Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Development of High Resolution Mirrors and Cd-Zn-Te Detectors for Hard X-ray Astronomy

We describe the fabrication and implementation of a high-resolution conical, grazing- incidence, hard X-ray (20-70 keV) telescope. When flown aboard stratospheric balloons, these mirrors are used to image cosmic sources such as supernovae, neutron stars, and quasars. The fabrication process involves generating super-polished mandrels, mirror shell electroforming, and mirror testing. The cylindrical mandrels consist of two conical segments; each segment is approximately 305 mm long. These mandrels are first, precision ground to within approx. 1.0 micron straightness along each conical segment and then lapped and polished to less than 0.5 micron straightness. Each mandrel segment is the super-polished to an average surface roughness of approx. 3.25 angstrom rms. By mirror shell replication, this combination of good figure and low surface roughness has enabled us to achieve 15 arcsec, confirmed by X-ray measurements in the Marshall Space Flight Center 102 meter test facility. To image the focused X-rays requires a focal plane detector with appropriate spatial resolution. For 15 arcsec optics of 6 meter focal length, this resolution must be around 200 microns. In addition, the detector must have a high efficiency, relatively high energy resolution, and low background. We are currently developing Cadmium-Zinc-Telluride fine-pixel detectors for this purpose. The detectors under study consist of a 16x16 pixel array with a pixel pitch of 300 microns and are 1 mm and 2 mm thick. At 60 keV, the measured energy resolution is around 2%.

Ramsey, Brian D.↗

Air fluorescence detection of large air showers below the horizon

In the interest of exploring the cosmic ray spectrum at energies greater than 10 to the 18th power eV, where flux rates at the Earth's surface drop below 100 yr(-1) km(-2) sr(-1), cosmic ray physicists have been forced to construct ever larger detectors in order to collect useful amounts of data in reasonable lengths of time. At present, the ultimate example of this trend is the Fly's Eye system in Utah, which uses the atmosphere around an array of skyward-looking photomultiplier tubes. The air acts as a scintillator to give detecting areas as large as 5000 square kilometers sr (for highest energy events). This experiment has revealed structure (and a possible cutoff) in the ultra-high energy region above 10 o the 19th power eV. The success of the Fly's Eye experiment provides impetus for continuing the development of larger detectors to make accessible even higher energies. However, due to the rapidly falling flux, a tenfold increase in observable energy would call for a hundredfold increase in the detecting area. But, the cost of expanding the Fly's Eye detecting area will approximately scale linearly with area. It is for these reasons that the authors have proposed a new approach to using the atmosphere as a scintillator; one which will require fewer photomultipliers, less hardware (thus being less extensive), yet will provide position and shower size information.

Halverson, P.↗

Thermopile Detector Arrays for Space Science Applications

Thermopile detectors are widely used in uncooled applications where small numbers of detectors are required, particularly in low-cost commercial applications or applications requiring accurate radiometry. Arrays of thermopile detectors, however, have not been developed to the extent of uncooled bolometer and pyroelectric/ferroelectric arrays. Efforts at JPL seek to remedy this deficiency by developing high performance thin-film thermopile detectors in both linear and two-dimensional formats. The linear thermopile arrays are produced by bulk micromachining and wire bonded to separate CMOS readout electronic chips. Such arrays are currently being fabricated for the Mars Climate Sounder instrument, scheduled for launch in 2005. Progress is also described towards realizing a two-dimensional thermopile array built over CMOS readout circuitry in the substrate.

Foote, M. C.↗

Superconducting Detectors Come of Age, or Ready to Leave the Lab

Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provide a mechanism for high sensitivity detection of submillil.neter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large-scale superconducting detection systems is now being deployed. Improved understanding of the operation of these detectors, combined with rapidly improving fabrication techniques, is quickly expanding the capability of these detectors. I will review the development and application of superconductor-based detectors, the ultimate limits to their performance, and consider prospects for their future applications. Continued advances promise to enable important new measurements in physics, and with appropriate advances in cryogenic infrastn~cturem, ay result in the use of these detectors in everyday monitoring applications.

