Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Iterative universal state selective correction for the Brillouin-Wigner multireference coupled-cluster theory

As a further development of the previously introduced a posteriori Universal State-Selective (USS) corrections [K. Kowalski, J. Chem. Phys. 134, 194107 (2011)] and [Brabec et al., J. Chem. Phys., 136, 124102 (2012)], we suggest an iterative form of the USS correction by means of correcting effective Hamiltonian matrix elements. We also formulate USS corrections via the left Bloch equations. The convergence of the USS corrections with excitation level towards the FCI limit is also investigated. Various forms of the USS and simplified diagonal USSD corrections at the SD and SD(T) levels are numerically assessed on several model systems and on the ozone and tetramethyleneethane molecules. It is shown that the iterative USS correction can successfully replace the previously developed a posteriori BWCC size-extensivity correction, while it is not sensitive to intruder states and performs well also in other cases when the a posteriori one fails, like e.g. for the asymmetric vibration mode of ozone.

Brillouin-Wigner↗

A prescription for the asteroseismic surface correction

In asteroseismology, the surface effect refers to a disparity between the observed and the modelled frequencies in stars with solar-like oscillations. It originates from improper modelling of the surface layers. Correcting the surface effect usually requires using functions with free parameters, which are conventionally fitted to the observed frequencies. On the basis that the correction should vary smoothly across the H–R diagram, we parameterize it as a simple function of surface gravity, effective temperature, and metallicity. We determine this function by fitting a wide range of stars. The absolute amount of the surface correction decreases with luminosity, but the ratio between it and νmax increases, suggesting the surface effect is more important for red giants than dwarfs. Applying the prescription can eliminate unrealistic surface correction, which improves parameter estimations with stellar modelling. Using two open clusters, we found a reduction of scatter in the model-derived ages for each star in the same cluster. As an important application, we provide a new revision for the Δν scaling relation that, for the first time, accounts for the surface correction. The values of the correction factor, f Δν , are up to 2 percent smaller than those determined without the surface effect considered, suggesting decreases of up to 4 percent in radii and up to 8 percent in masses when using the asteroseismic scaling relations. This revision brings the asteroseismic properties into an agreement with those determined from eclipsing binaries. The new correction factor and the stellar models with the corrected frequencies are available at https://www.github.com/parallelpro/surface.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of weak corrections to Drell-Yan, top-quark pair, and dijet production at high energies with MCFM

Electroweak (EW) corrections can be enhanced at high energies due to the soft or collinear radiation of virtual and real W and Z bosons that result in Sudakov-like corrections of the form α$l\atop{W}$log n (Q 2 /M2$\atop{W,Z}$), where α W =α/(4π sin 2 θ W ) and n ≤ 2l-1. The inclusion of EW corrections in predictions for hadron colliders is, therefore, especially important when searching for signals of possible new physics in distributions probing the kinematic regime Q 2 >>M$2\atop{V}$. Next-to-leading order (NLO) EW corrections should also be taken into account when their size [O(α)] is comparable to that of QCD corrections at next-to-next-to-leading order (NNLO) [O(α$2\atop{s}$)]. To this end, we have implemented the NLO weak corrections to the neutral-current Drell-Yan process, top-quark pair production and dijet production in the parton-level Monte Carlo program MCFM. This enables a combined study with the corresponding QCD corrections at NLO and NNLO. We provide both the full NLO weak corrections and their Sudakov approximation since the latter is often used for a fast evaluation of weak effects at high energies and can be extended to higher orders. Finally, with both the exact and approximate results at hand, the validity of the Sudakov approximation can be readily quantified.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the wall perturbation correction for a parallel-plate NACP-02 chamber in clinical electron beams

