Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Transport of 12 GeV positron beams at Ce+BAF

Jefferson Lab (JLab) is developing a concept to upgrade the Continuous Electron Beam Accelerator Facility (CEBAF) to additionally deliver spin-polarized continuous-wave positron beams for its nuclear physics program users (Ce+BAF 12 GeV). The concept involves repurposing the Low Energy Recirculator Facility (LERF) at JLab as a dual injector, first producing 100-300 MeV spin-polarized electron beams which are subsequently used for the generation and formation of 123 MeV continuous-wave positron beams. The positron beams are transported to CEBAF and injected for acceleration up to 12 GeV, tailored to the requirements of its four experimental halls. Given the higher emittance of the secondary positron beams, the CEBAF optics are optimized for low dispersion and low beta functions to enhance transmission within the Ce+BAF acceptance limits and with an R56 to manage the positron beams bunch length and energy spread. Potential bottlenecks are being investigated through both optical modeling and measurements using an electron beam, as well as degraded electron beams, to map the 6d acceptance of CEBAF as it is today. This presentation shares preliminary results from multi-particle tracking simulations of the positron beam up to 12 GeV, including spatial, momentum, and spin characteristics, and explores the feasibility of delivering beams simultaneously to multiple experimental halls via extraction optics.

Accelerator Physics↗

Light‐driven Transformation of Carbon Monoxide into Hydrocarbons using CdS@ZnS : VFe Protein Biohybrids

Enzymatic Fisher-Tropsch (FT) process catalyzed by vanadium (V)-nitrogenase can convert carbon monoxide (CO) to longer-chain hydrocarbons (>C2) under ambient conditions, although this process requires high-cost reducing agent(s) and/or the ATP-dependent reductase as electron and energy sources. Using visible light-activated CdS@ZnS (CZS) core-shell quantum dots (QDs) as alternative reducing equivalent for the catalytic component (VFe protein) of V-nitrogenase, we first report a CZS : VFe biohybrid system that enables effective photo-enzymatic C−C coupling reactions, hydrogenating CO into hydrocarbon fuels (up to C4) that can be hardly achieved with conventional inorganic photocatalysts. Surface ligand engineering optimizes molecular and opto-electronic coupling between QDs and the VFe protein, realizing high efficiency (internal quantum yield >56 %), ATP-independent, photon-to-fuel production, achieving an electron turnover number of >900, that is 72 % compared to the natural ATP-coupled transformation of CO into hydrocarbons by V-nitrogenase. The selectivity of products can be controlled by irradiation conditions, with higher photon flux favoring (longer-chain) hydrocarbon generation. The CZS : VFe biohybrids not only can find applications in industrial CO removal for high-value-added chemical production by using the cheap, renewable solar energy, but also will inspire related research interests in understanding the molecular and electronic processes in photo-biocatalytic systems.

Chemistry↗

Design of a microbunched electron cooler energy recovery linac

Microbunched electron Cooling (MBEC), a type of Coherent electron Cooling (CeC), is a possible way to cool high energy protons; such an electron cooler can be driven by an energy recovery linac (ERL). The beam parameters of this design are based on cooling 275 and 100 GeV protons at the Electron-Ion Collider (EIC), requiring 150 and 55 MeV electrons, respectively. If implemented, a high energy cooler would serve to increase the average luminosity of the collider by mitigating the emittance growth caused by various processes. This ERL is designed to deliver a bunch charge of 1 nC, an average current of 100 mA, and strict requirements on the transverse emittance, slice energy spread, and longitudinal distribution profile. This paper covers the current state of the design.

Accelerator Physics↗

Dual nature of magnetism driven by momentum dependent f-d Kondo hybridization

The intricate nature of magnetism in uranium-based Kondo lattices is a consequence of correlations between U-5 f and conduction electrons. Previously, the source of magnetism has been ascribed to either Mott physics or Ruderman-Kittel-Kasuya-Yosida interaction, both of which are not fully applicable to uranium-based Kondo lattices. Using linearized quasiparticle self-consistent GW plus dynamical mean-field theory, we demonstrate a crossover from incoherent to coherent f - d Kondo cloud in the paramagnetic phase of UTe 2 , USbTe and USbSe. As the transition occurs, we observe an augmented f - d coherence and Pauli-like magnetic susceptibility, with a substantial frozen magnetic moment of U-5 f persisting. We show that momentum dependent f - d hybridization is responsible for the magnetic moments arising from the renormalized f electrons’ van Hove singularity. Our findings provide a perspective to explain the dual nature of magnetism and the long-range magnetic ordering induced by pressure in UTe 2 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variable frequency response testbed to validate protective relays up to 20 kHz☆

