Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Energy use of residential safety, security, and health devices

Miscellaneous electrical loads (MELs) are responsible for a significant fraction of energy consumption in buildings. This paper addresses one category of MELs: Safety, Security, and Health Devices (SSHDs). Common SSHDs include: electrical life safety equipment, smoke alarms, radon mitigation fans, and home oxygen concentrators. The installation or use of these devices is dictated by building codes, health providers, insurance companies, and other entities—none of which would ordinarily consider energy efficiency a priority. For this project, the most important residential devices were explored in terms of their governing regulations, functions, technologies, and energy use. The power consumption of 41 life safety SSHDs were measured. Individual power consumption of life safety devices is very small but many are typically required in every home. Devices performing the same functions have wide ranges in power use. Opportunities for reducing SSHD energy use were investigated, the results are summarized, and recommendations are made for further actions that could be taken to reduce SSHD energy use. Finally, SSHDs identified in this paper are responsible for at least one percent of current U.S. residential electricity consumption, but that number will climb steadily as existing buildings are upgraded and new types of SSHDs appear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State-Level Employment Projections for Four Clean Energy Technologies in 2025 and 2030

As states and local governments weigh how to spur economic growth, stimulate job creation, and simultaneously adapt to meet climate goals, modern energy codes, and energy demand, this report provides a simple and transparent method to estimate the size of the workforce needed to support modeled deployments for energy efficiency in buildings, stationary battery energy storage (BES), solar photovoltaics (PV), and land-based wind in 2025 and 2030. In addition to a straightforward estimation method, this report includes state-level job estimates for two different deployment scenarios: a business-as-usual scenario and a more accelerated deployment scenario. The scope of the technologies included in this report is limited to four key energy technologies within the power sector that have strong job growth prospects and widespread geographic deployment potential. Although the included technologies are not all-encompassing, they have generated specific interest from state energy offices across the nation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Economic analysis of CCUS: Accelerated development for CO 2 EOR and storage in residual oil zones under the context of 45Q tax credit

Residual oil zones (ROZ) undergoing CO 2 Enhanced Oil Recovery (CO 2 -EOR) may benefit from specific strategies to maximize their value. We evaluated several strategies for producing from a Permian Basin, West Texas, USA field’s ROZ. This ROZ lies below the main pay zone (MPZ) of the field. Such brownfield ROZs occur in the Permian Basin and elsewhere. Since brownfield ROZs are hydraulically connected to the MPZs, development sequences and schemes influence oil production, CO 2 storage, and net present value (NPV). We conducted economic assessments of various CO 2 injection/production schemes in the stacked ROZ-MPZ reservoir based on flow simulations of a high-resolution geocellular model built from wireline logs and core data and calibrated through production history matching. Flow simulations of water alternating gas (WAG) injection, such as switching injection from the MPZ to the ROZ and commingled production, were studied. Simulation results showed that simultaneous CO 2 injection into the MPZ and ROZ lead to the largest oil production and, generally, the largest NPV. If instead, CO 2 was simultaneously injected into the MPZ and ROZ, then into the ROZ alone, this maximized CO 2 storage. CO 2 storage can be used as a tax credit under the Internal Revenue Code, Section 45Q. Storage performance depends on the development approach and WAG ratio. Developing the ROZ increased storage compared to only producing from the MPZ. The WAG ratio to maximize oil production did not always yield the largest NPV. These findings are potentially applied to other Brownfield ROZs, which are common below San Andres reservoirs in the Permian Basin and other basins. ROZ development can increase oilfields’ NPV and carbon storage potential. Our study can serve as an analog for similar reservoirs. Here this work provides valuable insights into the further optimization of brownfield ROZ development and information for operators to plan to develop stacked ROZ-MPZ reservoirs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

Unvented roof assemblies have been accepted in North American building codes since 2007; code-compliant construction calls for a minimum thickness of “air-impermeable insulation” (based on climate zone) to avoid cold-weather condensation and moisture risks. This is typically implemented with polyurethane spray foam insulation; however, negatives of this material include high first cost and possible adverse environmental impacts. Implementing unvented roofs in a moisture-safe manner with air-permeable fibrous fill insulations (e.g., fiberglass or cellulose) could potentially reduce the first cost of unvented roof designs, allowing for more widespread use. Building unvented roofs in a cost-effective, airtight, and moisture-safe manner opens up options for high-performance house designers and builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HPC4Mobilty w/ UCB

