District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Observation of intravalley phonon scattering of 2s excitons in MoSe 2 and WSe 2 monolayers

Abstract We present a high-resolution resonance Raman study of hBN encapsulated MoSe 2 and WSe 2 monolayers at 4 K using excitation energies from 1.6 eV to 2.25 eV. We report resonances with the WSe 2 A2s and MoSe 2 A2s and B2s excited Rydberg states despite their low oscillator strength. When resonant with the 2s states we identify new Raman peaks which are associated with intravalley scattering between different Rydberg states via optical phonons. By calibrating the Raman scattering efficiency and separately constraining the electric dipole matrix elements, we reveal that the scattering rates for k = 0 optical phonons are comparable for both 1s and 2s states despite differences in the envelope functions. We also observe multiple new dispersive Raman peaks including a peak at the WSe 2 A2s resonance that demonstrates non-linear dispersion and peak-splitting behavior that suggests the dispersion relations for dark excitonic states at energies near the 2s state are extremely complex.

Materials Science↗

Field Performance of R-1234yf Heat Pump Water Heaters

Heat pump water heaters (HPWH) provide a resource for increasing water heating efficiency in U.S. residences. Electric HPWHs have traditionally utilized R-134a as the refrigerant in the vapor-compression cycle; however, this refrigerant is undesirable long-term due to its high global warming potential. For HPWHs, low global warming potential refrigerants such as R-1234yf may offer comparable performance, but the evaluation of these systems has been limited to laboratory settings. This study provides field evaluations of off-the-shelf HPWHs that had their factory R-134a refrigerant replaced with an optimized charge of R-1234yf. The field evaluation consisted of R-1234yf HPWHs at two occupied field sites and two unoccupied, simulated lab homes. At the two residential field sites with occupants, the R-1234yf HPWHs operated issue-free for the 18-month field trial, and the home occupants perceived no change in HPWH performance relative to their prior R-134a HPWHs. At the lab homes, under simulated hot water draws, the average daily operating efficiency of the R-1234yf HPWH was within 2% of the baseline R-134a HPWHs.

42 ENGINEERING↗

Harmonized geospatial data to support infrastructure siting feasibility planning for energy system transitions

Climate change, energy system transitions, and socioeconomic change are compounding influences affecting the growth of electricity demand. While energy efficiency initiatives and distributed resources can address a significant amount of this demand, the United States will likely still need new utility-scale generation resources. The energy sector uses capacity expansion planning models to determine the aggregate need for new generation, but these models are typically at the state or regional scale and are not equipped to address the wide range of location- and technology-specific issues that are increasingly a factor in power plant siting. To help address these challenges, we have developed the Geospatial Raster Input Data for Capacity Expansion Regional Feasibility (GRIDCERF) data package, a high-resolution product to evaluate siting suitability for renewable and non-renewable power plants in the conterminous United States. GRIDCERF offers 264 suitability layers for use with 56 power plant technologies in a harmonized format that can be easily ingested by geospatially-enabled modeling software allowing for customization to robustly address science objectives when evaluating varying future conditions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enabling Ultra-Compact, Lightweight, Efficient, and Reliable 6.6 kW On-Board Bi-Directional Electric Vehicle Charger with Advanced Topology and Control

The research explored new topologies, control methods, mechanical integration, and thermal management methods for electric vehicle (EV) on-board chargers. The team investigated capacitor-based power conversion, leveraging the high energy densities inherent to capacitive energy storage compared to inductive methods. The proposed topologies simultaneously enabled high power density and high efficiency of the design. The proposed architecture was demonstrated in a 6.6 kW bi-directional charger prototype. The research pursued several directions to improve system performance. Innovative topologies were studied for both the main power conversion stage as well as the single-phase twice-line-frequency energy buffer. To ensure robust and efficient operation, new control methods were developed to integrate these two subsystems. To achieve high power density in the full system solution, the mechanical structure of the charger is highly optimized to maximally fill the converter box volume. In parallel with the mechanical design effort, the converter was packaged with high-performance cooling methods which removed heat from key areas of power dissipation in the converter. The thermal management system was optimized to minimize its weight and volume, ultimately motivating the design of a custom additively manufactured cold-plate. The full system achieves a peak power of 7 kW with less than 0.3% total harmonic distortion (THD) and greater than 0.994 power factor in power factor correction (PFC) operation, corresponding to a total box-volume power density of 47.9 kW/L and gravimetric power density of 24.6 W/g. The system achieves a peak efficiency of 98.9%, with 97.9% efficiency at maximum power.

