Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Dynamic Modeling and Characterization of Nuclear-grade Graphite

Idaho National Labs serves as the spearhead for many innovative energy solutions to the world's energy crisis. One such solution is the INL's Microreactor which is designed to deploy to extreme/remote environments where other sources of power are either unavailable or unreliable. In order to best design these energy solutions for their operational environments, it is crucial to understand how the design, components, and materials will respond to the environmental conditions. One key material in these innovative designs is a nuclear-grade graphite known as PCEA. This study examines the behavior of PCEA graphite under dynamic loading, similar to that which may occur in extreme environments. The objective is to characterize the dynamic behavior and produce an accurate, reliable constitutive model suitable for use in simulation tools such as INL's MOOSE. Graphite specimens were tested using a Split Hopkinson Pressure Bar (SHPB) to administer the dynamic compressive load. The SHPB was charged at various pressures to produce a range of strain rates on the material in compression. Data was acquired via strain gauges on the SHPB setup, from which stress, strain, and time data were collected. Analysis revealed the stress-strain behavior of the material as well as insights into the material behavior's relationship to strain rate. Further work must continue to characterize the various other dynamic behaviors of the material which will combine to create a substantially trustworthy constitutive model for this grade of nuclear-grade graphite. Ultimately, this will allow for realistic simulation of the material in reactor designs, allowing for prediction of design weaknesses and leading to improved designs for increased resilience, security, and reliability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimating Material Properties Under Extreme Conditions by Using Bayesian Model Calibration with Functional Outputs

Summary Dynamic material properties experiments provide access to the most extreme temperatures and pressures attainable in a laboratory setting; the data from these experiments are often used to improve our understanding of material models at these extreme conditions. We apply Bayesian model calibration to dynamic material property applications where the experimental output is a function: velocity over time. This framework can accommodate more uncertainties and facilitate analysis of new types of experiments relative to techniques traditionally used to analyse dynamic material experiments. However, implementation of Bayesian model calibration requires more sophisticated statistical techniques, because of the functional nature of the output as well as parameter and model discrepancy identifiability. We propose a novel Bayesian model calibration process to simplify and improve the estimation of the material property calibration parameters. Specifically, we propose scaling the likelihood function by an effective sample size rather than modelling the auto-correlation function to accommodate the functional output. Additionally, we propose sensitivity analyses by using the notion of 'modularization' to assess the effect of experiment-specific nuisance input parameters on estimates of the physical parameters. The Bayesian model calibration framework proposed is applied to dynamic compression of tantalum to extreme pressures, and we conclude that the procedure results in simple, fast and valid inferences on the material properties for tantalum.

36 MATERIALS SCIENCE↗

Rapid activation of non-oriented mechanophores via shock loading and spallation

Mechanophores (MPs), stimuli-responsive molecules that respond chromatically to mechanochemical reactions, are important for understanding the coupling between mechanics and chemistry as well as in engineering applications. However, the atomic-level understanding of their activation originates from gas phase studies or under simple linear elongation forces directly on molecules or polymer chains containing MPs. The effect of many-body distortions, pervasive in condensed-phase applications, is not understood. Therefore, we performed large-scale molecular dynamics (MD) simulations of a poly(methyl methacrylate)-spiropyran copolymer under dynamic mechanical loading and studied the activation of the MP under various conditions from dynamical compression to tension during unloading. Detailed analysis of the all-atom MD trajectories shows that the MP blocks experience significant many-body intramolecular distortion that can significantly decrease the activation barrier as compared with when deformation rates are slow relative to molecular relaxation time scales. Here we find that the reactivity of MPs under material compression states is governed by many-body effects of intramolecular torsions, whereas under tension, the reactions are governed by tensile stresses.

36 MATERIALS SCIENCE↗

X-ray radiography and scattering diagnosis of dense shock-compressed matter

Highly coupled Boron plasma has been probed by spectrally resolving an x-ray source scattered by the plasma. Electron density was inferred from the inelastic feature in the collective scattering regime. In addition, the mass density inferred from the noncollective x-ray Thomson scattering has been tested with independent characterization using x-ray radiography in the same drive condition. High-intensity laser produced K-alpha radiation was used as a backlighter for these dynamically compressed plasma experiments providing a high temporal resolution of the measurements. Mass density measurements from both methods are in good agreement. The measurements yield a compression of 1.3 in agreement with detailed radiation-hydrodynamic modeling. From the charge state measured in the noncollective regime and the electron density measured in the collective regime mass density can then be constrained to 3.15+-0.7.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Radiography and Scattering Diagnosis of Dense Shock-Compressed Matter