Purpose: In recent years, several Monte Carlo studies have been published concerning the perturbation corrections of a parallel-plate chamber in clinical electron beams. In these studies, a strong depth dependence of the relevant correction factors (p{sub wall} and p{sub cav}) for depth beyond the reference depth is recognized and it has been shown that the variation with depth is sensitive to the choice of the chamber's effective point of measurement. Recommendations concerning the positioning of parallel-plate ionization chambers in clinical electron beams are not the same for all current dosimetry protocols. The IAEA TRS-398 as well as the IPEM protocol and the German protocol DIN 6800-2 interpret the depth of measurement within the phantom as the water equivalent depth, i.e., the nonwater equivalence of the entrance window has to be accounted for by shifting the chamber by an amount {Delta}z. This positioning should ensure that the primary electrons traveling from the surface of the water phantom through the entrance window to the chamber's reference point sustain the same energy loss as the primary electrons in the undisturbed phantom. The objective of the present study is the determination of the shift {Delta}z for a NACP-02 chamber and the calculation of the resulting wall perturbation correction as a function of depth. Moreover, the contributions of the different chamber walls to the wall perturbation correction are identified. Methods: The dose and fluence within the NACP-02 chamber and a wall-less air cavity is calculated using the Monte Carlo code EGSnrc in a water phantom at different depths for different clinical electron beams. In order to determine the necessary shift to account for the nonwater equivalence of the entrance window, the chamber is shifted in steps {Delta}z around the depth of measurement. The optimal shift {Delta}z is determined from a comparison of the spectral fluence within the chamber and the bare cavity. The wall perturbation correction is calculated as the ratio between doses for the complete chamber and a wall-less air cavity. Results: The high energy part of the fluence spectra within the chamber strongly varies even with small chamber shifts, allowing the determination of {Delta}z within micrometers. For the NACP-02 chamber a shift {Delta}z=-0.058 cm results. This value is independent of the energy of the primary electrons as well as of the depth within the phantom and it is in good agreement with the value recommended in the German dosimetry protocol. Applying this shift, the calculated wall perturbation correction as a function of depth is varying less than 1% from zero up to the half value depth R{sub 50} for electron energies in the range of 6-21 MeV. The remaining depth dependence can mainly be attributed to the scatter properties of the entrance window. When neglecting the nonwater equivalence of the entrance window, the variation of p{sub wall} with depth is up to 10% and more, especially for low electron energies. Conclusions: The variation of the wall perturbation correction for the NACP-02 chamber in clinical electron beams strongly depends on the positioning of the chamber. Applying a shift {Delta}z=-0.058 cm toward the focus ensures that the primary electron spectrum within the chamber bears the largest resemblance to the fluence of a wall-less cavity. Hence, the influence of the chamber walls on the perturbation correction can be separated out and the residual variation of p{sub wall} with depth is minimized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRE-01: A Rapid Method to Determine An Upper Limit On a Radiation Detector's Correction Factor During the QA of IMRT Plans

Purpose: Discrepancies in the verification of the absorbed dose to water from an IMRT plan using a radiation dosimeter can be wither caused by 1) detector specific nonstandard field correction factors as described by the formalism of Alfonso et al. 2) inaccurate delivery of the DQA plan. The aim of this work is to develop a simple/fast method to determine an upper limit on the contribution of composite field correction factors to these discrepancies. Methods: Indices that characterize the non-flatness of the symmetrised collapsed delivery (VSC) of IMRT fields over detector-specific regions of interest were shown to be correlated with IMRT field correction factors. The indices introduced are the uniformity index (UI) and the mean fluctuation index (MF). Each one of these correlation plots have 10 000 fields generated with a stochastic model. A total of eight radiation detectors were investigated in the radial orientation. An upper bound on the correction factors was evaluated by fitting values of high correction factors for a given index value. Results: These fitted curves can be used to compare the performance of radiation dosimeters in composite IMRT fields. Highly water-equivalent dosimeters like the scintillating detector (Exradin W1) and a generic alanine detector have been found to have corrections under 1% over a broad range of field modulations (0 – 0.12 for MF and 0 – 0.5 for UI). Other detectors have been shown to have corrections of a few percent over this range. Finally, a full Monte Carlo simulations of 18 clinical and nonclinical IMRT field showed good agreement with the fitted curve for the A12 ionization chamber. Conclusion: This work proposes a rapid method to evaluate an upper bound on the contribution of correction factors to discrepancies found in the verification of DQA plans.

07 ISOTOPE AND RADIATION SOURCES↗

Reduction of ring artifacts in CBCT: Detection and correction of pixel gain variations in flat panel detectors

