrast, the dynamic posturography measures are performed with eyes closed on asway-referenced unstable support, requiring reliance on vestibular feedback for task performance. Tandem walk is performed on a stable surface with eyes open and eyes closed. Fourteen of the 15 subjects performed the field tests. These were nominally performed during three timepoints on the first postflight day, while posturography was performed only once during the third time point after direct return to JSC. More than 20% were unable to complete the initial field testing in the medical tent, while all participants completed testing during the third time point at JSC. As expected, there was considerable variability among all performance outcome measures, with more variability post-flight relative to preflight. Given the variability in all post-flight outcomes, we have been examining the relationships in performance across tasks. While there is a strong association within tests obtained at different landing daytime points, our preliminary findings suggest that by R+24 hrs performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. This underscores the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that further examining specific behavioral, neuroimaging and genetic sensorimotor biomarkers with post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

S J Wood↗

Sensorimotor Predictors: Examining the Relationship Between Measures of Post-Landing Sensorimotor Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to Earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on sensorimotor functional tasks. To date, we have recruited fifteen astronauts who returned from the International Space Station on Soyuz and participated in sensorimotor field tests and/or posturography within one day following long-duration spaceflight. We are specifically utilizing a combination of three quantitative post-flight functional task outcomes(relative to pre-flight baselines): tandem walk, recovery from fall and dynamic posturography, along with a subjective self-rating of post-flight decrements and recovery. The recovery from fall is performed with eyes open on a stable support, allowing the use of vestibular, visual and proprioceptive feedback for task performance. In contrast, the dynamic posturography measures are performed with eyes closed on asway-referenced unstable support, requiring reliance on vestibular feedback for task performance. Tandem walk is performed on a stable surface with eyes open and eyes closed. Fourteen of the 15 subjects performed the field tests. These were nominally performed during three timepoints on the first post flight day, while posturography was performed only once during the third time point after direct return to JSC. More than 20% were unable to complete the initial field testing in the medical tent, while all participants completed testing during the third time point at JSC. As expected, there was considerable variability among all performance outcome measures, with more variability post-flight relative to preflight. Given the variability in all post-flight outcomes, we have been examining the relationships in performance across tasks. While there is a strong association with in tests obtained at different landing daytime points, our preliminary findings suggest that by R+24 hrs performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. This underscores the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that further examining specific behavioral, neuroimaging and genetic sensorimotor biomarkers with post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

Yiri De Dios↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Development of large wind energy power generation system

The background and development of an experimental 100 kW wind-energy generation system are described, and the results of current field tests are presented. The experimental wind turbine is a two-bladed down-wind horizontal axis propeller type with a 29.4 m diameter rotor and a tower 28 m in height. The plant was completed in March, 1983, and has been undergoing trouble-free tests since then. The present program calls for field tests during two years from fiscal 1983 to 1984. The development of technologies relating to the linkage and operation of wind-energy power generation system networks is planned along with the acquisition of basic data for the development of a large-scale wind energy power generation system.

Source record↗

Large-Eddy Simulations and Lidar Measurements of Vortex-Pair Breakup in Aircraft Wakes

Results of large-eddy simulations of an aircraft wake are compared with results from ground-based lidar measurements made at NASA Langley Research Center during the Subsonic Assessment Near-Field Interaction Flight Experiment field tests. Brief reviews of the design of the field test for obtaining the evolution of wake dispersion behind a Boeing 737 and of the model developed for simulating such wakes are given. Both the measurements and the simulations concentrate on the period from a few seconds to a few minutes after the wake is generated, during which the essentially two-dimensional vortex pair is broken up into a variety of three-dimensional eddies. The model and experiment show similar distinctive breakup eddies induced by the mutual interactions of the vortices, after perturbation by the atmospheric motions.