Microgrids operate in islanding or utility grid mode. In islanding mode, distributed energy sources with power electronics inverters can generate fault currents over a wide range of frequencies. To gain a better understanding of the nature of these events, it is crucial to measure currents at frequencies of up to 20 kHz at transient states with protective relays. Protective relays at these frequency responses should be tested prior to being installed in microgrids. However, testing at high-frequency currents cannot be done with Relay Test Equipment (RTE) that generate signals up to 50th Harmonic for 60 Hz (3 kHz). In this study, a frequency response method and testbed for high-frequency currents of up to 20.16 kHz was developed and tested. The testbed utilized a RTE and High-Frequency Power Source/ Amplifier. Furthermore, frequency relay experiments were run at frequencies of up to 1 and 20.16 kHz at a current magnitude of 0.1 and 0.5 A, respectively. The events were collected, and the current magnitude and frequency were plotted at time and frequency domain, respectively. The study of current magnitude and frequencies of up to 20.16 kHz for two overcurrent relays was performed and validated the variable frequency testbed and methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Tunable Resolution Grating Monochromator and the Quest for Transform Limited Pulses

A variable resolution, transform limited monochromator is designed for the Free Electron Laser (FEL) source of LCLS. It provides monochromatic beam in the 250–1500 eV range, delivering the beam on the second floor of the LCLS experimental Hall. One major requirement for this monochromator is to provide, as close as possible, monochromatic transform limited pulses for time-resolved experiments. The theory and the limit of using classical diffraction scheme to monochromatize Soft X-ray beam, while preserving the pulse length, will be presented, together with the optical scheme of this versatile monochromator design.

47 OTHER INSTRUMENTATION↗

Single-shot X-ray absorption spectroscopy at X-ray free electron lasers

X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method for studying electronic and structural properties of matter. At first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of X-ray Free Electron Lasers (XFEL) sources seem to require accumulation over many shots to achieve high data quality. To date the best approach to implementing XAS at XFEL facilities has been using monochromators to scan the photon energy across the desired spectral range. While this is possible for easily reproducible samples such as liquids, it is incompatible with many important systems. Here, we demonstrate collection of single-shot XAS spectra over 10s of eV using an XFEL source, with error bars of only a few percent. We additionally show how to extend this technique over wider spectral ranges towards Extended X-ray Absorption Fine Structure measurements, by concatenating a few tens of single-shot measurements. Our results pave the way for future XAS studies at XFELs, in particular those in the femtosecond regime. This advance is envisioned to be especially important for many transient processes that can only be initiated at lower repetition rates, for difficult to reproduce excitation conditions, or for rare samples, such as those encountered in high-energy density physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonresonant two-photon x-ray absorption in Cu

We present a real-space Green's function theory and calculations of two-photon x-ray absorption (TPA). Our focus is on nonresonant 𝐾-shell TPA in metallic Cu, which has been observed experimentally at intense x-ray free electron laser (XFEL) sources. The theory is based on an independent particle Green's function treatment of the Kramers-Heisenberg equation and an approximation for the sum over nonresonant intermediate states in terms of a static quadrupole transition operator. XFEL effects are modeled by a partially depleted 𝑑 band. This approach is shown to give results for 𝐾-shell TPA in quantitative agreement with XFEL experiment and with a Bethe-Salpeter equation approach. Furthermore, we also briefly discuss many-body corrections and TPA sum rules.

Approximation methods for many-body systems↗

Predicting the oxidation states of Mn ions in the oxygen-evolving complex of photosystem II using supervised and unsupervised machine learning

