Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault isolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Space Launch Systems Block 1B Preliminary Navigation System Design

NASA is currently building the Space Launch Systems (SLS) Block 1 launch vehicle for the Exploration Mission 1 (EM-1) test flight. In parallel, NASA is also designing the Block 1B launch vehicle. The Block 1B vehicle is an evolution of the Block 1 vehicle and extends the capability of the NASA launch vehicle. This evolution replaces the Interim Cryogenic Propulsive Stage (ICPS) with the Exploration Upper Stage (EUS). As the vehicle evolves to provide greater lift capability, increased robustness for manned missions, and the capability to execute more demanding missions so must the SLS Integrated Navigation System evolved to support those missions. This paper describes the preliminary navigation systems design for the SLS Block 1B vehicle. The evolution of the navigation hard-ware and algorithms from an inertial-only navigation system for Block 1 ascent flight to a tightly coupled GPS-aided inertial navigation system for Block 1B is described. The Block 1 GN&C system has been designed to meet a LEO insertion target with a specified accuracy. The Block 1B vehicle navigation system is de-signed to support the Block 1 LEO target accuracy as well as trans-lunar or trans-planetary injection accuracy. Additionally, the Block 1B vehicle is designed to support human exploration and thus is designed to minimize the probability of Loss of Crew (LOC) through high-quality inertial instruments and robust algorithm design, including Fault Detection, Isolation, and Recovery (FDIR) logic.

Oliver, T. Emerson↗

Columbus IFHX Ammonia Leak Analysis

After the Columbus Moderate Temperature Loop (MTL) InterFace Heat eXchanger (IFHX) low temperature event of GMT 345-2013, NASA investigated relevant transient scenarios involving IFHX rupture after water freezing and subsequent thawing. NASA recommended development of a Fault Detection Isolation and Recovery (FDIR) plan that would, in the event of a heat exchanger freeze event, close the Water On/Off Valves (WOOVs) to isolate the heat exchanger and prevent ammonia from the external flow loops from spreading into the cabin. NASA performed a preliminary simplified analysis for the reference case of IFHX rupture, but for a deeper understanding TAS developed detailed SINDA-FLUINT models of the Columbus ITCS that were built and run through the SINAPS GUI. This allowed simulation of the ammonia leakage physics including the variation of environmental parameters, thus providing more accurate and specific input to the FDIR under development. The result was finalization of the IFHX WOOVs closure sequence and wait times to contain the ammonia propagation to Columbus and allow identification of the leaking IFHX. In addition, the analysis results provided reference pressure profiles to be used on console and by the Engineering as support for the telemetry data assessment in case of failure.This paper gives an overview on the issue and focuses on the analytical aspects of the multiphase fluid dynamics involved.

Tilloca, A.↗

System Health Management for a Series/Parallel Partial Hybrid Powertrain with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple interacting subsystems, making them much more complex than traditional aircraft propulsion systems in terms of integration and control. Electrification enables aircraft to have distributed thrust-producing fans that the flight control system can leverage for enhanced maneuverability, further increasing the control complexity. A NASA concept aircraft, the SUbsonic Single Aft eNgine (SUSAN) Electrofan, is such a vehicle. SUSAN is a series/parallel partial hybrid-electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed and implemented. This paper describes the development of some of these algorithms for system health management applied to the powertrain of the SUSAN concept aircraft.

Electrified Aircraft Propulsion↗

System Health Management for a Series/Parallel Partial Hybrid Powertrain with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple interacting subsystems, making them much more complex than traditional aircraft propulsion systems in terms of integration and control. Electrification enables aircraft to have distributed thrust-producing fans that the flight control system can leverage for enhanced maneuverability, further increasing the control complexity. A NASA concept aircraft, the SUbsonic Single Aft eNgine (SUSAN) Electrofan, is such a vehicle. SUSAN is a series/parallel partial hybrid-electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed and implemented. This paper describes the development of some of these algorithms for system health management applied to the powertrain of the SUSAN concept aircraft.