The purpose of this project is to examine the energy impact of urban-scale traffic for the Los Angeles Basin by developing and implementing a scalable traffic assignment model. An energy optimization function will be posed and when integrated into the optimization code for travel assignment it can be mathematically proven to converge. The energy optimization function can then be compared to the typical travel time optimization that is traditionally used in traffic assignment models. The analysis will begin with static traffic assignment models with the routing for all origin and destinations computed in parallel on high performance computing facilities. Convergence of the numerical methods rely on the solution of convex programs (or extensions of these). This step will mostly consist of demonstrating the ability to parallelize the Frank Wolfe algorithm on various platforms. This work will contribute to LBNL’s efforts to develop new processes, analytical tools, program designs, and business models to advance the state of the art in next-generation sustainable transportation solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Density drop at the divertor target in the prototype material plasma exposure eXperiment (Proto-MPEX)

The steady-state linear device “Material Plasma Exposure eXperiment” (MPEX) is currently under construction at Oak Ridge National Laboratory with the goal of enabling Plasma-Material Interaction studies at future fusion reactor relevant plasma conditions. In this work, a newly in-house developed hybrid Particle-In-Cell code-PICOS++ is applied to understand the experimental results obtained from the prototype of MPEX referred to as the “Proto-MPEX” during its helicon-only and helicon with ion cyclotron resonance heating (ICRH) experiments. This study explains the physics of the experimentally observed plasma density-drop at the divertor target in Proto-MPEX device during ICRH. In contrast to previous work on ICRH in MPEX, this study demonstrates that the mirror force plays a central role in the Proto-MPEX plasma transport during ICRH, which has new features not previously explored. Force balance analyses reveal that the temperature anisotropy produced by ICRH leads to a significant increase in the mirror force downstream of the resonance where the magnetic field is diverging. This force accelerates ions toward the target and leads to a drop in plasma density to ensure conservation of particle flux. Simulations with ICRH where the magnetic field divergence downstream of the resonance has been removed, do not produce plasma acceleration nor density drop at the target despite efficient ion heating at the resonance. Moreover, simulation results demonstrate that for a given ICRH power, lowering the source rate produces ions with increased perpendicular energy which interact with the mirror force to produce higher plasma acceleration which increases the strength of the density-drop at the target. The strength of the density drop appears to reach an asymptotic limit at a certain threshold ICRH power. Simulations show that this threshold power increases with increasing particle source rate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Leveraging NREL's ResStock & ComStock Dataset to Evaluate Building Stock Electrification: Preprint

Residential and commercial buildings accounted for 40% of U.S. energy consumption in 2022 and represent a significant opportunity for decarbonization through energy efficiency and electrification, and for grid planning. Building stock energy modeling is a powerful tool that can evaluate what-if scenarios as utilities, municipalities, policymakers, building owners and others work towards equitable building decarbonization and climate goals. This presentation will highlight several high-impact use cases of the National Renewable Energy Laboratory (NREL)'s highly granular, bottom-up building stock energy modeling tools, ResStock and ComStock. These use cases cover a wide range of project scale, from neighborhood electrification analysis and municipality long-term energy planning, to state energy code development and national policy evaluation. This presentation will showcase specific real-world applications for which ResStock and ComStock have been utilized across the country, including California codes and standards cost-effectiveness analysis, New York City affordable housing electrification cost gap analysis, and California targeted electrification and gas decommissioning analysis. For each use case, this presentation will illustrate how ResStock and ComStock played a crucial role in accurately characterizing regional building stocks, providing discrete and aggregated end-use load shapes, and calculating lifecycle consumption, emissions, and costs for a variety of building electrification strategies and scenarios. Finally, this presentation will demonstrate how the data provided by ResStock and ComStock can help unlock significant outcomes for these use cases, including but not limited to, customer bill impact, incentive and program design, and energy equity analyses.

building stock modeling↗

A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock: Preprint

Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper will describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.

