Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Dissipative Effects in the Effective Field Theory of Inflation

We generalize the effective field theory of single clock inflation to include dissipative effects. Working in unitary gauge we couple a set of composite operators, {Omicron}{sub {mu}{nu}}..., in the effective action which is constrained solely by invariance under time-dependent spatial diffeomorphisms. We restrict ourselves to situations where the degrees of freedom responsible for dissipation do not contribute to the density perturbations at late time. The dynamics of the perturbations is then modified by the appearance of 'friction' and noise terms, and assuming certain locality properties for the Green's functions of these composite operators, we show that there is a regime characterized by a large friction term {gamma} >> H in which the {zeta}-correlators are dominated by the noise and the power spectrum can be significantly enhanced. We also compute the three point function <{zeta}{zeta}{zeta}> for a wide class of models and discuss under which circumstances large friction leads to an increased level of non-Gaussianities. In particular, under our assumptions, we show that strong dissipation together with the required non-linear realization of the symmetries implies |f{sub NL}| {approx} {gamma}/c{sub s}{sup 2} H >> 1. As a paradigmatic example we work out a variation of the 'trapped inflation' scenario with local response functions and perform the matching with our effective theory. A detection of the generic type of signatures that result from incorporating dissipative effects during inflation, as we describe here, would teach us about the dynamics of the early universe and also extend the parameter space of inflationary models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Pressure Neutron Diffraction Study on H-D Isotope Effects in Brucite

A neutron powder diffraction study of hydrogenated and deuterated brucite was conducted at ambient temperature and at pressures to 9 GPa, using a Paris-Edinburgh high-pressure cell at the WAND instrument of ORNL High Flux Isotope Reactor. The two materials were synthesized by the same method and companion measurements of neutron diffraction were conducted under the same conditions. Our refinement results show that the lattice-parameters of the a axis, parallel to the sheets of Mg-O octahedra, decreases only slightly with pressure with no effect of H-D substitution. However, the c axis of Mg(OD)2 is shorter and decreases more rapidly than that of Mg(OH)2 with increasing pressure. Consequently, the unit-cell volume of deuterated brucite is slightly, but systematically smaller than that of normal brucite, which were fitted to third-order Birch-Murnaghan equation: K0=41.46 0.52 and 39.04 0.30 GPa for Mg(OH)2 and Mg(OD)2, respectively with a fixed K0 value of 10. Our results suggest that H-D substitution of brucite and other hydrous minerals with H-bonding likely influences their structural and dynamic properties under pressure, including the position of hydrogen atoms. The measured effect of H-D substitution on the unit-cell volume also demonstrates that brucite (and other hydrous minerals) preferentially incorporate deuterium over hydrogen under pressure, suggesting that the distribution of hydrogen isotopes in deep-earth conditions may differ significantly from that in near-surface environments.

08 HYDROGEN↗

Cancellation of environmental effects in resonant mass sensors based on resonance mode and effective mass

A novel technique is developed to cancel the effect of environmental parameters, e.g., temperature and humidity, in resonant mass sensing. Utilizing a single resonator, the environmental cancellation is achieved by monitoring a pair of resonant overtones and the effective sensed mass in those overtones. As an eminent advantage, especially compared to dual-mode temperature compensation techniques, the presented technique eliminates any need for previously measured look-up tables or fitting the measurement data. We show that a resonant cantilever beam is an appropriate platform for applying this technique, and derive an analytical expression to relate the actual and effective sensed masses on a cantilever beam. Thereby, it is shown that in applying the presented technique successfully, the effective sensed masses must not be the same in the investigated pair of resonance overtones. To prove the feasibility of the proposed technique, flexural resonance frequencies of a silicon cantilever are measured before and after loading with a strip of photoresist. Applying the presented technique shows significant reductions in influence of environmental parameters, with the temperature and humidity coefficients of frequency being improved from -19.5 to 0.2 ppm deg. C{sup -1} and from 0.7 to -0.03 ppm %RH{sup -1}, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the EMC effect in few-body nuclei at large x

