Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “efficacy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study

PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histologically-Proven Efficacy of Bland Embolization in a Patient with Net Liver Metastasis

We present a case of 57-year-old patient with three liver metastases from a primary neuroendocrine duodenal tumor, who underwent bland embolization with excellent response to therapy, followed by surgical resection. The purpose of our case report is to describe the histological characteristics of tumoral response to therapy after bland embolization focusing on intralesional necrosis and microsphere distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cryoablation of Hepatocellular Carcinoma with High-Risk for Percutaneous Ablation: Safety and Efficacy

PurposeThe aim of this study was to evaluate the safety and effectiveness of cryoablation in the treatment of subcapsular hepatocellular carcinoma (HCC) adjacent to various organs.Materials and MethodsTwenty-eight patients with subcapsular HCC were treated with cryoablation in our institution. The degree of peri-procedural pain was measured using the visual analog scale (VAS). Technical success, local tumor progression, and overall disease progression rates were calculated. Procedure-related complications were identified by reviewing electronic medical records. Biochemical data, including serum aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin levels before and after the procedure were collected.ResultsSubcapsular HCC tumors were located near the gallbladder, colon, stomach, kidney, diaphragm, or abdominal wall. The technical success rate of cryoablation was 96.4 % (27/28). Local recurrence- and progression-free survival rates were 96 and 84 % at 6 months, and 82 and 43 % at 1 year, respectively. All patients survived during the follow-up period. The VAS pain score ranged from 0 to 3 (mean, 1.57). A major complication occurred in one patient (3.6 %) and minor complications occurred at a rate of 17.9 %. Transient elevations of serum AST, ALT, and bilirubin levels were observed.ConclusionCryoablation is a safe and an effective procedure for the treatment of subcapsular HCC adjacent to various major organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cinnamic Acid Derivatives Enhance the Efficacy of Transarterial Embolization in a Rat Model of Hepatocellular Carcinoma

IntroductionWe hypothesize that the combination of transarterial embolization (TAE) plus inhibition of lactate export will limit anaerobic metabolism and reduce tumor survival compared to TAE alone. The purpose of this study was to test this hypothesis in a rat model of hepatocellular carcinoma (HCC).MethodsRat N1-S1 hepatoma cells were assayed in vitro using the Seahorse XF analyzer to measure extracellular acidification (lactate excretion) comparing effects of the addition of caffeic acid (CA) or ferulic acid (FA) or UK-5099 with control. Monocarboxylate transporter Slc16a3 was knocked down by RNAi. N1S1 tumors were orthotopically implanted in rats and 4 groups evaluated: (1) Control, (2) TAE-only, (3) TAE plus CA, and (4) TAE plus FA. Tumor size was determined by ultrasound and analyzed by repeated measures statistics. Tumors harvested at 4 weeks were examined by microscopy.ResultsSeahorse assays showed that CA and FA caused a significant reduction by >90% in lactate efflux by N1S1 tumor cells (p < 0.01). Knockdown of Slc16a3 prevented inhibition by CA. In vivo tumors grew 30-fold in volume over 4 weeks in untreated controls. By comparison, TAE resulted in near cessation of growth (10% in 4-week time period). However, both TAE + CA and TAE + FA caused a significant reduction of tumor volumes (87 and 72%, respectively) compared to control and TAE (p < 0.05). Pathologic evaluation revealed residual tumor in the TAE group but no residual viable tumor cells in the TAE + CA and TAE + FA groups.ConclusionAddition of CA or FA enhances the effectiveness of TAE therapy for HCC in part by blocking lactate efflux.

60 APPLIED LIFE SCIENCES↗

Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 at baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of Automated Supplying Artery Tracking Software Using Multidetector-Row Computed Tomography Images for Emergent Transcatheter Arterial Embolization

