Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Carbide/fluoride/silver self-lubricating composite

A self-lubricating, friction and wear reducing composite material for use over a wide temperature spectrum from cryogenic temperature to about 900.degree. C. in a chemically reactive environment comprising silver, barium fluoride/calcium fluoride eutectic, and metal bonded chromium carbide.

Sliney, Harold E.↗

Characterization of Low Noise, Precision Voltage Reference REF5025-HT Under Extreme Temperatures

The performance of Texas Instruments precision voltage reference REF5025-HT was assessed under extreme temperatures. This low noise, 2.5 V output chip is suitable for use in high temperature down-hole drilling applications, but no data existed on its performance at cryogenic temperatures. The device was characterized in terms of output voltage and supply current at different input voltage levels as a function of temperature between +210 C and -190 C. Line and load regulation characteristics were also established at six load levels and at different temperatures. Restart capability at extreme temperatures and the effects of thermal cycling, covering the test temperature range, on its operation and stability were also investigated. Under no load condition, the voltage reference chip exhibited good stability in its output over the temperature range of -50 C to +200 C. Outside that temperature range, output voltage did change as temperature was changed. For example, at the extreme temperatures of +210 C and - 190 C, the output level dropped to 2.43 V and 2.32 V, respectively as compared to the nominal value of 2.5 V. At cryogenic test temperatures of -100 C and -150 C the output voltage dropped by about 20%. The quiescent supply current of the voltage reference varied slightly with temperature but remained close to its specified value. In terms of line regulation, the device exhibited excellent stability between -50 C and +150 C over the entire input voltage range and load levels. At the other test temperatures, however, while line regulation became poor at cryogenic temperatures of -100 C and below, it suffered slight degradation at the extreme high temperature but only at the high load level of 10 mA. The voltage reference also exhibited very good load regulation with temperature down to -100 C, but its output dropped sharply at +210 C only at the heavy load of 10 mA. The semiconductor chip was able restart at the extreme temperatures of -190 C and +210 C, and the limited thermal cycling did not influence its characteristics and had no impact on its packaging as no structural or physical damage was observed.

Patterson, Richard↗

Characterization of Lunar Polar Volatiles for Curation and ISRU - Executive Summary

The goal of this project is to support lunar exploration by simulating and characterizing ice and volatile-rich materials expected to be found at the lunar poles. These materials are highly sensitive to heating, which could significantly alter their composition and prevent scientific studies on lunar samples. During FY19, we obtained materials for and designed a simulated lunar environment, within which volatile-rich simulant could be made. We also refined the procedure for moderate-fidelity lunar simulants at cryogenic temperatures. In FY20, we completed our test setup, and we can now reach cryogenic temperatures and near-lunar pressures with active compositional monitoring of volatiles in the vapor phase. For FY21, we: 1) progressed towards developing sample storage temperature requirements for volatile-rich samples by completing storage testing, along with materials testing for Artemis geologic sampling, 2) obtained instrumentation for solid sample monitoring to characterize solid species, and 3) progressed towards water extraction testing for ISRU. Our test results will directly feed into Artemis science requirements, hardware designs for sample return, vehicle requirements (HLS, Gateway, Orion), and operations planning for lunar exploration activities.

Julie L Mitchell↗

Cryogenic Curation of Lunar Samples Returned to Earth

Future lunar missions may collect samples that have been preserved at sub-freezing or even cryogenic temperatures. For such samples, the study of volatiles and temperature-sensitive minerals will have high priority. Valuable geochemical and mineralogical information will be lost if such samples are allowed to reach ambient temperatures on Earth. The ability to store, document, subdivide, and transport extraterrestrial geologic samples while maintaining sub-freezing or cryogenic temperatures, possibly as low as 40 K, is required for the complete scientific study of samples from cold environments. A lunar cryogenic sample return mission might require a combination of passive cooling during collection and cruise and active cooling during and after re-entry for maintaining desired temperatures. Once on Earth, cryocontainment must be maintained through delivery to a cryogenic chamber in the curatorial facility. This cryogenic curation chamber would include cameras and robotic manipulators for preliminary examination, subdivision of samples, and specialized sample allocation containers for shipment to laboratories world-wide. This presentation describes the planning and feasibility of cryogenic curation with current technologies developed for the superconductor industry. In addition, significant advanced research and development would be required to tailor some of these technologies to the task of sample return and long term curation of lunar samples at low temperatures in order to preserve their scientific integrity.