Purpose: In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accounted by conventional flat field correction methods. In this work, the authors presented a method to identify isolated pixel clusters that exhibit gain variations and proposed a pixel gain correction (PGC) method to suppress both beam hardening and exposure level dependent gain variations. Methods: To modulate both beam spectrum and entrance exposure, flood field FPD projections were acquired using beam filters with varying thicknesses. “Ideal” pixel values were estimated by performing polynomial fits in both raw and flat field corrected projections. Residuals were calculated by taking the difference between measured and ideal pixel values to identify clustered image and FPD artifacts in flat field corrected and raw images, respectively. To correct clustered image artifacts, the ratio of ideal to measured pixel values in filtered images were utilized as pixel-specific gain correction factors, referred as PGC method, and they were tabulated as a function of pixel value in a look-up table. Results: 0.035% of detector pixels lead to clustered image artifacts in flat field corrected projections, where 80% of these pixels were traced back and linked to artifacts in the FPD. The performance of PGC method was tested in variety of imaging conditions and phantoms. The PGC method reduced clustered image artifacts and fixed pattern noise in projections, and ring artifacts in CBCT images. Conclusions: Clustered projection image artifacts that lead to ring artifacts in CBCT can be better identified with our artifact detection approach. When compared to the conventional flat field correction method, the proposed PGC method enables characterization of nonlinear pixel gain variations as a function of change in x-ray spectrum and intensity. Hence, it can better suppress image artifacts due to beam hardening as well as artifacts that arise from detector entrance exposure variation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields

Purpose: A close proximity hybrid x-ray/magnetic resonance (XMR) imaging system offers several critical advantages over current XMR system installations that have large separation distances (∼5 m) between the imaging fields of view. The two imaging systems can be placed in close proximity to each other if an x-ray tube can be designed to be immune to the magnetic fringe fields outside of the MR bore. One of the major obstacles to robust x-ray tube design is correcting for the effects of the MR fringe field on the x-ray tube focal spot. Any fringe field component orthogonal to the x-ray tube electric field leads to electron drift altering the path of the electron trajectories. Methods: The method proposed in this study to correct for the electron drift utilizes an external electric field in the direction of the drift. The electric field is created using two electrodes that are positioned adjacent to the cathode. These electrodes are biased with positive and negative potential differences relative to the cathode. The design of the focusing cup assembly is constrained primarily by the strength of the MR fringe field and high voltage standoff distances between the anode, cathode, and the bias electrodes. From these constraints, a focusing cup design suitable for the close proximity XMR system geometry is derived, and a finite element model of this focusing cup geometry is simulated to demonstrate efficacy. A Monte Carlo simulation is performed to determine any effects of the modified focusing cup design on the output x-ray energy spectrum. Results: An orthogonal fringe field magnitude of 65 mT can be compensated for using bias voltages of +15 and −20 kV. These bias voltages are not sufficient to completely correct for larger orthogonal field magnitudes. Using active shielding coils in combination with the bias electrodes provides complete correction at an orthogonal field magnitude of 88.1 mT. Introducing small fields (<10 mT) parallel to the x-ray tube electric field in addition to the orthogonal field does not affect the electrostatic correction technique. However, rotation of the x-ray tube by 30° toward the MR bore increases the parallel magnetic field magnitude (∼72 mT). The presence of this larger parallel field along with the orthogonal field leads to incomplete correction. Monte Carlo simulations demonstrate that the mean energy of the x-ray spectrum is not noticeably affected by the electrostatic correction, but the output flux is reduced by 7.5%. Conclusions: The maximum orthogonal magnetic field magnitude that can be compensated for using the proposed design is 65 mT. Larger orthogonal field magnitudes cannot be completely compensated for because a pure electrostatic approach is limited by the dielectric strength of the vacuum inside the x-ray tube insert. The electrostatic approach also suffers from limitations when there are strong magnetic fields in both the orthogonal and parallel directions because the electrons prefer to stay aligned with the parallel magnetic field. These challenging field conditions can be addressed by using a hybrid correction approach that utilizes both active shielding coils and biasing electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗

RFQAmodel: Random Forest Quality Assessment to identify a predicted protein structure in the correct fold

While template-free protein structure prediction protocols now produce good quality models for many targets, modelling failure remains common. For these methods to be useful it is important that users can both choose the best model from the hundreds to thousands of models that are commonly generated for a target, and determine whether this model is likely to be correct. We have developed Random Forest Quality Assessment (RFQAmodel), which assesses whether models produced by a protein structure prediction pipeline have the correct fold. RFQAmodel uses a combination of existing quality assessment scores with two predicted contact map alignment scores. These alignment scores are able to identify correct models for targets that are not otherwise captured. Our classifier was trained on a large set of protein domains that are structurally diverse and evenly balanced in terms of protein features known to have an effect on modelling success, and then tested on a second set of 244 protein domains with a similar spread of properties. When models for each target in this second set were ranked according to the RFQAmodel score, the highest-ranking model had a high-confidence RFQAmodel score for 67 modelling targets, of which 52 had the correct fold. At the other end of the scale RFQAmodel correctly predicted that for 59 targets the highest-ranked model was incorrect. In comparisons to other methods we found that RFQAmodel is better able to identify correct models for targets where only a few of the models are correct. We found that RFQAmodel achieved a similar performance on the model sets for CASP12 and CASP13 free-modelling targets. Finally, by iteratively generating models and running RFQAmodel until a model is produced that is predicted to be correct with high confidence, we demonstrate how such a protocol can be used to focus computational efforts on difficult modelling targets. RFQAmodel and the accompanying data can be downloaded from http://opig.stats.ox.ac.uk/resources.

