Soft x ray window encapsulant for HgI2 detectors

HgI2 is an excellent semiconductor material for a low energy, room temperature x-ray spectrometer. The high values of the atomic numbers for its constituent elements gives high x-ray and gamma ray stopping power. The band gap of HgI2 is significantly higher than other commonly used semiconductors. Owing to the large value band gap, the leakage current for HgI2 devices is smaller, thus allowing low noise performance. Devices fabricated from HgI2 crystals have demonstrated energy resolution sufficient to distinguish the x-ray emission from the neighboring elements on the periodic table. Also the power requirements of HgI2 are very low. These characteristics make a HgI2 spectrometer an ideal component in a satellite based detection system. Unfortunately, HgI2 crystals tend to deteriorate with time, even if protected by standard semiconductor encapsulants. This degradation ruins the performance of the device in terms of its energy resolution and pulse amplitude. The degrading mechanism is believed to be material loss occurring from below the electrodes, due to high vapor pressure of HgI2 at room temperature. To address this major obstacle to rapid expansion of HgI2 technology, a research program aimed at improving device stability by encapsulation with inert polymeric materials was carried out. The program focused specifically on optimizing the encapsulant materials and their deposition techniques. The principal objectives for this program were device encapsulation, device testing, and accelerated testing to ensure very long term stability of these high resolution sensors. A variety of encapsulants were investigated with the selection criteria based on their chemical diffusion barrier properties, mechanical stability, reactivity, and morphology of encapsulant films. The investigation covered different classes of encapsulants including solvent based encapsulants, vapor deposited encapsulants, and plasma polymerized encapsulants. A variety of characterization techniques were employed to examine their effectiveness in stabilizing HgI2 devices; these included permeability evaluation, vacuum and heat testing, scanning electron microscopy (SEM) as well as studying the detector performance of coated detectors. The plasma polymerized films appear to have entirely solved the HgI2 degradation problem. Another achievement of this program was the development of an accelerated testing technique which correlates extremely well with long term tesing.

Entine, G.↗

Electrical characterization of glass, teflon, and tantalum capacitors at high temperatures

Dielectric materials and electrical components and devices employed in radiation fields and the space environment are often exposed to elevated temperatures among other things. Therefore, these systems must withstand the high temperature exposure while still providing good electrical and other functional properties. Experiments were carried out to evaluate glass, teflon, and tantalum capacitors for potential use in high temperature applications. The capacitors were characterized in terms of their capacitance and dielectric loss as a function of temperature up to 200 C. At a given temperature, these properties were obtained in a frequency range of 50 Hz to 100 kHz. The DC leakage current measurements were also performed in a temperature range from 20 to 200 C. The obtained results are discussed and conclusions are made concerning the suitability of the capacitors investigated for high temperature applications.

Hammoud, A. N.↗

Characterization and recovery of Deep Sub Micron (DSM) technologies behavior under radiation

This paper serves a twofold purpose: characterize the behavior of a reconfigurable chip exposed to radiation; and demonstrate a method for functionality recovery due to Total Ionizing Dose (TID) effects. The experiments are performed using a PL developed reconfigurable device, a Field Programmable Transistor Array (FPTA). The paper initially describes experiments on the characterization of the NMOS transistor behavior for TID values up to 300krad. The behavior of analog and digital circuits downloaded onto the FPTA chip is also assessed for TID effects. This paper also presents a novel approach for circuit functionality recovery due to radiation effects based on Evolvable Hardware. The key idea is to reconfigure a programmable device, in-situ, to compensate, or bypass its degraded or damaged components. Experiments with total radiation dose up to 300kRad show that while the functionality of a variety of circuits, including digital gates, a rectifier and a Digital to Analog Converter implemented on a FPTA-2 chip is degraded/lost at levels before 200kRad, the correct functionality can be recovered through the proposed evolutionary approach and the chips are able to survive higher radiation, for several functions in excess of total radiation dose of 250kRad.

evolvable hardware↗

Installation and Characterization of Charged Particle Sources for Space Environmental Effects Testing

Charged particle sources are integral devices used by Marshall Space Flight Center s Environmental Effects Branch (EM50) in order to simulate space environments for accurate testing of materials and systems. By using these sources inside custom vacuum systems, materials can be tested to determine charging and discharging properties as well as resistance to sputter damage. This knowledge can enable scientists and engineers to choose proper materials that will not fail in harsh space environments. This paper combines the steps utilized to build a low energy electron gun (The "Skevington 3000") as well as the methods used to characterize the output of both the Skevington 3000 and a manufactured Xenon ion source. Such characterizations include beam flux, beam uniformity, and beam energy. Both sources were deemed suitable for simulating environments in future testing.

Skevington, Jennifer L.↗

Single photon X-ray imaging with charge-coupled devices /CCDs/

The paper describes a CCD camera facility designed and built for testing and characterization of CCDs in response to single X-ray photons in the 1-10 keV energy range. Results from the frontside-illuminated Fairchild 211 and 221 area imagers are presented; high quantum efficiency over the 3-6 keV range was verified. In order to avoid the problem of charge spreading at the higher energies, deep-depleted CCDs for soft X-ray imaging have been constructed, and good response was obtained at 6 keV. The present results are a first step toward the demonstration of the CCD as an appropriate device for at least the central part of the focal plane of a large X-ray telescope, e.g., the proposed Advanced X-ray Astrophysics Facility.