Recent data on the EMC effect from Jefferson Lab experiment E03103 suggest that the nuclear dependence of the high x quark distribution may depend on the local nuclear environment, rather than being a purely bulk effect. We briefly discuss the analysis and results of the E03103 experiment focusing on the light nuclei and high x region. In addition, we also discuss a future experiment at the upgraded 12 GeV Jefferson Lab facility which will further investigate the role of the local nuclear environment and the influence of detailed nuclear structure on the modification of quark distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stokes' theorem, gauge symmetry and the time-dependent Aharonov-Bohm effect

Stokes' theorem is investigated in the context of the time-dependent Aharonov-Bohm effect—the two-slit quantum interference experiment with a time varying solenoid between the slits. The time varying solenoid produces an electric field which leads to an additional phase shift which is found to exactly cancel the time-dependent part of the usual magnetic Aharonov-Bohm phase shift. This electric field arises from a combination of a non-single valued scalar potential and/or a 3-vector potential. The gauge transformation which leads to the scalar and 3-vector potentials for the electric field is non-single valued. This feature is connected with the non-simply connected topology of the Aharonov-Bohm set-up. The non-single valued nature of the gauge transformation function has interesting consequences for the 4-dimensional Stokes' theorem for the time-dependent Aharonov-Bohm effect. An experimental test of these conclusions is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigating the impact of source/drain doping dependent effective masses on the transport characteristics of ballistic Si-nanowire field-effect-transistors

This article studies the impact of doping dependent carrier effective masses of the source/drain regions on transport properties of Si-nanowire field effect transistors within ballistic limit. The difference of carrier effective mass in channel and that in the source/drain regions leads to a misalignment of respective sub-bands and forms non-ideal contacts. Such non-idealities are incorporated by modifying the relevant self-energies which control the effective electronic transport from source to drain through the channel. Non-ideality also arises in the nature of local density of states in the channel due to sub-band misalignment, resulting to a reduction of drain current by almost 50%. The highest values of drain current, leakage current, and their ratio are obtained for the S/D doping concentrations of 3 × 10{sup 20} cm{sup −3}, 8 × 10{sup 20} cm{sup −3}, and 2 × 10{sup 20} cm{sup −3}, respectively, for the nanowire of length 10 nm and diameter of 3 nm. Interestingly, the maximum of sub-threshold swing, minimum of threshold voltage, and the maximum of leakage current are observed to be apparent at the same doping concentration.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nb-doped single crystalline MoS{sub 2} field effect transistor

We report on the demonstration of a p-type, single crystalline, few layer MoS{sub 2} field effect transistor (FET) using Niobium (Nb) as the dopant. The doping concentration was extracted and determined to be ∼3 × 10{sup 19}/cm{sup 3}. We also report on bilayer Nb-doped MoS{sub 2} FETs with ambipolar conduction. We found that the current ON-OFF ratio of the Nb-doped MoS{sub 2} FETs changes significantly as a function of the flake thickness. We attribute this experimental observation to bulk-type electrostatic effect in ultra-thin MoS{sub 2} crystals. We provide detailed analytical modeling in support of our claims. Finally, we show that in the presence of heavy doping, even ultra-thin 2D-semiconductors cannot be fully depleted and may behave as a 3D material when used in transistor geometry. Our findings provide important insights into the doping constraints of 2D materials, in general.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Photoacoustic effect generated by moving optical sources: Motion in one dimension

Although the photoacoustic effect is typically generated by pulsed or amplitude modulated optical beams, it is clear from examination of the wave equation for pressure that motion of an optical source in space will result in the production of sound as well. Here, the properties of the photoacoustic effect generated by moving sources in one dimension are investigated. The cases of a moving Gaussian beam, an oscillating delta function source, and an accelerating Gaussian optical sources are reported. The salient feature of one-dimensional sources in the linear acoustic limit is that the amplitude of the beam increases in time without bound.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hybrid quantum dot-tin disulfide field-effect transistors with improved photocurrent and spectral responsivity