59 BASIC BIOLOGICAL SCIENCES↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 114: Area 25 EMAD Facility Nevada National Security Site, Nevada, (Rev.0, with ROTC 1)

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 114, Area 25 EMAD Facility, identified in the Federal Facility Agreement and Consent Order (FFACO). CAU 114 comprises the following corrective action sites (CASs) located in Area 25 of the Nevada National Security Site (formerly, the Nevada Test Site): 25-41-03, EMAD Facility; 25-99-23, Manned Control Car (MCC) and Engine Installation Vehicle (EIV); and 25-33-05, Building 3901, Engine Transport System Maintenance Building. This plan provides the methodology for field activities needed to gather the necessary information for closing CAU 114. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 114 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective actions for CAU 114. It is anticipated that the results of the field investigation and implementation of corrective actions will support a defensible recommendation that no further corrective action is necessary. The purpose of the corrective action investigation will be to document and verify the adequacy of existing information; to affirm the decision for either clean closure, closure in place, or no further action; and to provide sufficient data to implement the corrective action. The actual corrective action selected will be based on characterization activities implemented under this SAFER Plan. If specific conditions or findings fall outside the bounds of the SAFER Plan, the Nevada Division of Environmental Protection (NDEP) will be consulted to determine the path forward before proceeding. Upon completion of SAFER activities, a closure report will be prepared and submitted to NDEP for review and approval. The schedule for completion of the closure report will be established at the FFACO annual meeting.

54 ENVIRONMENTAL SCIENCES↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 544: Cellars, Mud Pits, and Oil Spills, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 544, Cellars, Mud Pits, and Oil Spills, identified in the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit 544 comprises the following 20 corrective action sites (CASs) located in Areas 2, 7, 9, 10, 12, 19, and 20 of the Nevada Test Site (NTS): • 02-37-08, Cellar & Mud Pit • 02-37-09, Cellar & Mud Pit • 07-09-01, Mud Pit • 09-09-46, U-9itsx20 PS #1A Mud Pit • 10-09-01, Mud Pit • 12-09-03, Mud Pit • 19-09-01, Mud Pits (2) • 19-09-03, Mud Pit • 19-09-04, Mud Pit • 19-25-01, Oil Spill • 19-99-06, Waste Spill • 20-09-01, Mud Pits (2) • 20-09-02, Mud Pit • 20-09-03, Mud Pit • 20-09-04, Mud Pits (2) • 20-09-06, Mud Pit • 20-09-07, Mud Pit • 20-09-10, Mud Pit • 20-25-04, Oil Spills • 20-25-05, Oil Spills This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 544 using the SAFER process. Using the approach approved for previous mud pit investigations (CAUs 530–535), 14 mud pits have been identified that • are either a single mud pit or a system of mud pits, • are not located in a radiologically posted area, and • have no evident biasing factors based on visual inspections. These 14 mud pits are recommended for no further action (NFA), and further field investigations will not be conducted. For the sites that do not meet the previously approved closure criteria, additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible recommendation for closure of the remaining CASs in CAU 544. This will be presented in a closure report (CR) that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval. The sites will be investigated based on the data quality objectives (DQOs) developed on April 27, 2010, by representatives of NDEP and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO). The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each CAS in CAU 544. The DQO process developed for this CAU identified the following expected closure options: (1) investigation and confirmation that no contamination exists above the final action levels (FALs) leading to an NFA declaration, (2) characterization of the nature and extent of contamination leading to closure in place with use restrictions, (3) clean closure by remediation and verification, (4) closure in place with use restrictions with no investigation if CASs are in crater areas that have been determined to be unsafe to enter, or (5) NFA if the mud pit CAS meets the criteria established during the CAUs 530–535 SAFER investigation. The following summarizes the SAFER activities that will support the closure of CAU 544: • Perform visual inspection of all CASs. • Perform site preparation activities (e.g., utilities clearances, construction of temporary site exclusion zones). • Removal of easily managed, nonhazardous, and nonradioactive debris, including vegetation (e.g., tumbleweeds), at various CASs that interfere with sampling, if required to inspect soil surface or collect soil sample. • Collect environmental samples from designated target populations (e.g., mud pits, cellars, stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • If no COCs are present at a CAS, establish NFA as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC is present at a CAS, either - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Confirm the preferred closure option is sufficient to protect human health and the environment.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of two Vaisala RS92 radiosonde solar radiative dry bias correction algorithms

