Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “environmental monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

An Intelligent Adaptable Monitoring Package. Final Report

The “Intelligent Adaptable Monitoring Package” project was a four-year effort that demonstrated the feasibility of integrated sensing packages at tidal and wave energy sites. Such integration is generally required by the breadth of sensors required to understand environmental effects at marine energy sites and the operational difficulty of deploying, maintaining, and recovering such sensors. Over the course of the project, the Adaptable Monitoring Package (AMP) was deployed in multiple settings, each corresponding to a project budget period: - Budget Period 1: Demonstration of cabled deployment at Pacific Northwest National Laboratory’s Marine Science Laboratory. The deployment highlighted AMP hardware endurance over a 4-month deployment in a tidally-dominated environment and laid the groundwork for machine learning algorithms to detect and classify targets present in active sonar data. - Budget Period 2: Demonstration of an autonomous deployment at PacWave South off the coast of Newport, Oregon. The deployment highlighted the stability of AMP hardware and software, with the autonomous package collecting data on a duty cycle over a 1.5-month deployment. - Budget Period 3: Demonstration of an autonomous deployment powered by a wave energy converter at the U.S. Navy’s Wave Energy Test Site. The deployment highlighted the potential of wave energy to power ocean observatories and led to the development of machine learning algorithms to detect and classify targets in optical camera data. In aggregate, this project’s greatest success was demonstrating the AMP’s flexibility in a range of deployment scenarios. Each budget period represented a “first of a kind” demonstration of integrated instrumentation – cabled AMP, autonomous AMP, wave-energy powered AMP – and each deployment helped to identify and set goals for the next. Further, despite the exploratory nature of these deployments, each one achieved high system up-time and proved that flexible integration of multiple sensors in a single package represents a viable strategy for marine energy environmental monitoring. The key lessons learned from the project are: - Without continuous power, either from a shore cable or in situ source, many of the benefits of integration are lost (If continuous power is not available, the ability to detect rare events is lost, as is the ability to minimize the risk of behavioral changes through adaptive sensing. However, even on a duty cycle, there is still value in being able to acquire synchronous data from multiple sensors.); and - Observations from a moving platform present substantially greater data processing challenges than those from stationary platforms. Finally, these deployments also demonstrate an important truth: successful integration alone does not guarantee that relevant data are collected. To grow the knowledge base about environmental interactions with marine energy converters, integrated systems, like the AMP, need to include the right sensor mix and connect the data pipelines to effective processing algorithms. These deployments establish a strong foundation for future collaborations with the environmental research community: not only to understand the environmental effects of marine energy, but also to improve our general ability to study life in the sea.

16 TIDAL AND WAVE POWER↗

Radiological Monitoring Plan for the Oak Ridge Y-12 National Security Complex: Surface Water

DOE Order 458.1 requires that dose estimates consider contributions from all facilities. In the Y-12 Radiological Monitoring Plan (RMP), surface water is monitored at points that reflect individual facilities, as well as at points that reflect the combined contributions of all facilities. This monitoring plan does not consider other potential routes (i.e., airborne releases and food chains). Thus, a complete determination of total effective dose (TED) cannot be made based on this plan alone. The other routes from Y-12, and all routes from other DOE facilities on the Oak Ridge Reservation (e.g., Oak Ridge National Laboratory (ORNL) and The Heritage Center), must be considered in order to satisfy DOE Order 458.1 requirements. Determination of TED from all sites and pathways is done through the use of dose-assessment models and is documented in the Annual Site Environmental Report. This monitoring plan provides adequate monitoring goals for Y-12 surface water releases to provide input of sufficient sensitivity and accuracy to reliably determine the Y-12 surface water component of the TED. The routine radiological monitoring program is designed to monitor effluents at four types of locations: (1) treatment facilities, (2) other point and area source discharges, (3) instream locations, and (4) production building roof run-off. With this sampling and analysis program, data will be obtained on primary point sources as well as on locations that represent the composite of other potential sources. This plan will be reviewed periodically to determine necessary modifications to the sampling frequencies, parameters, and locations. Modifications, if any, will be based on the analysis of the previous data and its effectiveness in satisfying the objectives of this plan. Appendix A contains graphs of the sum of the DCS fractions for locations and frequencies contained in a previous version of this plan. The data was collected from January 2009 through December 2019. Each sample was analyzed, and each result was divided by the appropriate DCS to compute a DCS fraction. These fractions were summed for all isotopes. According to DOE –STD-1196-2011, the annual average of these sums should be below 1.

