Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emission spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Slater transition methods for core-level electron binding energies

Methods for computing core-level ionization energies using self-consistent field (SCF) calculations are evaluated and benchmarked. These include a “full core hole” (or “ΔSCF”) approach that fully accounts for orbital relaxation upon ionization, but also methods based on Slater’s transition concept in which the binding energy is estimated from an orbital energy level that is obtained from a fractional-occupancy SCF calculation. A generalization that uses two different fractional-occupancy SCF calculations is also considered. The best of the Slater-type methods afford mean errors of 0.3–0.4 eV with respect to experiment for a dataset of K-shell ionization energies, a level of accuracy that is competitive with more expensive many-body techniques. An empirical shifting procedure with one adjustable parameter reduces the average error below 0.2 eV. Here, this shifted Slater transition method is a simple and practical way to compute core-level binding energies using only initial-state Kohn–Sham eigenvalues. It requires no more computational effort than ΔSCF and may be especially useful for simulating transient x-ray experiments where core-level spectroscopy is used to probe an excited electronic state, for which the ΔSCF approach requires a tedious state-by-state calculation of the spectrum. As an example, we use Slater-type methods to model x-ray emission spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kβ X-ray Emission Spectra Analysis Using Bayesian Optimization

The Kβ X-ray emission spectrum of 3 d transition metals is rich with electronic and structural information due to strong exchange interactions with the valence shell of the metal, and has become crucial for understanding their spin and oxidation states. The spectrum is commonly treated using crystal-field multiplet theory, a semi-empirical theory that uses tunable parameters to control the strength of the effects present in X-ray emission spectroscopy (XES). However, determining the experimental values of these parameters remains a challenge. We present a methodology that applies Bayesian optimization to crystal-field multiplet theory to determine parameter values. The algorithm is tested on the X-ray emission spectra of a collection of Mn, Co, and Ni oxides. We are able to find optimal values for the four most impactful parameters: Slater−Condon reduction factors F dd , F pd , and G pd , and crystal field splitting 10 Dq . The algorithm produces significantly improved accuracy compared to current analysis methods, and probes interparameter dependencies by modeling the error landscape. This advancement enhances XES analysis by offering an approach of obtaining quantitative electronic structural information on 3 d transition metal valence shells, facilitating applications across various scientific fields.

Bayesian optimization↗

An excited state dynamics driven reaction: wavelength-dependent photoisomerization quantum yields in [Ru(bpy) 2 (dmso) 2 ] 2+

We report the excited-state behavior of a structurally simple bis -sulfoxide complex, cis -S,S-[Ru(bpy) 2 (dmso) 2 ] 2+ , as investigated by femtosecond pump–probe spectroscopy. The results reveal that a single photon prompts phototriggered isomerization of one or both dmso ligands to yield a mixture of cis -S,O-[Ru(bpy) 2 (dmso) 2 ] 2+ and cis -O,O-[Ru(bpy) 2 (dmso) 2 ] 2+ . The quantum yields of isomerization of each product and relative product distribution are dependent upon the excitation wavelength, with longer wavelengths favoring the double isomerization product, cis -O,O-[Ru(bpy) 2 (dmso) 2 ] 2+ . Transient absorption measurements on cis -O,O-[Ru(bpy) 2 (dmso) 2 ] 2+ do not reveal an excited-state isomerization pathway to produce either the S,O or S,S isomers. Femtosecond pulse shaping experiments reveal no change in the product distribution. Pump–repump–probe transient absorption spectroscopy of cis -S,S-[Ru(bpy) 2 (dmso) 2 ] 2+ shows that a pump–repump time delay of 3 ps dramatically alters the S,O:O,O product ratio; pump–repump–probe transient absorption spectroscopy of cis -O,O-[Ru(bpy) 2 (dmso) 2 ] 2+ with a time delay of 3 ps uncovers an excited-state isomerization pathway to produce the S,O isomer. In conjunction with low-temperature steady-state emission spectroscopy, these results are interpreted in the context of an excited-state bifurcating pathway, in which the isomerization product distribution is determined not by thermodynamics, but rather as a dynamics driven reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Spectroscopy Characterization of Electronic Structure and Metal–Metal Bonding in Dicobalt Complexes