We report an improved photosensitivity in few-layer tin disulfide (SnS 2 ) field-effect transistors(FETs) following doping with CdSe/ZnS core/shell quantum dots(QDs). The hybrid QD-SnS 2 FET devices achieve more than 500% increase in the photocurrent response compared with the starting SnS 2 -only FET device and a spectral responsivity reaching over 650 A/W at 400 nm wavelength. The negligible electrical conductance in a control QD-only FET device suggests that the energy transfer between QDs and SnS 2 is the main mechanism responsible for the sensitization effect, which is consistent with the strong spectral overlap between QDphotoluminescence and SnS 2 optical absorption as well as the large nominal donor-acceptor interspacing between QD core and SnS 2 . Furthermore, we also find enhanced charge carrier mobility in hybrid QD-SnS 2 FETs which we attribute to a reduced contact Schottky barrier width due to an elevated background charge carrier density.

36 MATERIALS SCIENCE↗

Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant Auger Effect at High X-Ray Intensity

The resonant Auger effect of atomic neon exposed to high-intensity x-ray radiation in resonance with the 1s {yields} 3p transition is discussed. High intensity here means that the x-ray peak intensity is sufficient ({approx} 10{sup 18} W/cm{sup 2}) to induce Rabi oscillations between the neon ground state and the 1s{sup -1}3p ({sup 1}P) state within the relaxation lifetime of the inner-shell vacancy. For the numerical analysis presented, an effective two-level model, including a description of the resonant Auger decay process, is employed. Both coherent and chaotic x-ray pulses are treated. The latter are used to simulate radiation from x-ray free-electron lasers based on the principle of self-amplified spontaneous emission. Observing x-ray-driven atomic population dynamics in the time domain is challenging for chaotic pulse ensembles. A more practical option for experiments using x-ray free-electron lasers is to measure the line profiles in the kinetic energy distribution of the resonant Auger electron. This provides information on both atomic population dynamics and x-ray pulse properties.

74 ATOMIC AND MOLECULAR PHYSICS↗

Voltage-Controlled Sensitivity of the Spin Seebeck Effect in Pt/Y 3 Fe 5 O 12 /MgO/(PbMg 1/3 Nb 2/3 O 3 ) 0.7 (PbTiO 3 ) 0.3 Multiferroic Heterostructures

The characteristics of pure spin current from the longitudinal spin Seebeck effect are investigated at room temperature in Pt / Y 3 Fe 5 O 12 deposited on the ( Pb Mg 1 / 3 Nb 2 / 3 O 3 ) 0.7 ( Pb Ti O 3 ) 0.3 substrate, through which electrostrain can be controllably applied. The applied voltage enables the modification of magnetic anisotropy in the magnetic insulating Y 3 Fe 5 O 12 layer, and thus the sensitivity of the spin Seebeck effect at small magnetic fields, without suppressing the spin Seebeck effect and the inverse spin Hall effect. This is due to the robust intrinsic physical parameters in Pt / Y 3 Fe 5 O 12 . In conclusion, our results pave the way for the application of voltage-controlled pure spin-current devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of radio transmitters on the behavior of Red-headed Woodpeckers.

ABSTRACT. Previous studies have revealed that radio-transmitters may affect bird behaviors, including feeding rates, foraging behavior, vigilance, and preening behavior. In addition, depending on the method of attachment, transmitters can potentially affect the ability of cavity-nesting birds to use cavities. Our objective was to evaluate effects of transmitters on the behavior of and use of cavities byRed-headedWoodpeckers (Melanerpes erythrocephalus). Using backpack harnesses, we attached 2.1-g transmitter packages that averaged 3.1% of body weight (range = 2.5–3.6%) to Red-headed Woodpeckers. We observed both radio-tagged (N = 23) and nonradio-tagged (N = 28) woodpeckers and determined the percentage of time spent engaged in each of five behaviors: flight, foraging, perching, preening, and territorial behavior. We found no difference between the two groups in the percentage of time engaged in each behavior. In addition, we found that transmitters had no apparent effect on use of cavities for roosting by radio-tagged woodpeckers (N = 25).We conclude that backpack transmitters weighing less than 3.6% of body weight had no impact on either their behavior or their ability to use cavities.