Highly coupled Boron plasma has been probed by spectrally resolving an x-ray source scattered by the plasma. Electron density was inferred from the inelastic feature in the collective scattering regime. In addition, the mass density inferred from the non-collective X-ray Thomson scattering has been tested with independent characterization using X-ray radiography in the same drive condition. High-intensity laser produced K-alpha radiation was used as a backlighter for these dynamically compressed plasma experiments providing a high temporal resolution of the measurements. Mass density measurements from both methods are in good agreement. The measurements yield a compression of 1.3 in agreement with detailed radiation-hydrodynamic modeling. From the charge state measured in the non-collective regime and the electron density measured in the collective regime the mass density can then be constrained to 3.15 {+-} 0.16.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a novel mid-infrared pyrometer for dynamic material experiments

Temperature is a complicated thermodynamic parameter to measure in dynamic compression experiments. Optical pyrometry is a general-purpose “work-horse” technique for measuring temperature from a radiant surface on these experimental platforms. The optical pyrometry channels are commonly held to the visible or Near-Infrared spectrum, which provides high fidelity temperature measurement for shock temperature above ∼1200–1500 K. However, low temperature (T < 1200 K) dynamic material experiments, including low pressure or quasi-isentropic studies, as well as experiments with complex thermodynamic paths, require Mid-Infrared (Mid-IR) for high fidelity measurements. This article outlines the design, testing, and characterization of a novel Mid-IR pyrometer system that can be configured between 2.5 and 5.0 µm, suitable for lower temperature measurements and for increasing the fidelity and precision of higher temperature measurements. Experimental validation was done on two separate gas gun platforms, with two separate impact velocities, achieving temperatures between 450 and 1100 K.

Dutra, E. C. (ORCID:0000000167649195)↗

Shock compression of additively manufactured high solids loaded polymer composites with aligned porosity

The effects of aligned porosity on the shock-compression response of additively manufactured (AM) composite structures with collinear and log-cabin geometries are investigated. The composites contain two inorganic and two organic particle populations and a UV-curable polymer binder. X-ray phase contrast imaging (X-PCI) is used as an in-material diagnostic in plate-impact experiments performed at the Dynamic Compression Sector of the Advanced Photon Source at the Argonne National Laboratory. Macroscale shock and particle velocities and microscale pore collapse velocities are measured from X-PCI images obtained from samples impacted in various orientations relative to the AM build directions. The linear shock and particle velocity relation for the structures with collinear build geometry shows directional differences, with the build direction exhibiting the highest slope and the filament print direction having the shallowest slope. Composites with log-cabin geometry, due to their slightly lower porosity and smaller sized pores, show higher shock velocities than the collinear structures at the same particle velocity. Microscale directionality effects are also observed, with the pore collapse velocity dependent on the pore configuration. Specifically, the pore collapse velocity is highest for pores elongated along the impact direction which is the case for the colinear structures impacted in the filament print direction, which is consistent with the directionality trend observed in the data for the shock and particle velocity equation of state. The pore collapse velocity approaches ∼80 % of the shock velocity and is several times the average bulk particle velocity, suggesting a highly hydrodynamic mechanism of pore collapse. Overall, both the macroscale response as measured by the shock and particle velocity relationship, and the microscale response as measured by the pore collapse velocity, are found to be anisotropic and dependent on the AM composite structure.

Wagner, K. B. [Georgia Institute of Technology, At↗

Dynamic crystal rotation resolved by high-speed synchrotron X-ray Laue diffraction

Dynamic compression experiments are performed on single-crystal Si under split Hopkinson pressure bar loading, together with simultaneous high-speed (250–350 ns resolution) synchrotron X-ray Laue diffraction and phase-contrast imaging. A methodology is presented which determines crystal rotation parameters, i.e. instantaneous rotation axes and angles, from two unindexed Laue diffraction spots. Two-dimensional translation is obtained from dynamic imaging by a single camera. High-speed motion of crystals, including translation and rotation, can be tracked in real time via simultaneous imaging and diffraction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamic fracture behavior of single and contacting Poly(methyl methacrylate) particles

Fracture behaviors of single, two, and multiple contacting spherical Poly (methyl methacrylate) (PMMA) particles were recorded using high speed synchrotron X-ray phase contrast imaging. A miniaturized Kolsky bar setup was used to apply dynamic compressive loading on the PMMA particles. In both single and two particle experiments, cracking initiated near the center of the particles and propagated towards the contacts. The crack bifurcated near the contact points for single particle experiments, thus forming conical fragments. The crack bifurcation and subsequent conical fragment formation was observed only at the particle-particle contact for two particle experiments. The particles were observed to fracture in hemispherical fragments normal to the contact plane in the multiparticle experiments. The observed failure mechanisms strongly suggest that the maximum tensile stress near the center of the particle is the critical parameter governing fracture of the particles. Moreover, the compressive stress under the contact areas led to the bifurcation and subsequent conical fragment formation.