54 ENVIRONMENTAL SCIENCES↗

The Cryosphere/Ocean Distributed Acoustic Sensing (CODAS) Experiment

Distributed acoustic sensing (DAS) has a demonstrated potential for wide-scale and continuous in situ monitoring of near-surface environmental and anthropogenic processes. DAS is attractive for development as a multi-geophysical observatory due to the prevalence of existing fiber infrastructure in regions with environmental, cultural, or strategic significance. To evaluate the efficacy of this technology for monitoring of polar environmental processes, we collected DAS data from a 37-km long section of seafloor telecommunications fiber located on the continental shelf of the Beaufort Sea, Alaska. This experiment spanned eight, one-week, seasonally-distributed periods across two years. This was the first ever deployment of seafloor DAS beneath sea ice, and the first deployment in any marine environment to span multiple seasons. We recorded a variety of environmental and anthropogenic signals with demonstrable utility for the study of sea ice dynamics and tracking of ocean vessels and ice-traversing vehicles.

54 ENVIRONMENTAL SCIENCES↗

Nevada National Security Site Environmental Report 2019

This report presents the National Nuclear Security Administration Nevada Field Office environmental protection and monitoring programs data and the compliance status for calendar year 2019 at the Nevada National Security Site and at its two support facilities, the North Las Vegas Facility and the Remote Sensing Laboratory-Nellis. This report also addresses environmental restoration projects conducted by the Environmental Management Nevada Program Office at the Tonopah Test Range.

54 ENVIRONMENTAL SCIENCES↗

Cost Efficiency of Environmental DNA as Compared to Conventional Methods for Biodiversity Monitoring Purposes at Marine Energy Sites

The installation of marine energy systems may affect marine environments, and by extension, marine fish communities. Therefore, biomonitoring is an integral part of assessing impacts on species. Environmental DNA (eDNA) provides a noninvasive alternative to conventional monitoring surveys and the possibility of a more accurate assessment of species richness. Yet, its cost efficiency compared to traditional methods of monitoring is relatively unknown, especially when applied to monitoring around tidal, wave, and offshore wind energy installations. For this study, 202 peer-reviewed journal articles were dissected to inventory the diversity of supplies used for collecting and processing eDNA samples and to compile the average cost of eDNA surveys. Information collected included the type, volume, and brand of containers used in sampling; material, size, and brand of filters; and extraction methods. Cost information was gathered for the most common supplies, and a total cost was estimated for a hypothetical eDNA survey in Sequim Bay, WA, to compare with traditional methods of surveying such as beach seining and scuba surveys. The results showed a higher-than-expected diversity of supplies to collect and process eDNA samples. The most common supplies were 1 L Nalgene bottles at an average cost of 7.96 USD for collecting samples, 0.45 µm glass fiber Merck Millipore filters at an average cost of 1.51 USD for filtering samples, and the Qiagen DNeasy Blood and Tissue kit at 3.54 USD per sample for extracting DNA. When compared to beach seine and scuba surveys, eDNA surveys undertaken by senior researchers are less expensive for both initial surveys with all new materials as well as for follow-up surveys reusing some of the supplies. However, when surveys are done solely by students, eDNA surveys are more expensive than scuba surveys when no prior supplies are available and more than both beach seine and scuba surveys for follow-up surveys reusing supplies. In a professional sphere, where surveys are less often conducted by teams of students only, eDNA surveys are an effective and less-costly alternative to conventional methods. We anticipate that the development and refinement of eDNA methodology will continue to decrease surveying costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NRAP Recommended Practices for Containment Assurance and Leakage Risk Quantification

This report presents recommendations for quantitatively assessing and managing leakage risk and effective containment assurance at geologic carbon storage (GCS) sites, amidst uncertainty in site characteristics and performance. These recommended practices are a product of the U.S. Department of Energy’s (DOE) Office of Fossil Energy and Carbon Management’s National Risk Assessment Partnership (NRAP)—a multi-year collaborative research effort of Lawrence Berkeley National Laboratory, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, National Energy Technology Laboratory, and Pacific Northwest National Laboratory. These recommended practices are organized as a set of conceptual workflows that correspond with the stages of the GCS project lifecycle. They consider aspects of site characterization, quantification of potential leakage, assessing the spatial extent of potential environmental impacts, optimizing monitoring design for detection of potential leakage, evaluation of concordance between monitored and forecasted reservoir response, assessing conformance with expected/accepted performance, and determination of the timeline over which risk of impactful leakage can be expected to abate. These conceptual workflows are intended to aid stakeholders in making risk management decisions at GCS sites and to support development of sound, risk-based justifications for characterizing the subsurface, defining area of potential leakage impact, designing site monitoring plans, selecting leakage risk management/mitigation alternatives, and estimating site closure timelines.

