Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development and Evaluation of Titanium Space Suit Bearings

The Z-2 Prototype Planetary Extravehicular Space Suit Assembly is a continuation of NASA's Z series of spacesuits, designed with the intent of meeting a wide variety of exploration mission objectives, including human exploration of the Martian surface. Incorporating titanium bearings into the Z series space suit architecture allows us to reduce mass by an estimated 23 pounds per suit system compared to the previously used stainless steel bearing designs without compromising suit functionality. There are two obstacles to overcome when using titanium for a bearing race: 1) titanium is flammable when exposed to the oxygen wetted environment inside the space suit and 2) titanium's poor wear properties are often challenging to overcome in tribology applications. In order to evaluate the ignitability of a titanium space suit bearing, a series of tests were conducted at White Sands Test Facility that introduced the bearings to an extreme test profile, with multiple failures imbedded into the test bearings. The testing showed no signs of ignition in the most extreme test cases; however, substantial wear of the bearing races was observed. In order to design a bearing that can last an entire exploration mission (approximately 2 years), bearing test rigs were developed that allow for the quick evaluation of various bearing ball loads, ball diameters, lubricants, and surface treatments. This test data will allow designers to minimize the titanium bearing mass for a specific material and lubricant combination around a maximum contact stress that will allow the bearing to survive the life of an exploration mission. This paper reviews the current research and testing that has been performed on titanium bearing races to evaluate the use of such materials in an enriched oxygen environment and to optimize the bearing assembly mass and tribological properties to accommodate for the high bearing cycle life for an exploration mission.

Rhodes, Richard↗

Evolution of Permeability in Sandstone During Confined Brazilian Testing

Permeability measurements were made on sandstone during confined Brazilian strength tests. The test involves 50 mm diameter disk-shaped, jacketed samples that are subjected to confining stresses while they are diametrically loaded. Specially designed end caps allow for concurrent gas flow measurements. The test configuration allows for the samples to be subjected to a range of stresses, with the confining stress as the intermediate principal stress. Furthermore, the majority of the tests measured permeability during loading to failure in the confined extension region. The permeability of the sandstone sample increases significantly well before the peak load is reached due to newly formed microcracks that continue to coalesce and dilate with further loading. Permeability increases are inversely proportional to the intermediate principal stress as increased confining pressures suppress growth, coalescence, and dilation of microcracks. Additional testing includes unloading and reloading cycles prior to failure. With each unloading–reloading cycle, permeability at comparable stresses is increased compared to the previous cycle, consistent with increasing damage in the form of an expanding microcrack network.

58 GEOSCIENCES↗

Installation effects on performance of multiple model V/STOL lift fans

An experimental program was performed in which the individual performance of multiple VTOL model lift fans was measured. The model tested consisted of three 5.5 in. diameter tip-turbine driven model VTOL lift fans mounted chordwise in a two-dimensional wing to simulate a pod-type array. The performance data provided significant insight into possible thrust variations and losses caused by the presence of cover doors, adjacent fuselage panels, and adjacent fans. The effect of a partial loss of drive air supply (simulated gas generator failure) on fan performance was also investigated. The results of the tests demonstrated that lift fan installation variables and hardware can have a significant effect on the thrust of the individual fans.

Diedrich, J. H.↗

Lessons Learned from Large-Scale Aerospace Structural Testing

Large-scale testing of aerospace structures is frequently the final step in a development project to validate the structural performance, and that step typically involves a large cost and time investment. To ensure that the testing provides the required data, avoiding errors that can result in an unsuccessful test and failure to meet objectives is critical. Five lessons learned are presented herein to provide insight to those conducting tests in order to help them avoid known pitfalls that may result in an unsuccessful test. Five large-scale tests are described, and include two composite wing tests, a composite hybrid-wing body center section test, a full-scale 27.5-ft diameter metallic barrel test, and an 8-ft diameter metallic barrel test. Problems identified during the testing and mitigation approaches to solve the problems are presented, then the lessons learned are identified and discussed.