Solar heating of the relative humidity (RH) probe on Vaisala RS92 radiosondes results in a large dry bias in the upper troposphere. Two different algorithms (Miloshevich et al., 2009, MILO hereafter; and Wang et al., 2013, WANG hereafter) have been designed to account for this solar radiative dry bias (SRDB). These corrections are markedly different with MILO adding up to 40 % more moisture to the original radiosonde profile than WANG; however, the impact of the two algorithms varies with height. The accuracy of these two algorithms is evaluated using three different approaches: a comparison of precipitable water vapor (PWV), downwelling radiative closure with a surface-based microwave radiometer at a high-altitude site (5.3 km m.s.l.), and upwelling radiative closure with the space-based Atmospheric Infrared Sounder (AIRS). The PWV computed from the uncorrected and corrected RH data is compared against PWV retrieved from ground-based microwave radiometers at tropical, midlatitude, and arctic sites. Although MILO generally adds more moisture to the original radiosonde profile in the upper troposphere compared to WANG, both corrections yield similar changes to the PWV, and the corrected data agree well with the ground-based retrievals. The two closure activities – done for clear-sky scenes – use the radiative transfer models MonoRTM and LBLRTM to compute radiance from the radiosonde profiles to compare against spectral observations. Both WANG- and MILO-corrected RHs are statistically better than original RH in all cases except for the driest 30 % of cases in the downwelling experiment, where both algorithms add too much water vapor to the original profile. In the upwelling experiment, the RH correction applied by the WANG vs. MILO algorithm is statistically different above 10 km for the driest 30 % of cases and above 8 km for the moistest 30 % of cases, suggesting that the MILO correction performs better than the WANG in clear-sky scenes. Lastly, the cause of this statistical significance is likely explained by the fact the WANG correction also accounts for cloud cover – a condition not accounted for in the radiance closure experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ellipsoidal corrections for geoid undulation computations using gravity anomalies in a cap

Ellipsoidal correction terms have been derived for geoid undulation computations when the Stokes equation using gravity anomalies in a cap is combined with potential coefficient information. The correction terms are long wavelength and depend on the cap size in which its gravity anomalies are given. Using the regular Stokes equation, the maximum correction for a cap size of 20 deg is -33 cm, which reduces to -27 cm when the Stokes function is modified by subtracting the value of the Stokes function at the cap radius. Ellipsoidal correction terms were also derived for the well-known Marsh/Chang geoids. When no gravity was used, the correction could reach 101 cm, while for a cap size of 20 deg the maximum correction was -45 cm. Global correction maps are given for a number of different cases. For work requiring accurate geoid computations these correction terms should be applied.

Rapp, R. H.↗

Wind tunnel wall interference correction for aircraft models

Wall interference correction procedures seek to determine the required changes in certain flow or geometric parameters so that the difference between the flow properties at the model's surface in the tunnel and free air are minimized. A transonic and a linear correction procedure were developed for aircraft models. In addition to Mach number and angle of attack corrections, an estimate of the accuracy of the corrections is provided by the transonic correction procedure. Lift, pitching moment and pressure measurements near the tunnel walls are required. The efficiency and accuracy of the correction procedure are improved. Moreover, correction of both the wing and tail angles of attack is allowed. The procedure is valid for transonic as well as subcritical flows. However, for subcritical flows further approximations and simplifying assumptions are made, leading to a very simple and efficient correction procedure.

Rizk, M. H.↗

Determination of corrections to flow direction measurements obtained with a wing-tip mounted sensor

The nature of corrections for flow direction measurements obtained with a wing-tip mounted sensor was investigated. Corrections for the angle of attack and sideslip, measured by sensors mounted in front of each wing tip of a general aviation airplane, were determined. These flow corrections were obtained from both wind-tunnel and flight tests over a large angle-of-attack range. Both the angle-of-attack and angle-of-sideslip flow corrections were found to be substantial. The corrections were a function of the angle of attack and angle of sideslip. The effects of wing configuration changes, small changes in Reynolds number, and spinning rotation on the angle-of-attack flow correction were found to be small. The angle-of-attack flow correction determined from the static wind-tunnel tests agreed reasonably well with the correction determined from flight tests.

