Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

TRISO SiC Failure Probability for Reactivity Initiated Accidents in High-Temperature Gas-Cooled Reactors

This work analyzes the failure process of the silicon carbide (SiC) layer in tristructural isotropic (TRISO) during reactivity-initiated accident scenarios for a high-temperature gas-cooled reactor (HTGR) with BISON. Two cases are considered—a group control rod withdrawal (CRW) and a control rod ejection (CRE)—reproduced from a previous study. Failure probability is modeled using Weibull statistics, and worst-case scenario Weibull parameters are adopted to simulate the envelopes in BISON with a one-dimensional TRISO model. CRW scenario results are characterized by higher values of maximum energy deposition and final temperature and volumetric strain with respect to the CRE ones, but the latter have remarkably higher SiC failure probability, mainly due to the offset in strain rates between the two cases. This work also confirms the validity and conservatism of the performance envelopes produced in a previous work by replicating the envelope formulation using RELAP5-3D and RAVEN with a different sampling technique and obtaining consistent results. A sensitivity analysis using the Sobol variance decomposition method on SiC failure probability is then performed involving a set of inputs on both CRW and CRE. The two most important parameters are Weibull modulus and characteristic stress, and their relative importance depends on the specific case. The proposed interpretation of the results is that both energy deposition and strain rate influence the relative degree of importance of the failure parameters. Computation of 95% confidence intervals around worst-case scenario SiC failure probability values is also carried out for four different sets of Weibull parameters. Heren a new criterion for SiC TRISO quality classification built upon safety-based ranges of Weibull parameters is proposed to be integrated in future Fuel-Production Quality Assurance Plans.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Efficient and Reliable Power Takeoff for Ocean Wave Energy Harvesting

The project goal is to significantly improve the current ocean wave energy harvesting through innovative Power Take-off (PTO) design, advanced power electronics, and novel wave capture structures. The objective of the project is to design and demonstrate system-agnostic components for application across multiple MHK systems, and complete component designs, build scaled prototypes, and perform testing and analysis for metric validation of 25% increase in component rating/per unit cost and 50% reduction in failure rate. The major innovation of the PTO is the Mechanical Motion Rectifier (MMR) mechanism that rectifies the bi-directional oscillatory motion of the input from waves into a steady unidirectional rotation output to directly drive the electrical generator. Through this mechanism, the efficiency and the fatigue life of the PTO can be significantly improved to benefit the energy absorption and lifespan of the wave energy converters (WEC). During the period of performance, the component and system design are completed, the scaled prototypes are developed and performed testing. It is validated that the 25% increase in a component rating/per unit cost. The 50% reduction in failure rate is not directly validated by experiments, however, it can be explained qualitatively with analysis. Besides, 8 journal articles, 13 conference proceedings, 1 patent, 3 Master thesis and two Ph.D. dissertations are published based on the work related to this project. The list of all the publications can be found at the end of the project as an appendix. Over 30 students and postdocs were trained through this project. Three prototypes of 100W and 500W WECs and 10KW PTO were designed, built, and tested in ocean wave tank and using the NREL dynamometer. This project demonstrated 50-80% PTO efficiency, 90-98% power electronics efficiency, up to 66% capture width ratio in irregular waves, and 34% overall efficiency in regular waves.

16 TIDAL AND WAVE POWER↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining failure properties of as-received and hydrided unirradiated Zircaloy-4 from ring compression tests

An integrated experimental and computational approach was developed to determine the plastic strain at fracture and to investigate the fracture energy of as-received and hydrided unirradiated Zircaloy-4 nuclear cladding tubes in the hoop direction at room temperature from ring compression testing (RCT). This work builds on previous methods in the literature that were developed to obtain the mechanical properties of nuclear cladding before fracture (Young’s modulus, yield stress, and strain-hardening parameters) from experimental RCT results and extends the characterization of this material class to include material failure properties. Furthermore, a ductile damage approach was developed and implemented in a validated finite element model to predict material failure, evaluate fracture energy, and quantify the plastic strain at fracture initiation. The hydrogen content of the Zircaloy-4 specimens was varied up to 610 wppm when the failure became brittle. As expected, increasing hydrogen content caused embrittlement of the Zircaloy-4 samples tested and the plastic strain at fracture and fracture energy to decrease.