33 ADVANCED PROPULSION SYSTEMS↗

Tax Credits for Clean Electricity: The Distributional Impacts of Supply-Push Policies in the Power Sector

We evaluate distributional and efficiency consequences of the bulk power clean electricity tax credits authorized by the 2022 Inflation Reduction Act. To do so, we link detailed electricity capacity expansion, computable general equilibrium, microsimulation, and air pollution models to estimate economic welfare and health incidence across demographic groups. We evaluate trade-offs between policy efficiency and income progressivity by comparing the tax credits to cap-and-trade policies. The tax credits encourage increased clean electricity investment, resulting in a reallocation of capital from elsewhere in the economy, higher prices for capital and other goods, lower power prices, and lower emissions. The tax credits yield progressive outcomes for economic welfare at the expense of efficiency while all modeled policies demonstrate progressivity in health impacts. The health benefits, absent climate benefits, exceed total policy costs and provide greater benefits for low-income and historically marginalized households given coincidence of household locations and emissions exposure intensity.

distributional impacts↗

Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT)

The National Renewable Energy Laboratory (NREL) developed the Puerto Rico Energy Efficiency Scenario Analysis Tool (PREESAT) to allow stakeholders to estimate the long-term aggregate electricity consumption impacts of various energy efficiency measures in Puerto Rico’s residential, commercial, and industrial sectors. PREESAT is an energy accounting framework that addresses electricity use. This report provides an overview of the tool and serves as a user manual with instructions for users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Engineering of Ferroic Orders in Thin Films by Anionic Substitution

Multiferroics are a unique class of materials where magnetic and ferroelectric orders coexist. The research on multiferroics contributes significantly to the fundamental understanding of the strong correlations between different material degrees of freedom and provides an energy-efficient route toward the electrical control of magnetism. While multiple ABO 3 oxide perovskites are identified as being multiferroic, their magnetoelectric coupling strength is often weak, necessitating the material search in different compounds. Here, the observation of room-temperature multiferroic orders in multi-anion SrNbO 3-x N x thin films is reported. In these samples, the multi-anion state enables the room-temperature ferromagnetic ordering of the Nb d-electrons. Simultaneously, ferroelectric responses that originate from the structural symmetry breaking associated are found with both the off-center displacements of Nb and the geometric displacements of Sr, depending on the relative O-N arrangements within the Nb-centered octahedra. So findings not only diversify the available multiferroic material pool but also demonstrate a new multiferroism design strategy via multi-anion engineering.

thin-films↗

Engineering Redox Flow Battery Electrodes with Spatially Varying Porosity Using Non‐Solvent‐Induced Phase Separation

Redox flow batteries (RFBs) are a promising electrochemical platform for efficiently and reliably delivering electricity to the grid. Within the RFB, porous carbonaceous electrodes facilitate electrochemical reactions and distribute the flowing electrolyte. Tailoring electrode microstructure and surface area can improve RFB performance, lowering costs. Electrodes with spatially varying porosity may increase electrode utilization and provide surface area in reaction‐limited zones; however, the efficacy of such designs remains an open area of research. Herein, a non‐solvent‐induced phase‐separation (NIPS) technique that enables the reproducible synthesis of macrovoid‐free electrodes with well‐defined across‐thickness porosity gradients is described. The monotonically varying porosity profile is quantified and the physical properties and surface chemistries of porosity‐gradient electrodes are compared with macrovoid‐containing electrode, also synthesized by NIPS. Then, the electrochemical and fluid dynamic performance of the porosity‐gradient electrodes is evaluated, exploring the effect of changing the direction of the porosity gradient and benchmarking against the macrovoid‐containing electrode. Lastly, the performance is examined in a vanadium RFB, finding that the porosity‐gradient electrode outperforms the macrovoid electrode, is independent of gradient direction, and performs favorably compared to advanced electrodes in the contemporary literature. It is anticipated that the approach motivates further exploration of microstructurally tailored electrodes in electrochemical systems.

25 ENERGY STORAGE↗

Scalable membrane-less microbial electrolysis cell with multiple compact electrode assemblies for high performance hydrogen production

Bioelectrochemical hydrogen production via microbial electrolysis cells (MECs) is a promising method for sustainable energy production and decarbonization of energy systems. However, the application of MECs is limited by the electrochemical performance, scalability, and the cost associated with expensive materials. Here, in this study, a scalable MEC (500 mL) with novel compact electrode assemblies and high electrode surface area to volume ratio (160 m 2 /m 3 ) was designed and constructed. The use of membranes, precious metal catalyst, and current collectors with high costs was avoided. A high current density at the steady state of 49.5 ± 5.3 A/m 2 was achieved using acetate as the substrate with phosphate buffer under the applied voltage of 1.01 V. The corresponding volumetric current density was 3948 ± 422 A/m 3 . The compact electrode assembly design limited methane production rate to 3.9 ± 0.2 L/L/D, while achieving a hydrogen production rate of 33.7 ± 1.7 L/L/D. With the suppression of microbial hydrogen consumption, the hydrogen production rate was 39.8 ± 1.9 L/L/D, higher by almost one order of magnitude than those of MECs with scaling up attempts. The compact electrode configuration reduced internal resistance to 88.5 ± 4.4 Ω cm 2 . The energy efficiency based on input electricity was 146 ± 7 % to 189 ± 9 % within the applied voltage range of 0.71 to 1.05 V. The results in this study demonstrated successful scaling up of high performance small MECs and offered a new possible approach of scaling up MECs by stacking high-performance subunits, with no trade-offs on electrochemical performance.

