Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Quasi-Lagrangian measurements of density surface fluctuations and power spectra in the stratosphere

Pressure and temperature data from eight superpressure balloon flights at 26 km in the southern hemisphere stratosphere are analyzed. The balloons, which float on a constant density surface, travel steadily westward during summer and eastward during winter, as expected from local climatology. Two types of fluctuations are observed: neutral buoyancy oscillations (NBO) of around 4 min, and 0.1- to 1-hour oscillations that are characterized as small-amplitude density surface fluctuations. Lapse rates and densities are calculated and found to agree well with the expected values. Examples of wave damping and simultaneous fluctuation at two nearby balloons are presented. Spectral analysis is performed clearly showing the NBO and that the majority of the power is in the mesoscale range. Spectral slopes of power versus frequency are measured to be on the average -2.18 + or - 0.24 for pressure and -1.72 + or - 0.24 for temperature. These slopes are compared to the predictions of turbulence theories and the theory of a universal gravity wave spectrum.

Quinn, Elizabeth P.↗

Thermally induced damage in composite space structure: Predictive methodology and experimental correlation

A general analysis method is presented to predict matrix cracks in all plies of a composite laminate, and resulting degraded laminate properties, as functions of temperature or thermal cycles. A shear lag solution of the stresses in the vicinity of cracks and a fracture mechanics crack formation criteria are used to predict cracks. Damage is modeled incrementally, which allows the inclusion of the effects of temperature dependent material properties and softening of the laminate due to previous cracking. The analysis is incorporated into an easy-to-use computer program. The analysis is correlated with experimentally measured crack densities in a variety of laminates exposed to monotonically decreasing temperatures. Crack densities are measured at the edges of specimens by microscopic inspection, and throughout the specimen volumes by x-ray and sanding down of the edges. Correlation between the analytical results and the crack densities in the interiors of the specimens was quite good. Crack densities measured at specimen edges did not agree with internal crack densities (or analyses) in some cases. A free-edge stress analysis clarified the reasons for these discrepancies.

Park, Cecelia↗

Positive-feedback photometric drift in the PDS

Digitizing flatfield images produces conditions in the Photometric Data System PDS which cause the measured density to drift by as much as .1 DN during a 10 minute interval. The drift occurs when the PDS, set up in equilibrium at fog level, subsequently scans a reasonably dense region for periods of longer than a few minutes. The drift is manifested primarily as a positive shift in density that is approximately the same for all densities. If the fog level is assumed to be in fact constant and is monitored during scans of flat fields, the PDS drift may be removed by subtracting the difference between the observed fog level and its assumed constant value for each pixel. This function is then smoothed and subtracted, as a function of scan line, from the measured density. The fog level is then adjusted to a standard value by adding a constant. The result is a flattened scan with PDS drift removed to the accuracy within which the fog level drift matches the drift at other levels.

Cornett, R. H.↗

Photoconductivity of high-voltage space insulating materials

The dark and photoconductivities of four high voltage spacecraft insulators, Kapton-H, FEP Teflon, Parylene, and fused quartz, were studied under a variety of conditions intended to simulate a space environment. All measurements were made in a vacuum of less than .00001 torr while the temperature was varied from 22 C to 100 C. Some of the samples used employed conventional deposited metal electrodes--others employed electrodes composed either of an electron beam or a plasma formed by ionization of the residual gas in the test chamber. Test results show: (1) Kapton had unusual conduction properties; it conductivity decreased by more than an order of magnitude when heated at 100 C in a vacuum, but ultimately attained a stable and reproducible value. (2) Both Teflon and fused quartz had high dark resistivities but low photoresistivities when exposed to UV. Optical-density measurements revealed that both materials transmitted UV with little attenuation. (3) Parylene was found to have a low but relatively stable resistivity--comparatively minor changes occurred upon heating or illuminating the sample. Optical-density measurements showed that Parylene was absorbent in the UV and would prevent photoemission from the metal electrode on the back surface.

Coffey, H. T.↗

Design, fabrication and calibration of alpha particle densitometers for measuring planetary atmospheric density

An alpha particle densitometer was developed for possible application to measurement of the atmospheric density-altitude profile on Martian entry. The device uses an Am-241 radioactive-foil source, which emits a distributed energy spectrum, located about 25 to 75 cm from a semiconductor detector. System response - defined as the number of alphas per second reaching the detector with energy above a fixed threshold - is given for Ar and CO2. The altitude profile of density measurement accuracy is given for a pure CO2 atmosphere with 5 mb surface pressure. The entire unit, including dc-dc converters, requires less than 350 milliwatts of power from +28 volts, weighs about 0.85 lb and occupies less than 15 cubic inches volume.

Sellers, B.↗

Dark Energy Survey Year 1 Results: Cosmological Constraints from Cluster Abundances, Weak Lensing, and Galaxy Correlations

We present the first joint analysis of cluster abundances and auto or cross-correlations of three cosmic tracer fields: galaxy density, weak gravitational lensing shear, and cluster density split by optical richness. From a joint analysis (4×2pt+N) of cluster abundances, three cluster cross-correlations, and the auto correlations of the galaxy density measured from the first year data of the Dark Energy Survey, we obtain Ωm=0.305-0.038+0.055 and σ8=0.783-0.054+0.064. This result is consistent with constraints from the DES-Y1 galaxy clustering and weak lensing two-point correlation functions for the flat νΛCDM model. Consequently, we combine cluster abundances and all two-point correlations from across all three cosmic tracer fields (6×2pt+N) and find improved constraints on cosmological parameters as well as on the cluster observable-mass scaling relation. This analysis is an important advance in both optical cluster cosmology and multiprobe analyses of upcoming wide imaging surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial profile of argon (1s 5 ) metastables in an electron beam generated plasma