36 MATERIALS SCIENCE↗

Towards generic memory forensic framework for programmable logic controllers

A Programmable Logic Controller (PLC) is a microprocessor-based controller that is used to automate physical processes in critical infrastructure and various other industries and manufacturing sectors. Initially, PLCs were completely isolated from the Internet, and cyber security was not incorporated at the time of development. The introduction of industry 4.0 and the evolution of ICS systems to communicate over public IP addresses from the Internet enhanced productivity and efficiency, but Internet connectivity exposed the systems and their vulnerabilities, which led to an increase in cyber attacks. When a system is sabotaged/compromised, security analysts need to get to the root cause of the attack as quickly as possible to recover the system. To do so, memory forensic analysis is critical to provide a unique insight into the run-time memory activities and extract a reliable source of evidence. In this paper, we analyze the memory structure of the Schneider Electric Modicon M221 PLC. To build a memory profile, we reverse engineer the communication protocol and conduct differential analysis to gain knowledge about the structure of the memory and the low-level representation of control logic instructions. We then identify dynamic and static memory regions by modifying different project fields and conducting differential analysis, which allows us to identify boundaries of critical memory structures and extract important forensic artifacts that can be found in the memory. The Python implementation of the memory profile can help reduce the time and effort required for manual analysis in case of cyber incident or system failure.

97 MATHEMATICS AND COMPUTING↗

Stress Field Dynamics and Fault Slip Potential in the Paradox Basin

Abstract The Paradox Basin, straddling Utah, Colorado, Arizona, and New Mexico is characterized by an intricate amalgamation of evaporites and clastic layers and is dominated by prominent salt walls and related subsurface structures. Our research offers a new examination of the stress distribution across the basin, deriving from continuous and discrete stress measurements conducted in boreholes in the region and focal mechanism analysis, emphasizing variations over salt structures. Integrating Coulomb failure criteria with probabilistic methods, we assess potential fault movements resulting from fluid pressure alterations. Our approach provides a comprehensive understanding of the Paradox Basin's state of stress, showing a continuous change of the maximum horizontal stress orientation from N‐S at the Wasatch Fault Zone to WNW‐ESE in the northern part of the Paradox Basin and to WSW‐ENE in the southern part of the basin. Further East, into the Colorado Plateau and the Uncompahgre Uplift, the S H max orientation becomes E‐W. Decoding stress orientation dynamics has enabled critical insights into fault slip potential, especially in the basin's northern region. The salt wall faults are less likely to slip, and the Paradox Formation's evaporite and clastic rock sequence can serve as a potential low seismic risk target for carbon storage and hydrocarbon extraction.

Geochemistry & Geophysics↗

Extension of Clad Damage Propagation Model for Fission Gas Dispersal and Two-Phase Flow Effects in MOOSE SubChannel Module

This report presents an extension of the Clad Damage Propagation (CDAP) model implemented in the MOOSE SubChannel Module (SCM) to capture post-failure fission-gas dispersal and two-phase flow effects in sodium-cooled fast reactor assemblies. The extended model tracks discharged gas axially and radially, computes channel-averaged flow quality and void fraction using a Lockhart–Martinelli framework, evaluates two-phase frictional pressure-drop multipliers, determines inlet mass-flow degradation under fixed core pressures, and applies an intensified-void-based heat-transfer degradation to affected fuel pins. Radial plume expansion is parameterized using mineral-oil jet experiments mapped to sodium conditions via Reynolds–Weber similarity. Implementation details are documented, along with the new methods and user inputs needed to control plume mapping and two-phase behavior. Demonstration simulations for 19- and 37-pin bundles show that breach size and inlet velocity strongly influence propagation potential: small breaches (≤0.5 mm) produce limited degradation while larger breaches (~1 mm) can drive oscillatory temperature spikes and enhanced failure propagation, especially at higher velocities. These results demonstrate that the extended CDAP model provides a more complete framework for quantifying cladding damage propagation and evaluating propagation potential in transient scenarios. The approach remains computationally efficient, consistent with subchannel-level analysis, yet incorporates sufficient physics to bridge localized post-failure effects with bundle- and assembly-scale degradation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wind turbine main bearing rating lives as determined by IEC 61400‐1 and ISO 281: A critical review and exploratory case study

Abstract This paper studies the rating lives of wind turbine main bearings, as determined by the IEC 61400‐1 and ISO 281 standards. A critical review of relevant bearing life theory and turbine design requirements is provided, including discussion on possible shortcomings such as the existence (or not) of the bearing fatigue load limit and the validity of assuming linear damage accumulation. A detailed exploratory case study is then undertaken to determine rating lives for two models of main bearing in a 1.5 MW wind turbine. Rating life assessment is carried out under different conditions, including various combinations of main bearing temperature, wind field characteristics, lubricant viscosity, and contamination levels. Rating lives are found to be sufficiently above the desired 20‐year design life for both bearing models under expected operating conditions. For the larger bearing, operational loads are shown to be below or close to the bearing fatigue load limit a vast majority of the time. Key sensitivities for rating life values are temperature and contamination. Overall, the results of this study suggest that an ISO 281 rating life assessment does not account for reported rates of main bearing failures in 1 to 3 MW wind turbines. It is recommended that a similar analysis be undertaken for ISO/TS 16281 rating lives, along with further efforts to identify principal root causes of main bearing failures in future work, possibly leading to a new application standard specific to this component. It is also recommended that the impacts of partial wake impingement on main bearing rating lives are investigated.