Calaway, Michael J.↗

Progress in the Fabrication and Testing of Telescope Mirrors for the James Webb Space Telescope

The telescope of the James Webb Space Telescope (JWST) is an f/20, three mirror anastigmat design, passively cooled (40K) in an L2 orbit. The design provides diffraction limited performance (Strehl > or = 0.8) at .=2 m. To fit within the launch vehicle envelope (Arianne V), the 6.6 meter primary mirror and the secondary mirror support structure are folded for launch, then deployed and aligned in space. The primary mirror is composed of 18 individual, 1.3 meter (flat flat) hexagonal segments, each adjustable in seven degrees of freedom (six rigid body + radius of curvature) provided by a set of high precision actuators. The actuated secondary mirror (approx.0.74m) is similarly positioned in six degrees of rigid body motion. The approx..70x.51m, fixed tertiary and approx. 0.17m, flat fine steering mirror complete the telescope mirror complement. The telescope is supported by a composite structure optimized for performance at cryogenic temperatures. All telescope mirrors are made of Be with substantial light-weighting (21 kg for each 1.3M primary segment). Additional Be mounting and supporting structure for the high precision (approx.10nm steps) actuators are attached to the primary segments and secondary mirror. All mirrors undergo a process of thermal stabilization to reduce stress. An extensive series of interferometric measurements guide each step of the polishing process. Final polishing must account for any deformation between the ambient temperature of polishing and the cryogenic, operational temperature. This is accomplished by producing highly precise, cryo deformation target maps of each surface which are incorporated into the final polishing cycle. All flight mirrors have now completed polishing, coating with protected Au and final cryo testing, and the telescope is on track to meet all system requirements. We here review the measured performance of the component mirrors and the predicted performance of the flight telescope.

Bowers, Charles↗

Fluid mass and thermal loading effects on the modal characteristics of space shuttle main engine liquid oxygen inlet splitter vanes

An analysis and evaluation of experimental modal survey test data on the variations of modal characteristics induced by pressure and thermal loading events are presented. Extensive modal survey tests were carried out on a Space Shuttle Main Engine (SSME) test article using liquid nitrogen under cryogenic temperatures and high pressures. The results suggest that an increase of pressure under constant cryogenic temperature or a decrease of temperature under high pressure induces an upward shift of frequencies of various modes of the structures.

Panossian, H. V.↗

Effect of low temperature on fatigue and fracture properties of Ti-5Al-2.5Sn(ELI) for use in engine components

Experiments were conducted to evaluate the characteristics of the Ti-5Al-2.5Sn (ELI) alloy used in a fuel pump impeller at cryogenic temperatures. Tension, fracture toughness, and fatigue crack propagation data were collected determining the effect of frequency and load ratio on crack propagation. The results revealed that tensile strength increased significantly at 20 K compared to room temperature and fracture toughness was reduced at cryogenic temperatures. The fatigue crack growth rate was not sensitive to experimental conditions and there were only minimal crack orientation effects. Different frequencies produced no effect. At various temperatures and frequencies a load ratio increase resulted in higher crack growth rates. At low stress intensity levels the fatigue rate for both temperatures was the same; however, at high stress intensity levels the crack growth rate at 20 K increased because of the decrease in fracture toughness. The results correlated well with previous data.

Ryder, J. T.↗

Electronic Components and Circuits for Extreme Temperature Environments

Planetary exploration missions and deep space probes require electrical power management and control systems that are capable of efficient and reliable operation in very low temperature environments. Presently, spacecraft operating in the cold environment of deep space carry a large number of radioisotope heating units in order to maintain the surrounding temperature of the on-board electronics at approximately 20 C. Electronics capable of operation at cryogenic temperatures will not only tolerate the hostile environment of deep space but also reduce system size and weight by eliminating or reducing the radioisotope heating units and their associate structures; thereby reducing system development as well as launch costs. In addition, power electronic circuits designed for operation at low temperatures are expected to result in more efficient systems than those at room temperature. This improvement results from better behavior and tolerance in the electrical and thermal properties of semiconductor and dielectric materials at low temperatures. The Low Temperature Electronics Program at the NASA Glenn Research Center focuses on research and development of electrical components, circuits, and systems suitable for applications in the aerospace environment and deep space exploration missions. Research is being conducted on devices and systems for reliable use down to cryogenic temperatures. Some of the commercial-off-the-shelf as well as developed components that are being characterized include switching devices, resistors, magnetics, and capacitors. Semiconductor devices and integrated circuits including digital-to-analog and analog-to-digital converters, DC/DC converters, operational amplifiers, and oscillators are also being investigated for potential use in low temperature applications. An overview of the NASA Glenn Research Center Low Temperature Electronic Program will be presented in this paper. A description of the low temperature test facilities along with selected data obtained through in-house component and circuit testing will also be discussed. Ongoing research activities that are being performed in collaboration with various organizations will also be presented.

