A Dual 5T Superconducting Magnet System for the Brookhaven National Lab Electron Beam Ion Source

Cryomagnetics has delivered an upgraded magnet system to the Brookhaven National Laboratory's RHIC Electron Beam Ion Source project. This consists of two 2.25-m long, 215-mm room temperature bore 5T solenoids separated by 20 cm. The initial system used a single PT-415RM cryocooler but was unstable a long term. As a result, the new system adds a second SHI cryocooler, which produces much higher recondensing margins.

43 PARTICLE ACCELERATORS↗

MO-F-CAMPUS-J-04: Radiation Heat Load On the MR System of the Elekta Atlantic System

Purpose: The Elekta Atlantic system combines a digital linear accelerator system with a 1.5T Philips MRI machine.This study aimed to assess the energy deposited within the cryostat system when the radiation beam passes through the cryostat. The cryocooler on the magnet has a cooling capacity which is about 1 Watt in excess of the cryogenic heat leak into the magnet’s cold mass. A pressure-controlled heater inside the magnet balances the excess refrigeration power such that the helium pressure in the tank is kept slightly above ambient air pressure. If radiation power is deposited in the cold mass then this heater will need less power to maintain pressure equilibrium and if the radiation heat load exceeds the excess cryocooler capacity the pressure will rise. Methods: An in-house CAD based Monte Carlo code based on Penelope was used to model the entire MR-Linac system to quantify the heat load on the magnet’s cold mass. These results were then compared to experimental results obtained from an Elekta Atlantic system installed in UMC-Utrecht. Results: For a field size of 25 cm x 22 cm and a dose rate of 107 mu.min-1, the energy deposited by the radiation beam led to a reduction in heater power from 1.16 to 0.73 W. Simulations predicted a reduction to 0.69 W which is in good agreement. For the worst case field size (largest) and maximum dose rate the cryostat cooler capacity was exceeded. This resulted in a pressure rise within the system but was such that continuous irradiation for over 12 hours would be required before the magnet would start blowing off helium. Conclusion: The study concluded that the Atlantic system does not have to be duty cycle restricted, even for the worst case non-clinical scenario and that there are no adverse effects on the MR system. Stephen Towe and David Roberts Both work for Elekta; Ezra Van Lanen works for Philips Healthcare; Johan Overweg works for Philips Innovative Technologies.

60 APPLIED LIFE SCIENCES↗

Development of the first 1 GHz niobium-tin quarter-wave cavity

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

Zhou, Yang [Argonne]↗

Higher order mode analysis of a 915 MHz 2-cell cavity for a prototype industrial accelerator

A possible solution to reduce the complexity posed by the cryogenic systems in a superconducting RF accelerator for industrial applications, is to capitalize on the advances achieved by the Nb3Sn superconducting RF technology, as well as the feasibility of a reliable 4 K cooling system, based on commercial cryocoolers. Following this philosophy, the conceptual design for a prototype, conduction-cooled, 4 MeV, 20 kW SRF electron linac, is being developed at Jefferson Lab. Such design is based on a 915 MHz two-cell Nb3Sn cavity. In this contribution, we present the proposed cavity design, including the fundamental power coupler, and the analysis of the Higher Order Modes, using numerical simulations to estimate the potentially dangerous modes and to provide the requirements for damping for reliable operations with a cryocooler.

Rimmer, Robert↗

Conduction-Cooled Operation of an SRF Multi-Cell Cavity

The development of compact, SRF-based accelerators for applications beyond research is experiencing notable advancements due to the use of cryocoolers for conduction-cooling instead of traditional liquid cryogens. Following the successful demonstration of a single-cell cavity operated through conduction cooling with three two-stage cryocoolers, Jefferson Lab (JLab) has made strides in the operation of a multi-cell resonator. This milestone paves the way for high-energy applications of compact, conduction-cooled SRF machines. The demonstration, carried out in collaboration with General Atomics, will take place in a dedicated horizontal test cryostat (HTC) at their San Diego facility. This presentation will highlight the technological developments, the latest results, and valuable lessons learned.

Vennekate, J. [Thomas Jefferson National Accelerat↗

Preliminary Investigation in removing microphonic noise from nuclear detectors

Developing tools to perform nuclear spectroscopy using unattended sensor nodes would greatly enhance LANL’s ability to address nuclear material identification and detection challenges in the non‐proliferation and treaty verification domains. High purity germanium crystals are the gold standard detector used for performing high‐resolution nuclear spectroscopy. In order to function properly, these crystals must be brought down to liquid nitrogen temperatures. In practice the required temperature is typically achieved using liquid nitrogen dewars. The shortcoming with this strategy is that the dewars must be refilled roughly every week. This requirement is not practical for applications that require collecting nuclear spectroscopy data in remote/inaccessible areas. An alternative is to use a piston‐driven cryocooler to achieve liquid nitrogen temperatures. Piston‐driven cryocoolers, can operate unattended, but the microphonic noise induced by the vibrations produced by these coolers causes the resolution of the spectroscopic measurements to severely degrade, making identification of nuclear materials significantly more difficult. The goal of this research effort was to reduce the effects of microphonic noise.