Developing multimetallic complexes with tunable metal–metal interactions has long been a target of synthetic inorganic chemistry efforts due to the unique properties that such compounds can exhibit. However, understanding relationships between metal–metal bonding and chemical properties is challenging due to system-dependent factors that influence metal–metal and metal–ligand interactions, including ligand identity, coordination geometry, and metal–metal distance. In this work, we apply X-ray absorption and emission spectroscopy and quantum chemical calculations to describe electronic structure and bonding in a series of dicobalt complexes. The compounds with silane ligands and pseudo-octahedral coordination geometry exhibit Co–Co σ and multicentered bonding character, which we characterize from both the occupied and vacant perspectives via their contributions to the Co X-ray emission and absorption spectra, respectively. In contrast, the dicobalt complexes with a pseudotetrahedral coordination environment do not exhibit Co–Co bonding due to symmetry constraints on orbital overlap. We extend these insights to the theoretical evaluation of related dicobalt complexes to explain how ligand coordination and symmetry dictate the presence or absence of a Co–Co bond. In conclusion, this work highlights how fundamental insights into electronic structure and bonding through X-ray spectroscopy uncover important factors governing metal–metal interactions and guide the rational design of multimetallic complexes with tunable metal–metal bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Colossal Terahertz Emission with Ultrafast Tunability Based on Van der Waals Ferroelectric NbOI 2

Abstract Terahertz (THz) technology is critical for quantum material physics, biomedical imaging, ultrafast electronics, and next‐generation wireless communications. However, standing in the way of widespread applications is the scarcity of efficient ultrafast THz sources with on‐demand fast modulation and easy on‐chip integration capability. Here the discovery of colossal THz emission is reported from a van der Waals (vdW) ferroelectric semiconductor NbOI 2 . Using THz emission spectroscopy, a THz generation efficiency an order of magnitude higher than that of ZnTe, a standard nonlinear crystal for ultrafast THz generation is observed. The underlying generation mechanisms associated are further uncovered with its large ferroelectric polarization by studying the THz emission dependence on excitation wavelength, incident polarization, and fluence. Moreover, the ultrafast coherent amplification and annihilation of the THz emission and associated coherent phonon oscillations by employing a double‐pump scheme are demonstrated. These findings combined with first‐principles calculations, inform a new understanding of the THz light–matter interaction in emergent vdW ferroelectrics and pave the way to develop high‐performance THz devices on them for quantum materials sensing and ultrafast electronics.

Subedi, Sujan [Department of Materials Science and↗

X-ray Spectroscopic Studies of a Solid-Density Germanium Plasma Created by a Free Electron Laser

The generation of solid-density plasmas in a controlled manner using an X-ray free electron laser (XFEL) has opened up the possibility of diagnosing the atomic properties of hot, strongly coupled systems in novel ways. Previous work has concentrated on K-shell emission spectroscopy of low Z (<= 14) elements. Here, we extend these studies to the mid-Z(=32) element Germanium, where the XFEL creates copious L-shell holes, and the plasma conditions are interrogated by recording of the associated L-shell X-ray emission spectra. Given the desirability of generating as uniform a plasma as possible, we present here a study of the effects of the FEL photon energy on the temperatures and electron densities created, and their uniformity in the FEL beam propagation direction. We show that good uniformity can be achieved by tuning the photon energy of the XFEL such that it does not overlap significantly with L-shell to M-shell bound-bound transitions, and lies below the L-edges of the ions formed during the heating process. Reasonable agreement between experiment and simulations is found for the emitted X-ray spectra, demonstrating that for these higher Z elements, the selection of appropriate XFEL parameters is important for achieving uniformity in the plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laer-induced Breakdown Spectroscopy Instrument for Element Analysis of Planetary Surfaces

One of the most fundamental pieces of information about any planetary body is the elemental and mineralogical composition of its surface materials. We are developing an instrument to obtain such data at ranges of up to several hundreds of meters using the technique of Laser-Induced Breakdown Spectroscopy (LIBS). We envision our instrument being used from a spacecraft in close rendezvous with small bodies such as comets and asteroids, or deployed on surface-rover vehicles on large bodies such as Mars and the Moon. The elemental analysis is based on atomic emission spectroscopy of a laser-induced plasma or spark. A pulsed, diode pumped Nd:YAG laser of several hundred millijoules optical energy is used to vaporize and electronically excite the constituent elements of a rock surface remotely located from the laser. Light emitted from the excited plasma is collected and introduced to the entrance slit of a small grating spectrometer. The spectrally dispersed spark light is detected with either a linear photo diode array or area CCD array. When the latter detector is used, the optical and spectrometer components of the LIBS instrument can also be used in a passive imaging mode to collect and integrate reflected sunlight from the same rock surface. Absorption spectral analysis of this reflected light gives mineralogical information that provides a remote geochemical characterization of the rock surface. We performed laboratory calibrations in air and in vacuum on standard rock powders to quantify the LIBS analysis. We performed preliminary field tests using commercially available components to demonstrate remote LIBS analysis of terrestrial rock surfaces at ranges of over 25 m, and we have demonstrated compatibility with a six-wheeled Russian robotic rover vehicle. Based on these results, we believe that all major and most minor elements expected on planetary surfaces can be measured with absolute accuracy of 10-15 percent and much higher relative accuracy. We have performed preliminary systems analysis of a LIBS instrument to evaluate probable mass and power requirements; results of this analysis are summarized.