36 MATERIALS SCIENCE↗

Impact system for ultrafast synchrotron experiments

The impact system for ultrafast synchrotron experiments, or IMPULSE, is a 12.6-mm bore light-gas gun (<1 km/s projectile velocity) designed specifically for performing dynamic compression experiments using the advanced imaging and X-ray diffraction methods available at synchrotron sources. The gun system, capable of reaching projectile velocities up to 1 km/s, was designed to be portable for quick insertion/removal in the experimental hutch at Sector 32 ID-B of the Advanced Photon Source (Argonne, IL) while allowing the target chamber to rotate for sample alignment with the beam. A key challenge in using the gun system to acquire dynamic data on the nanosecond time scale was synchronization (or bracketing) of the impact event with the incident X-ray pulses (80 ps width). A description of the basic gun system used in previous work is provided along with details of an improved launch initiation system designed to significantly reduce the total system time from launch initiation to impact. Experiments were performed to directly measure the gun system time and to determine the gun performance curve for projectile velocities ranging from 0.3 to 0.9 km/s. All results show an average system time of 21.6 {+-} 4.5 ms, making it possible to better synchronize the gun system and detectors to the X-ray beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equation of State and Damage in Polyethylene

The dynamic response of polymers differs significantly from those of metals, upon which many of the National Laboratories' deformation, damage, and failure models are based. Their moduli, yield strength, and damage characteristics are highly strain rate-, temperature-, and phase-dependent, requiring models that encompass a wide range of phenomena including some not in equilibrium. Recently, Los Alamos developed the Glassy Amorphous Polymer (GAP) 1 model [1] to address limitations in existing models of polymer deformation. GAP captures both volumetric (equation of state) and deviatoric (shear) response, including a non-equilibrium component to the former (a feature determined to be crucial in capturing the low-pressure, viscoelastic response to impact loading). GAP has already been applied to polymers such as PMMA, PTFE, epoxy, and Kel-F 800, but with an emphasis on impact response as opposed to damage or failure. The current effort was launched to address this gap in predictive capability. For reasons that will be made clear, semi-crystalline polyethylene (PE) was chosen to serve as a model system for parameterization and validation. PE (-C 2 H 4- )n is one of the most widely used polymers in industrial and engineering contexts, chiey due to the versatility of its mechanical response. This response can be tuned through network and chain structure, degree of crystallinity, and molecular weight. PE is found in several forms including low density (LDPE), high density (HDPE), and ultra-high molecular weight (UHMWPE). The focus here was on HDPE and UHMWPE, of pedigree described in the following section. Materials were well-characterized prior to study and are representative of semi-crystalline polymers of interest to DOE and DoD. Semi-crystalline PE undergoes a glass transition at low temperature (-35°C) and melts across a range of moderate temperatures (~80-180°C), depending on its structure. It is typically inert chemically, has low strength and high ductility, and the high strength and anisotropy of UHMWPE ber, in particular, have driven its use in engineering, impact, and armor applications. Surprisingly little is known, however, about the influence of PE's crystalline structure and associated phase transitions (including melt) on its response to dynamic compression. A broad suite of experiments was used to calibrate the GAP model for HDPE and UHMWPE. Section IV examines the effects of tensile strain on the structure and integrity of PE crystalline domains. These data were used to inform the preliminary damage model described in Section XII, whose roots lie in statistical physics and network theory. The viscoelastic and plastic components of GAP rely heavily on the stress-strain data of Section VI, which also include dynamic extrusion and Taylor anvil experiments used to validate the damage model. The thermal data of Section X provide crucial inputs to the equilibrium EOS in GAP, as well as the much broader range SESAME EOS whose construction is outlined in Section XI. Section VII details plate impact experiments characterizing the low-pressure shock locus and failure (spall) using in situ electromagnetic gauges. A previously reported \cusp" in the principal Hugoniot near 0.5 kbar was confirmed, and a multi-wave structure was observed over a limited input stress range above the cusp. This cusp is believed due to solid-solid phase transitions associated with the crystalline domains of the polymer.

36 MATERIALS SCIENCE↗

Investigation of compression of indirect-drive targets under conditions of the NIF facility using one-dimensional modelling

The indirect compression dynamics of targets containing capsules with ablators of a plastic, high-density carbon and beryllium is simulated in the framework of a one-dimensional model based on the 1D RADIAN code. Experiments with such targets are performed on the NIF facility in the Livermore Laboratory (USA) in 2014 – 2018. The 1D simulation data are consistent with the results of experiments and calculations made at this Laboratory. The effect of the hard part of hohlraum radiation on capsule compression parameters is confirmed. We demonstrate the feasibility of eliminating this influence not only by selecting the hohlraum material but also by introducing admixtures into the capsule that absorb this radiation. It is shown how varying the amount of admixture in the capsule ablator varies the spectrum of the radiation that heats the DT fuel. (interaction of laser radiation with matter. laser plasma)

