Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Sensitivity and Uncertainty Analysis of Generator Failures under Extreme Temperature Scenarios in Power Systems

This report summarizes work done under the Verification, Validation, and Uncertainty Quantification (VVUQ) thrust area of the North American Energy Resilience Model (NAERM) Program. The specific task of interest described in this report is focused on sensitivity analysis of scenarios involving failures of both wind turbines and thermal generators under extreme cold-weather temperature conditions as would be observed in a Polar Vortex event.

17 WIND ENERGY↗

TID, SEE and radiation induced failures in advanced flash memories

We report on TID and SEE tests of multi-level and higher density flash memories. Stand-by currents and functionality tests were used to characterize the response of radiation-induced failures. The radiation-induced failures can be categorized as followings: SEU read errors during irradiation, stuck-bit read errors verified post-irradiation, write errors, erase failures, multiple upsets, and single-event latch up.

Scheick, Leif Z.↗

WE-H-BRC-09: Simulated Errors in Mock Radiotherapy Plans to Quantify the Effectiveness of the Physics Plan Review

Purpose: A standard tool for ensuring the quality of radiation therapy treatments is the initial physics plan review. However, little is known about its performance in practice. The goal of this study is to measure the effectiveness of physics plan review by introducing simulated errors into “mock” treatment plans and measuring the performance of plan review by physicists. Methods: We generated six mock treatment plans containing multiple errors. These errors were based on incident learning system data both within the department and internationally (SAFRON). These errors were scored for severity and frequency. Those with the highest scores were included in the simulations (13 errors total). Observer bias was minimized using a multiple co-correlated distractor approach. Eight physicists reviewed these plans for errors, with each physicist reviewing, on average, 3/6 plans. The confidence interval for the proportion of errors detected was computed using the Wilson score interval. Results: Simulated errors were detected in 65% of reviews [51–75%] (95% confidence interval [CI] in brackets). The following error scenarios had the highest detection rates: incorrect isocenter in DRRs/CBCT (91% [73–98%]) and a planned dose different from the prescribed dose (100% [61–100%]). Errors with low detection rates involved incorrect field parameters in record and verify system (38%, [18–61%]) and incorrect isocenter localization in planning system (29% [8–64%]). Though pre-treatment QA failure was reliably identified (100%), less than 20% of participants reported the error that caused the failure. Conclusion: This is one of the first quantitative studies of error detection. Although physics plan review is a key safety measure and can identify some errors with high fidelity, others errors are more challenging to detect. This data will guide future work on standardization and automation. Creating new checks or improving existing ones (i.e., via automation) will help in detecting those errors with low detection rates.

60 APPLIED LIFE SCIENCES↗

Reliability Results of NERSC Systems

In order to address the needs of future scientific applications for storing and accessing large amounts of data in an efficient way, one needs to understand the limitations of current technologies and how they may cause systeminstability or unavailability. A number of factors can impact system availability ranging from facility-wide power outage to a single point of failure such as network switches or global file systems. In addition, individual component failure in a system can degrade the performance of that system. This paper focuses on analyzing both of these factors and their impacts on the computational and storage systems at NERSC. Component failure data presented in this report primarily focuses on disk drive in on of the computational system and tape drive failure in HPSS. NERSC collected available component failure data and system-wide outages for its computational and storage systems over a six-year period and made them available to the HPC community through the Petascale Data Storage Institute.

99 GENERAL AND MISCELLANEOUS↗

Preliminary Failure Modes and Effects Analysis of the US DCLL Test Blanket Module

This report presents the results of a preliminary failure modes and effects analysis (FMEA) of a small tritium-breeding test blanket module design for the International Thermonuclear Experimental Reactor. The FMEA was quantified with “generic” component failure rate data, and the failure events are binned into postulated initiating event families and frequency categories for safety assessment. An appendix to this report contains repair time data to support an occupational radiation exposure assessment for test blanket module maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Patterns of Failure After Proton Therapy in Medulloblastoma; Linear Energy Transfer Distributions and Relative Biological Effectiveness Associations for Relapses