Lessons Learned↗

Evaluation of thermal energy storage for central receiver concentrating solar power plants under charging cycles through structural assessment

Electricity production by concentrated solar power (CSP) systems has stood out among energy transition alternatives due to their large generation capacity (between 30 MW and 400 MW) and high capacity factor (80%) when incorporating thermal storage systems (TES). Although TES tanks in operation worldwide are made of austenitic steels with remarkable mechanical and anticorrosive properties, operational failures have been reported due to low-cycle fatigue, creep, and the abrupt release of residual stresses generated during tank manufacturing. A critical operation for salt tanks is the initial daily charging operation, given the low fluid level and the thermal gradients between the inventory and the salt entering the tank. This study presents a structural simulation of a 39.6 m-diameter molten salt tank for central receiver CSP plants, accounting for temperature and pressure variations during charging and different sparger ring inlet configurations. The initial pre-stressed condition of the floor, resulting from the manufacture of welded plates, is used as a boundary condition. The fatigue and creep life analyses were performed in accordance with the ASME BPVC and API standards. It was found that the tank's floor is in a less favourable mechanical condition than the wall, due to its initial manufacturing condition and the maximum temperature differences during charging. A critical zone was identified in an area affected by residual stress on the floor and under the sparger ring. The baseline sparger ring configuration, with 52 2-inch-diameter orifices and a flow direction of 90 degrees , results in an average floor stress of approximately 25 MPa and creep damage after 1.2 years of tank operation.

14 SOLAR ENERGY↗

Defining the Optimal Planning Target Volume in Image-Guided Stereotactic Radiosurgery of Brain Metastases: Results of a Randomized Trial

Purpose: To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Methods and Materials: Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board–approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diameters less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator–based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Results: Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non–small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in neurocognition or quality of life was observed. Conclusions: SRS was well tolerated, with low rates of LR and RN in both cohorts. However, given the higher potential risk of RN with a 3-mm margin, a 1-mm GTV expansion is more appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Lightning Current Propagation in Electrical Conduit

Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 ohms, or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.

47 OTHER INSTRUMENTATION↗

Lessons Learned from Large-Scale Aerospace Structural Testing

Large-scale testing of aerospace structures is frequently the final step in a development project to validate the structural performance, and that typically involves a large cost and time investment. In order to ensure that the testing provides the required data, avoiding errors that can result in an unsuccessful test and failure to meet objectives is critical. Presented herein are five lessons learned to provide insight to those conducting tests in order to help them avoid known pitfalls that may result in an unsuccessful test. Five subject large-scale tests are described, and include two composite wing tests, a composite hybrid-wing body center section test, a full-scale 27.5-ft diameter metallic barrel test, and an 8-ft diameter metallic barrel test. Problems identified during the testing and mitigation approaches to solve the problems are presented, then the lessons learned are summarized.

Lessons Learned↗

Lessons Learned from Large-Scale Aerospace Structural Testing

Large-scale testing of aerospace structures is frequently the final step in a development project to validate the structural performance, and that typically involves a large cost and time investment. In order to ensure that the testing provides the required data, avoiding errors that can result in an unsuccessful test and failure to meet objectives is critical. Presented herein are five lessons learned to provide insight to those conducting tests in order to help them avoid known pitfalls that may result in an unsuccessful test. Five subject large-scale tests are described, and include two composite wing tests, a composite hybrid-wing body center section test, a full-scale 27.5-ft diameter metallic barrel test, and an 8-ft diameter metallic barrel test. Problems identified during the testing and mitigation approaches to solve the problems are presented, then the lessons learned are summarized.

Lessons Learned↗

Influence of necking propensity on the dynamic-tensile-extrusion response of fluoropolymers

The quasi-static and dynamic responses of two fluoropolymers - polytetrafluoroethylene (PTFE) and polychlorotrifluoroethylene (PCTFE) - have been extensively characterized. Here we investigate the influence of the propensity to neck or not between PCTFE and PTFE on their responses under Dynamic-Tensile-Extrusion (Dyn-TenExt). The Dyn-Ten-Ext technique was originally developed for metals and applied to copper and tantalum spheres by Gray, et al. as a tensile corollary to compressive Taylor Cylinder Impact Testing. Under Taylor Cylinder loading both PTFE and PCTFE exhibit a classic three-diameter ductile deformation pattern. The ductile-to-brittle transition in PTFE occurs at 131 m s{sup -1} with a very tight transition range in impact stress of less than 4 m s{sup -1}. Conversely, the ductile-to-brittle transition in PCTFE occurs between 165 and 200 m s{sup -1} with a gradual transition to stochastic crack formation and ultimately failure. Under Dyn-Ten-Ext loading the onset of extrusion occurs above 164 and 259 m s{sup -1} for PTFE and PCTFE respectively.