17 WIND ENERGY↗

Evaluation of Power Transmission Lines Hardening Scenarios Using a Machine Learning Approach

The power transmission infrastructure is vulnerable to extreme weather events, particularly hurricanes and tropical storms. A recent example is the damage caused by Hurricane Maria (H-Maria) in the archipelago of Puerto Rico in September 2017, where major failures in the transmission infrastructure led to a total blackout. Numerous studies have been conducted to examine strategies to strengthen the transmission system, including burying the power lines underground or increasing the frequency of tree trimming. However, few studies focus on the direct hardening of the transmission towers to accomplish an increase in resiliency. This machine learning-based study fills this need by analyzing three direct hardening scenarios and determining the effectiveness of these changes in the context of H-Maria. A methodology for estimating transmission tower damage is presented here in this study as well as an analysis of impact of replacing structures with a high failure rate with more resilient ones. We found the steel self-support-pole to be the best replacement option for the towers with high failure rate. Furthermore, the third hardening scenario, where all wooden poles were replaced, exhibited a maximum reduction in damaged towers in a single line of 66% while lowering the mean number of damaged towers per line by 10%.

54 ENVIRONMENTAL SCIENCES↗

Overcoming Communications Outages in Inverter Downtime Analysis: Preprint

Inverters are often reported to be the highest-impact failure point in PV systems. This importance is belied by the simplistic assumptions about inverter downtime losses used in industrial energy modeling. Energy models often assume the extent of inverter-related losses is limited to 1% of annual production from scheduled inverter preventative maintenance. In reality, inverter-related production losses are much more variable, although data from large-scale surveys of fielded systems are rare. Here we present a method of detecting inverter downtime events and estimating the associated lost production using inverter- and meter-level power data. Because communications outages are of similar frequency to true production outages, the method pays particular attention to distinguishing communications outages from true production outages. The results of applying the method at fleet-scale are presented and discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Directed energy deposition of Haynes 282 nickel superalloy

Laser powder directed energy deposition was employed to fabricate Haynes® 282 Ni-based superalloy for high temperature creep testing. Material was heat treated using a single-step aging heat treatment of 800 °C for 4 h. Microstructural analysis was conducted in the as-deposited, solution-annealed, and age-hardened conditions. γ′ precipitates were absent in the as-deposited and annealed condition but formed during aging with an average size of 48.5 ± 12 nm. γ’ denuded zones ranging in thickness from 73 to 469 nm were observed adjacent to an effectively continuous grain boundary carbide film that covered 72.5% of the measured boundary length. The heat-treated material contained a high-volume fraction of TiC carbides ranging in size from 38 to 457 nm. Electron backscatter diffraction showed partial recrystallization, with 77-83% recrystallized area and a heterogeneous grain-size distribution. Creep testing at 750 °C at 300, 320, and 350 MPa revealed significantly inferior performance compared to wrought material, with higher strain rates, earlier tertiary onset, and shorter rupture lives. Fractography shows that failure was dominated by intergranular rupture. Post rupture microstructural analysis results suggest that the creep behavior was primarily governed by the non-equilibrium interface network rather than the bulk γ/γ’ matrix. In conclusion, the findings indicate that achieving wrought-like creep performance necessitates substantial improvements in the additive process, specifically focusing on enhanced homogenization, full recrystallization, and precise control over the morphology and distribution of carbides.

36 - MATERIALS SCIENCE↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

Field Experience Detecting PV Underperformance in Real Time Using Existing Instrumentation

Maintenance at large-scale photovoltaic plants employs a mix of preventative and corrective maintenance practices. Large outages, such as an inverter tripping offline, are often easy to detect. More subtle sub-inverter faults and failures can accumulate and go unnoticed for months or years. A software-based fault detection method has been developed to analyze commonly measured data from large-scale PV plants for more timely detection of subtle underperformance. The method has been demonstrated on eight datasets from large-scale plants with high accuracy of detection. Results are validated using aerial infrared scanning. String outages are detected with a true positive rate of 73 percent and tracker issues are detected with a true positive rate of 88 percent. The developed method can be uniformly applied to photovoltaic plants across a range of scales and configurations to assess performance, quickly detect underperformance, and determine the source and location of failures. The results inform and improve operations and maintenance at PV plants, ultimately aiding in improved affordability, reliability, availability, and resiliency of solar electricity.

