Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Linearity Analysis and Efficiency Testing of The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) Science Cameras for Flight

To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to elucidate the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in Hydrogen Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this emission line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Magnesium II h & k emission lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.

linearit↗

Linearity Analysis and Efficiency Testing of The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) Science Cameras for Flight

To unveil the complexity of the solar atmosphere, measurement of the magnetic field in the upper chromosphere and transition region is fundamentally important, as this is where the forces transition from plasma to magnetic field dominated. Measurements of the field are also needed to elucidate the energy transport from the lower atmospheric regions to the corona beyond. Such an advance in heliospheric knowledge became possible with the first flight of the international solar sounding rocket mission, CLASP. For the first time, linear polarization was measured in Hydrogen Lyman-Alpha at 121.60 nm in September 2015. For linear polarization measurements in this emission line, high sensitivity is required due to the relatively weak polarization signal compared to the intensity. To achieve this high sensitivity, a low-noise sensor is required with good knowledge of its characterization, including linearity. This work presents further refinement of the linearity characterization of the cameras flown in 2015. We compared the current from a photodiode in the light path to the digital response of the detectors. Pre-flight CCD linearity measurements were taken for all three flight cameras and calculations of the linear fits and residuals were performed. However, the previous calculations included a smearing pattern and a digital saturation region on the detectors which were not properly taken into account. The calculations have been adjusted and were repeated for manually chosen sub-regions on the detectors that were found not to be affected. We present a brief overview of the instrument, the calibration data and procedures, and a comparison of the old and new linearity results. The CLASP cameras will be reused for the successor mission, CLASP2, which will measure the Magnesium II h & k emission lines between 279.45 nm and 280.35 nm. The new approach will help to better prepare for and to improve the camera characterization for CLASP2.

detector↗

Full Inversion of Solar Relativistic Electron Events Measured by the Helios Spacecraft

The Parker Solar Probe and the incoming Solar Orbiter mission will provide measurements of solar energetic particle (SEP) events at close heliocentric distances from the Sun. Up to present, the largest data set of SEP events in the inner heliosphere are the observations by the two Helios spacecraft. Aims.We re-visit a sample of 15 solar relativistic electron events measured by the Helios mission with the goal of better characterizing the injection histories of solar energetic particles and their interplanetary transport conditions at heliocentric distances <1AU. Methods. The measurements provided by the E6 instrument on board Helios provide us with the electron directional distributionsin eight di erent sectors that we use to infer the detailed evolution of the electron pitch-angle distributions. The results of a Monte Carlo interplanetary transport model, combined with a full inversion procedure, were used to fit the observed directional intensities in the 300–800 keV nominal energy channel. Unlike previous studies, we have considered both the energy and angular responses of the detector. This method allowed us to infer the electron release time profile at the source and determine the electron interplanetary transport conditions. Results. We discuss the duration of the release time profiles and the values of the radial mean free path, and compare them with thevalues reported previously in the literature using earlier approaches. Five of the events show short injection histories (<30 min) at the Sun and ten events show long-lasting (>30 min) injections. The values of mean free path range from 0.02AU to 0.27AU.Conclusions. The inferred injection histories match with the radio and soft X-ray emissions found in literature.We find no dependence of the radial mean free path on the radial distance. In addition, we find no apparent relation between the strength of interplanetary scattering and the size of the solar particle release.

Pacheco, D.↗

First Results from Laser-Based Spectral Characterization of Landsat 9 Operational Land Imager-2

Landsat 9 will continue the Landsat data record into its fifth decade with launch scheduled for December 2020. The two instruments on Landsat 9 are Thermal Infrared Sensor-2 (TIRS-2) and Operational Land Imager-2 (OLI-2). OLI-2 is a nine-channel pushbroom imager with a 15-degree field of view that will have a 16-day measurement cadence from its nominal 705-km orbit altitude. A key aspect of the data that will be produced by OLI-2 is its spectral fidelity which enables countless science applications. The prelaunch test campaign for spectral characterization of OLI-2 was substantially improved relative to the methodology used for OLI: the full spectral response of every detector was characterized with greater accuracy, sampling, and precision. This paper will describe how this was accomplished with a tunable laser-based light source called Goddard Laser for Absolute Measurement of Radiance (GLAMR).

tunable laser↗

RadLab: A Comprehensive Database and Analysis Toolkit for Space Radiation Measurements Relevant to Space Radiation Biology