60 APPLIED LIFE SCIENCES↗

In Situ TEM Multi-Beam Ion Irradiation as a Technique for Elucidating Synergistic Radiation Effects

Materials designed for nuclear reactors undergo microstructural changes resulting from a combination of several environmental factors, including neutron irradiation damage, gas accumulation and elevated temperatures. Typical ion beam irradiation experiments designed for simulating a neutron irradiation environment involve irradiating the sample with a single ion beam and subsequent characterization of the resulting microstructure, often by transmission electron microscopy (TEM). This method does not allow for examination of microstructural effects due to simultaneous gas accumulation and displacement cascade damage, which occurs in a reactor. Sandia’s in situ ion irradiation TEM (I3TEM) offers the unique ability to observe microstructural changes due to irradiation damage caused by concurrent multi-beam ion irradiation in real time. This allows for time-dependent microstructure analysis. A plethora of additional in situ stages can be coupled with these experiments, e.g., for more accurately simulating defect kinetics at elevated reactor temperatures. This work outlines experiments showing synergistic effects in Au using in situ ion irradiation with various combinations of helium, deuterium and Au ions, as well as some initial work on materials utilized in tritium-producing burnable absorber rods (TPBARs): zirconium alloys and LiAlO2.

Taylor, Caitlin↗

Late Effects After Radiotherapy for Locally Advanced Cervical Cancer: Comparison of Two Brachytherapy Schedules and Effect of Dose Delivered Weekly

Purpose: To compare the severe late effects (Grade 3 or greater) for two groups of cervical cancer patients treated with the same external beam radiotherapy and two high-dose-rate intracavitary brachytherapy regimens and to investigate the influence of the dose delivered each week. Methods and Materials: For 120 patients, intracavitary brachytherapy was delivered with 33.6 Gy in eight fractions to Point A (HD group), and for 119, intracavitary brachytherapy was delivered with 29.4 Gy in seven fractions to Point A (LD group). The cumulative incidence of severe gastrointestinal and genitourinary late effects were calculated for both dose groups using Kaplan-Meier survival analysis. This method was also used to explore whether the number of weeks with different dose levels could predict the cumulative incidence of late effects. Results: The actuarial rate of developing severe gastrointestinal morbidity at 7 years was 10.7% and 8.3% for HD and LD groups, respectively. The rate for genitourinary morbidity was 6.6% for the HD group and 5.0% for the LD group, respectively. No significant difference was found between the two groups. The analyses showed that a marginally significant increase occurred in severe gastrointestinal complications as the number of weeks with a physical dose >20 Gy increased in the HD group (p = .047). Conclusion: To establish dose-response relationships for late complications, three-dimensional imaging and dose-volume histogram parameters are needed. We found some indications that 20 Gy/wk is an upper tolerance level when the dose to the International Commission on Radiation Units and Measurements rectum point is 81 Gy{sub {alpha}/{beta}=3} (isoeffective [equivalent] dose of 2-Gy fractions). However, additional investigations using three-dimensional data are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crossover Effects in Batteries with High–Nickel Cathodes and Lithium–Metal Anodes