08 HYDROGEN↗

Modeling of the effects of non-equilibrium excitation and electrode geometry on H 2 /air ignition in a nanosecond plasma discharge

In this work, we present the results of two-dimensional modeling of the effects of non-equilibrium excitation and electrode geometry on H 2 /air ignition in a nanosecond plasma discharge. A multiscale adaptive reduced chemistry solver for plasma assisted combustion (MARCS-PAC) based on PASSKEy discharge modeling package and compressible multi-component reactive flow solver ASURF+ is developed and validated. This model is applied to simulate the impact of non-equilibrium plasma excitation and electrode geometry and heat loss on the dynamics of the discharge from streamer to spark and ignition kernel development in a H 2 /air mixture with a pair of cylindrical electrodes. The results show that the plasmagenerated species (N 2 (A), N 2 (B), N 2 (a'), N 2 (C), O( 1 D), O and H) in the spark and afterglow significantly accelerate the ignition kernel development. The increase of discharge voltage at the same total discharge energy promotes the non-equilibrium active species production. It is found that the production of electronically excited species at higher reduced electric field strength is more efficient in enhancing ignition in comparison to the vibrational excitation and heating. Moreover, the 2D simulation clearly reveals that the electric field and active species distribution are highly non-uniform. The streamers are initiated at the sharp outer edges of the negative and positive electrodes by a strong electric field while the electric field is much weaker at the centerline of the electrodes. Furthermore, the simulations reveal that the ignition enhancement is sensitive to the variation of electrode shape, diameter, and gap size due to the changes of electric field distribution and location of streamer formation. A cylindrical electrode produces a larger discharge volume and ignition kernel than the parabolic and spherical electrodes, when the discharge is localized near the axis of the gap. It is found that there is a non-monotonic dependence of ignition kernel size on the electrode diameter and inter-electrode distance. The increase of electrode diameter and gap size above the optimal conditions leads to the reduction of ignition kernel volume, due to the decrease of active species concentration and gas temperature. At a larger electrode surface area and electrode diameter as well as smaller electrode gap size, the heat loss to electrode plays a greater role in reducing the ignition kernel size and slowing ignition kernel development. This work provides insights and guidance to understand the kinetic enhancement of non-equilibrium plasma and the effects of electrode geometries on ignition for the optimization ignitors in advanced engines.

42 ENGINEERING↗

The path to 2060: Saudi Arabia's long-term pathway for GHG emission reduction

Saudi Arabia, as part of its Saudi Green Initiative, has announced its goal to achieve net zero green-house gas emissions by 2060. This ambitious target underscores the nation's dedication to address-ing climate change. However, there is a significant gap in comprehensive analysis regarding the long-term effects of Saudi Arabia's climate policies and their collective contribution towards the net-zero objective. This study endeavors to bridge this gap through a detailed examination using the GCAM-KSA, a specialized version of the Global Change Analysis Model tailored for Saudi Arabia, employing a multi-sectoral methodology that integrates economic, energy, and land use systems within a coherent framework to assess the impact of climate policies on GHG emissions. Our anal-ysis reveals that reaching net-zero GHG emissions by 2060 is a complex challenge requiring con-certed efforts across all sectors of the economy. While transitioning to low-carbon electricity and improving energy efficiency offer considerable emission reductions, fully decarbonizing the indus-trial and transportation sectors poses a significant hurdle. Our findings suggest that Saudi Arabia must triple its emission reduction commitments in its next Nationally Determined Contributions (NDCs) update to align with its 2060 net-zero goal. Early action and increased ambition could avoid the chances of getting locked into the high emission assets and give enough time to transform the energy system. Furthermore, the adoption and integration of Carbon Dioxide Removal (CDR) tech-nologies are identified as crucial for offsetting residual emissions, especially in sectors that might continue to rely on fossil fuels.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stable, high-performing bifunctional electrodes for anion exchange membrane-based unitized regenerative fuel cells