54 ENVIRONMENTAL SCIENCES↗

SRS Composite Analysis Monitoring Plan (FY2019 Model Validation)

Using a projected end-state date of 2065 (SRNS 2015b), the Savannah River Site (SRS) Composite Analysis (CA) modeling for each facility and waste site began on the inventory year assigned to it so that source depletion and radionuclide transport out of the system could be appropriately captured. Some SRS waste sites that have already achieved their end states (i.e. end-state inventories and end-state configuration) are currently contributing to the potential off-site public dose through source release, groundwater transport, discharge to on-site surface streams, and stream transport to the CA point of assessments (POAs). The inventory year assigned to these waste sites is 2002 or before. This means that SRS CA results from 2002 and beyond are a reasonable representation for these waste sites that have already achieved their end states and are currently contributing to the potential off-site public dose. The SRS Annual Environmental Report (AER) monitoring can differentiate and separate liquid pathway data allowing the data representing only waste sites at their end state to be produced. Because the SRS CA has projected reasonable end-state impacts from 2002 and beyond, and the AER monitoring can differentiate and separate operating and end-state contributions to annual liquid pathway release, an opportunity exists to use the AER monitoring data to validate the SRS CA model. The CA model validation program uses a graded and systematic approach for taking corrective action, starting with an SRS established administrative dose limit of 15 mrem/yr, below which no action is required. Based on the location of the 2010 SRS CA POAs, the only potential exposure pathway for the public is through surface water. The completion of the FY2019 CA model validation indicates that the SRS CA projected dose, while generally conservative, provides a reasonable representation of the maximum annual doses. These doses are well below the administrative limit; therefore, no additional action is required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model Validation for the FY2021 SRS Composite Analysis Monitoring Plan

Using a projected end-state date of 2065 (SRNS 2015b), the Savannah River Site (SRS) Composite Analysis (CA) modeling for each facility and waste site began on the inventory year assigned to it so that source depletion and radionuclide transport out of the system could be appropriately captured. Some SRS waste sites that have already achieved their end states (i.e., end-state inventories and end-state configuration) are currently contributing to the potential off-site public dose through source release, groundwater transport, discharge to on-site surface streams, and stream transport to the CA point of assessments (POAs). The inventory year assigned to these waste sites is 2002 or before. This means that SRS CA results from 2002 and beyond are a reasonable representation for these waste sites that have already achieved their end states and are currently contributing to the potential off-site public dose. The SRS Annual Environmental Report (AER) monitoring can differentiate and separate liquid pathway data allowing the data representing only waste sites at their end state to be produced. Because the SRS CA has projected reasonable end-state impacts from 2002 and beyond, and the AER monitoring can differentiate and separate operating and end-state contributions to annual liquid pathway release, an opportunity exists to use the AER monitoring data to validate the SRS CA model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mapping of Benthic Habitats at Marine Renewable Energy Sites Using Multibeam Echosounder and Sediment Profile Imaging Technologies

