Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cyclotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Parallelized real-time physics codes for plasma control on DIII-D

A real-time safe multi-threading library was developed on the DIII-D plasma control system to optimize the real-time TORBEAM and real-time STRIDE physics codes. These physics codes are crucial for future fusion power plant operation as they provide information about electron cyclotron wave propagation and heating as well as inform about ideal plasma stability limits. The real-time TORBEAM code executed consistently in under 20 ms while the real-time STRIDE code computes in 100 ms. The multi-threading library developed in this work can be applied to other real-time physics-based codes that will be crucial for the next generation of fusion devices.

DIII-D↗

Real-time plasma monitoring framework for advanced plasma control and ML-research in DIII-D

Real-time and adaptive plasma control is crucial for robust tokamak operation, requiring sensitivity and tolerance measurements of the plasma state. This paper presents the implementation of an integrated real-time plasma monitoring framework on the DIII-D tokamak to support advanced control approaches, including machine-learning (ML) methods. The system is built on the SHIELD framework, a high-performance modular architecture that provides a unified pipeline for integrating diverse diagnostics. The framework leverages high-bandwidth digitizers, fast numerical processing, and deterministic, low-latency interconnects to stream high-fidelity data from diagnostics such as electron cyclotron emission (ECE), beam emission spectroscopy (BES), CO interferometers, and a visible tangential divertor camera (TangTV). The system’s validity is demonstrated through direct comparisons of real-time and offline data. Furthermore, we present two key applications of the developed plasma monitoring system with ML-based plasma control strategies, including real-time divertor detachment and active Alfvén Eigenmode control. As a result, this work presents a robust and scalable approach for integrating high-frequency, multidimensional diagnostics into advanced control algorithms for future fusion devices.

AI/ML↗

Composition and persistence of soil organic matter along eroding and depositional transects in buried vs. modern soil layers: A case of the Brady paleosol at Wauneta, Nebraska

Paleosols form when soils are buried through deposition by aeolian, colluvial, alluvial or other processes. Burial of former topsoil isolates soil organic matter (SOM) from surface conditions, allowing carbon to accumulate and potentially remain stable for millennia. In this study, SOM composition, distribution, and persistence were analyzed in the Brady Soil of Nebraska, USA to compare SOM spatial variability in modern and buried soils, as well as the impact of erosional exposure on SOM stability. The Brady Soil, formed as a surface soil during the Pleistocene-Holocene transition and now a paleosol buried up to 6 m deep (or more) by loess deposition during the Holocene, was sampled along burial (up to 5.8 m depth) and erosional (up to 1.8 m depth) transects to compare SOM dynamics in different geomorphic settings. Fourier Transform Infrared Spectroscopy (FTIR) and Fourier Transform ion cyclotron resonance mass spectrometry (FTICR-MS) were used to analyze SOM composition, while δ 13 C isotope analyses identified SOM sources and radiocarbon values were used to estimate turnover rates. Results confirmed a vegetation shift from C3 to C4 plants after Brady Soil formation, reflecting warming climatic conditions. Increasing SOM age and decreasing δ 13 C and δ 15 N values with depth indicated slowing of decomposition rate in buried soils. Higher pH in the Brady Soil suggested greater base cation content, supporting SOM stabilization through organo-mineral associations and aggregate formation. However, exposure of the Brady Soil due to surface erosion caused faster SOM turnover. This result suggested susceptibility of buried SOM to losses via decomposition upon erosional exposure, possibly accelerated by priming in response to modern SOM inputs. These findings highlight the potential loss of carbon stocks in buried soils under future climate change, as shifts in soil physicochemical properties may destabilize long-preserved SOM.

Environmental sciences↗

The impact of cold electrons and cold ions in magnetospheric physics

A review of the impact of the cold-ion and cold-electron populations in the Earth’s magnetosphere is presented in this paper. The cold populations are defined by total energy less than approximately 100 eV, i.e. in the energy range which is strongly affected by spacecraft charging and that often dominates the total plasma density. We also include the warm plasma cloak in the review, since it overlaps partially with the cold energy range and is a population that is still not well understood. The known impacts of cold ions and cold electrons that are discussed are: the source of magnetospheric plasma, solar-wind/magnetosphere coupling, magnetotail reconnection and substorms, Kelvin-Helmholtz instabilities at the magnetopause, chorus, hiss, electromagnetic-ion-cyclotron and ultra-low-frequency wave-particle interactions, aurora structuring and spacecraft charging. Other possible impacts are associated with refilling on open-drift trajectories, the remnant layer and plasmapause disruption. A discussion of the difficulty of cold-plasma measurements and the need for new measurement techniques that measure the full cold-ion and cold-electron distribution functions is also presented. There remain a lot of unknowns about the cold-ion and cold-electron populations, associated with their origin, properties, drivers and impacts. These populations will need to be fully understood before the magnetosphere-ionosphere system can be fully understood.