Blacic, J.↗

Gas-phase oxidation and nanoparticle formation in multi-element laser ablation plumes

The evolution from gas-phase oxidation to nanoparticle and agglomerate formation was studied in nanosecond laser-produced plasmas of a multi-principal element alloy target in air. Here gas-phase oxidation of plasma species was monitored in situ via optical emission spectroscopy, while a custom-built single particle mass spectrometer was used to measure size and compositions of agglomerated nanoparticles formed in laser ablation plumes. Ex situ analysis employing transmission electron microscopy was used to study nanoparticle morphology, crystal structure, and element distribution at the nanoscale. Emission spectra indicate that gas-phase oxidation of elements in the alloy target are formed at varying times during plume evolution, and mass spectrometry results indicate fractal agglomerates contain all principal alloying elements and their oxides. Finally, electron microscopy characterization illustrates that these agglomerates consist of multiple material types: sub-10 nm diameter amorphous, multi-element nanoparticles, ≈10–30 nm diameter Ti-rich crystalline oxide nanoparticles, and ejected base material. Results highlight that the multi-component target composition impacts molecular formation in the gas phase and the morphology, composition, and structure of nanoparticles and agglomerates formed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical emission diagnostics of electron cyclotron resonance and glow discharge plasmas for a-Si:H and a-SiC:H film depositions

It is demonstrated that the steady-state and kinetic characteristics of ECR (electron cyclotron resonance) and RF glow discharge plasmas can be readily monitored by OES (optical emission spectroscopy) in real time during a-Si:H and a-SiC:H film depositions using an OMA detection system. The ECR and RF glow discharge plasmas used for a-Si:H and a-SiC:H film depositions were studied by monitoring the emission of SiH(asterisk), H(asterisk), H(asterisk)2, and CH(asterisk) excited states. The OES of the ECR plasma shows a strong emission at 434 nm from H(asterisk), which is not detectable in the glow discharge plasma. Steady-state OES studies have established preliminary correlations between SiH(asterisk) and CH(asterisk) emission intensities and the film deposition rate. Transient OES spectra of SiH4 and CH4 plasmas have shown different kinetics in SiH(asterisk) and CH(asterisk) emission intensities. Transient studies of the SiH(asterisk) emission intensity have indicated that additional mechanisms for producing the SiH(asterisk) species become evident in hydrogen-diluted silane plasmas.

Yang, C. L.↗

An expert system for spectroscopic analysis of rocket engine plumes

The expert system described in this paper analyzes spectral emissions of rocket engine exhaust plumes and shows major promise for use in engine health diagnostics. Plume emission spectroscopy is an important tool for diagnosing engine anomalies, but it is time-consuming and requires highly skilled personnel. The expert system was created to alleviate such problems. The system accepts a spectral plot in the form of wavelength vs intensity pairs and finds the emission peaks in the spectrum, lists the elemental emitters present in the data and deduces the emitter that produced each peak. The system consists of a conventional language component and a commercially available inference engine that runs on an Apple Macintosh computer. The expert system has undergone limited preliminary testing. It detects elements well and significantly decreases analysis time.

Reese, Greg↗

Remote Recession Measurements of Wire-Seeded PICA Samples in an Arc-Jet Flow

Various methods for remote recession sensing of PICA have been developed and several seeding methods have been tested. The most recent method involved seeding the ablator with wires fed to the sample from the backside with a defined amount of PICA left towards the upstream front of the sample. This seed method mimics the installation of in-depth thermocouples as they are frequently used in ground testing and flight. Arc-jet tests were conducted in the NASA Langley HYMETS facility at a heat flux of 320 W/sq.cm. The emission of the post-shock layer was observed in spectral resolution from the side along an optical axis perpendicular to the arc-jet flow and from the front, looking at the sample surface from an upstream position. Various metallic seed materials with different melting points were used. In addition to the emission spectroscopy measurements, the samples were monitored during the tests through pyrometry and videography. The time resolved response of the seeded material is described and compared to earlier tests with different seeding methods. The combination of seed materials was found to be critical for the selection of emission signatures characteristic for the material recession which can be isolated in the final emission spectra.