42 ENGINEERING↗

Simulation of Conduction Cooled SRF Cavity

SRF cavities are used heavily in high energy physics research, but the operational complexities of SRF cavities prevent their widespread use in industry. One notable complexity of operating an SRF cavity is liquid helium coolant, and replacing liquid helium with cryocooler conduction cooling is an important research and development interest. As part of this effort, a system consisting of a 650 MHz single cell cavity, a commercial grade pulse tube refrigerator, and a thermal conduction link was simulated through finite element analysis. The electromagnetic fields inside the cavity, heat flow through the system, and temperature distribution of the thermal link and cavity were calculated. Based on the simulation, we found that a 2 W @ 4.2 K pulse tube refrigerator is capable of cooling a single cell Nb 3 Sn coated cavity operating at up to 12 MV/m accelerating gradient. The maximum simulated temperature of the cavity was below 7 K, and the thermal conduction link was shown to significantly attenuate the cryocooler thermal oscillations at the location of the cavity

43 PARTICLE ACCELERATORS↗

A Conduction-Cooled SRF Cavity: Apparatus and First Results [PowerPoint]

First ever demonstration of accelerating gradients on a cryogen-free, cryocooler conduction-cooled SRF cavity • Niobium cavity produced >1.5 MV/m with a 2 W @ 4.2 K cryocooler • There is considerable scope for improving the thermal management in our setup • Ongoing: mitigation of static heat leak • An Nb 3 Sn coated cavity is projected to yield >10 MV/m accelerating gradients on our existing setup • Tests are planned for the near future.

43 PARTICLE ACCELERATORS↗

CryoTARPOS Vibration Mitigation System for Layered Experiments

The goal of this project is to implement a system that can eliminate or mitigate vibration so that clear images can be taken without bypassing the cryocooler. By allowing for layer characterization and cryocooler operation at the same time, cooling capacity and thermal stability of the target would be improved, and more layer characterization data could be taken. Increased cooling capacity and thermal stability could allow for layering during occasional off normal conditions that would typically result in a loss of temperature control and NIF operational delays ranging from several hours to several days per month. The increased cooling capacity and thermal stability could also allow for layering of new target platforms that have less cooling margin. Additional layer images could be used for better characterization of defects and non-uniformities in the layer and would reduce the likelihood of layer seed loss, which typically adds ~12 hours per week in layering time. Motion blur from vibration due to off normal activity in the NIF Target Bay could also be mitigated that would usually result in NIF operational delays of several hours every month.

42 ENGINEERING↗

Design and demonstration of an economical SRF structure for Continuous Wave (CW), high-energy, Megawatt-class beams

Due to its very high RF-to-beam efficiency, superconducting radiofrequency (SRF) cavities have become the technology of choice for the construction of large linear accelerators (linacs) for basic science applications (examples, ESS and PIP-II). The technology is also attractive for high volume industrial applications such as electron irradiation processing of wastewater and flue gas. However, SRF’s current reliance on liquid helium for cryogenic cooling introduces infrastructural and safety challenges for use in industrial settings. Cryocooler conduction-cooling is a recently developed novel technique for operating SRF cavities without requiring liquid helium. This project aims for technical design and economic assessment of a medium energy, high average power e-beam linac based on the conduction-cooled SRF technique for high volume irradiation treatment of wastewater. The goals of this project are (1) to design a medium energy (10 MeV), high average power (1 MW) electron beam accelerator around the cryocooler conduction-cooled SRF cavity technology, (2) demonstrate the required accelerating voltage on a prototype cavity, and (3) build a cost-model to evaluate capital and operating expense of the accelerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cryogenic Plant Integration for the Colossus milli-Kelvin Platform at Fermilab

The Colossus platform at Fermilab will be the largest and most powerful 3He/4He dilution-cooled cryogenic system constructed to-date. Perhaps its primary innovation will be in the integration of a liquid helium cryogenics plant to cool the stages typically cooled by mechanical cryocoolers in commercially available cryogen-free dilution refrigerators. This design shift carries with it important implications for the future of cryogenics associated with quantum computing due to the inherently greater efficiencies of helium cryogenic plants when compared to the use of multitude of independent mechanical cryocoolers. Construction of Colossus is expected to begin in 2023 with a target of commencing operations in 2025.

