Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Recommended Actions to Improve Adapter Safety

With the rapid advancement and acceleration in the electric vehicle (EV) industry within the United States, major automakers and EV charging companies are increasingly adopting the North American Charging Standard (NACS) connector style, now officially known as J3400. This shift is expected to enhance charging infrastructure, providing a better customer experience by making it easier for all EV drivers to access a wider network of direct-current (DC) fast chargers (DCFCs). However, the adoption of the J3400 standard presents challenges for many EVs already on the roads and some currently coming off production lines that are equipped with the Combined Charging System (CCS) connector, which this report will refer to as the North American standard, CCS1. These vehicles will need adapters to use new or existing J3400 infrastructure. During this transition, several issues have emerged. Firstly, there is a need to standardize the new connector type to ensure it is interoperable, safe, and reliable. Second, existing CCS EV drivers need a way to access the J3400 network, which will require electric vehicle supply equipment (EVSE) or sites with both connector types, driver-provided adapters to physically convert from CCS to J3400, or EVSE with retained adapters designed for use with the EVSE. Third, adapter standards will need to be written to specify how they will be designed and what evaluations will be needed to ensure safe and reliable performance. To address these challenges, adapters that support different types of charging connectors will be essential. These adapters will play a crucial role in supporting the transition and ensuring continued service for legacy EVs with CCS inlets as the J3400 standard becomes the predominant one in the United States. Consequently, the National Charging Experience (ChargeX) Consortium has investigated and performed a teardown analysis on the different adapter versions on the market. The aim is to create a failure mode and effects analysis (FMEA) on what are expected to be the most common adapter types used in this transition. In order to support this work, we executed an FMEA exercise with the main goal of identifying gaps in the existing adapters' performance and conformance to the most common safety requirements of high-power and high-voltage devices. This effort focused on adapters provided by the driver, as these may present the highest safety and reliability risks. The recommendations made here apply to both retained and driver-provided adapters.

25 ENERGY STORAGE↗

Optical and photoelectric properties of surface barrier diodes based on n- Hg3In2Te6 crystals

The high radiation resistance of Hg3In2Te6 (MIT) single crystals to large doses of ionizing radiation makes devices quite attractive. Such a feature of the crystal structure has not only important advantages, but also causes serious technological difficulties in doping and controlling the specific resistance within the required limits and type of conductivity of single crystals. These technological difficulties create serious problems when creating structures with a potential barrier, especially with a p-n junction. At the moment, there are no publications on the creation of a p-n junction based on MIT. The only alternative is to create a potential barrier such as a Schottky diode or a metal-dielectric-semiconductor structure. This limits the use of MIT to produce, for example, rectifier diodes that can operate at relatively high reverse bias voltages. The typical resistivity of single crystals of MIT of n-type conductivity, which are used for the manufacture of diodes and photodiodes, is approximately equal to ρ≈103-104 Ω×cm. Such a specific resistance leads to a relatively large resistance of the neutral part of the single crystal, which in turn limits the direct currents of the rectifier diodes and significantly limits an important parameter of photodiodes - the dynamic range of the watt-ampere characteristic. This problem arises from the relatively high series resistance of the substrate. For rectifier diodes, this relatively large series resistance leads to a significant forward bias voltage drop, which reduces both the rectification factor and the amount of rectified current. We have already created diodes and photodiodes on Cr/MIT/Cr single crystals with a specific resistance of ρ≈103-104 Ω×cm. The diodes had relatively small dark currents but had the disadvantage of a relatively large specific resistance of the substrate, which we have already discussed above [1,2,3].

Sklyarchuk, V.↗

Impact of Technology Improvements on the Cost of Hydrogen Produced using SOEC Technology at Large Scale

National Energy Technology Laboratory (NETL) provides system-level process, cost, and market analyses on solid oxide cell (SOC) based technologies. Specifically, techno-economic analyses (TEA), market assessments, and other technology evaluations serve to guide the U.S. Department of Energy (DOE) Office of Fossil Energy and Carbon Management (FECM) Reversible Solid Oxide Fuel Cell (R-SOFC) Program technology goals and objectives. These studies are key to describing how the technologies contribute to improving domestic energy infrastructure in a clean, efficient manner. This effort focuses on hydrogen generation technologies, which have received recent attention due to their potential role in economy-wide decarbonization. In particular, the study is part of a series of investigations at NETL that seek to understand the techno-economic impacts of including SOC technology in energy production, hydrogen production, and/or storage configurations. The objective of this study is to establish a detailed TEA to assess the effectiveness of incremental technology improvements needed for solid oxide electrolysis cell (SOEC) technology to achieve the U.S. DOE’s Hydrogen Shot goal of hydrogen production at less than $1 per kilogram. To take advantage of the benefits of economies of scale, the SOEC hydrogen facilities are sized to produce ≈250,000 metric tons of hydrogen annually with an electrolysis load of one gigawatt (direct current). Some additional critical assumptions include stacks that operate near the thermo-neutral voltage of 1.28 V to avoid adverse thermal gradients, all necessary steam and heat is generated by electric boilers and heaters to enable green hydrogen production, and an air sweep is used to control the oxygen concentration in the air electrode exhaust stream. System efficiency and levelized costs of hydrogen (LCOH) for each case are presented.

