High data rate performance of a BCCD for rapid scan imaging

A commercially available 1728 element shallow bulk channel CCD line array was clocked at output data rates up to 30 MHz. Temporal noise was near 200 electrons and was largely independent of clock rate. Charge transfer efficiency was in excess of 0.9999 at 30 MHz. Utilization is feasible for visual simulation and aerial mapping.

Schmieder, D. E.↗

Natural precedents to active magnetospheric experiments

Some of the natural analogs of proposed seeding experiments in the magnetosphere are: electric charged particle injections during substorms; lightning-induced whistlers providing wave injections; 'detachment' of plasma from the plasmapause, which is equivalent to light-ion seeding in the outer magnetosphere. In the present paper, the characteristics of some natural precedents to active experiments are reviewed, and their relative advantages and drawbacks are examined. One of these precedents - wave generation in detached plasma regions - is then discussed in some detail; the discussion reveals the generation of ELF electromagnetic noise when the energetic electrons exceed the stably trapped limit, and also indicates that a critical dimension for the seeded volume exists transverse to the geomagnetic field.

Russell, C. T.↗

Aeropropulsion in year 2000

The paper demonstrates that many advances can be anticipated in propulsion systems for aircraft in the next 20 years. A survey is presented of probable future engine types, including convertible engines for helicopters, turboprops for fuel efficient airliners, and variable cycle engines for supersonic transports. Also examined is the use of rotary engines in general aviation aircraft. Finally, a review is given of related technology improvements in propellers, materials, noise suppression, and digital electronic controls.

Weber, R. J.↗

The signature of auroral kilometric radiation on Isis 1 ionograms

Auroral kilometric radiation (AKR) appears on the Isis 1 topside sounder ionograms as intense noise bands between the electron cyclotron frequency and 700 kHz. A variable gap occurs between the cyclotron frequency and the lowest AKR frequency. As Isis 1 traverses the source region, the gap narrows, and the AKR signals at higher frequencies weaken. This signature suggests that the AKR waves are generated directly in the extraordinary mode at frequencies just above the local cutoff frequency and that the radiation is initially perpendicular to the magnetic field.

Calvert, W.↗

A CCD System for Photometry of Direct and Spectroscopic Images

A charge-coupled device (CCD) for direct imagery at the focus of a ground-based telescope and for high dispersion spectroscopy of stars is evaluated. The CCD is an RCA SID 53612 thinned, buried channel array of 512x320 30-micron square pixels that are back-illuminated and refrigerated to about -60 C in a rugged, RF-shielded vacuum housing. The double-correlated sampling (integrator) readout system, the Z80 microprocessor readout control system, and the data collection system are described. The readout noise is 120 electron-hole pairs (ehp) per pixel per readout, the thermal dark current is 50 ehp/pixel/sec, and the scale of the 12-bit analog-to-digital converter is 25 ehp/AD unit. Unique features of this system are compared to other astronomical implementations of the same model of CCD.

Frecker, J. E.↗

Charge-coupled device camera for the Galileo Jupiter Orbiter spacecraft

A slow-scan television camera called the solid-state imaging subsystem (SSI), built for the Galileo Jupiter Orbiter, is described. The SSI consists of a 1500-mm focal-length telescope coupled to a camera head housing a 800 x 800-element charge-coupled device (CCD) detector based on 'virtual-phase' charge transfer technology. The CCD detector provides broadband sensitivity over 100 times that of a comparable vidicon-tube camera, while also yielding improved resolution, linearity, geometric fidelity, and spectral range. The system noise floor is 30 electrons, which results in a dynamic range of about 3500. Saturation of the detector with 9000-A light, followed by a high-speed erasure cycle prior to exposing each image, stabilizes the detector quantum efficiency at its maximum level for wavelengths beyond 7000 A. An optical schematic diagram of the SSI is included.

