Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Medical, Psychophysiological, and Human Performance Problems During Extended EVA

In this session, Session JP1, the discussion focuses on the following topics: New Developments in the Assessment of the Risk of Decompression Sickness in Null Gravity During Extravehicular Activity; The Dynamic of Physiological Reactions of Cosmonauts Under the Influence of Repeated EVA Workouts, The Russian Experience; Medical Emergencies in Space; The Evolution from 'Physiological Adequacy' to 'Physiological Tuning'; Five Zones of Symmetrical and Asymmetrical Conflicting Temperatures on the Human Body, Physiological Consequences; Human Performance and Subjective Perception in Nonuniform Thermal Conditions; The Hand as a Control System, Implications for Hand-Finger Dexterity During Extended EVA; and Understanding the Skill of Extravehicular Mass Handling.

Source record↗

Two-Dimensional Finite Element Ablative Thermal Response Analysis of an Arcjet Stagnation Test

The finite element ablation and thermal response (FEAtR, hence forth called FEAR) design and analysis program simulates the one, two, or three-dimensional ablation, internal heat conduction, thermal decomposition, and pyrolysis gas flow of thermal protection system materials. As part of a code validation study, two-dimensional axisymmetric results from FEAR are compared to thermal response data obtained from an arc-jet stagnation test in this paper. The results from FEAR are also compared to the two-dimensional axisymmetric computations from the two-dimensional implicit thermal response and ablation program under the same arcjet conditions. The ablating material being used in this arcjet test is phenolic impregnated carbon ablator with an LI-2200 insulator as backup material. The test is performed at the NASA, Ames Research Center Interaction Heating Facility. Spatially distributed computational fluid dynamics solutions for the flow field around the test article are used for the surface boundary conditions.

Dec, John A.↗

Radial Profiles of Plasma Electron Characteristics in a Low-Power Arcjet

Since 1960, the Arc Jet Complex at NASA Ames Research Center has been a source of long-duration, high-enthalpy flow for materials testing with application to the thermal protection of aerospace vehicle components. From their inception the facilities have played an integral role supporting many of NASA's space flight programs and numerous DoD projects. In recent years advancements in computational fluid dynamics (CFO) have made the resultant models a valuable tool for assessing and predicting performance, however, the inherent limitation of models to compensate for a dissociated, transitionally high temperature nonequilibrated flowfield have made further measurements necessary. The use of electrostatic probe diagnostics within similarly harsh plasma environments in previous studies have been met with much success. In this study, the use of a single Langmuir probe was implemented to characterize the plasma parameters of interest as they vary radially within a large volume of the plume. Classical Langmuir probe theory was applied to achieve first order estimates of the heavy particle temperature, the ratio T(sub i)/T(sub e), and the ionization fraction. As expected, both the electron temperature and electron density measurements show a dependence on radial distance from the plume centerline, with electron density profiles showing the largest dependence. This paper aims to validate and strengthen modeling work conducted at the NASA Ames Research Center by measuring the critical plasma parameters (electron temperature, electron density, and plasma potential) within the arc plume of a subscale arc jet. These parameters are intended to give physical insight into the flow characteristics while providing the necessary boundary conditions to validate full scale simulations.

Codron, Douglas↗

Effect of Mass Transfer on Aeroheating in Hypersonic Chemically Reacting Boundary Layers

Heat flux characterization of high-enthalpy boundary layer flows is key to optimize the performance and design of Thermal Protection System of next generation aerospace vehicles [1]. At atmospheric entry hypersonic speeds, ablation as well as surface catalycity impact boundary layer aeroheating. Out-gassing occurring from an ablative surface in planetary entry environment introduces a rich set of problems in thermodynamic, fluid dynamic, and material pyrolysis. Ablation leads to out-gassing and surface roughness, both of which are known to affect surface heating in hypersonic chemically reacting boundary layers via three main routes: gas blowing into the boundary layer from the wall, changing the surface heat transfer due to wall-flow chemical reactions, and modifying surface roughness via ablative processes.