36 MATERIALS SCIENCE↗

Strength, stiffness, and microstructure of Cu(In,Ga)Se{sub 2} thin films deposited via sputtering and co-evaporation

This work examines Cu(In,Ga)Se{sub 2} thin films fabricated by (1) selenization of pre-sputtered Cu-In-Ga and (2) co-evaporation of each constituent. The efficiency disparity between films deposited via these two methods is linked to differences in morphology and microstructure. Atomic force microscopy and scanning electron microscopy show that selenized films have rougher surfaces and poor adhesion to molybdenum back contact. Transmission electron microscopy and electron energy loss spectroscopy revealed multiple voids near the Mo layer in selenized films and a depletion of Na and Se around the voids. Residual stresses in co-evaporated films were found to be ∼1.23 GPa using wafer curvature measurements. Uniaxial compression experiments on 500 nm-diameter nanopillars carved out from co-evaporated films revealed the elastic modulus of 70.4 ± 6.5 GPa. Hertzian contact model applied to nanoindentation data on selenized films revealed the indentation modulus of 68.9 ± 12.4 GPa, which is in agreement with previous reports. This equivalence of the elastic moduli suggests that microstructural differences manifest themselves after the yield point. Typical plastic behavior with two distinct failure modes is observed in the extracted stress-strain results, with the yield strength of 640.9 ± 13.7 MPa for pillars that failed by shearing and 1100.8 ± 77.8 MPa for pillars that failed by shattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Status of Additive Manufacturing Capabilities for Processing Refractory Alloys Under the Mo-99 Program

The enriched 100 Mo target, denoted as aMo, that Northstar Medical Radioisotopes is developing to produce 99 Mo from an accelerator-based method is a disk-type geometry with a 0.5–0.715 mm thickness and a 29 mm outer diameter. A press and sinter method was adopted to fabricate these samples from aMo powder feedstock. Inherent porosity from the press and sinter method makes the disks more easily dissolvable during 99 Mo postprocessing. However, the disk-type geometry will be subject to thermal stresses due to temperature variations once the geometry is in line with the accelerated electron beam, causing warping and possible failure. Additive manufacturing (AM) processes such as laser powder bed fusion (LPBF) enable the manufacturing of custom, complex geometries that may otherwise be difficult to produce with more conventional methods (e.g., press and sinter approach). Therefore, the National Nuclear Security Administration’s Molybdenum-99 Program invested in developing an AM facility dedicated to processing and printing refractory powders. This report details the LPBF process, how irregular refractory powder can be prepared for LPBF, and the equipment that is available to support the program.

36 MATERIALS SCIENCE↗

CHARACTERIZATION OF RADIOACTIVITY IN THE REACTOR VESSEL OF THE HEAVY WATER COMPONENT TEST REACTOR

The Heavy Water Component Test Reactor (HWCTR) facility is a pressurized heavy water reactor that was used to test candidate fuel designs for heavy water power reactors. The reactor operated at nominal power of 50 MW{sub th}. The reactor coolant loop operated at 1200 psig and 250 C. Two isolated test loop were designed into the reactor to provide special test conditions. Fig. 1 shows a cut-away view of the reactor. The two loops are contained in four inch diameter stainless steel piping. The HWCTR was operated for only a short duration, from March 1962 to December 1964 in order to test the viability of test fuel elements and other reactor components for use in a heavy water power reactor. The reactor achieved 13,882 MWd of total power while testing 36 different fuel assemblies. In the course of operation, HWCTR experienced the cladding failures of 10 separate test fuel assemblies. In each case, the cladding was breached with some release of fuel core material into the isolated test loop, causing fission product and actinide contamination in the main coolant loop and the liquid and boiling test loops. Despite the contribution of the contamination from the failed fuel, the primary source of radioactivity in the HWCTR vessel and internals is the activation products in the thermal shields, and to a lesser degree, activation products in the reactor vessel walls and liner. A detailed facility characterization report of the HWCTR facility was completed in 1996. Many of the inputs and assumptions in the 1996 characterization report were derived from the HWCTR decommissioning plan published in 1975. The current paper provides an updated assessment of the radioisotopic characteristics of the HWCTR vessel and internals to support decommissioning activities on the facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of boron epoxy rocket motor chambers.