Klaasen, K. P.↗

Plasma waves and instabilities

An account is given of the waves and instabilities occurring at collisionless shocks, with attention to the mechanisms responsible for the generation of these waves. The transition region of the shock usually involves an abrupt broadband burst of electrostatic noise that extends from below the lower hybrid resonance to near the electron plasma frequency, and by a broadband burst of whistler mode EM noise below the electron cyclotron frequency. Electrostatic lower hybrid waves are also noted. Upstream of the shock, electron plasma oscillations, ion acoustic waves, and intense ULF MHD waves are often observed. The region downstream of the shock is usually very chaotic; electrostatic waves often extend long distances into the downstream region, together with whistler mode emissions.

Gurnett, Donald A.↗

Laboratory and telescope use of the NICMOS2 128 x 128 HgCdTe array

The second generation of Hubble Space Telescope (HST) instruments will include a near-infrared instrument. This choice has driven the development of near-infrared arrays to larger sizes and lower read noises. Rockwell International has delivered an array for use in the Near Infrared Camera and Multi-Object Spectrometer (NICMOS) instrument; this array has been dubbed NICMOS2. NICMOS2 is a 128x128 array of HgCdTe diodes In-bonded to a switched MOSFET readout. The readout was specifically designed for astronomical use with the HST requirement of low read noise a prime goal. These arrays use detector material which is similar to that used by Rockwell in previous arrays (e.g., HgCdTe produced on a sapphire substrate), but the NICMOS2 devices differ substantially from other 128x128 arrays produced by Rockwell in having a read noise of only 30 electrons when read out using appropriate correlated sampling. NICMOS2 has now been characterized in the laboratory, and it has been used on groundbased telescopes.

Rieke, Marcia J.↗

Plasma contactor research, 1989

The characteristics of double layers observed by researchers investigating magnetospheric phenomena are contrasted to those observed in plasma contacting experiments. Experiments in the electron collection mode of the plasma contacting process were performed and the results confirm a simple model of this process for current levels ranging to 3 A. Experimental results were also obtained in a study of the process of electron emission from a hollow cathode plasma contactor. High energy ions are observed coming from the cathode in addition to the electrons and a phenomenological model that suggests a mechanism by which this could occur is presented. Experimental results showing the effects of the design parameters of the ambient plasma simulator on the plasma potential, electron temperature, electron density and plasma noise levels induced in plasma contacting experiments are presented. A preferred simulator design is selected on the basis of these results.

Williams, John D.↗

Electro optical system to measure strains at high temperature

The goals of this proposal were to develop a prototype of an electro-optics system for the measurement of strains in structures at high temperatures and to perform a test under field conditions. In the research task section, the topics addressed include: (1) correction of the effect of vibrations and thermal currents by means of an active compensation system; (2) reduction of the speckle noise by means of electronic filter and TV signal reconstruction circuit; (4) compensation of the rigid body motions by mounting the camera in a universal motion system; and (5) removal of phase errors left by the active compensation system by dynamic reading. In the design and construction section, the topics addressed include: (1) preliminary design; (2) final design; (3) software development; (4) signal conditioning; (5) data processing; (6) recorrelation of two holograms in the presence of rigid body motions; and (7) phase extraction using a computer generated image. Testing in the high temperature oven is also addressed.

Sciammarella, Cesar A.↗

Effects of transistor geometry on CCD output sensitivity

This paper discusses recent progress in the understanding of the fabrication of low noise floating diffusion output amplifiers for special purpose charge-coupled devices. Emphasis has been given to reducing the total node capacitance and increasing the output sensitivity. Measurements of noise on experimental devices has yielded noise less than 3 electrons rms at 50 kpixel data rate.

Kim, H.↗

An abuttable CCD imager for visible and X-ray focal plane arrays

A frame-transfer silicon charge-coupled-device (CCD) imager has been developed that can be closely abutted to other imagers on three sides of the imaging array. It is intended for use in multichip arrays. The device has 420 x 420 pixels in the imaging and frame-store regions and is constructed using a three-phase triple-polysilicon process. Particular emphasis has been placed on achieving low-noise charge detection for low-light-level imaging in the visible and maximum energy resolution for X-ray spectroscopic applications. Noise levels of 6 electrons at 1-MHz and less than 3 electrons at 100-kHz data rates have been achieved. Imagers have been fabricated on 1000-Ohm-cm material to maximize quantum efficiency and minimize split events in the soft X-ray regime.