Objectives/Scope: The goal of this work was to develop a consistent and semi-automated seafloor survey method for generating high-resolution, benthic habitat maps for environmental assessments and monitoring of marine renewable energy sites. Sediment profile and plan view imaging (SPI/PV) technology was combined with multibeam bathymetry and acoustic backscatter methods to demonstrate a rapid, cost-effective benthic mapping protocol. A key technical innovation of this project was the development of an image processing platform that automatically measures key features from the images. Methods: Multibeam echosounder (MBES) acoustic and SPI/PV surveys were conducted at three coastal areas off the U.S. west coast, including the PacWave South energy test site off of Newport, Oregon. Point data on physical and biological sediment conditions obtained from the SPI/PV imagery were used to efficiently ground-truth the high-resolution MBES bathymetry and backscatter mosaics. The SPI camera is an optical corer that obtains an undisturbed 21 by 15 cm, high-resolution, cross-sectional image of the sediment–water interface and upper sediment column. The plan view camera attached to the SPI camera frame captures a downward looking view of the seabed immediately before the SPI image is obtained. As part of this project, we developed a computer vision image processing platform (iSPI) that uses deep convolutional neural networks and other approaches to automatically identify and measure key features in the images, such as grain size and surface relief. Results: Detailed benthic habitat maps were generated using this mapping approach for three different marine settings. The sites mapped included a silt-dominated embayment; a sloping, nearshore, transitional very fine to coarse sand bottom; and a medium, sand-dominated continental shelf marine energy test site. In each case, acoustic and imaging surveys were completed in less than week, and detailed benthic habitat maps were generated within 60 days. The results were placed within the Coastal and Marine Ecological Classification Standard (CMECS) habitat mapping framework, and various combinations of the bathymetry, backscatter, and SPI and PV data were used to generate CMECS component maps. Novel Information: This project developed and demonstrated a repeatable and cost-effective approach for efficiently mapping benthic habitat conditions over broad areas of the seafloor by combining state-of-the-art acoustic and imaging techniques. The primary survey tools used in this project have been used previously in both the offshore renewable (wind) and oil and gas sectors to map and monitor benthic environments. This project’s innovations include 1) the focused use of high-resolution SPI/PV imagery to ground-truth acoustic mosaics, and 2) the development of a computer automated image analysis processing tool that both streamlines and standardizes the generation of data from the imagery and makes the data extraction process more cost-effective and repeatable.

13 HYDRO ENERGY↗

Advances in PFAS Monitoring and Remediation Using a Functionalized Material Approach - 20080

The growing global concerns about the effects to public health from human exposure to per- and polyfluoroalkyl substances (PFAS) motivates the development of strategies for reliable monitoring of PFAS in environmental streams, as well as for their rapid, effective removal if detected. For the continuous PFAS monitoring, an inexpensive, field-deployable, in situ sensor is urgently needed; yet the prevalent in situ techniques often struggle to strike a balance between the practical sensitivity and selectivity demands of the real world. Similarly, for effective PFAS removal, strategies for their fast, selective, and quantitative capture are desired, yet the present commercially available sorbents are unable to meet the requirements of rapid, quantitative capture of all PFAS components, and are notably inefficient in removing the more toxic smaller chains. To address these twin challenges, Pacific Northwest National Laboratory is developing strategies for improved detection and remediation of PFAS. For the rapid, selective, quantitative removal of PFAS from environmental streams, the strategy relies on designing capture probes with exclusively tailored electronic and spatial affinities for the PFAS that are able to selectively capture them from environmental streams. For the in situ detection and quantification of PFAS in complex, multicomponent matrices such as groundwater, the approach relies on the targeted capture of specific PFAS by these PFAS-specific capture probes immobilized on a platform. The platform acts as an electrode to directly measure PFAS concentration through a proportional change in electrical response upon their capture. A combination of optimization of platform design and incorporation of additional, sensitive detection modalities have allowed us to achieve detection limits as low as 0.5 ng/L for detection of PFAS compounds (compared to the 70 ng/L Health Advisory Limit of the U.S. Environmental Protection Agency). (authors)

47 OTHER INSTRUMENTATION↗

Roadmap for the Completion of the Design and Implementation of a Remote Canister Monitoring System

The Office of Environmental Management within the Department of Energy is currently investigating technical issues associated with extended dry storage (50+ years) of aluminum spent nuclear fuel. As part of these efforts, a remote canister-monitoring system (RCMS) has been proposed to collect the real-time data of the environmental conditions in the canisters used for the dry storage of aluminum spent nuclear fuel in the CPP-603 facility at Idaho National Laboratory (INL). The proposed RCMS would provide the opportunity to evaluate the appropriate technologies for monitoring, to collect canister environment conditions as soon as possible, to verify and validate current laboratory-based study results and analytic modeling approaches, and to potentially identify additional dry storage options for aluminum spent nuclear fuel at the INL Site. The document provides a brief update on the progress that has been made toward deploying the RCMS and will present at a high level, the general system design philosophy behind the project and the key future tasks necessary for the completion of the RCMS system design, fabrication of the RCMS prototype, testing, and eventual deployment of the RCMS, and a tentative timeline for these tasks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-time bioelectronic sensing of environmental contaminants