Purpose: The pattern of failure in medulloblastoma patients treated with proton radiation therapy is unknown. For this increasingly used modality, it is important to ensure that outcomes are comparable to those in modern photon series. It has been suggested this pattern may differ from photons because of variations in linear energy transfer (LET) and relative biological effectiveness (RBE). In addition, the use of matching fields for delivery of craniospinal irradiation (CSI) may influence patterns of relapse. Here we report the patterns of failure after the use of protons, compare it to that in the available photon literature, and determine the LET and RBE values in areas of recurrence. Methods and Materials: Retrospective review of patients with medulloblastoma treated with proton radiation therapy at Massachusetts General Hospital (MGH) between 2002 and 2011. We documented the locations of first relapse. Discrete failures were contoured on the original planning computed tomography scan. Monte Carlo calculation methods were used to estimate the proton LET distribution. Models were used to estimate RBE values based on the LET distributions. Results: A total of 109 patients were followed for a median of 38.8 months (range, 1.4-119.2 months). Of the patients, 16 experienced relapse. Relapse involved the supratentorial compartment (n=8), spinal compartment (n=11), and posterior fossa (n=5). Eleven failures were isolated to a single compartment; 6 failures in the spine, 4 failures in the supratentorium, and 1 failure in the posterior fossa. The remaining patients had multiple sites of disease. One isolated spinal failure occurred at the spinal junction of 2 fields. None of the 70 patients treated with an involved-field-only boost failed in the posterior fossa outside of the tumor bed. We found no correlation between Monte Carlo-calculated LET distribution and regions of recurrence. Conclusions: The most common site of failure in patients treated with protons for medulloblastoma was outside of the posterior fossa. The most common site for isolated local failure was the spine. We recommend consideration of spinal imaging in follow-up and careful attention to dose distribution in the spinal junction regions. Development of techniques that do not require field matching may be of benefit. We did not identify a direct correlation between lower LET values and recurrence in medulloblastoma patients treated with proton therapy. Patterns of failure do not appear to differ from those in patients treated with photon therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A probabilistic assessment of PWR SNF cladding pinching failure considering potential transportation accident conditions

This report presents a probabilistic assessment of pressurized water reactor (PWR) spent nuclear fuel (SNF) rod cladding pinching failure triggered by a transportation accident, after 300 years of dry storage. Three thousand pinching scenarios, which were previously evaluated assuming a baseline 9-m cask drop and a horizontal impact on an unyielding surface, are reassessed assuming more realistic train transportation accidents. Each scenario was defined using Latin Hypercube Sampling (LHS) of SNF rod conditions and loading parameters, and it is simulated with a nonlinear finite element (FE) model. Cladding failure is evaluated under consideration of hydride-related embrittlement effects. The reassessment indicates that cladding pinching failure is not significantly affected by the assumptions on transportation accidents, but is rather controlled by other parameters, mainly the pellet-cladding gap width. The reevaluated, conditional failure probability ranges from 1.62 E-7 to 6.47 E-7, for 5,000 km of transportation by train.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

From cells to laminate: probing and modeling residual stress evolution in thin silicon photovoltaic modules using synchrotron X-ray micro-diffraction experiments and finite element simulations

Fracture of silicon crystalline solar cells has recently been observed in increasing percentages especially in solar photovoltaic (PV) modules involving thinner silicon solar cells (<200 μm). Many failures due to fracture have been reported from the field because of environmental loading (snow, wind, etc.) as well as mishandling of the solar PV modules (during installation, maintenance, etc.). However, a significantly higher number of failures have also been reported during module encapsulation (lamination) indicating high residual stress in the modules and thus more prone to cell cracking. Here in this paper we report through the use of synchrotron X-ray submicron diffraction coupled with physics-based finite element modeling, the complete residual stress evolution in mono-crystalline silicon solar cells during PV module integration process. For the first time, we unravel the reason for the high stress and cracking of silicon cells near soldered inter-connects. Our experiments revealed a significant increase of residual stress in the silicon cell near the solder joint after lamination. Moreover, our finite element simulations show that this increase of stress during lamination is a result of highly localized bending of the cell near the soldered inter-connects. Further, the synchrotron X-ray submicron diffraction has proven to be a very effective way to quantitatively probe mechanical stress in encapsulated silicon solar cells. Thus, this technique has ultimately enabled these findings leading to the enlightening of the role of soldering and encapsulation processes on the cell residual stress. This model can be further used to suggest methodologies that could lead to lower stress in encapsulated silicon solar cells, which are the subjects of our continued investigations.