Electrified Aircraft Propulsion↗

System Health Management for a Series/Parallel Partial Hybrid Powertrain with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple interacting subsystems, making them much more complex than traditional aircraft propulsion systems in terms of integration and control. Electrification enables aircraft to have distributed thrust-producing fans that the flight control system can leverage for enhanced maneuverability, further increasing the control complexity. A NASA concept aircraft, the SUbsonic Single Aft eNgine (SUSAN) Electrofan, is such a vehicle. SUSAN is a series/parallel partial hybrid-electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed and implemented. This paper describes the development of some of these algorithms for system health management applied to the powertrain of the SUSAN concept aircraft.

Electrified Aircraft Propulsion↗

Piloted Evaluation of a Fault Recovery System for an Aircraft with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple tightly coupled subsystems, making them much more complex than traditional aircraft propulsion systems, both in terms of integration and control. Electrification enables aircraft to have multiple distributed thrust-producing fans that the flight control system can utilize for enhanced maneuverability, further increasing the control complexity. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept aircraft that leverages this technology. SUSAN is a series/parallel partial hybrid electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed, tested, validated, and implemented. This paper describes a piloted evaluation of such an algorithm in scenarios with multiple fan failures, performed in a flight simulator, demonstrating failure recovery and continued safe operation up to the limits of the powertrain. These scenarios are subsequently related to certification requirements.

Electrified Aircraft Propulsion↗

Piloted Evaluation of a Fault Recovery System for an Aircraft with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple tightly coupled subsystems, making them much more complex than traditional aircraft propulsion systems, both in terms of integration and control. Electrification enables aircraft to have multiple distributed thrust-producing fans that the flight control system can utilize for enhanced maneuverability, further increasing the control complexity. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept aircraft that leverages this technology. SUSAN is a series/parallel partial hybrid electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed, tested, validated, and implemented. This paper describes a piloted evaluation of such an algorithm in scenarios with multiple fan failures, performed in a flight simulator, demonstrating failure recovery and continued safe operation up to the limits of the powertrain. These scenarios are subsequently related to certification requirements.

Electrified Aircraft Propulsion↗

Piloted Evaluation of a Fault Recovery System for an Aircraft with Distributed Electric Propulsion

Electrified aircraft powertrains contain multiple tightly coupled subsystems, making them much more complex than traditional aircraft propulsion systems, both in terms of integration and control. Electrification enables aircraft to have multiple distributed thrust-producing fans that the flight control system can utilize for enhanced maneuverability, further increasing the control complexity. The SUbsonic Single Aft eNgine (SUSAN) Electrofan is a NASA concept aircraft that leverages this technology. SUSAN is a series/parallel partial hybrid electric single-aisle transport aircraft that takes advantage of its electrified powertrain to provide fuel burn and emissions benefits when compared to the state-of-the-art. Achieving these benefits requires an appropriately designed control architecture that coordinates the various powertrain and flight control subsystems. As such, the SUSAN aircraft is designed with a high level of automation, allowing it to properly manage coupled subsystems and react rapidly to failures and anomalies. To do this effectively, algorithms that perform component health management, fault detection, isolation, and accommodation, and continuous optimization, must be developed, tested, validated, and implemented. This paper describes a piloted evaluation of such an algorithm in scenarios with multiple fan failures, performed in a flight simulator, demonstrating failure recovery and continued safe operation up to the limits of the powertrain. These scenarios are subsequently related to certification requirements.