Hackett, Gregory↗

I-80 Mid-America Clean Fuels Corridor: Deployment Plan Report

The I-80 Mid-America Clean Fuels Corridor, which spans I-80 from Fort Lee, New Jersey, to Council Bluffs, Iowa, was designated an Alternative Fuels Corridor (AFC) in Round 1 of the Alternative Fuels Corridor program administered by the U.S. Department of Transportation’s (DOT’s) Federal Highway Administration (FHWA). Originally called the “I-80 Mid-America Alternative Fuels Corridor,” it is now named the “I-80 Mid-America Clean Fuels Corridor.” As of Round 6 AFC designation, parts of the corridor have sufficient direct current fast charging (DCFC) stations to be designated Electric Vehicle (EV)-Ready and sufficient compressed natural gas (CNG) fueling stations to be designated CNG-Ready. However, much of the corridor’s approximately 1,240 miles (mi) are not yet EV- or CNG-Ready. This includes about 1,130 mi that are designated EV-Pending and 700 mi that are designated CNG-Pending. This report presents a plan to develop EV charging and CNG fueling infrastructure sufficient to convert the entire length of the corridor to EV-Ready and CNG-Ready. Specific sites are not identified for future infrastructure. Rather, priority exits are identified, and information, analysis, and additional steps are recommended to support further refinement of these locations, as well as additional outreach and deployment efforts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Mining – Image Analysis of Radiography for Zr Redistribution

The research effort described in this report represents a first attempt to investigate the radial redistribution of Zr in ternary fuel alloys U-xPu-10Zr (x = 0, 8, 19) irradiated in the in-reactor fuel experiments during the operation of the U.S. Department of Energy’s (DOE’s) Experimental Breeder Reactor II (EBR-II) at Idaho National Laboratory (INL) using methods of image processing on post-irradiation neutron radiographs. Approximately 130,000 metal fuel pins were irradiated in EBR-II during its 30 years of operation to develop and characterize existing and prospective fuels. For many of the metal fuel irradiation experiments, neutron radiography imaging was performed historically now allowing application of modern image analysis techniques to characterize fuel behavior, such as fuel swelling, fluff formation, and now, fuel alloy constituent redistribution. The redistribution of fuel components depends on the temperature field, radially, within the fuel. Specifically, Zr is expected to redistribute radially towards the center of the pin, as well as towards the outer zones. Currently, direct imaging of a pin cross-section through optical methods or scanning electron microscopy (SEM) is used to study the constituents’ redistribution, which is very time-consuming and can only be applied to a limited number of pins. An automated image processing technique allowing for the investigation of fuel radial redistribution zones would significantly accelerate data analysis. In general, if the fuel temperature is hot enough, three redistribution zones are expected, corresponding to the main fuel components (e.g., U, Pu, Zr). While more assessment will be performed in fiscal year (FY)-2023, it seems possible to differentiate the pins according to their fuel composition using image analysis techniques on neutron radiographs of metallic fuel pins based on the analysis to date.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE↗

Materials Degradation in Extreme Environments: Novel In-situ Measurements of Cracking in Molten Salt

The safety and reliability of next-gen reactors, i.e. molten salt reactors (MSR), depends on materials performance and longevity in extreme environments, yet no in-situ, validated measurement techniques for environmentally assisted cracking (EAC), one potential degradation mechanism, exist for these conditions. This project combined the use of in-situ direct current potential drop (DCPD) crack growth rate determination applied to a horizontal load frame with high temperature fittings and novel sample geometries to enable evaluation in MSR environments and develop a full in-situ SCC measurement capability for extreme environments (high conductivity and elevated T), necessary to predict materials reliability. A successful demonstration of DCPD measurement in molten NaNO 3 /KNO 3 salts at 340 o C was accomplished and validated through post-test fractography imaging. This is the first ever public example, to the authors knowledge, of an in-situ crack growth rate measurement in a molten salt environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scalable Hybrid Large-Scale dc-ac Grid Analysis Methods (Phase II)