Winter, Michael↗

Giant room-temperature nonlinearities in a monolayer Janus topological semiconductor

Abstract Nonlinear optical materials possess wide applications, ranging from terahertz and mid-infrared detection to energy harvesting. Recently, the correlations between nonlinear optical responses and certain topological properties, such as the Berry curvature and the quantum metric tensor, have attracted considerable interest. Here, we report giant room-temperature nonlinearities in non-centrosymmetric two-dimensional topological materials—the Janus transition metal dichalcogenides in the 1 T’ phase, synthesized by an advanced atomic-layer substitution method. High harmonic generation, terahertz emission spectroscopy, and second harmonic generation measurements consistently show orders-of-the-magnitude enhancement in terahertz-frequency nonlinearities in 1 T’ MoSSe (e.g., > 50 times higher than 2 H MoS 2 for 18 th order harmonic generation; > 20 times higher than 2 H MoS 2 for terahertz emission). We link this giant nonlinear optical response to topological band mixing and strong inversion symmetry breaking due to the Janus structure. Our work defines general protocols for designing materials with large nonlinearities and heralds the applications of topological materials in optoelectronics down to the monolayer limit.

42 ENGINEERING↗

Trap-assisted Auger-Meitner recombination in GaN p-i-n diodes

Most properties of semiconductor devices are dominated by shallow impurities. However, deep defects often play an important role, for instance, in recombination processes or high field transport. While a variety of techniques are available to assess the density and energy levels of impurities, other properties, such as the recombination mechanisms of the defects, escape observation. We report on the direct measurement of hot electrons generated by trap-assisted Auger-Meitner recombination (TAAR) in GaN p-i-n diodes. By performing electron emission spectroscopy (EES) on diodes with surfaces activated to negative electron affinity by cesium, we observe the expected overflow electrons of p-i-n diodes under low current injection. However, when operating the devices at higher current densities, as low as ∼25 A/c⁢m 2 , we measure the emission of high-energy electrons. At variance with the observed hot electrons in light-emitting diodes (LEDs) using EES, the hot electrons generated in p-i-n diodes at our tested currents cannot be from eeh Auger-Meitner recombination due to the diodes' significantly lower carrier densities compared to those in LEDs. During our measurements, we observe the emission of accumulated electrons with energies ∼0.42 eV, ∼0.99 eV, ∼1.43 eV, and ∼2.32 eV above the conduction-band minimum (CBM) at various bias conditions, suggesting the existence of conduction-band features in GaN at these energies where electrons can be long-lived, such as satellite-valley minima and inflection points. We also measure incompletely relaxed hot electrons approaching energies 1.97 ± 0.13 eV and 2.94 ± 0.13 eV above the CBM, as the diodes are biased to high currents, suggesting at least some of the TAAR partaking defects have an energy level ≳1.97 eV and ≳2.94 eV away from either the conduction or valence band edges. Additionally, at our highest operating currents, we measure hot electrons with energies 3.28 ± 0.13 eV above the CBM, providing direct evidence of TAAR processes involving shallow impurities. This unexpected observation of TAAR in GaN p-i-n diodes spotlights the importance of further studies of defects in GaN and the necessity to incorporate the multi-phonon emission, radiative, and TAAR capture steps of defect-assisted recombination cycles into device modeling. Furthermore, this experiment demonstrates the applicability of the simplest semiconductor structures, p-i-n diodes, as a test bed to study the rich recombination physics of semiconductor materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of a laser for the spectral analysis of semiconductor materials

Conventional applications of lasers for emission spectroscopy involving direct recording of light pulses of an evaporated substance emitted from the sample under the action of the laser light (direct method) were examined. Use of the laser light for conversion of the substance to a vapor and feeding the vapors into the conventional source of emission such as arc, sparks, etc. (the so called 2 stage excitation) were studied for use in the spectral analysis, of semiconductors. The direct method has a high reproducibility (5-7%); the 2 stage excitation method, characterized by the same intensity as obtained with the conventional constant, current arc, has better reproducibility than the direct method (15-20%). Both methods can be used for the analysis of samples without prior preparation. Advantages of these methods are the elimination of impurities picked up during trituration of the samples into powders and shortening of the analytical procedures.