Karimi, Mona↗

High Efficiency Megawatt Motor Stator Thermal Performance

Enabling single aisle electric aircraft propulsion requires power dense, megawatt scale, high efficiency electric machines. To that end NASA has been developing the High Efficiency Megawatt Motor (HEMM) 1.46 MW (16kW/kg), 98% efficient electric machine. The success of this effort is highly dependent on the stator’s thermal (cooling) design. The design to date has been based upon computation fluid dynamic and finite element analysis models that have been validated with testing of stator sub sections that replicate expected thermal conditions. However, the test to validate the model can only be so accurate without fully representing the full geometry and components of the stator. A full HEMM stator has been fabricated, potted, and installed in a housing complete with vacuum tube. This apparatus was used to validate the full thermal environment of HEMM and act as a final validation of the stator design before fully fabricating the machine. This paper discusses the modeling and test results from this penultimate HEMM stator build.

electric machine↗

Some space shuttle tile/strain-isolator-pad sinusoidal vibration tests

Vibration tests were performed on the tile/strain-isolator-pad system used as thermal protection for the space shuttle orbiter. Experimental data on normal and in-plane vibration response and damping properties are presented. Three test specimens exhibited shear type motion during failures that occurred in the tile near the tile/strain-isolator-pad bond-line. A dynamic instability is described which has large in-plane motion at a frequency one-half that of the nominal driving frequency. Analysis shows that this phenomenon is a parametric response.

Miserentino, R.↗

Structural Design of a 4-Meter Off-Axis Space Telescope for the Habitable-Zone Exoplanet Direct Imaging Mission

This design study was conducted to support the HABEX project. There are a number of companion papers at this conference which go into detail on what all the HABEX goals are. The objective of this paper is to establish a baseline primary mirror design which satisfies the following structural related requirements. The designs in this study have a high TRL (Technology Readiness Level), realistic manufacturing limits and performance in line with the HABEX mission. A secondary goal of the study was to evaluate a number competing criteria for the selection. Questions such as differences in the on axis versus off axis static and dynamic response to disturbances. This study concentrates on the structural behavior, companion papers cover thermal and long term stability aspects of the problem.

Habitable-zone Exoplanet Direct Imaging Mission↗

Turbine Electrified Energy Management (TEEM) For Enabling More Efficient Engine Designs

NASA is investing in Electrified Aircraft Propulsion (EAP) research as part of an effort to assist industry in meeting the future needs of a global aviation market. The integration of electric machines into traditional turbine-based propulsion provides opportunities to change system architectures effecting radical improvements in propulsive efficiency. However, less consideration has been afforded to the utilization of these electrical machines to improve the thermal efficiency and performance of the gas turbine engine. Noting this deficit, a novel operability concept is proposed and is referred to as Turbine Electrified Energy Management (TEEM). The concept is a transient control technology that supplements the main fuel control for the suppression of the natural off-design dynamics associated with changes in engine operating state. Here the electric machines, used as engine actuators during the transient, add or extract torque from the engine shafts to maintain the speed-flow characteristics of steady-state design operation. This greatly reduces the need to maintain transient stall margin stack in the compressors, among other potential benefits. This paper demonstrates the feasibility of the concept in dynamic simulation using a Numerical Propulsion System Simulation (NPSS) engine model of a NASA hybrid electric propulsion concept known as the Parallel Hybrid Electric Turbofan (hFan).

Culley, Dennis E.↗

Performance of a mullite reusable surface insulation system in a hypersonic stream

The thermal and structural performance of a large panel of mullite reusable surface insulation (RSI) tiles was determined by a series of aerothermal tests in the Langley 8-foot high-temperature structures tunnel. The test panel was designed to represent a portion of the surface structure on a space shuttle orbiter fuselage along a 1,150 K isotherm with the mullite tile system bonded directly to the primary structure. Aerothermal tests were conducted at a free-stream Mach number of 6.7, a total temperature of 1,880 K, a unit Reynolds number of 4.6 million per meter, and dynamic pressure of 62 kPa. The thermal response of the mullite tile was as predicted, and the bond-line temperature did not exceed the design level of 570 K during a typical entry-heat cycle. Geometric irregularities of the tile gaps affected the tile edge temperatures when exposed to hypersonic flow. The tile coating demonstrated good toughness to particle impacts, but the coating cracked and flaked with thermal cycles. The gap filler of woven silica fibers appeared to hinder flow penetration into the gaps and withstood the flow shear of the present tests.

Hunt, L. R.↗

Engine management during NTRE start up

The topics are presented in viewgraph form and include the following: total engine system management critical to successful nuclear thermal rocket engine (NTRE) start up; NERVA type engine start windows; reactor power control; heterogeneous reactor cooling; propellant feed system dynamics; integrated NTRE start sequence; moderator cooling loop and efficient NTRE starting; analytical simulation and low risk engine development; accurate simulation through dynamic coupling of physical processes; and integrated NTRE and mission performance.