RadLab, a new addition to the NASA Open Science Data Repository (OSDR), is a public platform for space radiation data relevant to human space exploration. RadLab consists of a database, a submission portal, and user-friendly visualization and data analysis tools, including a graphical user interface (GUI) and an application programming interface (API). Investigators from ISS partners including Germany, Italy, Canada, Hungary, the Czech Republic, Russia, Japan have committed to providing data from their instruments. RadLab will also include data from other spacecraft in LEO: the Space Shuttle, the Mir space station, biosatellites; and beyond LEO: the lunar and the Martian surface, the heliocentric orbit at 1 AU, Mars orbit, and Earth-Mars space. Once fully operational, RadLab will provide open, centralized access to space radiation physics data relevant to human space exploration; a platform for submission of data by agencies and research institutions responsible for radiation detectors deployed in space; analysis tools to facilitate detector and dataset intercomparison to better understand space habitat radiation environments; capabilities for space biology investigators to determine the radiation environment to which samples were exposed. A RadLab Working Group (RLWG) has been formed, modeled on the GeneLab Analysis Working Groups and comprised of data contributors and users. RLWG tasks include identifying data sources, normalizing data from diverse detectors, expanding the analysis toolkit and, perhaps most importantly, sharing ideas for research exploiting capabilities of RadLab. We will provide an overview of RadLab data and capabilities and discuss examples of its potential as a resource for open science.

radiation↗

Polarized polymer films as electronic pulse detectors of cosmic dust particles

A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.

Simpson, J. A.↗

Infrared focal plane performance in the South Atlantic anomaly

Proton-induced pulse height distributions (PHD's) in Si:XX detectors were studied analytically and experimentally. In addition, a preliminary design for a flight experiment to characterize the response of Si:XX detectors to the trapped proton environment and verify PHD models was developed. PHD's were computed for two orbit altitudes for a variety of shielding configurations. Most of the proton-induced pulses have amplitudes less that about 3.5 x 10(exp 5) e-h pairs. Shielding has a small effect on the shape of the PHD's. The primary effect of shielding is to reduce the total number of pulses produced. Proton-induced PHD's in a Si:Sb focal plane array bombarded by a unidirectional 67-MeV beam were measured. The maximum pulse height recorded was 6 x 10(exp 5) pairs. The distribution had two peaks: the larger peak corresponded to 3.8 x 10(exp 5) pairs and the smaller peak to 1.2 x 10(exp 5) pairs. The maximum pulse height and the larger peak are within a factor of two of predicted values. The low-energy peak was not expected, but is believed to be an artifact of inefficient charge collection in the detector. The planned flight experiment will be conducted on a Space Shuttle flight. Lockheed's helium extended life dewar (HELD) will be used to provide the required cryogenic environment for the detector. Two bulk Si:Sb arrays and two Si:As impurity band conduction arrays will be tested. The tests will be conducted while the Space Shuttle passes through the South Atlantic Anomaly. PHD's will be recorded and responsivity changes tracked. This experiment will provide a new database on proton-induced PHD's, compare two infrared detector technologies in a space environment, and provide the data necessary to validate PHD modeling.

Junga, Frank A.↗

Advanced far infrared blocked impurity band detectors based on germanium liquid phase epitaxy

This research has shown that epilayers with residual impurity concentrations of 5 x 10(sup 13) cm(exp -3) can be grown by producing the purest Pb available in the world. These epilayers have extremely low minority acceptor concentrations, which is ideal for fabrication of IR absorbing layers. The Pb LPE growth of Ge also has the advantageous property of gettering Cu from the epilayer and the substrate. Epilayers have been grown with intentional Sb doping for IR absorption on lightly doped substrates. This research has proven that properly working Ge BIB detectors can be fabricated from the liquid phase as long as pure enough solvents are available. The detectors have responded at reach minimum wavenumbers. Optimization of the Sb doping concentration should further decrease the photoionization energy of these detectors. Ge BIB detectors have been fabricated that respond to 60 cm(exp -1) with low responsivity. Through reduction of the minority residual impurities, detector performance has reached responsivities of 1 A/W. These detectors have exhibited quantum efficiency and NEP values that rival conventional photoconductors and are expected to provide a much more sensitive tool for new scientific discoveries in a number of fields, including solid state studies, astronomy, and cosmology.