Electrified Aircraft Propulsion↗

DMS Advanced Applications for Accommodating High Penetrations of DERs and Microgrids: Preprint

Efficient and effective management of the electrical distribution system requires an integrated system approach for Distribution Management Systems (DMS), Distributed Energy Resources (DERs), Distributed Energy Resources Management System (DERMS), and microgrids to work in harmony. This paper highlights some of the outcomes from a U.S. Department of Energy (DOE), Office of Electricity (OE) project, including 1) Architecture of these integrated systems, and 2) Expanded functions of two example DMS applications, Volt-VAR optimization (VVO) and Fault Location, Isolation and Service Restoration (FLISR), to accommodate DER. For these two example applications, the relevant DER Group Functions necessary to support communication between DMS and Microgrid Controller (MC) in grid-tied mode are identified.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Hardware-in-the-Loop Testbed to Evaluate FLISR Implemented with OpenFMB

With the increasing complexity of the distribution smart grid architecture, algorithms such as the fault location, isolation, and service restoration (FLISR) scheme rely on robust communications that are resilient to natural and man-made adverse conditions and exhibit robustness. Existing communications infrastructure for information exchange are centralized at the distribution management system, with very little autonomy or intelligence at the grid-edge. As a first step towards achieving grid-edge self-healing, this paper aims to bridge this shortcoming by implementing a centrally coordinated rules-based FLISR scheme and integrating it with Open Field Message Bus (OpenFMB), which is a flexible publish-subscribe architecture with the potential to enable point-to-multipoint communications and is more robust and resilient to natural and man-made adverse conditions. A proof of concept is developed to validate the centrally coordinated FLISR and OpenFMB mounted on an SEL-3360 computer that interacts with a simple feeder network of five SEL-651R relays, an SEL-3530 RTAC, and a hardware-in-the-loop testbed. Results demonstrate the efficacy of this approach in enabling direct, low-latency information exchange. OpenFMB's publish-subscribe data model also opens new ways to enable grid-edge interoperability among devices of different vendors interacting with different protocols.

Sundararajan, Aditya↗

ADMS and DER Coordinated Capability Demonstrations to Assist Utilities to Increase Resilience and Reliability

The proliferation of distributed energy resources (DERs) presents opportunities and challenges to distribution grid operators. The National Renewable Energy Laboratory (NREL) and Survalent are collaborating to demonstrate advanced distribution management system (ADMS) and DER coordinated capability to assist utilities to increase resilience and reliability. ADMS and Distributed Energy Resource Management System (DERMS) Coordination for Peak Load Management (PLM). Fault Location, Isolation, and Service Restoration (FLISR) in the Presence of DERs. Grid-Edge Intelligent Distribution Automation System for Self-Healing Distribution Grids. These laboratory demonstrations use NREL's ADMS Test Bed.

ADMS↗

Hierarchical Data-Driven Protection for Microgrid with 100% Renewable Penetration: Preprint

The accurate detection and isolation of faults is critical for the reliable operation of microgrids (MGs). Traditional protection approaches are even more challenged for 100% renewable MGs because inverter-based resources (IBRs) are the only sources for fault current which are usually low and unpredictable/non-uniform. This calls for new protection scheme that can identify IBR fault responses and detect faults in MGs. Data-driven based protection can learn the pattern of IBR fault responses and make the correct decision to identify faults. Therefore, this paper presents a data-driven approach for fault localization in island MGs. The approach builds a training dataset of comprehensive fault scenarios that can be used to learn fault characteristics from processed measurements. The localization task is modeled as a binary classification problem at each relay, which simplifies the learning process. Then, a hierarchical decision mechanism is used to identify the fault location. The proposed approach is assessed using an exemplary MG with several grid-forming (GFM) and grid-following (GFL) inverters, where accurate estimation of fault location is achieved. The data-driven based protection approach developed in this paper provides a generic framework and useful guidance for power system protection engineers to achieve reliable protection for MGs with 100% renewables.