Bulman, Mel↗

Refractive Secondary Concentrators for Solar Thermal Applications

The NASA Glenn Research Center is developing technologies that utilize solar energy for various space applications including electrical power conversion, thermal propulsion, and furnaces. Common to all of these applications is the need for highly efficient, solar concentration systems. An effort is underway to develop the innovative single crystal refractive secondary concentrator, which uses refraction and total internal reflection to efficiently concentrate and direct solar energy. The refractive secondary offers very high throughput efficiencies (greater than 90%), and when used in combination with advanced primary concentrators, enables very high concentration ratios (10,0(X) to 1) and very high temperatures (greater than 2000 K). Presented is an overview of the refractive secondary concentrator development effort at the NASA Glenn Research Center, including optical design and analysis techniques, thermal modeling capabilities, crystal materials characterization testing, optical coatings evaluation, and component testing. Also presented is a discussion of potential future activity and technical issues yet to be resolved. Much of the work performed to date has been in support of the NASA Marshall Space Flight Center's Solar Thermal Propulsion Program. The many benefits of a refractive secondary concentrator that enable efficient, high temperature thermal propulsion system designs, apply equally well to other solar applications including furnaces and power generation systems such as solar dynamics, concentrated thermal photovoltaics, and thermionics.

Wong, Wayne A.↗

The Response of the Ionospheric Cusp to the Solar Through Two Perspectives: Low Energy Changed Particle In-Situ Measurements and Low- Energy Neutral Atom Imaging

The IMAGE mission provides a new perspective on the study of the response of the magnetosphere/ionosphere system to changing solar wind conditions, particularly the variability of ion outflow. Learning to interpret this new type of data becomes an essential step in the process of melding these results with the wealth of in-situ charged particle observations obtained over the past 25 years. In order to understand how the in-situ data correspond to and contrast with IMAGE results we will perform a conjunctive study of event data from two instruments to shed light on the coupling of the solar wind and ionosphere from these different perspectives. We will use the Low Energy Neutral Atom instrument (LENA) which images energetic neutral atom emissions from upward flowing ionospheric ions and the Thermal Ion Dynamics Instrument (TIDE) on the Polar satellite which measures in-situ ion outflow from 0.3-300 eV. Our primary goal will be to understand how comparing the imaging and in-situ perspectives can aid in the analysis of both data sets.

Coffey, V. N.↗

The Response of the Ionospheric Cusp to the Solar Wind Through Two Perspectives: Low Energy Charged Particle In-Situ Measurements and Low-Energy Neutral Atom Imaging

The Imager for Magnetopause-to-Aurora Global Exploration (IMAGE) mission provides a new perspective on the study of the response of the magnetosphere/ionosphere system to changing solar wind conditions, particularly the variability of ion outflow. Learning to interpret this new type of data becomes an essential step in the process of melding these results with the wealth of in-situ charged particle observations obtained over the past 25 years. In order to understand how the in-situ data correspond to and contrast with IMAGE results we will perform a conjunctive study of event data from two instruments to shed light on the coupling of the solar wind and ionosphere from these different perspectives. We will use the Low Energy Neutral Atom instrument (LENA) which images energetic neutral atom emissions from upward flowing ionospheric ions and the Thermal Ion Dynamics Instrument (TIDE) on the Polar satellite which measures in-situ ion outflow from 0.3-300 eV. Our primary goal will be to understand how comparing the imaging and in-situ perspectives can aid in the analysis of both data sets.

Coffey, V. N.↗

Efficient computerized model for dynamic analysis of energy conversion systems

In searching for the optimum parameters that minimize the total life cycle cost of an energy conversion system, various combinations of components are examined and the resulting system performance and associated economics are studied. The systems performance and economics simulation computer program (SPECS) was developed to fill this need. The program simulates the fluid flow, thermal, and electrical characteristics of a system of components on a quasi-steady state basis for a variety of energy conversion systems. A unique approach is used in which the set of characteristic equations is solved by the Newton-Raphson technique. This approach eliminates the tedious iterative loops which are found in comparable programs such as TRNSYS or SOLTES-1. Several efficient features were also incorporated such as the centralized control and energy management scheme, and analogous treatment of energy flow in electrical and mechanical components, and the modeling of components of similar fundamental characteristics using generic subroutines. Initial tests indicate that this model can be used effectively with a relatively small number of time steps and low computer cost.

Hughes, R. D.↗

Development of procedures for calculating stiffness and damping properties of elastomers in engineering applications. Part 2: Elastomer characteristics at constant temperature

Dynamic properties of a commerical polybutadiene compound were determined at a constant temperature of 32 C by a forced-vibration resonant mass type of apparatus. The constant thermal state of the elastomer was ensured by keeping the ambient temperature constant and by limiting the power dissipation in the specimen. Experiments were performed with both compression and shear specimens at several preloads (nominal strain varying from 0 to 5 percent), and the results are reported in terms of a complex stiffness as a function of frequency. Very weak frequency dependence is observed and a simple power law type of correlation is shown to represent the data well. Variations in the complex stiffness as a function of preload are also found to be small for both compression and shear specimens.