Anion exchange membrane unitized regenerative fuel cells (AEM-URFCs) are a promising technology for energy storage and electricity production; however, their efficiency is limited by the kinetics of the bifunctional oxygen electrode (BOE) where the oxygen evolution reaction (OER) and oxygen reduction reaction (ORR) occur. A particular concern when designing the BOE is that the OER and ORR have differing catalytic requirements, which make it challenging to develop effective bifunctional electrocatalysts with single active sites. In this study, we focus on advancing the BOE performance using Pt-IrO x and Pt-NiCoO x electrocatalysts. Here, single-layer and dual-layer Pt-IrO x BOEs were made, with the dual-layer electrode leading to improved performance due to efficient catalyst utilization in both modes. Using the dual-layer oxygen electrode paired with a PtRu/C hydrogen electrode, a round trip efficiency (RTE) as high as 50% (62 %iR-free) was achieved at 500 mA/cm 2 and operation for more than 24 h, which included five one-hour-long H 2 generation and consumption cycles followed by one eight-hour-long cycle. To the best of our knowledge, this is the highest performance for AEM-URFCs reported to date. Lastly, the approach is extended to electrodes with a Pt loading of 0.5 mg/cm 2 and the IrO x substituted by NiCoO x .

25 ENERGY STORAGE↗

Oriented Electrostatic Effects on O 2 and CO 2 Reduction by a Polycationic Iron Porphyrin

Next-generation energy technologies require improved methods for rapid and efficient chemical-to-electrical energy transformations. One new approach has been to include atomically-positioned, electrostatic motifs in molecular catalysts to stabilize high-energy, charged intermediates. For example, an iron porphyrin bearing four cationic, ortho-N,N,N-trimethylanilinium groups (o-[N(CH 3 ) 3 ] + ) has recently been used to catalyze the complex, multi-step O 2 and CO 2 reduction reactions (ORR and CO 2 RR) with fast rates and at low overpotentials. The success of this catalyst is attributed, at least in part, to specific charge-charge interactions between the atomically-positioned o-[N(CH 3 ) 3 ] + groups and the bound substrate. However, by nature of the mono-ortho substitution pattern, there are four possible atropisomers of this metalloporphyrin and thus four unique electrostatic environments. This work reports that each of the four individual atropisomers catalyzes both the ORR and CO 2 RR with fast rates and low overpotentials. The maximum turnover frequencies (TOF max ) vary among the atropisomers, by a factor of 60 for the ORR and a factor of 5 for CO 2 RR. For the ORR, the αβαβ isomer is the fastest and has the highest overpotential, while for the CO 2 RR, the order is reversed and the αααα isomer is the fastest and has the highest overpotential. The role of charge-positioning is complex and can affect more than a single step such as CO 2 binding. These data offer a first-of-a-kind perspective on atomically positioned charge and highlight the significance of high charge density, rather than orientation, on the thermodynamics and kinetics of multistep molecular electrochemical transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results of the KRUSTY Nuclear System Test

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY nuclear system test, which operated the power system at various temperatures and power levels for 28 consecutive hours. The testing showed that the system operated as expected and that the reactor is highly tolerant of possible failure conditions and transients. The key feature demonstrated was the ability of the reactor to load-follow the demand of the power conversion system. The thermal power of the test ranged from 1.5 to 5.0 kW(thermal), with a fuel temperature up to 880°C. Each 80-W(electric)–rated Stirling converter produced ~90 W(electric) at a component efficiency of ~35% and an overall system efficiency of ~25%.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Modeling of a Fast Spectrum Molten Salt Reactor Integrated Energy System

Liquid-fueled molten salt fast reactors and nuclear-powered integrated energy systems (IESs) have the potential to play a pivotal role in the green energy transition. However, these systems have little to no operating experience. There is therefore increased interest and value in modeling and simulating these systems. The IES dynamic model developed in this work utilizes a lumped-parameter control volume methodology to investigate the behavior of the IES in a variety of accident scenarios. The results provide initial evidence for the potential inherent safety of the advanced reactor because of temperature-dependent reactivity feedback and the efficiency of hydrogen and electricity production at the high temperatures provided by the advanced reactor.

MCFR↗

Online Detection of Power Grid Anomalies via Federated Learning

Data from sensors is critical for advanced applica- tions that support efficient, reliable, and resilient electric grid operations. Historically, data from phasor measurement units (PMU) has been utilized to develop a wide variety of wide area control and protection applications suitable for power grid control centers. However, until now, most of these could not be deployed for automated operations due to a set of data corruption challenges and uncertainty in the incoming data pipeline. In this paper, we address the problem of detecting different variety of anomalies that are evident in different high- speed power grid measurements. The paper discusses a workflow for handling problems with data acquisition and highlights some of the key findings suitable for anomaly detection in a centralized and distributed environment. The effectiveness of the proposed method was demonstrated with results utilizing realistic PMU datasets

Shinkle, Matthew W.↗