Tatkowski, G.↗

Comparison of copper and aluminum as the thermal link material for conduction-cooled accelerator cavities

Cryocooler conduction-cooling has recently emerged as a new frontier for cryogenic cooling for superconducting radiofrequency (SRF) cavities. In this scheme, an SRF cavity is mechanically coupled to a closed-cycle cryocooler using linkages made of high thermal conductivity metals. In this note, we compare the thermal transport properties of high purity aluminum and high purity copper as applied to SRF cavity conduction cooling. We show that copper can enable faster cooldown than aluminum from room temperature to the base temperature near 4 K and behave equally well or better during steady state cavity operation near the base temperature.

36 MATERIALS SCIENCE↗

Regeneration efficiency, shuttle heat loss and thermal conductivity in epoxy-composite annualr gap regenerators from 4K to 80K

A test apparatus designed to simulate a section of a Stirling cycle cryocooler was built. Measurements of regeneration efficiency, shuttle heat loss and thermal conductivity reported for several regenerator test sections. The test composites were epoxy glass, epoxy glass with lead particles, epoxy glass with activated charcoal and epoxy graphite. Losses measured for these materials were approximately the same. Losses are in good agreement with those calculated theoretically for an epoxy glass (C-10) composite. The implications of these results on cryocooler design are discussed.

Myrtle, K.↗

An experimental study for a miniature Stirling refrigerator

Experimental results of a miniature two-stage Stirling cryocooler are introduced. The influence of filling gas pressure and refrigeration temperature on the refrigerating capacity along with the relationship between parameters was measured. The valley pressure corresponding to the lowest refrigeration temperature and the cooldown time versus operating pressure are discussed. The coefficient of performance and thermodynamic efficiency of the cryocooler are calculated based on experimental data.

Li, S.↗

Space Cryogenics Workshop, 10th, Cleveland, OH, June 18-20, 1991, Proceedings

The present workshop on cryogenics discusses the anomalous on-orbit behavior of the Cosmic Background Explorer Dewar, the SHOOT orbital operations, cooling options for Astromag, and space IR telescope facility mission and cryogenic design. Attention is given to the design of a spaceworthy adiabatic demagnetization refrigerator, the evaluation of metal hydride compressors for applications in Joule-Thomson cryocoolers, diaphragm Stirling cryocooler developments, and a computer simulation model for Stirling refrigerators. Topics addressed include low-gravity thermal stratification of liquid helium on SHOOT, a screening program to select a resin for gravity probe-B composites, a simplified generic cryostat thermal model for predicting cryogen mass and lifetime, and the effect of gas mass flux on cryogenic liquid jet breakup. Also discussed are damping criteria for thermal acoustic oscillations in slush and liquid hydrogen systems, an STS-based cryogenic fluid management experiment, and the design and testing of a cryogenic mixer pump.

Source record↗

Active Suppression Of Vibrations In Stirling-Cycle Coolers

Report presents results of early research directed toward development of active control systems for suppression of vibrations in spacecraft Stirling-cycle cryocoolers. Researchers developed dynamical models of cryocooler compressor.

Johnson, Bruce G.↗

Sorption cooling of astrophysics science instruments

The current status of continuous and periodic operation sorption cryocooler development for astrophysics missions requiring refrigeration to 4 K and below, is reviewed. These coolers are suited for the cooling of detectors in planned astrophysics missions such as the exploration of neighboring planetary systems planet finder array (ExNPS PFA). The cooler requirements imposed by these missions include a ten-year life, zero vibration, zero electromagnetic interference and electromagnetic charging operation, and the ability to scale designs to provide low refrigeration capability with low power consumption. Spaceflight test results are summarized for the brilliant eyes 10 K sorption cryocooler experiment. This experiment successfully validated flight cooler performance and provided characterization of all sorption cooler design parameters which may have shown sensitivity to microgravity effects. Ground test results from a continuous 25 K cooler planned for use in a long duration airborne balloon experiment are presented. A NASA program to develop 30 K, 10 K and 4 K vibration-free coolers for astrophysics missions is outlined.

Wade, Lawrence A.↗

Flight Test Results for the HST Orbital Systems Test (HOST) Capillary Pump Loop Cooling System

The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope (MST) in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will significantly shorten the instrument's useful life. A reverse Brayton cycle mechanical refrigerator will be installed during the Third Servicing Mission (SM3) to provide cooling for the instrument, and thereby extend its operations. A Capillary Pump Loop (CPL) and radiator system was designed, built and tested to remove up to 500 watts of heat from the mechanical cryocooler and its associated electronics. The HST Orbital Systems Test (HOST) platform was flown on the Space Shuttle Discovery (STS-95) as a flight demonstration of the cryocooler system, CPL control electronics, and the CPL/Radiator. This paper will present the flight test results and thermal performance of the CPL system in detail.

Buchko, M.↗