Real-time chemical sensing is crucial for applications in environmental and health monitoring. Biosensors can detect a variety of molecules through genetic circuits that use these chemicals to trigger the synthesis of a coloured protein, thereby producing an optical signal. However, the process of protein expression limits the speed of this sensing to approximately half an hour, and optical signals are often difficult to detect in situ. Here we combine synthetic biology and materials engineering to develop biosensors that produce electrical readouts and have detection times of minutes. Here we programmed Escherichia coli to produce an electrical current in response to specific chemicals using a modular, eight-component, synthetic electron transport chain. As designed, this strain produced current following exposure to thiosulfate, an anion that causes microbial blooms, within 2 min. This amperometric sensor was then modified to detect an endocrine disruptor. The incorporation of a protein switch into the synthetic pathway and encapsulation of the bacteria with conductive nanomaterials enabled the detection of the endocrine disruptor in urban waterway samples within 3 min. Our results provide design rules to sense various chemicals with mass-transport-limited detection times and a new platform for miniature, low-power bioelectronic sensors that safeguard ecological and human health.

59 BASIC BIOLOGICAL SCIENCES↗

Nanocompression of 20 nm Silver Nanoparticles: In situ Aberration‐Corrected TEM and Atomistic Simulations

Single‐crystalline nanoparticles play an increasingly important role in a wide variety of fields including pharmaceuticals, advanced materials, catalysts for fuel cells, energy materials, as well as environmental detection and monitoring. Yet, the deformation mechanisms of very small nanoparticles are still poorly understood, in particular the role played by single dislocations and their interaction with surfaces. Here, in this work, silver nanoparticles with particularly small dimensions (≈20 nanometers in diameter) are compressed in situ in an aberration‐corrected transmission electron microscopy (TEM) and molecular dynamics (MD) simulations. During compression, the emergence of both dislocations and nanotwins are observed. However, these defects prove to be unstable and disappear upon removal of the indenter. Atomistic simulations confirm the role played by image stresses associated with the nearby surfaces and the reduction in dislocation line length as it approaches the free surface, thereby supporting the experimental observations. These results provide justification for the frequent observation of the absence of dislocations in nanoparticles of a few nanometers in size during in situ experiments, even after significant deformation. This phenomenon contributes to the self‐healing of samples through dislocation ejection toward the surfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of a Biological Chelator, Lanmodulin, on Minor Actinide Aqueous Speciation and Transport in the Environment

Minor actinides are major contributors to the long-term radiotoxicity of nuclear fuels and other radioactive wastes. Here in this context, understanding their interactions with natural chelators and minerals is key to evaluating their transport behavior in the environment. The lanmodulin family of metalloproteins is produced by ubiquitous bacteria and Methylorubrum extorquens lanmodulin (LanM) was recently identified as one of nature’s most selective chelators for trivalent f-elements. Herein, we investigated the behavior of neptunium, americium, and curium in the presence of LanM, carbonate ions, and common minerals (calcite, montmorillonite, quartz, and kaolinite). We show that LanM’s aqueous complexes with Am(III) and Cm(III) remain stable in carbonate-bicarbonate solutions. Furthermore, the sorption of Am(III) to these minerals is strongly impacted by LanM, while Np(V) sorption is not. With calcite, even a submicromolar concentration of LanM leads to a significant reduction in the Am(III) distribution coefficient (K d , from >10 4 to ~10 2 mL/g at pH 8.5), rendering it even more mobile than Np(V). Thus, LanM-type chelators can potentially increase the mobility of trivalent actinides and lanthanide fission products under environmentally relevant conditions. Monitoring biological chelators, including metalloproteins, and their biogenerators should therefore be considered during the evaluation of radioactive waste repository sites and the risk assessment of contaminated sites.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Thermochemical Properties of a Water-Soluble Zr(IV)-Flavonolate Complex for Fluoride Sensing