79 ASTRONOMY AND ASTROPHYSICS↗

Exact and locally implicit source term solvers for multifluid-Maxwell systems

Recently, a family of models that couple multifluid systems to the full Maxwell equations have been used in laboratory, space, and astrophysical plasma modeling. These models are more complete descriptions of the plasma than reduced models like magnetohydrodynamic (MHD) since they are derived more closely from the full kinetic Vlasov-Maxwell system, without assumptions like quasi-neutrality, negligible electron mass, etc. Thus these models naturally retain non-ideal MHD effects like electron inertia, Hall term, pressure anisotropy/nongyrotropy, displacement current, among others. One obstacle to broader application of these model is that an explicit treatment of their source terms leads to the need to resolve rapid processes like plasma oscillation and electron cyclotron motion, even when these are not important. In this paper, we suggest two ways to address this issue. First, we derive the analytic solutions to the source update equations, which can be implemented as a practical, but less generic solver. We then develop a time-centered, locally implicit algorithm to update the source terms, allowing stepping over the fast kinetic time-scales. For a plasma with S species, the locally implicit algorithm involves inverting a local (3 S + 3) × (3 S + 3) matrix only, thus is very efficient. The performance can be further increased by using the direct update formulas to skip null calculations. In this paper, we present benchmarks illustrating the exact energy-conservation of the locally implicit solver, as well as its efficiency and robustness for both small-scale, idealized problems and largescale, complex systems. The locally implicit algorithm can be also easily extended to include other local sources, like collisions and ionization, which are difficult to solve analytically.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Presence of aromatic-rich organic matter and its characterization in grout materials: Implications for radionuclide immobilization

Grout materials are commonly used to immobilize low-level radioactive waste. Organic moieties can be unintentionally present in common ingredients used to make these grout waste forms, which may result in the formation of organo-radionuclide species. These species can positively or negatively affect the immobilization efficiency. However, the presence of organic carbon compounds is rarely considered in models or characterized chemically. Here, we quantify the organic pool of grout formulations with and without slag, as well as the individual dry ingredients used to make the grout samples (ordinary Portland cement (OPC), slag and fly ash), including total organic carbon (TOC) and black carbon, followed by aromaticity evaluation and molecular characterization via Electro Spray Ionization Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (ESI-FTICRMS). All dry grout ingredients contained significant amounts of organic carbon, ranging from 550 mg/kg to 6250 mg/kg for the TOC pool, with an averaged abundance of 2933 ± 2537 mg/kg, of which 60 ± 29% was composed of black carbon. The significant abundance of a black carbon pool implies the presence of the aromatic-like compounds, which was further identified by both phosphate buffer-assisted aromaticity evaluation (e.g., >1000 mg-C/kg as aromatic-like carbon in the OPC) and dichloromethane (DCM) extraction with ESIFTICRMS analysis. Besides aromatic-like compounds, other organic moieties were also detected in the OPC, such as carboxyl-containing aliphatic molecules. While the organic compound only consists of minor fractions of the grout materials investigated, our observations of the presence of various radionuclide-binding organic moieties suggests the potential formation of organo-radionuclides, such as radioiodine, which might be present at lower molar concentrations than TOC. Here, evaluating the role of organic carbon complexation in controlling the disposed radionuclides, especially for those radionuclides with strong association with organic carbon, has important implications for the long-term immobilization of radioactive waste in grout systems.

36 MATERIALS SCIENCE↗

Fermi surface origin of the low-temperature magnetoresistance anomaly

Magnetoresistance (MR) at a fixed field can demonstrate a non-monotonic temperature dependence—an anomaly—in many systems, including low-dimensional chalcogenides, spin- and charge-density-wave metals, and topological semimetals. These systems are often low-carrier-density compensated metals, and the physics are expected to be quasi-classical. Nevertheless, the MR anomaly also exists in the highly conductive metals Cr, Mo, and W for both linear and quadratic field dependence, with their non-saturation attributed to either open orbit or electron-hole compensation. We argue that quantum transport across sharp Fermi surface arcs, but not necessarily the full cyclotron orbit, governs this MR anomaly, thereby accounting for the profound effects of disorder. In Cr, an overlay exists between three temperature dependences: MR at a constant high field, linear MR at a low field, and Shubnikov-de Haas (SdH) oscillations of the smallest orbit. In Mo, the MR anomaly extends beyond the temperature of its SdH oscillations but disappears before Kohler’s scaling reemerges.