building stock↗

Organizational and psychological measures for data center energy efficiency: barriers and mitigation strategies

Abstract It was last estimated that in 2020, data centers comprised approximately 2% of total US electricity consumption, with an estimated annual growth rate of 4%. As our country increasingly relies on information technology (IT), our data centers (DCs) will need to increase their energy efficiency (EE) to stabilize their energy consumption. The task of studying EE in DCs is complicated by the interconnected nature of humans and mission-critical technical systems. Moreover, the literature tends to focus on technology solutions such as improvements to IT equipment, cooling infrastructure, and software, without addressing organizational and psychological drivers. Our research demystifies the complex interactions between humans and DCs, by asking What non-technical barriers impede EE investment decision-making and/or implementing energy management strategies? To begin to answer this question, we perform a literature review of 86 resources, ranging from peer-reviewed journal publications to handbooks. We also consider related fields such as organizational behavioral management and energy intensive buildings. We develop a public Zotero library, perform content coding, and complete a rudimentary network analysis. Our findings from the literature review suggest that (1) technological solutions are abundant in the literature but fall short of providing practical guidance on the pitfalls of implementation, (2) making energy efficiency a priority at the executive level of organizations will be largely ineffective if the IT and facilities staff are not directly incentivized to increase EE, and (3) there is minimal current understanding of how the individual psychologies of IT and facilities staff affect EE implementation in DCs. In the next phase of our research, we plan to interview data center operators/experts to ground-truth our literature findings and collaboratively design decarbonization policy solutions that target organizational structure, empower individual staff, and foster a supportive external market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY20 Verification of BISON Using Analytic and Manufactured Solutions

In 2010, the U.S. Department of Energy created its first Energy Innovation Hub, which is focused on developing high-fidelity and high-resolution Modeling and Simulation (M&S) tools for modeling of Light Water Reactors (LWRs). This hub, Consortium for Advanced Simulation of LWRs (CASL), has developed an LWR simulation tool called Virtual Environment for Reactor Applications (VERA). The multi-physics capability of VERA is achieved through the coupling of single-physics codes, including BISON, CTF, MPACT, and MAMBA. BISON is a fuel performance code which models the thermo-mechanical behavior of nuclear fuel using high performance M&S. It is capable of modeling traditional LWR fuel rods, fuel plates, and TRi-structural ISOtropic (TRISO) fuel particles. It can employ three-dimensional Cartesian, two-dimensional axisymmetric cylindrical, or one-dimensional radial spherical geometry. It includes empirical models for a large variety of fuel physics: temperature- and burnup-dependent thermal properties, fuel swelling and densification, fission gas production, cladding creep, fracture, cladding plasticity, and gap/plenum models. This document details a series of code verification test problems that are used to test BISON. These problems add confidence that the BISON code is a faithful representation of its underlying mathematical model. The suite of verification tests are mapped to the underlying conservation equations solved by the code: heat conduction, mechanics, and species conservation. Twenty-two problems are added for the heat conduction solution, two for the mechanics solution, and none for species conservation. Method of Manufactured Solutions (MMS) capability is demonstrated with three problems, and temperature drops across the fuel gap are tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancements in Multiphysics Microdepletion Analysis of an eVinci TM -like Microreactor Leveraging OpenMC-CRAB Workflow

