Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric drive technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Field-free topological behavior in the magnetic domain wall of ferrimagnetic GdFeCo

Exploring and controlling topological textures such as merons and skyrmions has attracted enormous interests from the perspective of fundamental research and spintronic applications. It has been predicted theoretically and proved experimentally that the lattice form of topological meron-skyrmion transformation can be realized with the requirement of external magnetic fields in chiral ferromagnets. However, such topological transition behavior has yet to be verified in other materials. Here, we report real-space observation of magnetic topology transformation between meron pairs and skyrmions in the localized domain wall of ferrimagnetic GdFeCo films without the need of magnetic fields. The topological transformation in the domain wall of ferrimagnet is introduced by temperature-induced spin reorientation transition (SRT) and the underlying mechanism is revealed by micromagnetic simulations. The convenient electric-controlling topology transformation and driving motion along the confined domain wall is further anticipated, which will enable advanced application in magnetic devices.

36 MATERIALS SCIENCE↗

Transition Metal Blocking Microporous Polymer Separators for Energy-Dense and Long-Lived Li-ion Batteries

A revolution in electric-powered mobility is imminent, catalyzed by breakthroughs in Li-ion battery technology that have dramatically lowered the $/kWh price tag of electrochemical energy storage. Increases in production have also enabled greater penetration in key markets. World-wide registration of new plug-in hybrid electric and battery-only electric vehicles (PHEV and BEV) increased by 70% from 2014 to 2015, and sales of PHEVs and BEVs are predicted to be 35% of all vehicle sales by 2040, reaching 41 million units per year—a 90-fold increase from 2015.1,2 In stride with industry giants such as Tesla, EV manufacturers rely on Li-ion cell Original Equipment Manufacturers (OEMs) for relentless improvements in Li-ion battery technology necessary to drive this bullish market penetration outlook. Advancing energy and power density is critical to alleviating EV-customer range anxiety. Furthermore, strategies to extend battery-pack life beyond 1000 cycles—particularly when operating under aggressive duty cycles—requires fresh perspectives and innovation in cell components.

36 MATERIALS SCIENCE↗

High-Voltage High-Energy Stretched Lens Array Square-Rigger (SLASR) for Direct-Drive Solar Electric Propulsion

Development is underway on a unique high-voltage, high-energy solar concentrator array called Stretched Lens Array Square-Rigger (SLASR) for direct drive electric propulsion. The SLASR performance attributes closely match the critical needs of solar electric propulsion (SEP) systems, which may be used for space tugs to fuel-efficiently transport cargo from low earth orbit (LEO) to low lunar orbit (LLO), in support of NASA s robotic and human exploration missions. Later SEP systems may similarly transport cargo from the earth-moon neighborhood to the Mars neighborhood. This paper will describe the SLASR technology, discuss SLASR developments and ground testing, and outline plans for future SLASR technology maturation.

Howell, Joe T.↗

High-voltage Array Ground Test for Direct-drive Solar Electric Propulsion

Development is underway on a unique high-power solar concentrator array called Stretched Lens Array (SLA) for direct drive electric propulsion. These SLA performance attributes closely match the critical needs of solar electric propulsion (SEP) systems, which may be used for "space tugs" to fuel-efficiently transport cargo from low earth orbit (LEO) to low lunar orbit (LLO), in support of NASA s robotic and human exploration missions. Later SEP systems may similarly transport cargo from the earth-moon neighborhood to the Mars neighborhood. This paper will describe the SLA SEP technology, discuss ground tests already completed, and present plans for future ground tests and future flight tests of SLA SEP systems.

Howell, Joe T.↗

Lightweight, Efficient Power Converters for Advanced Turboelectric Aircraft Propulsion Systems

NASA is investigating advanced turboelectric aircraft propulsion systems that use superconducting motors to drive multiple distributed turbofans. Conventional electric motors are too large and heavy to be practical for this application; therefore, superconducting motors are required. In order to improve aircraft maneuverability, variable-speed power converters are required to throttle power to the turbofans. The low operating temperature and the need for lightweight components that place a minimum of additional heat load on the refrigeration system open the possibility of incorporating extremely efficient cryogenic power conversion technology. This Phase II project is developing critical components required to meet these goals.