PurposeTo assess the reliability of a prototype automated supplying artery tracking software (ASATS) using multidetector-row CT (MDCT) images in emergent TAE.Materials and MethodsConsecutive 53 patients underwent 57 sessions of emergent TAE during 7 months. Twenty-one cases were excluded due to a lack of CT data (n = 12) or negative angiographic findings (n = 9). Remaining 34 sessions of TAE and MDCT images in 32 patients (mean age 62.9 years; age range 37–92 years) were enrolled. ASATS was retrospectively conducted for the identification of supplying arteries which were confirmed with angiography (automated method). Manual modification was added as needed (semi-automated method). Two observers independently reviewed the MDCT images to detect supplying arteries (manual method). Detectability of supplying artery and time to analysis were compared among the automated, semi-automated, and manual methods by both observers.ResultsA total of 64 bleeding sites were demonstrated on angiography. The detectability was 28 (43.8%) for automated method, 53 (82.8%) for semi-automated method, 55 (85.9%) for observer 1, and 58 (90.6%) for observer 2. Detectability of semi-automated method was significantly better than of automated method (P = 0.000) and comparable with manual method by both observers (P = 0.193 and 0.081). Average time to analysis was 185.4 s for automated method, 297.2 s for semi-automated method, 186.2 s for observer 1, and 243.7 s for observer 2.ConclusionASATS has a sufficient ability to identify supplying arteries of bleeding by adding manual modification as needed and can be used for emergent TAE. Level of Evidence: Level 4, Case Control Study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of the Vertebral Body Stenting System for the Restoration of Vertebral Height in Acute Traumatic Compression Fractures in a Non-osteoporotic Population

Introduction: To evaluate the effectiveness of percutaneous image-guided vertebral body stenting (VBS) at restoring vertebral height in acute, stable, traumatic thoracolumbar fractures in a young, non-osteoporotic population. Materials and Methods: A single-centre retrospective review of all traumatic non-osteoporotic fractures treated with VBS between 2010 and 2017 was performed. Inclusion criteria included patients with recent (< 10 days), symptomatic and stable thoracolumbar compression fractures. Patients with low-energy fractures, osteoporosis and age > 60/50 years (male/female) were excluded. Primary outcomes included: correction of vertebral height, correction of kyphosis angle and Beck Index on reconstructed pre- and post-procedural CBCT images. Secondary outcomes included intra-procedural stent recoil, complications, cement leakage and factors predicting height restoration. Results: Thirty-nine patients (26 men, 13 women; mean age 33.6 years, range 15–57 years) underwent VBS 5 days post-trauma on average (range 1–10), for stable compression fractures located between T5 and L5. Mean vertebral height gain, vertebral kyphosis angle correction and Beck index improvement were 3.8 mm (95% CI 3.36–4.50; P(> 3 mm) = 99.9%), 4.3° (95% CI 3.50–5.20; P(> 3°) = 99.9%) and 0.07 [95% CI 0.053–0.11], respectively (all statistically significant). Technical success was 92%, with 3 “major” stent recoils resulting in loss of vertebral height correction. No symptomatic complications were observed. No predictive factors for procedural success were identified. Conclusion: VBS can significantly restore vertebral height in young patients with traumatic vertebral compression fractures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photo-Stabilisation and UV Blocking Efficacy of Coated Macro and Nano-Rutile Titanium Dioxide Particles in Paints and Coatings

Surface treated macro and nanoparticle TiO{sub 2} samples have been prepared, characterised and their efficiency as UV blockers evaluated in clear coatings and paints. The particle size of the ‘base’ TiO{sub 2} has been optimised to block UV radiation and the surface treatment developed to deactivate the photocatalytic activity of the surface of the TiO{sub 2} particles. The resultant UV blockers have been evaluated in both solvent and water-based clear coatings. Nanoparticle TiO{sub 2} has been prepared from ‘seed’ and the particle size was controlled by calcination. It was found that the choice of particle size is a compromise between UVA absorption, UVB absorption, visible transmission and photoactivity. It has been demonstrated that TiO{sub 2} with a crystallite size of 25 nm yields a product with the optimum properties. A range of dispersants was successfully used to disperse and mill the TiO{sub 2}. Both organic and inorganic dispersants were used; 2-amino-2-methyl-1-propanol and 1-amino-2-propanol (MIPA) and P{sub 2}O{sub 5} and Na{sub 2}SiO{sub 3} respectively. The surface of the nano-TiO{sub 2} was coated with mixed oxides of silicon, aluminium, zirconium and phosphorous. Addition of the resultant coated nano-rutiles to an Isocyanate Acrylic clear coating prolonged the lifetime of that coating compared to the blank. Generally, a surface treatment based on SiO{sub 2}, Al{sub 2}O{sub 3} and P{sub 2}O{sub 5} was more successful than one based on ZrO{sub 2}, Al{sub 2}O{sub 3} and P{sub 2}O{sub 5}. Higher addition levels of the surface treatment were beneficial for protecting the polymeric coating. The UV blocker products were also evaluated in a water-based acrylic, first a water-based dispersion of the UV blocker was prepared before addition to the acrylic. The dispersions and resultant acrylic thin films were evaluated using UV/Vis spectroscopy and durability assessed. The ratio of absorbance at 300:500 nm for the water-based dispersion was shown to be a good predictor of both the transparency of the resultant acrylic thin film and the durability of that film, in terms of weight loss. Macro grade titanium dioxide pigments were also prepared and coated with treatments of silica, alumina and siloxane and their photo-stabilising activity in alkyd paint film assessed and found to be directly related to the electron–hole pair mobility and trapping as determined by micro-wave spectroscopy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Arabic Gum as Bio-Synthesizer for Ag–Au Bimetallic Nanocomposite Using Seed-Mediated Growth Technique and Its Biological Efficacy