Detection of fluoride in water samples is critical for monitoring many chemical, environmental, and biological processes, however, these measurements often rely on costly instrumentation. Here, this situation has motivated the design of simple to use, fieldable fluoride sensors. Previously, a fluorometric sensor based on (EDTA)­Zr­(H 2 O) 2 (EDTA = ethylenediamine-N,N,N′,N′-tetraacetate) and 3-hydroxyflavone (FlvH) was reported for fluoride detection in ethanol-H 2 O mixtures. Herein, we report the synthesis and characterization of the previously proposed Zr­(IV)-flavonolate complex as the dimethylammonium salt, [(EDTA)­Zr­(Flv)]­[NMe 2 H 2 ] (Flv = 3-hydroxyflavonolate), and detail its utility for aqueous fluoride sensing. This species exhibits an intense blue fluorescence upon excitation with near-UV light (λ ex = 390 nm; λ em = 460 nm) that is quenched in the presence of NaF (100 mM acetate buffer, pH = 5) with good sensitivity (LOD = 20.9 nM; [F – ] from 10 –8 to 10 –4 M) under neat aqueous conditions. The equilibrium constant (K eq = 1.26 ± 0.00184 × 10 8 M –2 ) and free energy (Δ$G^°_{\textrm{rxn}}$ = –11.0 kcal mol –1 ) were determined under the conditions used for fluoride sensing, indicating a highly favorable reaction with F – in water. Finally, we developed paper-based sensing strips for qualitative fluoride sensing by immobilizing the sensor in a deposited gel enabling good selectivity and reduced interference due to slower ion diffusion.

aqueous chemistry↗

Trace Key Mechanistic Features of the Arsenite Sequestration Reaction with Nanoscale Zerovalent Iron

Nanoscale zerovalent iron (nZVI) is considered as a highly efficient material for sequestrating arsenite, but the origin of its high efficacy as well as the chemical transformations of arsenite during reaction is not well understood. Here, in this study, we report an in situ X-ray absorption spectroscopy (XAS) study to investigate the complex mechanism of nZVI reaction with arsenite under anaerobic conditions at the time scale from seconds to days. The time-resolved XAS analysis revealed a gradual oxidation of As III to As V in the course of minutes to hours in both the solid and liquid phase for the high (above 0.5 g/L) nZVI dose system. When the reaction time increased up to 60 days, As V became the dominant species. The quick-scanning extended X-ray absorption fine structure (QEAXFS) was introduced to discover the transient intermediate at the highly reactive stage, and a small red-shift in As K-edge absorption edge was observed. The QEAXFS combined with density functional theory (DFT) calculation suggested that the red-shift is likely due to the electron donation in a Fe-O-As complex and possible active sites of As sequestrations include Fe(OH) 4 and 4-Fe cluster. This is the first time that the transient reaction intermediate was identified in the As-nZVI sequestration system at the fast-reacting early stage. This study also demonstrated usefulness of in situ monitoring techniques in environmental water research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional metal–organic frameworks as effective sensors of gases and volatile compounds

Developing efficient sensor materials with superior performance for selective, fast and sensitive detection of gases and volatile organic compounds (VOCs) is essential for human health and environmental protection, through monitoring indoor and outdoor air pollutions, managing industrial processes, controlling food quality and assisting early diagnosis of diseases. Metal–organic frameworks (MOFs) are a unique type of crystalline and porous solid material constructed from metal nodes (metal ions or clusters) and functional organic ligands. They have been investigated extensively for possible use as high performance sensors for the detection of many different gases and VOCs in recent years, due to their large surface area, tunable pore size, functionalizable sites and intriguing properties, such as electrical conductivity, magnetism, ferroelectricity, luminescence and chromism. The high porosity of MOFs allows them to interact strongly with various analytes, including gases and VOCs, thus resulting in easily measurable responses to different physicochemical parameters. Although much of the recent work on MOF-based luminescent sensors have been summarized in several excellent reviews (up to 2018), a comprehensive overview of these materials for sensing gases and VOCs based on chemiresistive, magnetic, ferroelectric, and colorimertic mechanisms is missing. In this review, we highlight the most recent progress in developing MOF sensing and switching materials with an emphasis on sensing mechanisms based on electricity, magnetism, ferroelectricity and chromism. We provide a comprehensive analysis on the MOF–analyte interactions in these processes, which play a key role in the sensing performance of the MOF-based sensors and switches. We discuss in detail possible applications of MOF-based sensing and switching materials in detecting oxygen, water vapor, toxic industrial gases (such as hydrogen sulfide, ammonia, sulfur dioxide, nitrous oxide, carbon oxides and carbon disulfide) and VOCs (such as aromatic and aliphatic hydrocarbons, ketones, alcohols, aldehydes, chlorinated hydrocarbons and N,N'-dimethylformamide). Altogether, this review serves as a timely source of information and provides insight for the future development of advanced MOF materials as next-generation gas and VOC sensors.

36 MATERIALS SCIENCE↗