14 SOLAR ENERGY↗

Spacecraft Electrical Connector Selection and Application Processes

This assessment was initiated by the NASA Engineering & Safety Center (NESC) after a number of recent "high profile" connector problems, the most visible and publicized of these being the problem with the Space Shuttle's Engine Cut-Off System cryogenic feed-thru connector. The NESC commissioned a review of NASA's connector selection and application processes for space flight applications, including how lessons learned and past problem records are fed back into the processes to avoid recurring issues. Team members were primarily from the various NASA Centers and included connector and electrical parts specialists. The commissioned study was conducted on spacecraft connector selection and application processes at NASA Centers. The team also compared the NASA spacecraft connector selection and application process to the military process, identified recent high profile connector failures, and analyzed problem report data looking for trends and common occurrences. The team characterized NASA's connector problem experience into a list of top connector issues based on anecdotal evidence of a system's impact and commonality between Centers. These top issues are as follows, in no particular rank order: electrically shorted, bent and/or recessed contact pins, contact pin/socket contamination leading to electrically open or intermittencies, connector plating corrosion or corrosion of connector components, low or inadequate contact pin retention forces, contact crimp failures, unmated connectors and mis-wiring due to workmanship errors during installation or maintenance, loose connectors due to manufacturing defects such as wavy washer and worn bayonet retention, damaged connector elastomeric seals and cryogenic connector failure. A survey was also conducted of SAE Connector AE-8C1 committee members regarding their experience relative to the NASA concerns on connectors. The most common responses in order of occurrence were contact retention, plating issues, worn-out or damaged coupling mechanisms, bent pins, contact crimp barrel cracking and torn seals. In addition to these common themes, responses included issues with markings, dimensional errors on the build, contact/socket damage (handling), manufacturing defects and customer misapplication and mishandling. The NESC team concluded that considering the large quantity and wide variety of connectors successfully flown on human and robotic space applications, the number of failures is quite low. However, "high profile" failures with significant cost, schedule, safety, and/or mission success impacts continue to occur. It was also concluded that connector failures occur throughout a system's life-cycle with the majority of connector issues application related. A number of recommendations were identified for improving NASA connector selection processes and overall space connector reliability and performance.

Iannello, Chris↗

Influence of gradation on failure mode of saturated sand at particle scale

Extensive research has been reported in the literature to characterize the failure mode of dry sand using various experimental techniques such as surface optical imaging, photo-elastic materials, three-dimensional (3D) computed tomography (CT), and 3D synchrotron micro-computed tomography (SMT). However, there is a limited literature about the behavior of saturated sand. This paper presents the results of axisymmetric triaxial compression (ATC) experiments that were conducted on saturated sand specimens. The behavior of specimens composed of a uniform sand with grain size between US sieves #40 and #50 is compared to specimens conducted on the same sand that has a wider gradation. 3D SMT technique was used to acquire 3D scans while shearing the specimens to probe localized events that are completely missed or misinterpreted when analyzing ATC measurements based on global standard measurements. The results show a higher effective principal stress ratio (EPSR) for the non-uniform specimen and a thicker shear band when compared to uniform specimen.

Elnur, Mohammed [University of Tennessee]↗

Developing Generic Prior Distributions for Common Cause Failure Alpha Factors and Causal Alpha Factors

This report is a revision of the original report, INL/LTD-17-43723. Distribution of the original report was to the Nuclear Regulatory Commission (NRC) only, and the report was not made available to the public. The original report was revised as this report for public distribution. This report presents the latest update of generic prior distributions for common cause failure (CCF) alpha factors, as well as the development of new generic prior distributions for CCF causal alpha factors. The history of CCF treatment and parameter estimations is reviewed. The existing process for developing generic prior distributions is reviewed and used to develop new priors for CCF alpha factors and causal alpha factors. For causal alpha factors, different priors are developed for the five different CCF cause groups: Component (GC), Design (GD), Environment (GE), Human (GH), and Other (GO). These generic prior distributions could be used in the Standardized Plant Analysis Risk (SPAR) models for CCF parameter estimation. The issues and preliminary thoughts regarding prior distribution development are documented. Potential future work is then proposed for improving the process of developing priors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Failure detection and isolation experiments with the Langley Mini-Mast

A report is presented on experiments to demonstrate failure detection and isolation (FDI) using the flexible truss facility Mini-Mast at the NASA Langley Research Center. Two techniques are selected for study because they are applicable both to sensor and actuator failures and because they do not depend on hypotheses about the forms of possible failures. These two are the method of generalized parity relations and the failure detection filter. These methods utilize the concept of analytical redundancy and therefore their performance depends on the fidelity of the model of the dynamics of the system being monitored. Results are given for sensor FDI using generalized parity relations and input-output data collected during operation of the Mini-Mast. component failures are simulated in the data. The dependence of the performance of the methods on choices of the parameters in their implementation is explored.

Vander Velde, Wallace E.↗

Twisting failure of centrally loaded open-section columns in the elastic range

In the following report a complete theory of twisting failure by the energy method is developed, based on substantially the same assumptions as those employed by Wagner and Bleich. Problems treated in detail are: the stress and strain condition under St. Venant twist and in twist with axial constraint; the concept of shear center and the energy method for problems of elastic stability.