Abstract Serial Femtosecond Crystallography at the X-ray Free Electron Laser (XFEL) sources enabled the imaging of the catalytic intermediates of the oxygen evolution reaction of Photosystem II (PSII). However, due to the incoherent transition of the S-states, the resolved structures are a convolution from different catalytic states. Here, we train Decision Tree Classifier and K-means clustering models on Mn compounds obtained from the Cambridge Crystallographic Database to predict the S-state of the X-ray, XFEL, and CryoEM structures by predicting the Mn’s oxidation states in the oxygen-evolving complex. The model agrees mostly with the XFEL structures in the dark S 1 state. However, significant discrepancies are observed for the excited XFEL states (S 2 , S 3, and S 0 ) and the dark states of the X-ray and CryoEM structures. Furthermore, there is a mismatch between the predicted S-states within the two monomers of the same dimer, mainly in the excited states. We validated our model against other metalloenzymes, the valence bond model and the Mn spin densities calculated using density functional theory for two of the mismatched predictions of PSII. The model suggests designing a more optimized sample delivery and illumiation systems are crucial to precisely resolve the geometry of the advanced S-states to overcome the noncoherent S-state transition. In addition, significant radiation damage is observed in X-ray and CryoEM structures, particularly at the dangler Mn center (Mn4). Our model represents a valuable tool for investigating the electronic structure of the catalytic metal cluster of PSII to understand the water splitting mechanism.

Plant Sciences↗

Northstar Mo100 Target Beam Spot Size Sensitivity Study

Northstar Mo100 target for production of the medical isotope Mo99 is particularly sensitive to beam over focusing because of the intended high power density. At 38 MeV and 6.32 mA (240 kW beam power, nominally 160 kW th in the target), small deviation from the nominal 12 mm FWHM beam can significantly increase the target disk temperatures and more importantly the load bearing target window temperature. A rhodotron will be the source of the electron beam to be used in the isotope production. This machine operates in a pulsed beam mode, currently expected to be at 50 Hz, which results in a 100 C temperature oscillation above and below the steady state temperature that is the focus of this study. This must be considered in the determination of minimum beam spot size that can be accepted by the target without risk of failure. In addition to the nominal beam spot size of 12 mm, the analysis of 10, 11 and 14.5 mm beam spot sizes are analyzed. The primary conclusion is that an over focused beam to just 11 mm FWHM is the minimum beam spot allowable, based on window temperature and the Ultimate Tensile Stress (UTS) of the window material Inconel 718 as a function of temperature. In contrast an under focused beam of 14.5 mm FWHM has much reduced target and window temperatures, but there is a resulting 6% drop in isotope production, all other factor staying the same. These results are presented herein.

07 ISOTOPE AND RADIATION SOURCES↗

Tapering-enhanced high-efficiency THz waveguide oscillator

Using a waveguide in a THz FEL has been shown to maximize the coupling and enable efficient extraction of relativistic electron beam energy from a single passage through a tapered helical undulator. An oscillator configuration can further boost energy extraction above the single-pass limits and open the door toward very high average power THz sources. Embedding the undulator in an oscillator cavity is particularly useful in combination with high repetition rate electron sources, even if at reduced peak brightness, since recycling a fraction of the radiation as an intense seed can compensate for lower single-pass gain. In this paper, we investigate the efficiency scaling of a tapering-enhanced waveguide oscillator, showcasing its capability for frequency-tuning operation and high-efficiency operation at different wavelengths. Using a thermionic-driven beamline equipped with compression elements, numerical start-to-end simulation results indicate a 16% efficiency at 200 GHz and a 2.1% efficiency at 1.5 THz, resulting in kW-level average power out-coupled in radiation pulses with few hundred μ J energy and tens of MW peak power. Published by the American Physical Society 2024

Yang, Y. N. (ORCID:0009000849540151)↗

Bioresorbable Primary Battery Anodes Built on Core–Double-Shell Zinc Microparticle Networks

Bioresorbable implantable electronics require power sources that are also bioresorbable with controllable electrical output and lifetime. In this paper, we report a bioresorbable zinc primary battery anode filament based on a zinc microparticle (MP) network coated with chitosan and Al 2 O 3 double shells. When discharged in 0.9% NaCl saline, a Zn MP filament with a 0.17 × 2 mm 2 cross-sectional area exhibited a stable voltage output of 0.55 V at a current of 0.01 mA. Covered by chitosan and Al 2 O 3 double shells, the zinc MP filament exhibited a directional dissolution behavior with a tunable lifetime approximately linear to its length. A stable 200 h discharging time was achieved with a 15 mm Zn MP filament. The maximum output power was found to be 12 μW at 0.03 mA for one filament. The linearity relationship between the current output and the filament cross-sectional area suggested a facile strategy to raise the power output at constant discharging voltage. The filaments could also be connected in series and in parallel to boost its overall voltage and current output, demonstrating their excellent integration capability. Furthermore, this work presents a promising pathway toward bioresorbable transient batteries with controllable lifetime and power output, demonstrating a great potential for powering transient implantable biomedical devices.