Lewellen, D. C.↗

Investigations of a bearing fault detector for railroad bearings

The laboratory tests are described which were conducted on new and damaged bearings to determine the feasibility of using high-frequency vibration as a diagnostic tool. A high-frequency band pass filter and demodulator was assembled to permit field measurements of the high-frequency vibrations. Field tests were conducted on an actual truck and on an axle assembly run in a grease test rig. These field tests were directed toward demonstration of the suitability and capabilities of the high-frequency technique for field application. Two specific areas of field application were identified as being cost effective for railroad use. One area is the examination of railroad roller bearings at a derailment site, and the second is as a wayside detector to supplement present hot box detectors for defective roller bearings.

Wilson, D. S.↗

Highly Permeable Rubbery Thin Film Composite Membranes for CO2 Capture from Steel Mills

This presentation will report the rational design and fabrication of NETL’s highly permeable non-aging thin film composite (TFC) membranes for CO2 capture from various industrial point sources. This talk will also cover the design, computational fluid dynamic simulation, 3D printing, and permeation testing of plate-and-frame membrane modules for an upcoming field demonstration at U. S. Steel’s Edgar Thomson Plant in Braddock, PA. The field test will demonstrate membrane-based CO2 capture from a blast furnace for decarbonization of steel manufacturing for the first time in the U.S. A mobile gas permeation test unit is currently under design and construction for the field test, which is scheduled to take place in 2025.

Zhu, Lingxiang↗

Results of the long range position-determining system tests

The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

Rhode, F. W.↗

Model predictive control for demand flexibility: Real-world operation of a commercial building with photovoltaic and battery systems

Hundreds of studies have investigated Model Predictive Control (MPC) for the optimal operation of building energy systems in the past two decades. However, MPC field tests are still uncommon, especially for small- and medium-sized commercial buildings and for buildings integrated with onsite renewables. This paper describes the implementation and the long-term performance evaluation of an MPC controller in a small commercial building equipped with behind-the-meter photovoltaics and electrochemical batteries. MPC controls space conditioning, commercial refrigeration, and the battery system. We tested two types of demand flexibility applications in the field: electricity bill minimization under time-of-use tariffs and responses to grid flexibility events. Results show that the proposed controller achieves 12% of annual electricity cost savings and 34% peak demand reduction against the baseline, while respecting thermal comfort and food safety. The field tests also demonstrate the ability of the MPC controller to provide a multitude of grid services including real-time pricing, demand limiting, load shedding, load shifting, and load tracking, using the same optimization framework.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Suited for Space

This viewgraph presentation describes the basic functions of space suits for EVA astronauts. Space suits are also described from the past, present and future space missions. The contents include: 1) Why Do You Need A Space Suit?; 2) Generic EVA System Requirements; 3) Apollo Lunar Surface Cycling Certification; 4) EVA Operating Cycles for Mars Surface Missions; 5) Mars Surface EVA Mission Cycle Requirements; 6) Robustness Durability Requirements Comparison; 7) Carry-Weight Capabilities; 8) EVA System Challenges (Mars); 9) Human Planetary Surface Exploration Experience; 10) NASA Johnson Space Center Planetary Analog Activities; 11) Why Perform Remote Field Tests; and 12) Other Reasons Why We Perform Remote Field Tests.

Kosmo, Joseph J.↗

Information Displays and Crew Configurations for UTM Operations

In this paper we discuss how team configuration may influence how infor-mation is shared among team members for low-altitude Unmanned Aircraft Systems (UAS) operations. NASA collected and analyzed observation data gathered during a series of field tests for the UAS Traffic Management (UTM) project. The field tests were part of a larger effort aimed at advancing the UTM concept, conducted at six test-sites spread across the USA. Ground control station (GCS) concepts, flight-crew composition, and crew-size var-ied within and across test-sites. Flight crews took two strategic approaches to organizing their teams. The first of the two approaches was implemented by one third of the flight crews. These crews integrated the role of UTM opera-tor into the duties of existing crew members, merging the current roles with this new one, keeping the UTM Operator collocated with the flight crew. The remaining two thirds implemented a distributed team configuration, where a single UTM operator distributed support across multiple crews. Results from our data collection efforts revealed that UTM Operator location influenced whether flight crews used verbal communication versus displays to acquire UTM information.

teams↗

Preliminary Results of Field Emission Cathode Tests

Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

Sovey, James S.↗