Feng, Yejun [Okinawa Institute of Science and Tech↗

Plastic scintillation detectors for time-of-flight mass measurements

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting Cyclotron Laboratory (NSCL) by increasing the number of photomultiplier tubes that read out their light signals to four per detector, and characterized them in a test experiment with 48 Ca beam at the NSCL. The new detectors achieved a time resolution (σ) of 7.5 ps. We systematically investigated different factors that affect their timing performance. In addition, we evaluated the ability of positioning the hitting points on the scintillator using the timing information and obtained a resolution (σ) below 1 mm for well-defined beam spots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

UCGretina geant4 simulation of the GRETINA Gamma-Ray Energy Tracking Array

UCGretina, a geant4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton continuum. Both of these features are needed in order to accurately extract gamma-ray yields from spectra collected in in-beam gamma-ray spectroscopy measurements with beams traveling at v / c ≳0.3 at the National Superconducting Cyclotron Laboratory and the Facility for Rare Isotope Beams. In the process of developing the model, we determined that millimeter-scale layers of passive germanium surrounding the active volumes of the simulated crystals must be included in order to reproduce measured photopeak efficiencies. In conclusion, we adopted a simple model of effective passive layers and developed heuristic methods of determining passive-layer thicknesses by comparison of simulations and measurements for a single crystal and for the full array. Prospects for future development of the model are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DGFRS-2—A gas-filled recoil separator for the Dubna Super Heavy Element Factory

The main goal of development of the new Dubna Gas-Filled Recoil Separator (DGFRS-2) is to sufficiently improve the efficiency of studies on heavy and superheavy nuclei at the Super Heavy Element Factory of the Flerov Laboratory of Nuclear Reactions (FLNR) at the Joint Institute for Nuclear Research. The use of beams with the intensity up to 6×10 13 s -1 (10 pμA) delivered by the DC280 cyclotron requires an effective setup providing high suppression of background reaction products. Additionally, the described gas-filled separator is optimized for synthesis and study of heavy isotopes produced in complete fusion reactions of massive nuclei. Basic characteristics of DGFRS-2, as well as the results of the first test experiments, are presented. In comparison to the DGFRS-1, the transmission efficiency was doubled, and the background was reduced by a factor 200.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BlueSTEAl: A pair of silicon arrays and a zero-degree phoswich detector for studies of scattering and reactions in inverse kinematics

BlueSTEAl, the Blue (aluminum chamber of) Silicon TElescope Arrays for light nuclei, has been developed to study direct reactions in inverse kinematics, as well as scattering and breakup reactions using radioactive ion beams. It is a detector system consisting of a pair of annular silicon detector arrays and a zero-degree phoswich plastic scintillator. For typical binary reaction studies in inverse kinematics, light ions are detected by the Si array in coincidence with heavy recoils detected by the phoswich placed at the focal-plane of a zero-degree magnetic spectrometer. The Si array can also be used to detect light nuclei such as beryllium and carbon with clear isotope separation, while the phoswich can also be placed at zero degrees without a spectrometer and used as a high-efficiency beam counting monitor with particle identification capability at the rate of up to ~5 × 10 4 particles per second. This paper reports on the capabilities of BlueSTEAl as determined by recent experiments performed at the Texas A&M Cyclotron Institute. Furthermore, the device is also anticipated to be used in future experiments at other radioactive ion beam facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GENESIS: Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering

Improved neutron inelastic scattering cross section data are needed to inform integral benchmark studies and advance applications in a wide variety of areas including nuclear energy, stockpile stewardship, nonproliferation, and space exploration. Neutron inelastic scattering also serves as a non-selective probe of low-lying nuclear structure. To help meet these needs, the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) was constructed at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. This array couples high-resolution γ-ray detectors and fast neutron detectors to achieve single and coincident n/γ detection over a broad energy range. The current configuration of the array includes 26 organic liquid scintillators and four high-purity germanium detectors (two single-crystal and two four-crystal CLOVER detectors with two-fold segmentation). The array was constructed with minimal supporting material and designed to cover a wide range of secondary particle angles and energies with limited inter-element scattering. Data acquisition is accomplished using Mesytec MDPP-16 multi-channel high-resolution digital pulse processing modules. The array characteristics, including γ-ray and neutron energy resolution, timing resolution, and detection efficiency were measured and used to validate a Geant4 model of the array. Furthermore, the primary sources of neutron background and the uncertainties in the determination of incident and secondary neutron energy were assessed. GENESIS provides a new capability to address nuclear data needs and facilitates the advancement of a wide range of nuclear applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83m Kr are detected via their ≈26 GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲10 ms and changing in frequency by ≲1 MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100 MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. Finally, we describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Data acquisition↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Durability test of a flowing-water target for isotope harvesting

A high intensity proton irradiation was performed with the flowing-water isotope harvesting target at the University of Wisconsin-Madison Cyclotron Laboratory to measure the rate of degradation of the target shell during irradiation conditions. The beam reached an intensity of 34 µA by the end of the irradiation and covered an area of 0.7 cm 2 on the target. Radiolysis products, such as H 2 O 2 , H 2 , and O 2 , were measured in the bulk water of the system and found to be present at much lower levels than predicted by literature escape yields. Radionuclides formed in the target shell were measured in the system water as a radiotracer for target degradation. Using a simple, beam intensity dependent model, a corrosion rate of 1.5E-6 μm/(μA*s) was found to match the measured radiotracer activities at various points in the irradiation. Furthermore, this rate was used to extrapolate the lifetime of future isotope harvesting targets at the NSCL and FRIB, using the areal power density of different ion beams to scale the corrosion rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