Kappus, Robert↗

Detecting Hidden Failure Modes in Critical, Embedded Software

This experience report describes a method that has been used successfully to detect hidden failure modes in critical, embedded spacecraft software. The method is an adaptation of an earlier, controversial approach called failure modes and effects analysis. The adapted method was found to be well-suited to identifying latent software design weaknesses involving complex system interactions and dependencies in the two applications described here. This experience may be useful for other high-integrity software systems in which the possibility of hidden failure modes is a major concern.

detecting software failure design analysis↗

NGNP – Creating Validated TRL and TDRMs for Critical Systems, Subsystems, and Components

This report introduces two draft Next Generation Nuclear Plant (NGNP) Technology Development Roadmaps (TDRMs) and documents the methods used to create them. As such, this report depicts the development of the hardware needed to successfully operate the NGNP and identifies this hardware by the area of the plant it supports and by system, subsystem, and component (SSC). Several options exist for which technologies are selected to fulfill the functions of the NGNP. These options are represented by differing SSCs and are grouped into reference designs. Each SSC associated with each reference design is evaluated, rated, and assigned a technology readiness level (TRL). A rollup of the TRLs allows for comparison of the various reference designs. A TDRM then documents the tasks needed to obtain information in key discriminating criteria to support technology down selection and the tasks and test required to sufficiently mature the technology and reduce the likelihood of technological failure upon installation. This report presents the path forward, methods, and tools used to understand the requirements, manage the uncertainty, and mitigate the risk for the NGNP project. The key tool, TDRMs, is the means to facilitate NGNP risk-informed decision making, technology down selection, and technology qualification and maturation while serving to coordinate engineering, research and development, and licensing efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CompactPCI(Registered TradeMark) Connectors in Space Flight Applications

This report documents the current status of CompactPCI(Registered TradeMark) connectors in GSFC spaceflight applications. To the extent the information is known, this report summarizes to what component quality level each NASA contractor (referred to as OEM in this report) procured the parts, and what board level and system level testing was performed. The report also provides the current status of the reliability assessment for each GSFC project based on the results of testing and FMEA (Failure Mode Effects Analysis). This report addresses how the CompactPCI(Registered TradeMark) connectors came into existence, and how these became the connector style chosen by many designers of space flight hardware. It identifies the design philosophy and the lack of robustness which has led to several known failure modes. These failure modes include fretting of connector pins during vibration, shock and thermal cycling, exposure of underplating, and increased resistance, including brief excursions to very high resistance. Each of these are signs of aging, which becomes an increasing concern for long duration orbiting space flight applications. This report addresses the mitigation strategy to replace CompactPCI(Registered TradeMark) connectors with space qualified Hypertronics 2mm cPCI connectors. The Hypertronics 2mm cPCI connectors are pin-to-pin compatible with the CompactPCI(Registered TradeMark) connectors and meet all of the same technical requirements, except the ability to hot mate, and to mate directly with a CompactPCI of the opposite gender. A detailed comparison of the CompactPCI(Registered TradeMark) connector and the Hypertronics 2mm cPCI connector is provided to describe the ruggedness of Hypertronics connector for space flight applications. Finally, this report makes recommendations for flight hardware for the future missions where the hardware is yet to be built, as well as for the hardware which has already been built with CompactPCI(Registered TradeMark) connectors.

Williams, Richard↗

Failure Patterns After Hemithoracic Pleural Intensity Modulated Radiation Therapy for Malignant Pleural Mesothelioma

Purpose: We previously reported our technique for delivering intensity modulated radiation therapy (IMRT) to the entire pleura while attempting to spare the lung in patients with malignant pleural mesothelioma (MPM). Herein, we report a detailed pattern-of-failure analysis in patients with MPM who were unresectable or underwent pleurectomy/decortication (P/D), uniformly treated with hemithoracic pleural IMRT. Methods and Materials: Sixty-seven patients with MPM were treated with definitive or adjuvant hemithoracic pleural IMRT between November 2004 and May 2013. Pretreatment imaging, treatment plans, and posttreatment imaging were retrospectively reviewed to determine failure location(s). Failures were categorized as in-field (within the 90% isodose line), marginal (<90% and ≥50% isodose lines), out-of-field (outside the 50% isodose line), or distant. Results: The median follow-up was 24 months from diagnosis and the median time to in-field local failure from the end of RT was 10 months. Forty-three in-field local failures (64%) were found with a 1- and 2-year actuarial failure rate of 56% and 74%, respectively. For patients who underwent P/D versus those who received a partial pleurectomy or were deemed unresectable, the median time to in-field local failure was 14 months versus 6 months, respectively, with 1- and 2-year actuarial in-field local failure rates of 43% and 60% versus 66% and 83%, respectively (P=.03). There were 13 marginal failures (19%). Five of the marginal failures (38%) were located within the costomediastinal recess. Marginal failures decreased with increasing institutional experience (P=.04). Twenty-five patients (37%) had out-of-field failures. Distant failures occurred in 32 patients (48%). Conclusions: After hemithoracic pleural IMRT, local failure remains the dominant form of failure pattern. Patients treated with adjuvant hemithoracic pleural IMRT after P/D experience a significantly longer time to local and distant failure than patients treated with definitive pleural IMRT. Increasing experience and improvement in target delineation minimize the incidence of avoidable marginal failures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