25 ENERGY STORAGE↗

Ion-Specific Precipitation of Extractants Enables Rare-Earth Separation and Wastewater Remediation from Solvent Extraction of Critical Elements

The increasing demand for rare-earth elements (REEs) necessitates sustainable recovery strategies, particularly from secondary sources, such as electronic waste. Solvent extraction is the primary industrial method for REE separation; however, the unintentional dissolution of extractants into wastewater poses serious environmental risks, leading to organic contamination and process inefficiencies. Existing wastewater treatment methods struggle to remove these persistent pollutants, underscoring the need for innovative recovery approaches. Herein, we present a ligand-mediated precipitation strategy that simultaneously recovers REEs and removes dissolved extractants from solvent extraction wastewater. We show that residual extractants in the aqueous phase can selectively bind REEs, inducing their precipitation while leaving transition metals in solution. By integrating FTIR spectroscopy, EDS, XPS, EXAFS, and SAXS, we elucidate the mechanism of ion-specific precipitation and the local coordination environment of metal ions in the precipitate. Importantly, we demonstrate that the precipitated extractants can be efficiently recovered and reused, providing a closed-loop solution that enhances sustainability. Applying this method to leachates from samarium–cobalt (Sm–Co) and neodymium–iron–boron (NdFeB) mixed magnets, we achieve highly selective REE precipitation under mild conditions, demonstrating a scalable and cost-effective pathway for REE recovery, wastewater purification, and extractant recycling. In conclusion, by integrating element-specific ligand-mediated precipitation with extractant reuse, this work offers a transformative approach to REE separation that reduces the environmental impact while improving resource efficiency.

E-waste↗

High-brightness self-seeded X-ray free-electron laser covering the 3.5 keV to 14.6 keV range

A self-seeded X-ray free-electron laser (XFEL) is a promising approach to realize bright, fully coherent free-electron laser (FEL) sources in the hard X-ray domain that have been a long-standing issue with longitudinal coherence remaining challenging. Additionally, at the Pohang Accelerator Laboratory XFEL, we have demonstrated a hard X-ray self-seeded XFEL with a peak brightness of 3.2 × 10 35 photons s –1 mm –2 mrad –2 0.1% bandwidth (BW) –1 at 9.7 keV. The bandwidth (0.19 eV) is about 1/70 times as wide (close to the Fourier transform limit) and the peak spectral brightness is 40 times higher than in self-amplified spontaneous emission (SASE), with substantial improvements in the stability of self-seeding and noticeably suppressed pedestal effects. We could reach an excellent self-seeding performance at a photon energy of 3.5 keV (lowest) and 14.6 keV (highest) with the same stability as the 9.7 keV self-seeding. The bandwidth of the 14.6 keV seeded FEL was 0.32 eV, and the peak brightness was 1.3 × 10 35 photons s –1 mm –2 mrad –2 0.1%BW –1 . We show that the use of seeded FEL pulses with higher reproducibility and a cleaner spectrum results in serial femtosecond crystallography data of superior quality compared with data collected using SASE mode.

47 OTHER INSTRUMENTATION↗

Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn

X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ~3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ~1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Antiferroelectric Domain Walls in a Uniaxial Hyperferroelectric

Abstract Ferroelectric domain walls are a rich source of emergent electronic properties and unusual polar order. Recent studies show that the configuration of ferroelectric walls can go well beyond the conventional Ising‐type structure. Néel‐, Bloch‐, and vortex‐like polar patterns have been observed, displaying strong similarities with the spin textures at magnetic domain walls. Here, the discovery of antiferroelectric domain walls in the uniaxial ferroelectric Pb 5 Ge 3 O 11 is reported. Highly mobile domain walls with an alternating displacement of Pb atoms are resolved, resulting in a cyclic 180° flip of dipole direction within the wall. Density functional theory calculations show that Pb 5 Ge 3 O 11 is hyperferroelectric, allowing the system to overcome the depolarization fields that usually suppress the antiparallel ordering of dipoles along the longitudinal direction. Interestingly, the antiferroelectric walls observed under the electron beam are energetically more costly than basic head‐to‐head or tail‐to‐tail walls. The results suggest a new type of excited domain‐wall state, expanding previous studies on ferroelectric domain walls into the realm of antiferroic phenomena.

36 MATERIALS SCIENCE↗