Hennessy, Michael J.↗

Automotive Power Electronics and Electric Machine Thermal Management

The transition to modular and scalable electrified vehicle transportation requires technologies to improve power density within cost and reliability constraints to maximize vehicle platform flexibility. Key research challenges arise due to the limited packaging space, coolant distribution, electrical connections, and ambient temperatures. Challenges include thermal management for compact power-dense electric machines and the associated power electronics for power management within the vehicle. High-temperature silicon and wide-bandgap (WBG) based power electronics systems are of interest to enable compact and efficient electric drive systems. The higher temperatures present packaging challenges for thermal management and reliability. In this work, we provide an overview of research for thermal characteristics of materials, packages and thermal management approaches for enabling compact power dense automotive electric drive systems.

DIRECT ENERGY CONVERSION↗

Paths Forward: Approaches to Achieve Plug and Process Load Efficiency and Control in Commercial Buildings: Preprint

To accomplish net-zero carbon in the built environment by 2050, we must equitably decarbonize commercial buildings, which includes reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not directly associated with major building end uses like lighting and heating, ventilating, and air conditioning. PPLs account for a growing portion of U.S. commercial building energy consumption. Although commercial building PPL strategies and technologies are available today, they have not been adopted at a level sufficient to achieve significant savings and load flexibility across the building stock. In our "Pathways to Plug and Process Load Efficiency and Control" study, we investigated why these technologies and strategies have not seen widespread adoption and identified five behavior and technology pathways to increase PPL reduction in commercial buildings. In this paper, we expand beyond identifying the pathways and discuss approaches for achieving them. We discuss the importance of collecting and sharing data and case studies on PPL energy consumption and savings from control technology implementation, including code-required measures, for increasing adoption. Centralizing case studies and data, engaging industry organizations, and promoting awareness of PPL efficiency benefits to relevant groups are also key approaches. Additionally, funding, incentives, and rebate programs play important roles in driving PPL efficiency and control adoption. Finally, we discuss integrating PPL efficiency into broader company goals, such as environmental, social and governance (ESG) strategies and green building certifications, to further drive adoption.

adoption pathways↗

Flux-Switching Machine Based All-Electric Power Train for Future Aircraft

This research investigates a flux-switching motor with superconducting and cryogenically cooled windings, aimed at achieving exceptionally high power densities. In addition to the motor’s topology and superconducting windings, it was found that power density could be further enhanced by incorporating superconducting shields on the rotor at the interpole locations. The resulting publications and patented technology outline the design process. A motor power density of 64 kW/kg—including housing materials—was achieved for a 1 MW design, surpassing the performance of existing motors. An electronic drive was also developed, achieving a power density of 47 kW/kg. This includes the mechanical structure of the drivetrain, for which a detailed CAD model was created, resulting in an overall drivetrain power density of 27 kW/kg.

33 ADVANCED PROPULSION SYSTEMS↗

Recent Advances in Analysis and Design of Axial Flux Permanent Magnet Electric Machines

Axial flux permanent magnet machines (AFPM) are popular for applications that benefit from high torque density and an axially compact form factor, such as in-wheel traction drives. Although the radial flux permanent magnet machine (RFPM) and the AFPM work based on the same underlying principle, the differences in their geometry introduce complexities in analysis of the AFPM. In this paper, the different AFPM design variants, their sizing approaches, computationally efficient design optimization techniques, and manufacturing techniques reported in literature are reviewed. In addition to classical AFPM machines, emerging variants and research opportunities with potential to push the boundaries of electric machine technology are reviewed. These include bearingless AFPMs, magnetically geared AFPMs, and combined radial-axial flux machines.

Nishanth, FNU↗

A methodology to develop multi-physics dynamic fuel cell system models validated with vehicle realistic drive cycle data