Patterson, Richard L.↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

Laser-induced fluorescence of phosphors for remote cryogenic thermometry

Remote cryogenic temperature measurements can be made by inducing fluorescence in phosphors with temperature-dependent emissions and measuring the emission lifetimes. The thermographic phosphor technique can be used for making precision, noncontact, cryogenic-temperature measurements in electrically hostile environments, such as high dc electric or magnetic fields. The National Aeronautics and Space Administration is interested in using these thermographic phosphors for mapping hot spots on cryogenic tank walls. Europium-doped lanthanum oxysulfide (La2O2S:Eu) and magnesium fluorogermanate doped with manganese (Mg4FGeO6:Mn) are suitable for low-temperature surface thermometry. Several emission lines, excited by a 337-nm ultraviolet laser, provide fluorescence lifetimes having logarithmic dependence with temperature from 4 to above 125 K. A calibration curve for both La2O2S:Eu and Mg4FGeO6:Mn is presented, as well as emission spectra taken at room temperature and 11 K.

Beshears, D. L.↗

Cryogenic optical tests of a lightweight HIP beryllium mirror

Five interferometric tests were conducted at cryogenic temperatures on a lightweight, 50 cm diameter, hot isostatic pressed (HIP) beryllium mirror in the Ames Research Center (ARC) Cryogenic Optics Test Facility. The purpose of the tests was to determine the stability of the mirror's figure when cooled to cryogenic temperatures. Test temperatures ranged from room ambient to 8 K. One cycle to 8 K and five cycles to 80 K were performed. Optical and thermal test methods are described. Data is presented to show the amount of cryogenic distortion and hysteresis present in the mirror when measured with an earlier, Shack interferometer, and with a newly-acquired, phase-measuring interferometer.

Melugin, Ramsey K.↗

The cryogenic wind tunnel concept for high Reynolds number testing

Theoretical considerations indicate that cooling the wind-tunnel test gas to cryogenic temperatures will provide a large increase in Reynolds number with no increase in dynamic pressure while reducing the tunnel drive-power requirements. Studies were made to determine the expected variations of Reynolds number and other parameters over wide ranges of Mach number, pressure, and temperature, with due regard to avoiding liquefaction. Practical operational procedures were developed in a low-speed cryogenic tunnel. Aerodynamic experiments in the facility demonstrated the theoretically predicted variations in Reynolds number and drive power. The continuous-flow-fan-driven tunnel is shown to be particularly well suited to take full advantage of operating at cryogenic temperatures.

Kilgore, R. A.↗

Cryogenic Curation: Isolated Technology and Mission Operational Requirements for Sample Return

Future lunar, Mars, asteroid, and comet sample return missions may collect samples that have been preserved at sub-freezing or even cryogenic temperatures. For such samples, the study of volatiles and temperature-sensitive minerals will have high priority. Valuable geochemical and mineralogical information will be lost if such samples are allowed to reach ambient temperatures on Earth. The ability to store, document, subdivide, and transport extraterrestrial geologic samples while maintaining sub-freezing or cryogenic temperatures, possibly as low as 40 K, is required for the complete scientific study of samples from cold environments.

Calaway, Michael J.↗

Experimental Capabilities and Achievements of the Space Environment Dynamometer (SED)