Olsen, C. S.↗

BATSE Observations of Gamma-Ray Burst Spectra: Low-Energy Behavior of Time-Averaged Spectra - Part 3

We analyze time-averaged spectra from 86 bright gamma-ray bursts from the first 5 years of the Burst And Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory to determine whether the lowest energy data are consistent with a standard spectra form fit to the data at all energies. The BATSE Spectroscopy Detectors have the capability to observe photons as low as 5 keV. Using the gamma-ray burst locations obtained with the BATSE Large Area Detectors, the Spectroscopy Detectors' low-energy response can be modeled accurately. This, together with a postlaunch calibration of the lowest energy Spectroscopy Detector discriminator channel, which can lie in the range 5-20 keV, allows spectral deconvolution over a broad energy range, approx. 5 keV to 2 MeV. The additional coverage allows us to search for evidence of excess emission, or for a deficit, below 20 keV. While no burst has a significant (greater than or equal to 3 sigma) deficit relative to a standard spectra model, we find that 12 bursts have excess low-energy emission, ranging between 1.2 and 5.8 times the model flux, that exceeds 5 sigma in significance. This is evidence for an additional low-energy spectral component in at least some bursts, or for deviations from the power-law spectral form typically used to model gamma-ray bursts at energies below 100 keV.

Preece, R. D.↗

Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles

Tissue-equivalent proportional counters (TEPCs) have been used to measure energy deposition in simulated volumes of tissue ranging in diameter from 0.1 to 10 microm. There has been some concern that the wall used to define the volume of interest could influence energy deposition within the sensitive volume because it has a density significantly greater than that of the cavity gas. These effects become important for high-velocity heavy ions. Measurements of energy deposition were made for 1 GeV/nucleon iron particles in a TEPC simulating a 1-microm-diameter sphere of tissue. The TEPC was nested within a particle spectrometer that provided identification and flight path of individual particles. Energy deposition was studied as a function of pathlength through the TEPC. Approximately 30% of the energy transfer along trajectories through the center of the detector escapes the sensitive volume. The response of the TEPC, for trajectories through the detector, is always larger than calculations for energy loss in a homogeneous medium. This enhancement is greatest for trajectories near the cavity/wall interface. An integration of the response indicates that charged-particle equilibrium is essentially achieved for a wall thickness of 2.54 mm. However, estimates of the linear energy transfer for the incident particles are influenced by these wall effects.

Non-NASA Center↗

Recent Development of Sb-based Phototransistors in the 0.9- to 2.2-microns Wavelength Range for Applications to Laser Remote Sensing

We have investigated commercially available photodiodes and also recent developed Sb-based phototransistors in order to compare their performances for applications to laser remote sensing. A custom-designed phototransistor in the 0.9- to 2.2-microns wavelength range has been developed at AstroPower and characterized at NASA Langley's Detector Characterization Laboratory. The phototransistor's performance greatly exceeds the previously reported results at this wavelength range in the literature. The detector testing included spectral response, dark current and noise measurements. Spectral response measurements were carried out to determine the responsivity at 2-microns wavelength at different bias voltages with fixed temperature; and different temperatures with fixed bias voltage. Current versus voltage characteristics were also recorded at different temperatures. Results show high responsivity of 2650 A/W corresponding to an internal gain of three orders of magnitude, and high detectivity (D*) of 3.9x10(exp 11) cm.Hz(exp 1/2)/W that is equivalent to a noise-equivalent-power of 4.6x10(exp -14) W/Hz(exp 1/2) (-4.0 V @ -20 C) with a light collecting area diameter of 200-microns. It appears that this recently developed 2-micron phototransistor's performances such as responsivity, detectivity, and gain are improved significantly as compared to the previously published APD and SAM APD using similar materials. These detectors are considered as phototransistors based-on their structures and performance characteristics and may have great potential for high sensitivity differential absorption lidar (DIAL) measurements of carbon dioxide and water vapor at 2.05-microns and 1.9-microns, respectively.

Abedin, M. Nurul↗

Ultraviolet response of InGaAsP photocathodes

Three type VPM 164 photomultiplier tubes with III-IV compound InGaAsP reflective photocathodes were developed for use in ground-based and space-borne astronomical detectors. Although the achieved response of about 0.02% quantum efficiency at 1.083 microns fell short of the goal of 1% quantum efficiency, the broadband characteristics are still considerably better than those of the S-1 photocathode.