The goals of the project included the identification and evaluation of a voltage source converter multiterminal high-voltage direct current (VSC-MTdc) system architecture suitable for a high amount of power transfer through long transmission lines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Communications Reliability for Vehicle Grid Integration

Electric Vehicles (EVs) adoption rate has been steadily increasing in the US leading to a growing number of charging stations including faster DC (Direct Current) chargers and slower Level 1 and Level 2 AC (Alternating Current) chargers. This increase in demand for electricity is further exacerbated by recent developments in Artificial Intelligence (AI) technology, advanced manufacturing, and digitization. These factors will require electric utilities to upgrade their infrastructure to keep up with the increasing electrical demand (especially during peak hours). An easy way to counteract the need for these upgrades is to shift a major chunk of active charge sessions (durations where there is energy transfer from charger to EV's propulsion battery) to off-peak hours thereby flattening the load curve and making the infrastructure more resilient. This concept is known as Smart Charge Management (SCM). EV owners also benefit from SCM since it lowers their charging costs and consequently their transportation costs by prioritizing charging during off-peak hours. SCM takes advantage of EV's capability to act as a controllable load or DER (Distributed Energy Resource). This report summarizes the reliability analysis performed on the communication required for two of these SCM use-cases. This analysis only focuses on SCM strategies for unidirectional charging (energy transfer from EVSE to EV or V1G) and not bidirectional charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluations of Connectors, Inlets, and Adapters on Side-Load and Withstand Force

This report examines the mechanical forces that direct current fast charging (DCFC) electric vehicle supply equipment (EVSE) connectors and electric vehicle (EV) inlet ports experience during normal usage. As we witness the fast and growing variety of EVs, charge port locations, and bigger and more powerful EVSE configurations including the SAE J3400 North American Charging Standard (NACS), which has increased the use of adapters with J3400 and J1772 compatibility. These new conditions contribute to increased mechanical forces due to their size, weight and lever arm effect, which creates the need to study and compare these forces to the limits on UL2251 and IEC 62196-1 standards. This report focuses solely on high power DC charging EVSE connectors, EV inlets and adapters for the specific compatibility cases on J3400 with J1772. We first describe the details of the 100N and the 750N side-load evaluations as described in the standards, then present the data obtained by replicating these tests to finally go into more detail on the findings and our recommendations.

100N↗

Towaoc Housing Solar Initiative

The Towaoc Housing Solar initiative was implemented to install net-metered solar generation systems on twenty-three Tribal buildings in Towoac, CO on the Ute Mountain Ute Reservation. The project was funded 80% by Department of Energy and 20% by the Ute Mountain Ute Tribe. The project and grant are authorized by Ute Mountain Ute Tribal Council Resolution 2020-116. The systems were designed to cumulatively generate 160 direct current (DC) kilowatts on average, translating to 222,585 kilowatt hours per year. The average cost for the generation was calculated at $\$$3.34/watt with a return on investment period anticipated at 22 years for a simple payback of all costs, 11 years for the Tribe’s investment at 50% cost-share. The systems should last for 30 years. The primary goals of the project for the Tribe were identified as the reduction of electricity costs for the twenty three Tribal buildings of the Housing Authority (comprising 22 rental homes and a small apartment building with 11 units) and the reduction of carbon pollution through the transition of energy sources used in the buildings.

14 SOLAR ENERGY↗

Novel Zwitterionic Chromatography to Separate Lithium from Unconventional Resources

Since lithium (Li) is a key element for clean energy technologies, the global lithium demand is anticipated to increase rapidly. As a result, efficient lithium extraction technologies that allow the exploitation of unconventional lithium resources, such as geothermal brines and inland brine streams, are essentially needed to meet the Li demand and keep supply chains stable. However, because of low Li concentration, low ratio of Li/Mg or Li/Ca, and complex feed compositions in these feedstocks, using conventional hydrometallurgy or current Direct Lithium Extraction (DLE) processes are often chemical-intensive, requiring substantial amounts of reagent chemicals to recover Li at scale, resulting in large chemical footprints. Therefore, we developed a novel Zwitterionic Chromatography (ZIC) process to separate Li from these resources. Because Li can be partitioned from divalent salts on ZIC under water elution without using chemicals, exploiting the unconventional resources via a ZIC approach can be environmentally benign and sustainable. In this work, we will present the development of the ZIC process for DLE applications. Simulation studies for the Li separation mechanism in ZIC and the demonstration of a continuous ZIC process to separate Li from domestic inland brine and mining wastewater will be presented. Finally, the chemical and energy footprints of ZIC in comparison to other DLE processes will be discussed.