Moseley, Samuel H.↗

Fabrication of an Antenna-Coupled Bolometer for Cosmic Microwave Background Polarimetry

We describe the development of a detector for precise measurements of the cosmic microwave background polarization. The detector employs a waveguide to couple light between a pair of Mo/Au superconducting transition edge sensors (TES) and a feedhorn. Incorporation of an on-chip ortho-mode transducer (OMT) results in high isolation. The OMT is micromachined and bonded to the microstrip and TES circuits in a low temperature wafer bonding process. The wafer bonding process incorporates a buried superconducting niobium layer with a single crystal silicon layer which serves as the leg isolated TES membrane and as the microstrip dielectric. We describe the micromachining and wafer bonding process and report measurement results of the microwave circuitry operating in the 29-43GHz band along with Johnson noise measurements of the TES membrane structures and development of Mo/Au TES operating under '00mK.

Denis, K.L.↗

Superconducting Al-trilayer tunnel junctions for use as X-ray detectors

Photolithographic techniques have been developed to fabricate high-quality Al-Al oxide-Al superconducting tunnel junctions for use in X-ray detectors. These devices are designed to incorporate about 1-micron-thick superconducting X-ray absorbers for the detection of less than 10-keV single photons. In an effort to increase energy resolution, superconductor bandgap engineering with lateral and vertical trapping has been used to shorten quasi-particle tunneling times and diffusion lengths and to prevent quasi-particle diffusion away from the tunnel junction. Methods that have been developed for overcoming materials imcompatibility and device degradation upon thermal cycling are reported. The authors also report on the use of a nonrectangular tunnel junction geometry which reduces the magnetic field needed to suppress the Josephson current for stable biasing. Work in progress to measure the energy resolution of these X-ray detectors at 0.35 K is also discussed.

Gaidis, M. C.↗

Charge Loss and Charge Sharing Measurements for Two Different Pixelated Cadmium-Zinc-Telluride Detectors

As part of ongoing research at Marshall Space Flight Center, Cadmium-Zinc- Telluride (CdZnTe) pixilated detectors are being developed for use at the focal plane of the High Energy Replicated Optics (HERO) telescope. HERO requires a 64x64 pixel array with a spatial resolution of around 200 microns (with a 6m focal length) and high energy resolution (< 2% at 60keV). We are currently testing smaller arrays as a necessary first step towards this goal. In this presentation, we compare charge sharing and charge loss measurements between two devices that differ both electronically and geometrically. The first device consists of a 1-mm-thick piece of CdZnTe that is sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). The signal is read out using discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe that is sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). Instead of using discrete preamplifiers, the crystal is bonded to an ASIC that provides all of the front-end electronics to each of the 256 pixels. what degree the bias voltage (i.e. the electric field) and hence the drift and diffusion coefficients affect our measurements. Further, we compare the measured results with simulated results and discuss to

Gaskin, Jessica↗

The Zero-Degree Detector System

A new detector system has been developed to measure light fragments from heavy ion fragmentation reactions. The detector system separately measures the signals from simultaneous fragments.

Adams, James H., Jr.↗

Submillimeter Spectroscopy with a 500-1000 GHz SIS Receiver

Sub-millimeter Spectroscopy with a 500-1000 GHz SIS Receiver, which extended over the period October 1, 1991 through January 31, 1997. The purpose of the grant was to fund the development and construction of a sensitive heterodyne receiver system for the submillimeter band (500-1000 GHz), using our newly-developed sensitive superconducting (SIS) detectors, and to carry out astronomical observations with this system aboard the NASA Kuiper Air- borne Observatory (a Lockheed C-141 aircraft carrying a 91 cm telescope). A secondary purpose of the grant was to stimulate the continued development of sensitive submillimeter detectors, in order to prepare for the next-generation airborne observatory, SOFIA, as well as future space missions (such as the ESA/NASA FIRST mission).