Feibelman, W. A.↗

JPSS-2 VIIRS version 2 at-launch relative spectral response characterization

The JPSS-2 VIIRS sensor has completed its pre-launch test program and is now awaiting launch in the 2022 timeframe. The VIIRS spectral characterization, in the form of band averaged and supporting detector level relative spectral response (RSR) for each VIIRS band, was completed in 2019 and is based upon independent SpMA dual monochromator (all bands) and GSFC GLAMR laser system (reflectance bands only) spectral measurements, including first time measurements of the VIIRS SWIR bands by a laser system. The measurements and subsequent analysis effort by subject matter experts of the VIIRS DAWG has led to the July 2019 VIIRS Version 2 RSR release, the official at-launch RSR characterization for the JPSS-2 VIIRS mission. Version 2 replaces and improves upon the August 2018 Version 1 release by incorporating the GLAMR measurements into the analysis to produce an updated “fused” RSR for reflective solar bands (M1- M10, I1-I3, DNBLGS, DNBMGS) and by applying a CO2 absorption correction to the SpMA measurements for thermal band M13. For all other bands (M11, M12, M14-M16, I4, I5), the Version 1 characterization, based entirely upon the SpMA measurements, is carried forward into the Version 2 release. An assessment on compliance with spectral performance metrics finds that VIIRS is compliant on nearly all metrics, with a few minor exceptions. The version 2 RSR release includes band average (over all detectors and subsamples) RSR plus supporting RSR for each detector and subsample, and is available under EAR99 restrictions to the science community at a restricted access NASA eRoom site.

JPSS-2↗

Ge:Be infrared photoconductors

Ge:Be photoconductors were optimized for the 30 to 50 micron wavelength range. Crystal growth of detector quality material requires good control of both the Be and residual impurity doping. Detective quantum efficiencies of n sub d = 46% at 5 A/W were achieved at a photon background of 10 to the 8th power p/s. The responsivity of Ge:Be detectors can be strongly temperature-dependent when the residual shallow levels in the material are closely compensated. Transient responses on the order of approximately 1 second were observed in some materials. The role of residual shallow impurities on the performance of photoconductors doped with semi-deep and deep impurities is discussed.

Haegel, N. M.↗

Silicon solid/state linear arrays for multispectral high resolution imaging systems

Solid-state, electronically scanned, linear detector arrays are now available which can be used in a pushbroom scan mode imaging system for high-resolution multispectral earth resource survey applications. These arrays provide high performance in the visible to near-IR region. Two performance criteria must be assessed in the choice of a detector array: signal-to-noise ratio and spectral response. Consideration of diffraction limitations shows that optics size cannot be significantly reduced by using very low-noise detectors. The required spectral response for a viable detector array should not have spectral ripples that cause a low-level, but significant, error in the detected effective reflectance of the target.

Thompson, L. L.↗

X-ray detector physics and applications; Proceedings of the Meeting, San Diego, CA, July 23, 24, 1992

Recent developments in X-ray and hard X-ray imaging detector, high-intensity sources, hard X-ray imaging optics, calibration, and detection technologies are discussed. Particular attention is given to a high-MTF X-ray image intensifier, application of monolithic CdZnTe linear solid state ionization detectors for X-ray imaging, magnetic response of high-Tc superconductors to X-ray radiation and detection of X-rays, laboratory soft X-ray source with foil target, detection of explosive materials using nuclear radiation, energy response of astronomical CCD X-ray detectors, calibration techniques for high-flux X-ray detectors, fabrication of grazing-incidence optics using flow-polishing techniques, and numerical simulations for capillary-based X-ray optics. (No individual items are abstracted in this volume)

Hoover, Richard B.↗

An Experimental Study of a Radially Arranged Thin Film Heat Flux Gauge

A new thin-film heat-flux gauge was designed and fabricated on three different substrate materials. Forty pairs of Pt-Pt/10% Rh thermocouple junctions were deposited in a circular pattern on the same plane of the substrate. Over the thermocouples, 5 and 10 micron thick thermal resistance layers were deposited to create a temperature gradient across those layers. Calibration and testing of these gauges were carried out in an arc-lamp calibration facility. The heat flux calculated from the gauge output is in good agreement with the value obtained from the pre-calibrated standard sensor. A CO2 laser was also used to test the steady-state and dynamic responses of the heat-flux gauge. During the steady-state test, the time constant for the heating period was 30 s. The frequency response of the heat-flux gauge was measured in the frequency domain using a CO2 laser and a chopper. The responses from an infrared detector and the heat-flux gauge were measured simultaneously and compared. It was found that the thin-film heat-flux gauge has a dynamic frequency response of 3 kHz.

Cho, Christoper S. K.↗