Fuel cell (FC) technology has been identified as a technically attractive solution to decarbonize the transportation sector, especially for heavy-duty vehicles. In this context, the industry and the scientific community are in need of advanced fuel cell systems (FCS) models that are able to replicate real -world operating conditions. Due to the scarcity of said models in the open literature, this study aimed to develop a comprehensive methodology to calibrate and validate multi -physics dynamic FCS models. Therefore, the key contribution of this paper is the detailed description of the calibration process for each component and the calibration order. The specific focus here was to accurately describe the behavior of the FC stack as well as the cathode, anode, and cooling circuits of the balance of plant. The model was calibrated with the aid of experimental data from a Toyota Mirai FC electric vehicle, which was predominantly retrieved from the vehicle's Controller Area Network (CAN) bus system thereby negating the need for major intrusion into the powertrain system. The validation process was deemed successful with the model being able to truthfully replicate the characteristics of the FC vehicle operated on the World-wide harmonized Light duty Test Cycle (WLTC) 3b and US06 driving cycle. The time -resolved physical parameters such as the cathode pressure, mass flow, or the FC stack temperature were captured with high fidelity, while the overall performance parameters such as the H2 consumption in the stack and the system, and the compressor energy consumption were predicted accurately with a deviation lower than 0.47%, 1.75% and 1.89% with respect to the experimental data, respectively.

Lopez-Juarez, Marcos↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design study of flat belt CVT for electric vehicles

A continuously variable transmission (CVT) was studied, using a novel flat belt pulley arrangement which couples the high speed output shaft of an energy storage flywheel to the drive train of an electric vehicle. A specific CVT arrangement was recommended and its components were selected and sized, based on the design requirements of a 1700 KG vehicle. A design layout was prepared and engineering calculations made of component efficiencies and operating life. The transmission efficiency was calculated to be significantly over 90% with the expected vehicle operation. A design consistent with automotive practice for low future production costs was considered, together with maintainability. The technology advancements required to develop the flat belt CVT were identified and an estimate was made of how the size of the flat belt CVT scales to larger and smaller design output torques. The suitability of the flat belt CVT for alternate application to an electric vehicle powered by an electric motor without flywheel and to a hybrid electric vehicle powered by an electric motor with an internal combustion engine was studied.

Kumm, E. L.↗

Carbon Corrosion in CO2 Electrolysis Systems

Driven by concerns over climate change, interest in CO2 conversion technologies has dramatically increased in recent years. By viewing CO2 as a readily available feedstock, many pathways for the production of carbon-neutral fuels and chemicals become available. In converting CO2, low carbon emitting energy sources must be used to ensure a low carbon footprint of the fuel and chemical products. The low-temperature electrochemical conversion of CO2 is a promising technology and allows for direct integration with renewable electricity sources. The development of low-temperature CO2 electrolysis technologies is informed by both PEM fuel cells and water electrolyzers, both of which are at a higher stage of development. However, CO2 electrolysis operates at a much higher cell voltage (-3V) than other low-temperature electrochemical processes, which can have implications for materials compatibility in the electrolyzer device. Carbon corrosion is of particular concern for the anode of CO2 electrolyzers, as a large driving force for corrosion exists due to the high required cell potentials. In this presentation, recent observations will be shared on carbon corrosion of the anode gas diffusion electrode (GDE) in low-temperature alkaline exchange membrane CO2 electrolysis. Results from ex-situ tests designed to isolate the carbon corrosion process for anode GDEs will be shared. These results will provide guidance on materials selection for CO2 utilization MEAs, which need to have a lifetime of several years to ensure industrial viability.

BIOMASS FUELS↗

Optimal Dispatch for the US Virgin Islands to Increase Renewable Rates in Saint Croix

The US Virgin Islands, like many other small island nations, face significant challenges related to its energy supply. Their dependency on imported fossil fuels not only drives up energy costs, but also contributes to different environmental problems. Nevertheless, their generally sunny and windy climate makes this archipelago an ideal location for renewable energy development. Increasing the use of sources such as wind, and solar can help reduce their energy dependency, lower their levelized cost of electricity, and improve the health and wellbeing of local communities. In this paper, an optimal dispatcher is employed to analyze the implications on energy security of employing different technology options according to the plans of the local system operator. In this context, short term stability is ensured by inserting operational constraints in the energy management system based on stability analysis developed in PSCAD. The results highlight the usefulness of integrating PV and battery system, while further analysis are required to justify integrating wind power.

energy islands↗

Electrical Validation Testing for ORPC MHK Generator, Modification 6: ORPC SBV for MHK Generator System (CRADA Final Report)

For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.