Nuclear microreactors (MRs) are a class of nuclear reactor technology, characterized by reduced dimensions, modular design, and reduced power output in contrast to conventional Light Water Reactors (LWRs). MRs are proposed for supplying electricity and eventual process heat to remote locations, such as military installations and disaster-affected areas. Current research work sponsored by the US Department of Energy Microreactor Program (MRP) is devoted to the development of novel modeling and simulation tools to better support MR vendors and regulatory bodies. Notably, the NRC is projected to utilize the CRAB multiphysics software driver for executing both design and beyond-design-basis accident analyses. Furthermore, the NRC has been utilizing the MELCOR code to calculate mechanistic source terms during accidents. Since MELCOR relies on isotopic inventory and reactor temperature/power profiles under accident conditions, which theoretically can be derived from CRAB, the goal is to establish a comprehensive CRAB-MELCOR computational framework. Past work was focused on testing and demonstrating CRAB's capability to generate results that can be used to inform mechanistic source term calculations in MELCOR. In particular, a computational workflow leveraging OpenMC-generated microscopic cross sections and CRAB was first applied to perform multiphysics microscopic depletion calculation followed by an accident scenario for a stylized microreactor problem. In fiscal year 2024, the research work has been focused on applying the OpenMC-CRAB workflow, which was first tested in fiscal year 2023, to a realistic 3D heat-pipe cooled MR problem representative of the eVinci TM design. The latter computational problem was developed with inputs from WEC to conserve selected neutronic and thermal characteristics of the eVinci TM design without releasing proprietary data. The results of this simulation, encompassing isotopic inventory, power density distribution, and kinetic parameters, will inform both MELCOR and the WEC-developed FATE code for mechanistic source terms calculations. The results from the two codes will then be compared for code verification purposes. This report contains the design characteristics of the realist heat pipe cooled microreactor developed as a use-case for the verification exercise, and the current results for the multiphysics microscopic depletion performed with the OpenMC-CRAB workflow. The results include eigenvalue as a function of time, power distribution at EOL, in addition to nuclides inventory's time evolution and spatial distribution. Finally, we report improvements to the workflow efficiency achieved through a collaboration with the NEAMS programs. Through this collaborative effort, we were able to strongly decrease the computational time for the multiphysics microdepletion calculation (i.e., from 17.4 hours to 5.7 hours on 280 processors) in addition to simplifying the interface to generate isotopics spatial distribution utilizable by FATE and MELCOR. Future work, including the improvement of the current microscopic cross-sections' library and the simulation of an accident scenario at EOL, is also discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving Residential Building Simulations Through Large-Scale Empirical Validation

Residential building energy simulations are increasingly used for energy-efficient building design, codes and standards analysis, home certifications and ratings, utility programs, and technology assessments. Various software tools exist to perform residential building simulations, and these tools often use different models, inputs, and assumptions. This leads to inconsistencies that can undermine confidence in the predicted results. Validation of these tools can increase confidence by ensuring their accuracy and consistency. One way to validate simulation tools is through empirical testing, which compares predicted energy usage to measured utility billing data. This paper describes the process of data collection, data standardization, and empirical validation, and illustrates its use with our residential EnergyPlus (R)-based software. The data and process can be extended to other simulation tools and contribute to improving residential building simulations more broadly.

empirical validation↗

Investigating Response from Attached and Separated Flow Excitations on a Real Launch Vehicle using SEA

Statistical Energy Analysis (SEA) response has been fairly well anchored to test observations for Diffuse Acoustic Field (DAF) loading by others. Meanwhile, not many examples can be found in the literature anchoring the SEA vehicle panel response results to Turbulent Boundary Layer (TBL) fluctuating pressure excitations. This deficiency is especially true for supersonic trajectories such as those required by this nation s launch vehicles. Response and excitation data from vehicle flight measurements gathered during the development flight era of the Space Shuttle have been used in a trial to assess the sensitivity of response analysis to certain known and unknown parameters of the flight. This assessment compares vibration response predictions for TBL excitations produced by the SEA tool to flight measurements. A secondary, but perhaps more important objective, is to provide more clarity concerning the accuracy and conservatism that can be expected from response estimates to TBL-excited vehicle models in SEA. What range of parameters must be included in such an analysis in order to land on the conservative side in response predictions? What is the variability produced in the results with changes in these parameters? The TBL fluid structure loading model used for this study is provided from the SEA module of the commercial code VA One.

Harrison, Phil↗

Measured Moisture Performance of Sealed and Insulated Attics with Permeable Insulation In California Homes