Electron beams with an applied magnetic field generate a secondary cold plasma with a selective chemical composition, featuring low-energy ions and metastable species in the discharge periphery, ideal for low-damage plasma treatment of material substrates. In this work, we studied the plasma generated by an e-beam using a 4 kV voltage in a pure argon gas environment under a magnetic field of 150 G and in the pressure range of 25–90 mTorr. We measured the absolute spatial density profile of argon (1 s 5 ) metastables in an electron beam generated plasma by laser-induced fluorescence and found it to be of the order of 10 16 m −3 . The electron temperature and the electron density measured by a Langmuir probe were of the order of 10 16 m −3 and less than an eV respectively. Electron-impact quenching was identified as a significant loss mechanism for the Ar(1s 5 ) state, leading to the saturation of the metastable density at higher pressures. Outside the primary ionization region, the spatial distribution of argon metastables followed a linear diffusion profile, indicating negligible additional production in those regions.

EEDF↗

Multi-Point Line Focused Laser Differential Interferometer for High-Speed Flow Fluctuation Measurements

A multi-point focused laser differential interferometer (FLDI) has been developed to measure density fluctuations at 16 points along a line. A pair of cylindrical lenses on the transmitter side of a conventional single-point FLDI instrument form two closely spaced (≤200 μm), orthogonally polarized, parallel laser lines at the instrument’s focus. On the receiver side of the instrument, the interference of the beams on a 16-element photodiode array results in a single line of measurements. The further addition of a Nomarski prism creates two separate measurement lines, and the addition of a second photodiode array to the instrument enables simultaneous measurements of density fluctuations along the two lines separated by several millimeters. These two lines of measurement can be conveniently oriented at any azimuthal angle relative to the instrument’s optical axis on the measurement plane, coinciding with the instrument’s focus. Two experiments were performed to demonstrate the capabilities of the instrument. In the first experiment, a laser-induced breakdown spark generated a traveling spherical shock wave, and measurements of the resulting density disturbance and wave velocity were obtained. These results were compared to high-speed schlieren images of the shock wave acquired at 400 kHz. In the second experiment, the multi-point FLDI instrument was used to measure density disturbances in the boundary layer of a flat plate in a Mach 6 freestream flow. The measurements were made along two lines, both approximately 6 mm in length, extending from the surface of the plate through the boundary layer. High-speed schlieren images were acquired at 100 kHz during separate wind tunnel runs at matching unit Reynolds numbers to visualize the unsteady boundary layer flow and compare to the FLDI measurements.

Laser beam shaping↗

A New Probe of the Molecular Gas Content in Galaxies: Application to M101

Studies of nearby spiral galaxies suggest that photodissociation regions (PDRs) are capable of producing the observed large--scale distribution of HI (Allen et al.- 1997, and references therein). The column density of HI in a PDR is fundamentally linked to the amount of far--ultraviolet (FUV) emission produced by nearby young stars and the local molecular gas volume density. Measurements of the HI column density and the FUV emission associated with PDRs thus provide a new probe of the molecular gas distribution in nearby galaxies. Advantages of this method include its insensitivity to assumptions about the CO/{\rm H2} conversion factor or the gas temperature. We discuss the application of this method to M101. The HI column density and FUV emission have been measured for 35 PDRs from VLA data (Braun 1997) and Ultraviolet Imaging Telescope data (Waller et al.-1997). We derive volume densities ranging from n-100 {\rm cm(exp -3)} in the central HI--poor regions of M101 to n -3000 {\rm cm(exp -3)} in the HI--rich periphery of the galaxy.

Smith, D. A.↗

Nonlinear interactions of electromagnetic waves with a thermally generated cesium plasma.

The interaction of a large‐amplitude disturbing wave with a thermally generated, highly ionized cesium plasma has been investigated using a small‐amplitude sensing wave as a probe. The subsequent interaction between the disturbing and sensing waves is related to the plasma electron temperature. The plasma was contained in a magnetic field of 500–1000 G and had an electron plasma frequency near 10 GHz and an electron gyromagnetic frequency around 2 GHz. The sensing wave was a 10 GHz plane wave of approximately 1.5 mW input power and the disturbing wave was 7.5 GHz plane wave of about 1.2 W peak power. Measurements of the sensing‐wave transmitted power were made using standard microwave techniques. A notch filter in the sensing‐wave receiving circuit reduced the scattered disturbing‐wave interference to an immeasurably low level. Langmuir probes were used to detect disturbing‐wave modulation and to measure plasma temperatures and densities. Measurements of the interaction were correlated with a solution of the Boltzmann transport equation for a perturbed Maxwellian distribution function with binary Coulomb collisions.

Jack G Hewitt, Jr↗

Measurement of density and porosity of lunar rocks based on samples of Luna 16 automatic lunar station

Three fragments of holocrystalline igneous rocks of the gabbro type, weighing 30 to 50 mg each, were investigated. The density of the fragments was established with a mercury pycnometer and was found to be 3.05 to 3.12 g/cu cm, with a relative error not more than 2 percent. The porosity was found for the difference between the volumes determined with the mercury and with the gas techniques; for all three samples together it was 13 percent, and the error of determination was 70 percent owing to the small volumes. It can be anticipated that the porosity of the rock in bulk will be higher than the value obtained based on small fragments. The porosity of lunar rocks can markedly affect the isostatic distribution of rocks and must be taken into account when developing models of lunar structure.

Volynets, V. F.↗