09 BIOMASS FUELS↗

Interregional Transmission Operational Coordination (IRTOC)

This report presents a modeling and evaluation framework developed through the Inter-Regional Transmission Operational Coordination (IRTOC) project to study market-to-market (M2M) congestion management across day-ahead and real-time markets. The framework extends the Sienna platform through Sienna Decomposition, a multi-stage evaluation architecture that enables flexible representation of multiple regions and systematic assessment of alternative market coordination designs. Additional modeling capabilities include reserve deliverability constraints, High-Voltage Direct Current (HVDC) optimization for Alternating Current (AC) congestion management, and several real-time distributed coordination algorithms. Case studies using the RTS-GMLC test system and a large-scale Eastern Interconnection model demonstrate that the framework can evaluate alternative coordination structures and quantify their economic and operational impacts. The proposed framework provides a scalable platform for analyzing inter-regional coordination strategies in large-scale electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integration of Solid Oxide Fuel Cell Systems Into Artificial Intelligence Data Centers

This report presents the results of a techno-economic analysis (TEA) that evaluates the economic benefits of integrating solid oxide fuel cell (SOFC) systems with artificial intelligence (AI) data centers. The analysis was completed in two phases: a scoping-level analysis was performed to identify impactful integration opportunities, followed by a more detailed TEA. Results show that, due to their modularity, SOFC can meet the 99.999% availability requirement of data centers with minimal additional costs. Heat integration via absorption chillers decreases data center electricity consumption at the tradeoff of increased water consumption. Higher SOFC exhaust temperatures are important for achieving larger electricity savings. Finally, power electronics integration with SOFC direct current electricity can reduce electricity consumption by 9 percent and reduce water consumption by 6.4 percent.

20 FOSSIL-FUELED POWER PLANTS↗

Casing Annulus Monitoring of CO 2 Injection Using Wireless Autonomous Distributed Sensor Networks

Effective and secure carbon subsurface storage, involving the deep underground injection of CO 2 into geological formations where it is permanently trapped, is paramount to mitigating CO 2 emissions (Figure I). Ensuring the integrity of these storage sites and detecting potential leakage through the casing annulus necessitates robust monitoring. This work provides the first integrated demonstration of a wireless casing-annulus monitoring architecture that can operate in highly attenuating cement-brine environments relevant to CO 2 storage. This project focused on developing and validating a novel sensor system for integration with autonomous monitoring near the cement reservoir interface. The goal was a fully integrated Technology Readiness Level (TRL) 4/5 field validation of a distributed wireless intelligent sensor system providing real-time, direct subsurface formation measurements to enhance fluid movement monitoring in the cemented casing annulus. Achieving this objective required the development and integration of 1) wireless autonomous microsensor technology by California Institute of Technology (Caltech); 2) sensor packaging and emplacement technology by Research Triangle Institute (RTI); and 3) smart well completions using wireless active casing collars and NOV pipe by the Sandia National Lab (SNL). The collaboration with the Caltech team in this project aimed to develop millimeter-scale radio frequency identification (RFID) sensors capable of detecting CO 2 , pH, and/or methane levels. These sensors are engineered to be impervious to fluids, allowing them to be mixed with cement and installed within the casing annulus. They operate using RFID protocols at frequencies of 902–928 MHz for both power and communication. A Sandia National Laboratories’ team engaged their expertise in the development of a Smart Collar system designed for the wireless data collection from these RFID sensors embedded in the cement annulus and transmission of this information to the ground surface via IntelliPipe/IntelliServ NOV drill pipe. This is accomplished through inductive coupling at the collar, which facilitates data transfer through each segment of the pipe. Because the system cannot transmit a direct current signal to power the Smart Collar, both power and communication were implemented using alternating current and electromagnetic signals at varying frequencies. Furthermore, the developed microsensor technology had to be demonstrated and validated in comparison with reference transducer measurements in a field test site at The University of Texas at Austin (UT-Austin). Although the full sensor suite did not reach field-deployment readiness, the system-level integration achieved in this project establishes a validated pathway for future incorporation of advanced microsensors.

47 OTHER INSTRUMENTATION↗