17 WIND ENERGY↗

Updated Assessment of Turboelectric Boundary Layer Ingestion Propulsion Applied to a Single-Aisle Commercial Transport

Recent advances in technology and a push for more environmentally friendly air transportation has led to interest in electrified aircraft propulsion (EAP). EAP encompasses many different propulsion system architectures which can also enable new, synergistic propulsion-airframe integration approaches. This report evaluates the combination of turboelectric EAP and fuselage boundary layer ingestion (BLI) propulsion in a concept called “STARC-ABL.” The predicted fuel consumption benefits of STARC-ABL are updated from a prior 2016 study with new mission requirements and analysis methodologies. Additionally, certification noise is added to the concept evaluation. To properly assess the impact of EAP, a new concept, “ST-ABL,” is developed for comparison which includes the fuselage BLI propulsor driven mechanically instead of by a turboelectric system. STARC-ABL is predicted to provide a 3.4% reduction in fuel consumption for a single-aisle class, 3500 nmi design mission and a 2.7% reduction for a 900 nmi mission, both relative to an advanced technology conventional aircraft. STARC-ABL is also predicted to have a Chapter 14 cumulative noise margin of 7 EPNdB. The non-EAP ST-ABL concept results in slightly higher fuel consumption and noise than STARC-ABL, indicating that the turboelectric system provides benefits over the mechanical drive approach to fuselage BLI. Areas for future research and evolution of the concept include assessing its applicability to other aircraft sizes, increasing the fidelity of BLI and electric component modeling, and investigating other EAP architecture options.

BLI↗

Enabling Universal Access to Power on the Lunar Surface

The National Aeronautics and Space Administration (NASA) Artemis Missions will return human astronauts to the lunar surface, demonstrate technologies that establish a sustained presence on the lunar surface and enable human missions to Mars, and help create a lunar commercial economy. Creating a sustained permanent presence on the lunar surface will require access to continuous and highly reliable power to support mission needs. During Artemis, lunar surface operations will evolve and grow over time (years), requiring an increase in the amount of power needed (100s of kW) and distance that the power must be transmitted (up to 10 km during early Artemis missions). A lunar commercial economy is likely to exceed this power demand to the MW level and distance in the 100s of km. This increased distance and demand for highly reliable power drives the need to create an electric power grid by connecting localized lunar power systems (e.g., habitats, in-situ resource utilization plants, etc.), each containing one or more loads and/or sources. Developing a lunar surface power grid will allow lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient and required. A lunar surface electric power grid will facilitate the growth of a lunar commercial economy because it provides a means to connect new loads to an existing electrical power system. A common standardized interface to the grid and a set of standardized voltages is required to take full advantage of the benefits of an electric power grid, similar to the terrestrial power grid. NASA Glenn Research Center is leading an effort to create universal access to power through the development of the Universal Modular Interface Converter (UMIC). The UMIC is designed to have a common interface that connects sources and loads compliant with the International Space Power System Interoperability Standard (ISPSIS) to a higher voltage AC transmission system or power grid. This presentation will further discuss the evolution of power during the Artemis missions, challenges associated with creating a sustained presence on the lunar surface, progress made on the UMIC, and future opportunities for technology development and standards.

space power systems↗

A Hybrid Heavy Duty Diesel Power System for Off-Road Applications—Concept Validation

A multiyear power system R&D program was completed with the objective of developing an off-road hybrid heavy duty diesel engine with front end accessory drive-integrated energy storage. This system was validated to deliver 10.5–25.6% reduction in fuel consumption over current Tier 4 Final-based 18L diesel engines, over various off-road machine application cycles. The power system consisted of a downsized heavy-duty diesel 13L engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, thermal barrier coatings, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy assisting and recovery through both mechanical and electrical systems. Following the concept definition, design, and analysis phases of the program, the final phase focused on building and validating the performance and efficiency in laboratory tests. While aspects of the system such as start/stop and reduced off-road cooling package energy losses were only analytically evaluated, the main 13L concept engine with full hybrid system was successfully built and tested in steady-state and in transient certification and real-world application cycles. Extensive simulations in Caterpillar's DYNASTY™ software environment utilized the validation test data to assess performance more fully and confidently over varied cycles and strategies. An average fuel consumption reduction of 17.9% was realized, and the majority (~13%) of the benefit stemmed from the core concept 13L engine. In conclusion, a total cost of ownership analysis provides context to commercial viability and where adoption focus should be placed.

33 ADVANCED PROPULSION SYSTEMS↗