Burke, Barry E.↗

New concepts for HgI2 scintillator gamma ray spectroscopy

The primary goals of this project are development of the technology for HgI2 photodetectors (PD's), development of a HgI2/scintillator gamma detector, development of electronics, and development of a prototype gamma spectrometer. Work on the HgI2 PD's involved HgI2 purification and crystal growth, detector surface and electrical contact studies, PD structure optimization, encapsulation and packaging, and testing. Work on the HgI2/scintillator gamma detector involved a study of the optical - mechanical coupling for the optimization of CsI(Tl)/HgI2 gamma ray detectors and determination of the relationship between resolution versus scintillator type and size. The development of the electronics focused on low noise amplification circuits using different preamp input FET's and the use of a coincidence technique to maximize the signal, minimize the noise contribution in the gamma spectra, and improve the overall system resolution.

Iwanczyk, Jan S.↗

A predictive model for space-based X-ray CCD degradation

The first generation of X-ray telescopes to use Charge-Coupled Devices (CCDs) is being launched this decade. With a read noise of a few electrons, CCDs provide Fano-limited spectral resolution across the soft X-ray band (0.1 - 10 keV). However, degradation of resolution due to charge transfer losses becomes noticeable as Charge Transfer Inefficiency (CTI) increases to 10(exp -5). In this paper, we present a model which calculates the effects of radiation damage in low Earth orbit in order to predict CCD lifetimes over which good charge transfer is maintained. The model presented here considers damage mechanisms within the CCD, environmental conditions in which the CCD operates, and experiment shielding. We find that the predicted CTI approaches 10(exp -5) after a one to two year mission for the flight instruments considered here.

Antunes, Alex↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗

Reducing Stray Light To Characterize Nirspec Subsystems: The Focal Plane Array And Micro-Shutter Array

The James Webb Space Telescope (JWST) is an infrared, space-based telescope scheduled for launch in 2013. JWST includes four scientific instruments, including the Near Infrared Spectrometer (NIRSpec), which operates in the wavelength range from 0.6 to 5 microns. NASA/Goddard Space Flight Center (GSFC) is responsible for two NIRSpec subsystems: the detector subsystem, with its focal plane array (FPA), and the micro-shutter subsystem, with its micro-shutter array (MSA). The FPA is comprised of two side-by-side Rockwell Scientific HgCdTe 2kx2k detectors, with detectors and readout electronics optimized for low noise. The MSA is a GSFC developed micro-electro-mechanical system (MEMS) that serves as a programmable slit mask, allowing NIRSpec to obtain simultaneous spectra of >100 objects in a single field of view. We present the optical characterization test plan of the FPA. The test plan is driven by many requirements: cryogenic operating temperature, a flight-like beam shape, and multi-wavelength photon flux from 1 to 60,000 per second, thus low stray light is critical. We use commercial optical modeling software to predict stray light effects at the FPA. We also present the optical contrast test plan of the MSA. Since each individual shutter element operates in on/off fashion, the most important optical metric is contrast. The MSA structure is designed to minimize stray and scattered light, and the test setup reduces stray light such that the optical contrast requirement is met.

Connelly, Joseph A.↗

Calibration of International Space Station (ISS) Node 1 Vibro-Acoustic Model-Report 2

Reported here is the capability of the Energy Finite Element Method (E-FEM) to predict the vibro-acoustic sound fields within the International Space Station (ISS) Node 1 and to compare the results with simulated leak sounds. A series of electronically generated structural ultrasonic noise sources were created in the pressure wall to emulate leak signals at different locations of the Node 1 STA module during its period of storage at Stennis Space Center (SSC). The exact sound source profiles created within the pressure wall at the source were unknown, but were estimated from the closest sensor measurement. The E-FEM method represents a reverberant sound field calculation, and of importance to this application is the requirement to correctly handle the direct field effect of the sound generation. It was also important to be able to compute the sound energy fields in the ultrasonic frequency range. This report demonstrates the capability of this technology as applied to this type of application.

Zhang, Weiguo↗