Moul, T. M.↗

Correlated environmental corrections in TOPEX/POSEIDON, with a note on ionospheric accuracy

Estimates of the effectiveness of an altimetric correction, and interpretation of sea level variability as a response to atmospheric forcing, both depend upon assuming that residual errors in altimetric corrections are uncorrelated among themselves and with residual sea level, or knowing the correlations. Not surprisingly, many corrections are highly correlated since they involve atmospheric properties and the ocean surface's response to them. The full corrections (including their geographically varying time mean values), show correlations between electromagnetic bias (mostly the height of wind waves) and either atmospheric pressure or water vapor of -40%, and between atmospheric pressure and water vapor of 28%. In the more commonly used collinear differences (after removal of the geographically varying time mean), atmospheric pressure and wave height show a -30% correlation, atmospheric pressure and water vapor a -10% correlation, both pressure and water vapor a 7% correlation with residual sea level, and a bit surprisingly, ionospheric electron content and wave height a 15% correlation. Only the ocean tide is totally uncorrelated with other corrections or residual sea level. The effectiveness of three ionospheric corrections (TOPEX dual-frequency, a smoothed version of the TOPEX dual-frequency, and Doppler orbitography and radiopositioning integrated by satellite (DORIS) is also evaluated in terms of their reduction in variance of residual sea level. Smooth (90-200 km along-track) versions of the dual-frequency altimeter ionosphere perform best both globally and within 20 deg in latitude from the equator. The noise variance in the 1/s TOPEX inospheric samples is approximately (11 mm) squared, about the same as noise in the DORIS-based correction; however, the latter has its error over scales of order 10(exp 3) km. Within 20 deg of the equator, the DORIS-based correction adds (14 mm) squared to the residual sea level variance.

Zlotnicki, V.↗

A New Correction Technique for Strain-Gage Measurements Acquired in Transient-Temperature Environments

Significant strain-gage errors may exist in measurements acquired in transient-temperature environments if conventional correction methods are applied. As heating or cooling rates increase, temperature gradients between the strain-gage sensor and substrate surface increase proportionally. These temperature gradients introduce strain-measurement errors that are currently neglected in both conventional strain-correction theory and practice. Therefore, the conventional correction theory has been modified to account for these errors. A new experimental method has been developed to correct strain-gage measurements acquired in environments experiencing significant temperature transients. The new correction technique has been demonstrated through a series of tests in which strain measurements were acquired for temperature-rise rates ranging from 1 to greater than 100 degrees F/sec. Strain-gage data from these tests have been corrected with both the new and conventional methods and then compared with an analysis. Results show that, for temperature-rise rates greater than 10 degrees F/sec, the strain measurements corrected with the conventional technique produced strain errors that deviated from analysis by as much as 45 percent, whereas results corrected with the new technique were in good agreement with analytical results.

Richards, W. Lance↗

Correcting Attenuation of Reflectivity in Terminal Doppler Weather Radar

This paper documents the implementation of the algorithm for correcting attenuations in the TDWR reflectivity, and examines the impacts of performing the correction algorithm on the accuracy of the resultant precipitation products on the basis of stage IV gauge-radar analyses over six storm events (four warm season events and two cool season events). Three primary findings are summarized below: 1. Correcting for attenuation tends to improve the overall bias, the conditional bias, and the correlation between the TDWR-based rainfall estimates and stage IV values regardless of season and correction schemes. 2. Attenuation correction is overall beneficial to the accuracy of resulting rainfall estimates for the warm season. By contrast, for the cool season, despite potential improvements in the bias and correlation, attenuation correction can be undesirable when there is clear evidence of bright band enhancement arising from low freezing levels. To elaborate, in these situations spurious high precipitation rates over the melting layer can yield elevated values in specific attenuation factor K, which in turn, may lead to an artificially higher reflectivity adjustment at farther range. 3. Ingesting 3-D spatially variable RUC temperature and imposing a temperature threshold in general tend to degrade the accuracy of corrected rainfall estimates for the warm season. For the cool season, in theory they would help avoid applying correction to areas within and above the melting layer. In practice, due to the variable depth of the melting layer below the freezing level, it is difficult to determine the temperature for the lower boundary of the melting layer a priori.

Ding, Feng↗