36 MATERIALS SCIENCE↗

Experimental Pathways for Detecting Double Superionicity in Planetary Ices

The ice giant planets Uranus and Neptune are assumed to contain large amounts of planetary ices such as water, methane, and ammonia. The properties of mixtures of such ices at the extreme pressures and temperatures of planetary interiors are not yet well understood. Ab initio computer simulations have predicted that a number of ices exhibit a hydrogen superionic state and a doubly superionic state. Since the latter state has not yet been generated with experiments, we outline here two possible pathways for reaching and detecting such a state with dynamic compression experiments. Here, we suggest X-ray diffraction as the principal tool for detecting when the material becomes doubly superionic and the sublattice of one of the heavy nuclei melts. That would require a temperature of ~3500 K and pressures greater than ~200 GPa for H 3 NO 4 , which we use as an example material here. Such conditions can be reached with experiments that employ an initial shock that is followed by a ramp compression wave. Alternatively, one may use triple-shock compression because a single shock does not yield sufficiently high densities.

Neptune↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure-temperature equation of state of Al 2 ⁢O 3 up to 14 Mbar and 40 kK

Sapphire (Al 2 ⁢O 3 ), known for its remarkable incompressibility at ambient conditions, plays a pivotal role in both static and dynamic compression research. Accurately characterizing its equation of state (EoS) is essential for these applications. Here, we present a complete Hugoniot of Al 2 ⁢ O 3 as locus of experimentally assessed, high-precision, pressure, density and temperature states up to 14 Mbar and 43 kK. The Hugoniot is established with single shock experiments using magnetically launched hyper velocity flyers on the Z Accelerator at Sandia National Laboratories. We explore principal Hugoniot states at very high shock 𝑇 and 𝑝 in the solid phase, tracking the solid-liquid boundary and culminating at 2.4-fold compression, where data provides a direct constraint on the liquid phase. Corresponding shock release data probe thermodynamic states complementary to the Hugoniot and place additional constraints on tabular EoS models. Our findings indicate a significant deviation from existing tabular EoS models for Al 2 ⁢ O 3 dictating a comprehensive overhaul. We develop two advanced EoSs for Al 2 ⁢ O 3 the SESAME 97412 model, featuring an extensive phase diagram that includes three solid phases and the liquid phase, and the updated LEOS 2200m2 model. EoS development is assisted with Quantum Molecular Dynamics simulations. Our experimental data allows for stringent testing of our EoSs. Both models accurately capture the Hugoniot of Al 2 ⁢O 3 up to the highest pressures and temperatures. Rigorous experimental determination of extreme pressures and temperatures, paired with sophisticated models, advances the frontier of EoS development beyond 1 terapascal.

Kalita, Patricia [Sandia National Laboratories (SN↗

Anisotropy-driven collisional separation of impurities in magnetized compressing and expanding cylindrical plasmas

When a cylindrically-symmetric magnetized plasma compresses or expands, velocity-space anisotropy is naturally generated as a result of the different adiabatic conservation laws parallel and perpendicular to the magnetic field. When the compression timescale is comparable to the collision timescale, and both are much longer than the gyroperiod, this pressure anisotropy can become significant. We show that this naturallygenerated anisotropy can dramatically affect the transport of impurities in the compressing plasma, even in the absence of scalar temperature or density gradients, by modifying the azimuthal frictions that give rise to radial particle transport. Although the impurity transport direction depends only on the sign of the pressure anisotropy, the anisotropy itself depends on the pitch magnitude of the magnetic field and the sign of the radial velocity. Thus, pressure anisotropy effects can drive impurities either towards or away from the plasma core. These anisotropy-dependent terms represent a qualitatively new effect, influencing transport particularly in the sparse edge regions of dynamically-compressing screw pinch plasmas. Such plasmas are used for both X-ray generation and magneto-inertial fusion, applications which are sensitive to impurity concentrations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single crystal toroidal diamond anvils for high pressure experiments beyond 5 megabar

Static compression experiments over 4 Mbar are rare, yet critical for developing accurate fundamental physics and chemistry models, relevant to a range of topics including modeling planetary interiors. Here we show that focused ion beam crafted toroidal single-crystal diamond anvils with ~9.0 μm culets are capable of producing pressures over 5 Mbar. The toroidal surface prevents gasket outflow and provides a means to stabilize the central culet. We have reached a maximum pressure of ~6.15 Mbar using Re as in situ pressure marker, a pressure regime typically accessed only by double-stage diamond anvils and dynamic compression platforms. In conclusion, optimizing single-crystal diamond anvil design is key for extending the pressure range over which studies can be performed in the diamond anvil cell.

36 MATERIALS SCIENCE↗