14 SOLAR ENERGY↗

Equibiaxial flexural strength determination of UO 2 using a ball-on-ring test

To increase nuclear fuel performance and reliability, their mechanical properties require an accurate and statistically relevant assessment. Biaxial flexural strength tests provide an alternative to bend bar techniques for assessing mechanical behavior; namely, the transverse rupture strength (TRS) of ceramic samples. Biaxial test samples require simple geometries and minimal surface preparation, reducing fabrication costs and handling hazards. This study investigated the TRS of polycrystalline UO 2 fuel forms at room temperature using a ball-on-ring test fixture. Here, pellets were fabricated from UO 2 powder using conventional powder processing and sintering techniques. The TRS and Weibull parameters were obtained through Weibull statistics on over 60 UO 2 samples tested under equibiaxial flexure. The larger sample size in this study enabled a more robust Weibull statistical analysis than alternative test methods, which may not capture the stochastic failure of typical ceramics. Furthermore, two different loading ball diameters were employed to assess the impact of contact damage on fracture strength. While Hertzian contact damage was observed with the smaller loading ball, the fracture strength remained unaffected. A fracture analysis of the tested UO 2 samples indicated a mixture of intergranular and transgranular fracture that transitions to transgranular fracture with increasing distance from the fracture origin. The characteristic strength of the combined data sets was determined to be 148 MPa, and the Weibull modulus was determined to be 9.1. The TRS values and Weibull parameters were close to values found in the literature for alternative testing techniques using samples with similar microstructure and density. The findings in this study validate the ball-on-ring method used to obtain the TRS of UO 2 with a sample geometry more representative of nuclear fuels. Additionally, experimental TRS results from this study can be implemented in modeling codes to predict fuel performance, which is critical to fuel burnup extension and advanced nuclear fuel technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Centrifuge modeling and numerical analysis on lateral performance of mono-bucket foundation for offshore wind turbines

The lateral loading performance of the mono-bucket foundation for offshore wind turbines is investigated in this study through a series of centrifuge tests and numerical analysis. Six mono-bucket models are considered to assess the influences of aspect ratio under the ultimate condition. The FE model is validated against the centrifuge test results, and the failure mechanism of the foundation is revealed. The parametric study and sensitivity analysis of the soil parameters are performed in the numerical simulations. A modified theoretical calculation method is proposed to estimate the ultimate lateral capacity of the suction bucket foundation by solving the limit equilibrium equations. A correction term is added in the calculation using the “m” method. The position of the rotation center is calculated, demonstrating a better accuracy compared to the previously reported geometric method. The modified calculation method is verified against the field test, the centrifuge test, and the laboratory test. The method is proved to be applicable in estimating the lateral performance of the mono-bucket foundation in a general form. Finally, this study aims to provide well-documented data and design references for practical engineers.

17 WIND ENERGY↗

Recent Experience with the CMS Data Management System

The CMS[1] experiment manages a large-scale data infrastructure, currently handling over 200 PB of disk and 500 PB of tape storage and transferring more than 1 PB of data per day on average between various WLCG[2] sites. Utilizing Rucio[3] for high-level data management, FTS[4] for data transfers, and a variety of storage and network technologies at the sites, CMS confronts inevitable challenges due to the system’s growing scale and evolving nature. Key challenges include managing transfer and storage failures, optimizing data distribution across different storages based on production and analysis needs, implementing necessary technology upgrades and migrations, and efficiently handling user requests. The data management team has established comprehensive monitoring to supervise this system and has successfully addressed many of these challenges. The team’s efforts aim to ensure data availability and protection, minimize failures and manual interventions, maximize transfer throughput and resource utilization, and provide reliable user support. This paper details the operational experience of CMS with its data management system in recent years, focusing on the encountered challenges, the effective strategies employed to overcome them and the ongoing challenges as we prepare for future demands.

Öztürk, Hasan [CERN]↗

Nucleation-mediated reshaping of facetted metallic nanocrystals: Breakdown of the classical free energy picture

Shape stability is key to avoiding degradation of performance for metallic nanocrystals synthesized with facetted non-equilibrium shapes to optimize properties for catalysis, plasmonics, and so on. Reshaping of facetted nanocrystals is controlled by the surface diffusion-mediated nucleation and growth of new outer layers of atoms. Here, Kinetic Monte Carlo (KMC) simulation of a realistic stochastic atomistic-level model is applied to precisely track the reshaping of Pd octahedra and nanocubes. Unexpectedly, separate constrained equilibrium Monte Carlo analysis of the free energy profile during reshaping reveals a fundamental failure of the classical nucleation theory (CNT) prediction for the reshaping barrier and rate. Why? Nucleation barriers can be relatively low for these processes, so the system is not locally equilibrated before crossing the barrier, as assumed in CNT. This claim is supported by an analysis of a first-passage problem for reshaping within a master equation framework for the model that reasonably captures the behavior in KMC simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