Bio-synthesis of nanostructures is an ever green approach; therefore, the current work attempts to use Arabic gum as bio-synthesizer for manufacturing Ag–Au bimetallic nanocomposite, using seed-mediated growth technique. The relevance of the as-used natural gums for manufacturing of Ag–Au nanocomposite in quite simple, energy saving and cost effective methodology, has been successfully approved. Arabic gum acted concurrently as a reducer for metal ions to nano-sized structures and crystal growth modifier of the so-generated nanocomposite. Monitoring of interchanging in size distribution of the as-produced bimetallic nanocomposite by the effect of the gum concentration, concentration of nanometals precursors, their addition sequencing in reaction liquor, and reaction temperature, was illustrated and well characterized. UV–Visible spectra showed that the characteristic surface plasmon resonance peak for Ag–Au bimetallic nanocomposite was observed at 480–495 nm and XRD patterns confirmed the preparation of bimetallic nanostructures. According to zetasizer analyses and TEM micrographs, small sized (3.1 nm) Ag–Au bimetallic nanocomposite with narrow size distribution (1–7 nm) were obtained. The all prepared bimetallic nanocomposite showed good stability with polydispersity index ranged in 0.203–0.530. The mechanism of nanostructures’ generation was suggested and approved using FT-IR, 1HNMR and 13CNMR spectra. The prepared Ag–Au bimetallic nanocomposites showed excellent antibacterial activity against both of gram + ve and gram − ve strains.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Superparamagnetic Properties and Significant Applications of Iron Oxide Nanoparticles for Astonishing Efficacy—a Review

This paper reviewed the comprehensive literature survey on the physical, chemical, and the catalytic properties and applications of iron oxide nanoparticles. In recent years, iron oxide has made a versatile progress due to its outstanding magnetic property. The average crystallite size was reported in previous literatures in the range of 10–45 nm using Scherrer’s formula. The powder morphology was found to deliberate quasi-spherical and predominantly spherical shape. The specific surface area as measured by N{sub 2} adsorption BET isotherm was reported in the range of 17.6–26.21 m{sup 2}/g. Depending on the synthesis pathway there was, an inverse or normal spinel structure could be achieved. X-ray diffraction analysis revealed the crystallite size in the range between 8 and 42 nm. Fourier transform infrared spectroscopy reported the changes in functional group, stretching vibrations in the iron oxide nanoparticles. Scanning electron microscopy analysis showed most of Fe{sub 3}O{sub 4} nanoparticles were in spherical morphology with the particle size range between 10 and 26 nm. Vibrating sample magnetometer reported the magnetization value for Fe{sub 3}O{sub 4} nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

MPC-1 expression in myeloma cells is associated with the efficacy of bortezomib therapy

The use of bortezomib in the clinic has significantly improved outcomes for patients with multiple myeloma (MM), even those harboring high-risk cytogenetic abnormalities or those classified in the high-risk category according to the International Staging System (ISS). In this study, we analyzed the association between immunophenotyping on myeloma cells and the clinical outcomes of patients who received bortezomib-based regimens as first-line therapy. Immunophenotypic analysis before bortezomib therapy was performed by flow cytometry, and whether the immunophenotyping results influenced the clinical outcomes of the patients was investigated. Seventy-four newly diagnosed patients with MM were included in this study. We found that the expression of MPC-1 significantly predicted the time to next therapy (TNT), with a longer TNT in the MPC-1 positive group (p = 0.005), whereas it did not affect overall survival (OS; p = 0.773). In addition, we found that CD45-positivity was associated with shorter TNT (p = 0.0432). Following ISS assessment at treatment initiation, patients who were classified as stage I showed a slightly longer OS compared to those at stage II or III; however, these results were not significant (p = 0.0987). Furthermore, multivariate analysis revealed the prognostic significance of MPC-1 expression, as MPC-1-negativity was associated with a worse TNT. The combination of MPC-1 and CD45 status more sensibly predicted the TNT for bortezomib therapy. Our results demonstrate the clinical importance of immunophenotyping on myeloma cells to determine patient prognoses in this era of novel therapeutic agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