This study performed detailed thermal and moisture measurements in two homes in Fresno and Clovis, California with sealed attics insulated with glass fiber insulation to determine moisture performance in inland California climates. Data were recorded once every minute for more than a year in each home to allow detailed observation of time-varying moisture and thermal conditions. Moisture measurements were taken at multiple locations in each attic and included wood moisture, surface condensation and surface relative humidity. The results showed that there are strong solar-driven diurnal cycles in attic wood and air moisture content, as well as longer-term seasonal and annual variations. Mold growth was obdserved on the North roof deck in one of the two homes even in this sunny dry climate with attics built in compliance with California building codes that specifically address sealed and insulated attics with vapor-permeable insulation. We investigated moisture stratification in the attic and found that, although there is stratification during sunny daytime hours, this was not when wood moisture content, surface humidity or surface condensation are high. Therefore, other moisture transport mechanisms are acting to increase moisture levels near the roof peak. Finally, our measurements also showed that the attic with the highest measured moisture levels did not have any mold growth, while mold was visually observed in the attic whose measurements indicted little or no concern, indicating that the state-of-the-art in moisture measurement and mold growth prediction in building assemblies may be insufficient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Advanced Smart Ventilation Controls for Residential Applications

This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model for new California dwellings. Several smart control strategies were developed with a target of halving ventilation-related energy use, largely through reducing dwelling ventilation rates based on zone occupancy. The controls were evaluated based on the annual energy consumption relative to continuously operating non-zoned, code-compliant mechanical ventilation systems. The systems were also evaluated from an indoor air quality perspective using the equivalency approach, where the annual personal concentration of a contaminant for a control strategy is compared to the personal concentration that would have occurred using a continuously operating, non-zoned system. Individual occupant personal concentrations were calculated for the following contaminants of concern: moisture, CO2, particles, and a generic contaminant. Zonal controls that saved energy by reducing outside airflow achieved typical reductions in ventilation-related energy of 10% to 30%, compared to the 7% savings from the unzoned control. However, this was at the expense of increased personal concentrations for some contaminants in most cases. In addition, care is required in the design and evaluation of zonal controls, because control strategies may reduce exposure to some contaminants, while increasing exposure to others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Perturbative model for the saturation of energetic-particle-driven modes limited by self-generated zonal modes

We present a simplified energy-conserving approach to incorporate wave–wave nonlinear effects within the framework commonly used to describe wave–particle nonlinearities. In particular, the effects of zonal mode (ZM) generation on the determination of the saturation amplitude of energetic particle (EP)-driven Alfvénic instabilities is studied. The model assumes that the zonal perturbations grow at a rate twice that of the original (pump) wave, consistent with a beat-driven (or force-driven) generation mechanism. The evolution and saturation of the mode amplitude are investigated both analytically and numerically within our reduced model assumptions, in both the collisionless and scattering-dominated regimes. These studies underscore the crucial role of sources and sinks in capturing the impact and the role of beat-driven zonal perturbations on mode evolution. In the realistic case of saturation set by sources and sinks, we discuss the role of a finite amplitude ZM in reducing microturbulent particle scattering, thus limiting the energy source for the resonant mode. We then discuss comparisons between the model’s predictions and simulation results. The model reproduces key features observed in gyrokinetic simulations as the reduction in saturated mode amplitude and the onset of wave–wave nonlinear effects as functions of mode growth rate and amplitude. Thanks to its simplicity, it can be readily implemented into codes based on reduced models, thereby improving their predictive capability for strongly driven instabilities.

Alfvén eigenmodes↗

Investigating Response from Turbulent Boundary Layer Excitations on a Real Launch Vehicle using SEA

Statistical Energy Analysis (SEA) response has been fairly well anchored to test observations for Diffuse Acoustic Field (DAF) loading by others. Meanwhile, not many examples can be found in the literature anchoring the SEA vehicle panel response results to Turbulent Boundary Layer (TBL) fluctuating pressure excitations. This deficiency is especially true for supersonic trajectories such as those required by this nation s launch vehicles. Space Shuttle response and excitation data recorded from vehicle flight measurements during the development flights were used in a trial to assess the capability of the SEA tool to predict similar responses. Various known/measured inputs were used. These were supplemented with a range of assumed values in order to cover unknown parameters of the flight. This comparison is presented as "Part A" of the study. A secondary, but perhaps more important, objective is to provide more clarity concerning the accuracy and conservatism that can be expected from response estimates of TBL-excited vehicle models in SEA (Part B). What range of parameters must be included in such an analysis in order to land on the conservative side in response predictions? What is the sensitivity of changes in these input parameters on the results? The TBL fluid structure loading model used for this study is provided by the SEA module of the commercial code VA One.

Harrison, Phillip↗