Karyakin, A. V.↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Thermal Infrared Spectroscopy from Mars Landers and Rovers: A New Angle on Remote Sensing

The MINUTES instrument of the Athena Precursor Experiment (APEX) on the Mars Surveyor 2001 lander mission will perform the first thermal infrared remote sensing observations from the surface of another planet. Experience gained from this experiment will be used to guide observations from identical instruments mounted on the Athena rovers, to be launched in 2003 and 2005. The utility of infrared spectrometers in determining the mineralogic composition of geologic surfaces from airborne and spaceborne platforms has been amply demonstrated. However, relatively little experience exists in using functionally similar instruments on the ground in the context of planetary science. What work has been done on this problem has mostly utilized field spectrometers that are designed to look down on nearby target rocks. While many Mini-TES observations will be made with this type of geometry, it is likely that other observations will be made looking horizontally at the more vertically-oriented facets of rock targets, to avoid spectral contamination from dust mantles. On rover missions, the Mini-TES may also be pointed horizontally at rocks several meters away, to determine if they are worthy of approaching for in situ observations and possible sample cacheing. While these observations will undoubtedly prove useful, there are important, and perhaps unappreciated, differences between horizontal-viewing, surface-based spectroscopy and the more traditional nadir-viewing, orbit or aircraft-based observations. Plans also exist to step the Mini-TES in a rastering motion to build hyperspectral scenes. Horizontal viewing hyperspectral cubes also possess unique qualities that call for innovative analysis techniques. The effect of viewing geometry: In thermal emission spectroscopy, regardless of whether an instrument is looking down on or horizontally at a target, the same basic equation governs the radiance reaching the sensor .

Moersch, J.↗

Characterization of CO 4th Positive Radiation in CO2-Ar Mixtures

This paper presents measurements and simulations of CO 4th Positive spectra obtained in NASA Ames Research Center's Electric Arc Shock Tube (EAST) and CentraleSupelec's Plasma Torch. The experiments were aimed at measuring optically thin emission for the main band features of CO 4th Positive by using test gas mixtures of CO2 and Ar. By using mixtures of CO2 and Ar, the temperature of the flow (and consequently black-body curve) is increased compared to using pure CO2 (or CO2 / N2 mixtures). This temperature increase allows for emission spectroscopy of features that would nominally be black-body limited for conditions relevant to Mars entry. The CO 4th Positive system is the focus of this study as it accounts for a large percentage of the emitted radiation for Martian entry, and also due to the difficulties of obtaining experimental validation data due to the emission appearing in the Vacuum Ultraviolet (VUV) spectral range. The focus of this paper is to provide a comprehensive comparison between the EAST and plasma torch data along with various CO 4th Positive databases available in the literature. Previously reported VUV CO2 / N2 EAST data required a larger temperature than would be predicted based upon equilibrium shock relations. The need for the temperature increase implies that the EAST experiment did not fully equilibrate. Thus, it is presumed that the EAST data did not obtain an equilibrium condition. The plasma torch data, on the other hand, is very consistent with equilibrium assumptions. Thus, the equilibrium data obtained in the plasma torch is utilized to construct the CO 4th Positive emission model, which is then applied to the EAST data with a non-equilibrium interpretation.

A. M. Brandis↗

(abstract) Mars Global Surveyor: A Global Mapping Mission

The Mars Global Surveyor Mission will launch a single spacecraft to Mars in November 1996. After arrival at the planet in September 1997 aerobraking will be used to lower the spacecraft into a low, sun-synchronous, polar-mapping orbit over several months. Early in 1998 mapping observations will begin and continue for a Mars year (687 days). Following completion of this first Mars year of mapping the spacecraft will continue to act as a relay orbiter for an additional three Earth years. The five instruments carried involve magnetometry, surface and atmosphere imaging, atmospheric sounding, laser altimetry, gravity and thermal emission spectroscopy. In addition, the spacecraft carries a Mars relay receiver/transmitter which will operate over the entire five year orbital mission ending in January of 2003. The Mars Global Surveyor mission is intended to accomplish a portion of the scientific objectives of the Mars Observer mission which was lost in 1993 three days before entering Mars orbit. The instrumentation to be used for the magnetometers, cameras, laser altimeter, emission spectrometer and radio science are very nearly the same as those carried by Mars Observer. The spacecraft design will be new but will use spare equipment from Mars Observer and has a mass about two and one-half time smaller. All experiments will be controlled remotely from their investigators home installation. The long planned period of observation supports the mission's global and seasonal objectives.

Mars Global Surveyor Mars Observer mapping spectro↗