Griffiths, R. E.↗

Performance Measurement of a Multi-Level/Analog Ferroelectric Memory Device Design

Increasing the memory density and utilizing the unique characteristics of ferroelectric devices is important in making ferroelectric memory devices more desirable to the consumer. This paper describes the characterization of a design that allows multiple levels to be stored in a ferroelectric based memory cell. It can be used to store multiple bits or analog values in a high speed nonvolatile memory. The design utilizes the hysteresis characteristic of ferroelectric transistors to store an analog value in the memory cell. The design also compensates for the decay of the polarization of the ferroelectric material over time. This is done by utilizing a pair of ferroelectric transistors to store the data. One transistor is used a reference to determinethe amount of decay that has occurred since the pair was programmed. The second transistor stores the analog value as a polarization value between zero and saturated. The design allows digital data to be stored as multiple bits in each memory cell. The number of bits per cell that can be stored will vary with the decay rate of the ferroelectric transistors and the repeatability of polarization between transistors. This paper presents measurements of an actual prototype memory cell. This prototype is not a complete implementation of a device, but instead, a prototype of the storage and retrieval portion of an actual device. The performance of this prototype is presented with the projected performance of the overall device. This memory design will be useful because it allows higher memory density, compensates for the environmental and ferroelectric aging processes, allows analog values to be directly stored in memory, compensates for the thermal and radiation environments associated with space operations, and relies only on existing technologies.

MacLeod, Todd C.↗

Ferroelectric Devices Emit Charged Particles and Radiation

Devices called solid-state ferroelectric- based sources (SSFBSs) are under development as sources of electrons, ions, ultraviolet light, and x-rays for diverse applications in characterization and processing of materials. Whereas heretofore it has been necessary to use a different device to generate each of the aforementioned species of charged particles or radiation, a single SSFBS can be configured and operated to selectively generate any of the species as needed using a single source. Relative to comparable prior sources based, variously, on field emission, thermionic emission, and gaseous discharge plasmas, SSFBSs demand less power, and are compact and lightweight. An SSFBS exploits the unique physical characteristics of a ferroelectric material in the presence of a high-frequency pulsed electric field. The basic building block of an SSFBS is a ferroelectric cathode -- a ferroelectric wafer with a solid electrode covering its rear face and a grid electrode on its front face (see figure). The application of a voltage pulse -- typically having amplitude of several kilovolts and duration of several nanoseconds -- causes dense surface plasma to form near the grid wires on the front surface.

Bar-Cohen, Yoseph↗

Temperature and Strain Coefficient of Velocity for Langasite SAW Devices

Surface Acoustic Wave sensors on Langasite substrates are being investigated for aerospace applications. Characterization of the Langasite material properties must be performed before sensors can be installed in research vehicles. The coefficients of velocity for both strain and temperature have been determined. These values have also been used to perform temperature compensation of the strain measurements.

Wilson, W. C.↗

Focal Plane Geometry Characterization of the Kepler Mission

The Kepler Mission focal plane contains 42 charge-coupled device (CCD) photodetectors. Each CCD is composed of 2.2 million square pixels, 27 micrometers on a side, arranged in a grid of 2,200 columns by 1,044 rows. The science goals of the Kepler Mission require that the position of each CCD be determined with an accuracy of 0.1 pixels, corresponding to 2.7 micrometers or 0.4 seconds of arc, a level which is not achievable through pre-flight metrology. We describe a technique for determining the CCD positioning using images of the Kepler field of view (FOV) obtained in flight. The technique uses the fitted centroid row and column positions of 400 pre-selected stars on each CCD to obtain empirical polynomials which relate sky coordinates (right ascension and declination) to chip coordinates (row and column). The polynomials are in turn evaluated to produce constraints for a nonlinear model fit which directly determines the model parameters describing the location and orientation of each CCD. The focal plane geometry characterization algorithm is itself embedded in an iterative process which determines the focal plane geometry and the Pixel Response Function for each CCD in a self-consistent manner. In addition to the fully automated calculation, a person-in-the-loop implementation was developed to allow an initial determination of the geometry in the event of large misalignments, achieving a much looser capture tolerance for more modest accuracy and reduced automation.

ccd↗

The alkali metal thermoelectric converter /AMTEC/ - A new direct energy conversion technology for aerospace power

A thermally regenerative electrochemical device for the direct conversion of heat to electrical energy, the alkali metal thermoelectric converter (AMTEC), is characterized by potential efficiencies on the order of 15-40% and possesses no moving parts, making it a candidate for space power system applications. Device conversion efficiency is projected on the basis of experimental voltage vs current curves exhibiting power densities of 0.7 W/sq cm and measured electrode efficiencies of up to 40%. Preliminary radiative heat transfer measurements presented may be used in an investigation of methods for the reduction of AMTEC parasitic radiation losses. AMTEC assumes heat input and rejection temperatures of 900-1300 K and 400-800 K, respectively. The working fluid is liquid sodium, and the porous electrode employed is of molybdenum.