The Space Environment Dynamometer (SED) chamber was designed to conduct research in cryobotics; an area of study that focuses on robotic systems and rotating machinery operating in extreme cold environments including Earth, low Earth orbit, Mars, Moon, asteroids, Solar orbit, planetary orbit, or those encountered during travel among these destinations. The test chamber incorporates a modular dynamometer, consisting of a variety of brakes, torque sensors and motors to be easily interchanged between tests. Each test employs a unique test profile that incorporates different setpoints of applied torques and velocities for a given period or number of rev- olutions. The modularity of the dynamometer setup allows for any combination of motor, gearbox to be tested. This chamber is one of a kind and resides at the Swamp Works facility within the Granular Mechanics and Regolith Operations laboratory (GMRO) at NASA Kennedy Space Center. Other cold chambers exist, however they are project specific and do not simultaneously output real time torque, temperature and efficiency data. The modularity of this extreme cold environment test chamber, coupled with the custom software and instrumentation, makes it one of a kind. The chamber is capable of stabilizing cryogenic temperatures and pressures to commensurate moon environments. Tests have successfully been conducted on motors and gearboxes for various cryogenic temperature set points, torques, and angular velocities. Relevant internal temperatures of the test article and chamber were recorded using a variety of temperature sensors. The temperature setpoints, on the motors and gearboxes tested, were stabilized by using PID gain scheduling of the PWM signal for the various heaters. The heat removal for the motor was provided by creating a thermally conductive path from a cryohead directly to the test article using copper straps. A variety of strainwave gears (SWGs), also known as Harmonic drives, planetary gear systems and DC motor actuator configurations have been tested in the chamber. The experiments performed were for various projects including Bulk Metallic Glass Gears (BMGG), Volatiles Investigating Polar Exploration Rover (VIPER), In-Situ Resource Utilization Pilot Excavator (IPEX) . Various upgrades have been made to the extreme cold environment test chamber for the use of cryobotic research. These upgrades greatly increased the autonomous capabilities of the test set up by providing redundancies in the hardware and software. The redundancies were primarily added to protect the integrity of the cryohead. A new strapping and insulation method was performed to create the thermal conductive path from the actuators to the cryohead. The software was upgraded to include temperature setpoint control, further increasing the autonomous capabilities of the test. This paper goes into detail regarding the upgrades made to the extreme cold environment test chamber, as well as highlights the results from a COLDArm acceptance test.

Casey J. Clark↗

Development of a Flexible Seal for a 60 psi Cryogenic Pressure Box

A cryogenic pressure box test facility has been designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 5 ft x 6 ft curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20 K) with 54 psig maximum pressure. The key challenge in the design and fabrication of the pressure box was the development of a seal that could remain flexible at -423 F and contain 60 psi gaseous helium as the pressurization gas. A C-shaped seal was developed using a Gore-tex woven fabric. Mechanical testing of the fabric at room and elevated temperature, liquid nitrogen temperature, and liquid helium temperature demonstrated the strength and creep resistance of the material over the desired operating range. A small scale cryogenic pressure box was used to test prototype seals at cryogenic temperatures up to 60 psi. Preliminary tests indicated that excessive leakage was present through the seal. As a result, an aluminized mylar liner was placed inside the Gore-tex seal to reduce leakage through the seal. The final seal configuration resulted in minimal pressure loss during seal testing.

Glass, David E.↗

Development of polyisocyanurate pour foam formulation for space shuttle external tank thermal protection system

Four commercially available polyisocyanurate polyurethane spray-foam insulation formulations are used to coat the external tank of the space shuttle. There are several problems associated with these formulations. For example, some do not perform well as pourable closeout/repair systems. Some do not perform well at cryogenic temperatures (poor adhesion to aluminum at liquid nitrogen temperatures). Their thermal stability at elevated temperatures is not adequate. A major defect in all the systems is the lack of detailed chemical information. The formulations are simply supplied to NASA and Martin Marietta, the primary contractor, as components; Part A (isocyanate) and Part B (poly(s) and additives). Because of the lack of chemical information the performance behavior data for the current system, NASA sought the development of a non-proprietary room temperature curable foam insulation. Requirements for the developed system were that it should exhibit equal or better thermal stability both at elevated and cryogenic temperatures with better adhesion to aluminum as compared to the current system. Several formulations were developed that met these requirements, i.e., thermal stability, good pourability, and good bonding to aluminum.

Harvey, James A.↗

Temperature-dependent Refractive Index of Silicon and Germanium

Silicon and germanium are perhaps the two most well-understood semiconductor materials in the context of solid state device technologies and more recently micromachining and nanotechnology. Meanwhile, these two materials are also important in the field of infrared lens design. Optical instruments designed for the wavelength range where these two materials are transmissive achieve best performance when cooled to cryogenic temperatures to enhance signal from the scene over instrument background radiation. In order to enable high quality lens designs using silicon and germanium at cryogenic temperatures, we have measured the absolute refractive index of multiple prisms of these two materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For silicon, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 20 to 300 K at wavelengths from 1.1 to 5.6 pin, while for germanium, we cover temperatures ranging from 20 to 300 K and wavelengths from 1.9 to 5.5 microns. We compare our measurements with others in the literature and provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures. Citing the wide variety of values for the refractive indices of these two materials found in the literature, we reiterate the importance of measuring the refractive index of a sample from the same batch of raw material from which final optical components are cut when absolute accuracy greater than k5 x 10" is desired.

Frey, Bradley J.↗