artificial intelligence↗

Condition monitoring and false alarm reducing of sensors in NPP - 222

With more and more application of digital I and C systems in nuclear power plants (NPP), more and more sensors are also required. Large amount of sensors really can make contribution to the condition monitoring of systems and equipment in NPP, whereas the heavy use also increases the malfunction risk of sensor self. Therefore the reliability and effectiveness of sensors must be guaranteed first. Thus the condition of sensors should be monitored first in a NPP. Since the precise mathematical models of sensors in complex systems are relative difficult to establish, however quantity of operating data can be easily obtained due to the wide application of digital I and C systems, thus this article adopts principal component analysis (PCA) to carry out condition monitoring for sensors. The PCA model developed for sensors is proved to be effective with operating data acquired from a real NPP. It can detect and isolate the fault when an artificial fault is imposed to the normal data. Then the monitoring results are further processed by another control limit (second confidence limit) besides T 2 and Q statistics (first confidence limit) in PCA. The value of second confidence limit is calculated based on the probability statistics of T 2 and Q statistics. And simulation tests show that the application of the second confidence limit can greatly reduce false alarms in the PCA model and the model performance can be greatly improved with the application of false alarms reducing method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

Advanced instrumentation concepts for environmental control subsystems

Design, evaluation and demonstration of advanced instrumentation concepts for improving performance of manned spacecraft environmental control and life support systems were successfully completed. Concepts to aid maintenance following fault detection and isolation were defined. A computer-guided fault correction instruction program was developed and demonstrated in a packaged unit which also contains the operator/system interface.

Yang, P. Y.↗

Methodologies for Adaptive Flight Envelope Estimation and Protection

This paper reports the latest development of several techniques for adaptive flight envelope estimation and protection system for aircraft under damage upset conditions. Through the integration of advanced fault detection algorithms, real-time system identification of the damage/faulted aircraft and flight envelop estimation, real-time decision support can be executed autonomously for improving damage tolerance and flight recoverability. Particularly, a bank of adaptive nonlinear fault detection and isolation estimators were developed for flight control actuator faults; a real-time system identification method was developed for assessing the dynamics and performance limitation of impaired aircraft; online learning neural networks were used to approximate selected aircraft dynamics which were then inverted to estimate command margins. As off-line training of network weights is not required, the method has the advantage of adapting to varying flight conditions and different vehicle configurations. The key benefit of the envelope estimation and protection system is that it allows the aircraft to fly close to its limit boundary by constantly updating the controller command limits during flight. The developed techniques were demonstrated on NASA s Generic Transport Model (GTM) simulation environments with simulated actuator faults. Simulation results and remarks on future work are presented.

Tang, Liang↗

Automated Contingency Management for Water Recycling System

To enable effective management, planning, and operations for future missions that involve a crewed space habitat, operational support must be migrated from Earth to the habitat. Intelligent System Health Management technologies (ISHM) promise to enable the future space habitats to increase the safety and mission success while minimizing operational risks. In this paper, Water Recycling System (WRS) deployed at NASA Ames Research Center's Sustainability Base is used for verification and validation of the proposed solution. Our work includes the development of the WRS simulation model based on its dynamic physical characteristics and the design of Automatic Contingency Management (ACM) framework that integrates fault diagnosis and optimization. In WRS modeling, a nominal model with fault injectors is developed. Fault detection and isolation techniques are then developed for isolating causes and identifying the severity of the faults. Dynamic Programming (DP) based fault mitigation strategies are designed to accommodate the faults in the system. A series of simulations are presented with different fault modes and the results indicate that the proposed ACM system can alleviate the fault in the WRS optimally regarding energy consumption and effects of the fault.

Systems Health Management↗

Aircraft Engine On-Line Diagnostics Through Dual-Channel Sensor Measurements: Development of a Baseline System

In this paper, a baseline system which utilizes dual-channel sensor measurements for aircraft engine on-line diagnostics is developed. This system is composed of a linear on-board engine model (LOBEM) and fault detection and isolation (FDI) logic. The LOBEM provides the analytical third channel against which the dual-channel measurements are compared. When the discrepancy among the triplex channels exceeds a tolerance level, the FDI logic determines the cause of the discrepancy. Through this approach, the baseline system achieves the following objectives: (1) anomaly detection, (2) component fault detection, and (3) sensor fault detection and isolation. The performance of the baseline system is evaluated in a simulation environment using faults in sensors and components.

Kobayashi, Takahisa↗