It is well understood that cathode-to-anode crossover, especially of transition-metal ions, can significantly impact the long-term cycling of lithium-ion batteries. The dissolved transition-metal ions in lithium-ion cells deposit on the graphite anode, disrupt the solid-electrolyte interphase (SEI), and catalyze further side reactions. Meanwhile, crossover effects in lithium-metal batteries have rarely been studied. This study is the first to investigate crossover effects in lithium-metal batteries with high-nickel layered-oxide cathodes. It is shown that the crossover of transition-metal ions from LiNi 0.9 Mn 0.05 Co 0.05 O 2 has minimal effect on the lithium-metal anode (LMA) due to the following reasons. The catalytic transition metals 1) have less effect on an inherently reactive LMA, 2) are diluted in a thicker SEI, and 3) are produced in overall lower quantity due to the limited cycle life of the LMA. Conversely, the LMA generates soluble decomposition products that cross over to the cathode even during early cycling. This crossover accelerates impedance growth and capacity fade at the cathode and is partially responsible for the mismatch between the performance of half and full-cells with layered-oxide cathodes. Finally, this study highlights the need for better battery design with LMA, potentially including electrolyte or cell modifications.

25 ENERGY STORAGE↗

Size Effect of Negative Capacitance State and Subthreshold Swing in Van der Waals Ferrielectric Field–Effect Transistors

Analytical calculations corroborated by the finite element modeling show that thin films of Van der Waals ferrielectrics covered by a 2D-semiconductor are promising candidates for the controllable reduction of the dielectric layer capacitance due to the negative capacitance (NC) effect emerging in the thin films. The NC state is conditioned by energy-degenerated poly-domain states of the ferrielectric polarization induced in the films under incomplete screening conditions in the presence of a dielectric layer. Calculations performed for the FET-type heterostructure “ferrielectric CuInP 2 S 6 film—2D-MoS 2 single-layer—SiO 2 dielectric layer” reveal the pronounced size effect of the multilayer capacitance. Derived analytical expressions for the electric polarization and multilayer capacitance allow to predict the thickness range of the dielectric layer and ferrielectric film for which the NC effect is the most pronounced in various Van der Waals ferrielectrics, and the corresponding subthreshold swing becomes much less than the Boltzmann's limit. Obtained results can be useful for the size and temperature control of the NC effect in the steep-slope ferrielectric FETs.

36 MATERIALS SCIENCE↗

Dietary Selenomethionine Administration in the American Alligator ( Alligator mississippiensis ): Hepatic and Renal Se Accumulation and Its Effects on Growth and Body Condition

Selenium (Se) is an essential trace nutrient, but in excess, it can induce toxicity. Incomplete combustion of coal produces coal combustion wastes (CCWs), which are enriched in Se and often disposed of in aquatic basins. While a multitude of studies have investigated Se accumulation in vertebrates, there have been few studies examining its effects on longer-lived top trophic carnivores, such as the American alligator (Alligator mississippiensis). In this study, alligators were fed one of three Dietary Treatments: mice injected with water (controls) or water supplemented with 1000 ppm or 2000 ppm selenomethionine (SeMet). Dietary Treatment significantly affected Se levels in both the liver (p < 0.0001; raw mean ± standard error: 1000 ppm group, 35.20 ± 6.32 ppm; 2000 ppm group, 49.97 ± 4.00 ppm) and kidney (p < 0.0001; raw mean ± standard error: 1000 ppm group, 101.60 ± 8.64 ppm; 2000 ppm, 96.38 ± 5.81 ppm), which were significantly higher in alligators fed SeMet than in controls. Post-treatment head length (HL), used to control for size variation, was negatively related to both kidney (p = 0.0142) and liver (p = 0.0010) Se concentrations. Dietary Treatment with SeMet significantly reduced body condition (1000 ppm, p < 0.0029; 2000 ppm, p = 0.0075), but it significantly increased growth (1000 ppm, p < 0.0001; 2000 ppm, p = 0.0316). Body condition and growth remained unchanged in control alligators (p > 0.05). Our results demonstrate alligators are capable of accumulating high levels of Se through trophic transfer. Here, the positive effects of accumulation on growth may demonstrate Se essentiality, while the negative effects on condition may demonstrate toxicity. Accumulation was also associated with mortality, further demonstrating toxicity. Future studies should further investigate the physiological effects of Se accumulation in long-lived, top-trophic carnivores.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