A 71 cm diameter 74 cm length boron/epoxy composite rocket motor chamber was designed based on the geometric configuration of the JPL Applications Technology Satellite titanium alloy apogee motor chamber. Because analyses showed large stress concentrations in the domes, the configuration was modified using the same basic constraints for openings and attachments. The rocket motor chamber was then fabricated by filament winding with boron/epoxy tape and hydrostatically tested to failure at 264 N/sq cm, 57.2 N/sq cm above the design value. Two more rocket motor chambers were fabricated with the same basic constraints, but shortened to 57.6 cm for a smaller propellant load. The first of these short chambers failed in proof because of filament winding fabrication difficulties. The second chamber was successfully fabricated and passed the hydrostatic proof test.

Jensen, W. M.↗

Effect of alternately high and low repeated stresses upon the fatigue strength of 25S-T aluminum alloy

Fatigue tests were made on one lot of 3/4 inch diameter rolled-and-drawn 25S-T aluminum-alloy rod normal in composition and tensile properties. The specimens were tested at 3500 cycles per second in a rotating-beam fatigue test machine. Tests were made for three ratios (20:1, 50:1, and 200:1) of the number of cycles applied at low stress to the number applied at high stress. In general, failure occurred when the number of cycles at either the low or the high stress approached the ordinary fatigue curve for the material, regardless of the sequence in which the stresses were applied.

Stickley, G W↗

Production and Characterization of Carbon Nanotubes and Nanotube-Based Composites

The Nobel Prize winning discovery of the Buckuball (C60) in 1985 at Rice University by a group including Dr. Richard Smalley led to the whole new class of carbon allotropes including fullerenes and nanotubes. Especially interesting from many viewpoints are single-walled carbon nanotubes, which structurally are like a single graphitic sheet wrapped around a cylinder and capped at the ends. This cylinders have diameter as small as 0.5 - 2 nm (1/100,000th the diameter of a human hair) and are as long as 0.1 - 1 mm. Nanotubes are really individual molecules and believed to be defect-free, leading to high tensile strength despite their low density. Additionally, these fibers exhibit electrical conductivity as high as copper, thermal conductivity as high as diamond, strength 100 times higher than steel at one-sixth the weight, and high strain to failure. Thus it is believed that developments in the field of nanotechnology will lead to stronger and lighter composite materials for next generation spacecraft. Lack of a bulk method of production is the primary reason nanotubes are not used widely today. Toward this goal JSC nanotube team is exploring three distinct production techniques: laser ablation, arc discharge and chemical vapor deposition (CVD, in collaboration with Rice University). In laser ablation technique high-power laser impinges on the piece of carbon containing small amount of catalyst, and nanotubes self-assemble from the resulting carbon vapor. In arc generator similar vapor is created in arc discharge between carbon electrodes with catalyst. In CVD method nanotubes grow at much lower temperature on small catalyst particles from carbon-containing feedstock gas (methane or carbon monoxide). As of now, laser ablation produces cleanest material, but mass yield is rather small. Arc discharge produces grams of material, but purity is low. CVD technique is still in baby steps, but preliminary results look promising, as well as perspective of scaling the process up. We are also working on necessary purification of nanotubes. Applications of nanotubes are in such various fields as lightweight composites, molecular electronics, energy storage (electrodes in Li ion batteries), flat panel displays, conductive polymers, etc. JSC nanotube team is focused on development of lightweight materials. We work on the injection thermoset epoxies reinforced with nanotubes. Early results show good wetting of nanotube surface with epoxy, which is very important. More research will be possible as more nanotubes become available.

Nikolaev, Pavel↗