Gupta, P. K.↗

800 Hours of Operational Experience from a 2 kW(sub e) Solar Dynamic System

From December 1994 to September 1998, testing with a 2 kW(sub e) Solar Dynamic power system resulted in 33 individual tests, 886 hours of solar heating, and 783 hours of power generation. Power generation ranged from 400 watts to over 2 kW(sub e), and SD system efficiencies have been measured up to 17 per cent, during simulated low-Earth orbit operation. Further, the turbo-alternator-compressors successfully completed 100 start/stops on foil bearings. Operation was conducted in a large thermal/vacuum facility with a simulated Sun at the NASA Lewis Research Center. The Solar Dynamic system featured a closed Brayton conversion unit integrated with a solar heat receiver, which included thermal energy storage for continuous power output through a typical low-Earth orbit. Two power conversion units and three alternator configurations were used during testing. This paper will review the test program, provide operational and performance data, and review a number of technology issues.

Shaltens, Richard K.↗

Brayton Power Conversion Unit Tested: Provides a Path to Future High-Power Electric Propulsion Missions

Closed-Brayton-cycle conversion technology has been identified as an excellent candidate for nuclear electric propulsion (NEP) power conversion systems. Advantages include high efficiency, long life, and high power density for power levels from about 10 kWe to 1 MWe, and beyond. An additional benefit for Brayton is the potential for the alternator to deliver very high voltage as required by the electric thrusters, minimizing the mass and power losses associated with the power management and distribution (PMAD). To accelerate Brayton technology development for NEP, the NASA Glenn Research Center is developing a low-power NEP power systems testbed that utilizes an existing 2- kWe Brayton power conversion unit (PCU) from previous solar dynamic technology efforts. The PCU includes a turboalternator, a recuperator, and a gas cooler connected by gas ducts. The rotating assembly is supported by gas foil bearings and consists of a turbine, a compressor, a thrust rotor, and an alternator on a single shaft. The alternator produces alternating-current power that is rectified to 120-V direct-current power by the PMAD unit. The NEP power systems testbed will be utilized to conduct future investigations of operational control methods, high-voltage PMAD, electric thruster interactions, and advanced heat rejection techniques. The PCU was tested in Glenn s Vacuum Facility 6. The Brayton PCU was modified from its original solar dynamic configuration by the removal of the heat receiver and retrofitting of the electrical resistance gas heater to simulate the thermal input of a steady-state nuclear source. Then, the Brayton PCU was installed in the 3-m test port of Vacuum Facility 6, as shown. A series of tests were performed between June and August of 2002 that resulted in a total PCU operational time of about 24 hr. An initial test sequence on June 17 determined that the reconfigured unit was fully operational. Ensuing tests provided the operational data needed to characterize PCU performance over its full operating range. The primary test variables used in operating the Brayton PCU were heater input power and rotor speed. Testing demonstrated a maximum steady-state alternating-current power output of 1835 W at a gas heater power of 9000 W and a rotor speed of 52000 rpm. The corresponding measured turbine inlet gas temperature was 1076 K, and the compressor inlet gas temperature was 282 K. When insulation losses from the gas heater were neglected, the Brayton cycle efficiency for the maximum power point was calculated to be 24 percent. The net direct-current power output was 1750 W, indicating a PMAD efficiency of about 95 percent.

Mason, Lee S.↗

Improved Dynamic Modeling of the Cascade Distillation Subsystem and Analysis of Factors Affecting Its Performance

The Cascade Distillation Subsystem (CDS) is a rotary multistage distiller being developed to serve as the primary processor for wastewater recovery during long-duration space missions. The CDS could be integrated with a system similar to the International Space Station Water Processor Assembly to form a complete water recovery system for future missions. A preliminary chemical process simulation was previously developed using Aspen Custom Modeler® (ACM), but it could not simulate thermal startup and lacked detailed analysis of several key internal processes, including heat transfer between stages. This paper describes modifications to the ACM simulation of the CDS that improve its capabilities and the accuracy of its predictions. Notably, the modified version can be used to model thermal startup and predicts the total energy consumption of the CDS. The simulation has been validated for both NaC1 solution and pretreated urine feeds and no longer requires retuning when operating parameters change. The simulation was also used to predict how internal processes and operating conditions of the CDS affect its performance. In particular, it is shown that the coefficient of performance of the thermoelectric heat pump used to provide heating and cooling for the CDS is the largest factor in determining CDS efficiency. Intrastage heat transfer affects CDS performance indirectly through effects on the coefficient of performance.

Perry, Bruce A.↗