Zmuidzinas, J.↗

New technologies for UV detectors

Several technologies are currently being developed, leading to substantial improvements in the performance of UV detectors or significant reductions in power or weight. Four technologies discussed are (1) thin-film coatings to enhance the UV sensitivity of CCD's, (2) highly innovative magnet assemblies that dramatically reduce weight and result in virtually no external flux, (3) new techniques for curving microchannel plates (MCP's) so that single plates can be used to prevent ion feedback and present highly localized charge clouds to an anode structure, and (4) high-performance alternatives to glass-based MCP's. In item (2), for example, very robust magnets are made out of rare earth materials such as samarium cobalt, and cladding magnets are employed to prevent flux from escaping from the detector into the external environment. These new ultralight magnet assemblies are able to create strong, exceptionally uniform magnetic fields for image intensification and focusing of photoelectrons. The principle advantage of such detectors is the quantum efficiencies of 70-80 percent obtained throughout ultraviolet wavelengths (900-2000 A), the highest of any device. Despite the improvements achieved under item (3), high-performance alternatives to conventional glass-based MCP's potentially offer three distinct new advantages that include (1) a 30-100-fold improvement in dynamic range resulting in correspondingly higher signal-to-noise ratios, (2) the use of pure dielectric and semiconductor materials that will not outgas contaminants that eventually destroy photocathodes, and (3) channels that have constant spacing providing long-ranged order since the plates are made using photolithography techniques from the semiconductor industry. The manufacturers of these advanced-technology MCP's, however, are a couple of years away from actually producing a functioning image intensifier. In contrast to the use of CCD's for optical, ground based observations, there is no single detector technology in the ultraviolet that dominates or is as universally suitable for all applications. Thus, several technological problems, recent advances, and the impact that these new enabling technologies represent for UV applications are addressed.

Joseph, C. L.↗

STRV RADMON: An integrated high-energy particle detector

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude. On the STRV (Space Technology Research Vehicle) the RADMON's SRAM will be used to detect trapped protons, solar flares, and cosmic rays and to evaluate our ability to predict space results from ground tests.

Buehler, Martin↗

STRV RADMON: An Integrated High-Energy Particle Detector

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude.

RADMON↗

Development of a TES-Based Anti-Coincidence Detector for Future X-ray Observatories

Microcalorimeters onboard future x-ray observatories require an anti-coincidence detector to remove environmental backgrounds. In order to most effectively integrate this anticoincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We will present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine↗

Development of a TES-Based Anti-Coincidence Detector for Future X-Ray Observations

Microcalorimeters onboard future x-ray observatories require an anticoincidence detector to remove environmental backgrounds. In order to most effectively integrate this anti-coincidence detector with the main microcalorimeter array, both instruments should use similar read-out technology. The detectors used in the Cryogenic Dark Matter Search (CDMS) use a phonon measurement technique that is well suited for an anti-coincidence detector with a microcalorimeter array using SQUID readout. This technique works by using a transition-edge sensor (TES) connected to superconducting collection fins to measure the athermal phonon signal produced when an event occurs in the substrate crystal. Energy from the event propagates through the crystal to the superconducting collection fins, creating quasiparticles, which are then trapped as they enter the TES where they produce a signal. We are currently developing a prototype anti-coincidence detector for future x-ray missions and have recently fabricated test devices with Mo/Au TESs and Al collection fins. We present results from the first tests of these devices which indicate a proof of concept that quasiparticle trapping is occurring in these materials.

Bailey, Catherine N.↗

Roll angle detector.

Description of a roll angle detector system under development that is designed to measure the relative roll angle of two independent bodies to a high degree of precision. The system involves the imaging of a very small aperture by an optical system on one body onto the surface of the other. A review of the underlying mathematical principle, is followed by an optical-mechanical and electrical description of the system and a listing of several important sources of measurement errors. The ultimate achievement of an accuracy of plus or minus 5 arc seconds is expected.

Lowen, I.↗

Side-viewing detector for a vacuum ultraviolet reflectometer.

The problem of detector response, which arises in the application of the reflectance vs angle of incidence method to the determination of optical constants in the vacuum UV spectral region is discussed. The analysis is performed for the side-viewing 1P21 detector sensitized with sodium salycilate. To take advantage of the wide selection photomultipliers available in the end-on configuration, a scheme for converting the end-on types to a side viewing geometry with a response uniform over several degrees of detector rotation is developed. It consists of a 32-mm diam spherical collector, located at the end of a cylindrical photomultiplier holder, with 12-mm entrance and viewing ports and a position for the sensitized screen also 12-mm in diameter.-

Osantowski, J. F.↗

Cosmic ray experimental observations

The current experimental situation in cosmic ray studies is discussed, with special emphasis on the development of new detector systems. Topics covered are the techniques for particle identification, energy measurements, gas Cerenkov counters, magnet spectrometers, ionization spectrometers, track detectors, nuclear emulsions, multiparameter analysis using arrays of detectors, the Goddard ionization spectrometer, charge spectra, relative abundances, isotope composition, antinuclei in cosmic rays, electrons, the measurement of cosmic ray arrival directions, and the prehistory of cosmic rays.

Balasubrahmanyan, V. K.↗