Bankston, C. P.↗

Thermal and infrared testing

The detection of defective components in devices which are active heat sources, and the detection and characterization of flaws in structures that are thermally passive, but which can be nondestructively heated or cooled are described. The physical principles and thermal detectors and methods are discussed along with contact, and noncontact thermographic methods.

Engelhardt, R. E.↗

High sensitivity 1.06 micron optical receiver for precision laser range finding

Aluminum gallium antimonide avalanche photodiodes with average gain of 10, internal quantum efficiency of greater than 60%, capacitance less than 0.2pf, and dark current of less than 1 micron were designed and fabricated for use in a low noise optical receiver suitable for 2 cm accuracy rangefinding. Topics covered include: (1) design of suitable photodetector structures; (2) epitaxial growth of AlGaSb devices; (3) fabrication of photodetectors; and (4) electro-optics characterization.

Scholl, F. W.↗

Indium antimonide infrared CCD linear imaging arrays with on-chip preprocessing

A description is presented of the fabrication of a new InSb CCD chip based on an improved process which eliminates the limitations inherent with the earlier techniques. This process includes planar junction formation and an aluminum and SiO2 material system which is amenable to state-of-the-art chemical and plasma delineation techniques. Further, the new chip integrates for the first time in monolithic format InSb IR detectors with an InSb CCD. The reported experiments represent the first operation of an InSb infrared CCD array. In addition to fuller characterization of the 20-element charge-coupled infrared imaging device, several factors which influence device performance are currently being addressed. These include surface state density, the CCD output circuit, and storage time (dark current).

Thom, R. D.↗

Reduction of solar cell efficiency by edge defects across the back-surface-field junction - A developed perimeter model

Material imperfections, impurity clusters and fabrication defects across the back-surface-field junction can degrade the performance of high-efficiency solar cells. The degradation from defects appearing on the circumference of a solar cell is analyzed using a two-region developed perimeter device model. The width of the defective perimeter region is characterized by the range or the distance-of-influence of the defective edge and this width is about two diffusion lengths. The defective edge is characterized by a surface recombination velocity. Family of theoretical curves and numerical examples are presented to show that significant reduction of open-circuit voltage can occur in high-efficiency cells which are thin compared with the diffusion length. In one example, the degradation is decreased from 135 mV to 75 mV when the cell size is increased from 10 to 100 times the diffusion length in a thin cell whose thickness is 1% of the diffusion length.

Sah, C. T.↗

Analytical ultrasonics for evaluation of composite materials response. Part 2: Generation and detection

To evaluate the response of composite materials, it is imperative that the input excitation as well as the observed output be well characterized. This characterization ideally should be in terms of displacements as a function of time with high spatial resolution. Additionally, the ability to prescribe these features for the excitation is highly desirable. Various methods for generating and detecting ultrasound in advanced composite materials are examined. Characterization and tailoring of input excitation is considered for contact and noncontact, mechanical, and electromechanical devices. Type of response as well as temporal and spatial resolution of detection methods are discussed as well. Results of investigations at Virginia Tech in application of these techniques to characterizing the response of advanced composites are presented.

Duke, J. C., Jr.↗

National plans for aircraft icing and improved aircraft icing forecasts and associated warning services

Recently, the United States has increased its activities related to aircraft icing in numerous fields: ice phobics, revised characterization of icing conditions, instrument development/evaluation, de-ice/anti-ice devices, simulated supercooled clouds, computer simulation and flight tests. The Federal Coordinator for Meteorology is involved in two efforts, one a National Plan on Aircraft Icing and the other a plan for Improved Aircraft Icing Forecasts and Associated Warning Services. These two plans will provide an approved structure for future U.S. activities related to aircraft icing. The recommended activities will significantly improve the position of government agencies to perform mandated activities and to enable U.S. manufacturers to be competitive in the world market.

Pass, Ralph P.↗

Polarization effects, tasks 3 and 4

The LP-140 is a commercial pulsed CO2 laser system. An attempt was made to convert this workhorse laser into a device suitable for coherent LIDAR applications. This required initial laser characterization, and system modification. The key changes which enabled the laser to display encouraging characteristics are: increased cavity length; increased gas flow; gas mixture modification; and power supply redesign. With suitable modifications, the LP-140 becomes a viable candidate for a coherent LIDAR.

Jaenisch, H. M.↗

Low-loss monolithic transmission lines for submillimeter and terahertz frequency applications

The design and construction of low-loss monolithic transmission lines are critical to systems which require that terahertz-power be guided to the antenna front ends. Two types of novel monolithic guiding structures, designed for the 0.3-2.0 THz and 0.1-0.3 THz ranges, respectively, are proposed. The novel waveguides are constructed from dielectric materials and structures which are available in monolithic technology so that the integration of active devices is possible. Propagation in each of the waveguides is characterized over relevant frequency ranges by applying a mode-matching technique, which takes into account all forms of electromagnetic coupling as well as losses in the dielectrics. The structures are predicted to exhibit excellent power confinement and low losses.