Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “core sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Thermal design of the sample handling assembly in the sampling and caching subsystem on the Mars 2020 rover

The Mars 2020 Rover is scheduled to land on Mars on February 18, 2021. One of the primary mission objectives for the Mars 2020 Rover is to collect a set of Martian regolith samples for potential future return to Earth. Regolith and rock samples will be collected and placed into sample tubes using a coring drill, located at the end of a large Robotic Arm, on the outside of the rover. Filled sample tubes will be transferred from the outside of the Rover into the Adaptive Caching Assembly (ACA), located inside the Rover chassis, via the Bit Carousel. Once the filled sample tube is brought into the ACA, the Sample Handling Assembly (SHA) will transfer it to all of the internal processing stations of the ACA for volume assessment, sealing and finally drop-off on the Martian surface. The ACA is a volume within the rover chassis that is not temperature-controlled. Actuators inside the SHA and its End Effector (EE) must be warmed to above -55°C and -25°C, respectively, prior to use. This paper discusses the thermal design of the SHA that uses heaters and temperature sensors to warm up and maintain the temperature-sensitive arm components within temperature limits during operation. Thermal performance predictions for Mars surface operations are also presented.

Lee, Chern-Jiin↗

Preliminary Examination Process of Apollo Core 73002 - Insights and Lessons Learned From ANGSA for Future Sample Return Missions

Apollo Sample 73002 is part of a 2-foot long “drive tube” (73001/73002) of regolith that was collected from a landslide deposit near Lara Crater at the Apollo 17 site, Station 3. The double drive tube is believed to have penetrated a lunar landslide deposit that was transported from the slope of the South Massif into the TLV [1]. As part of the ANGSA (Apollo Next Generation Sample Analyses) initiative, preparing preliminary examination (PE) catalog of 73002 is a crucial first step for the early identification of material types such as rock fragments, and potential stratigraphy within the core. PE of Apollo core 73002 is distinct from science activities with the main goal to produces a sample catalog with a level of detail about sample characterization that is sufficient for the ANGSA PIs (and later on the lunar sample community) to select and request the samples to conduct their individual, scientific studies. Ultimately, the PE catalog of 73002 will help to establish a better understanding of the stratigraphy of the land slide deposit; the processes of the landslide including the trigger(s) and possibly number of landslide events, as well as the role of volatiles [1] and will aid in the careful preservation of the material for future studies [2].

Apollo↗

Bolometric temperature and young stars in the Taurus and Ophiuchus complexes

We calculated bolometric temperature (T(sub bol)) and luminosity (L(sub bol)) for 128 young stellar objects (YSOs) in Taurus, 74 in the Ophiuchus 'core', and 33 in the Ophiuchus 'off-core' region. We have constructed the bolometric luminosity-temperature (BLT) diagram, the log-log plot of L(sub bol) versus T(sub bol), for the three samples. T(sub bol) is defined as the temperature of a blackbody having the same frequency as the observed continuum spectrum. It measures the redness (or coldness) of an astronomical source. The BLT diagram is analogous to the H-R diagram and allows for a direct and quantitative comparison of YSOs at a wide variety of evolutionary states, ranging from the most deeply embedded stars to T Tauri stars nearly on the main sequence. We found (1) T(sub bol) increases monotonically from embedded sources (approximately 60-500 K) to classical T Tauri stars (approximately 1000-3000 K) to weak-line T Tauri stars (approximately 2000-5000 K); (2) T(sub bol) correlates reasonably well with the age inferred from the evolutionary models of pre-main-sequence stars and protostars for embedded 'protostars' and weak-line T Tauri stars. There is no significant correlation for the classical T Tauri stars. These results can be understood in terms of dissipation of circumstellar dust envelope and disk during the early stages of stellar evolution. Sources in the three regions have different distributions in the BLT diagram. The Ophiuchus core has the highest fraction of cold sources among the three regions. These cold sources are also more luminous than the YSOs in the other regions. The Ophiuchus off-core sample is dominated by the more evolved pre-main-sequence stars. The Taurus sources have distributions intermediate in L(sub bol), T(sub bol), and age between the Ophiuchus core and off-core distributions. These may suggest differences in the star formation history, and possibly in the stellar masses and mass accretion rates in these star-forming regions.

Chen, H.↗

Radioactivities in returned lunar materials and in meteorites

Carbon 14 terrestial ages were determined with low level minicomputers and accelerator mass spectrometry on 1 Yamato and 18 Allan Hills and nearby sited meteorites. Techniques for an accelerator mass spectrometer which make C(14) measurements on small samples were developed. Also Be(10) concentrations were measured in Byrd core and Allan Hills ice samples.

Fireman, E. L.↗

On the effects of filtering on convective-core statistics

Analysis of convective events north of Australia during the equatorial Monsoon Experiment (EMEX) reinforces accumulating evidence that convective cores over the tropical ocean are weak, with small diameters and vertical velocities. Superposition of smaller-scale turbulence on the convective core signal could yield artificially small cores, and thus produce sampling bias by aircraft. To investigate this potential source of bias, a side-by-side analysis of filtered and unfiltered vertical velocity data was performed while investigating the EMEX convective cores. Data were collected by the NOAA P3 and NCAR Electra using filtered (Graham filter) and non-filtered cores. The effects of filtering vertical velocity data to identify updraft and downdraft cores were noticeable but smaller than expected. Updraft cores had a vertical velocity greater than 1 m/sec for at least 500 m, and downdraft cores were defined analogously so that the filter eliminated events with less than a 500 m apparent diameter. Median and 10 percent core diameters were increased by 20-25 percent at most, with larger increases at higher levels (fewer small events). The maximum vertical velocity was changed only by changing the individual events in the distribution, but changes were detectable. At the lower levels, where many small, weak cores are introduced by filtering, average vertical velocity for the updraft cores was lowered by up to around 10 percent. Mass flux was changed the least, since diameter and mean vertical velocity respond to filtering in opposite ways. The filtering procedure increased total mass flux slightly due to inclusion of more upward moving air into the sample.

Lemone, Margaret A.↗

The Collection, Usage, and Preliminary Examination of the Apollo Sample Suite: Lessons for Artemis

Apollo Sample Collection and Usage: From 1969 to 1972 there were six Apollo missions to the surface of the Moon during which the astronauts collected 382 kg of rock and regolith (~2200 samples). The samples collected fall into these general categories: rocks (~66% by mass), rake samples (~4%), bulk regolith (~24%), and specialty regolith (deep drill cores, drive tubes, sealed bulk regolith) samples (~6%). In each category there are a variety of different subtypes available for study, e.g., among the bulk regolith samples there are also skim, trench, and (partially) shaded regolith samples each sampling unique types or depths of regolith. This variety of subsamples has enabled a multitude of different studies over the past 55 years (>3400 individual requests). We are still averaging ~50 unique requests and have allocated >500 individual Apollo samples annually for the past 10 years (2020 excepted). Looking at the 4,675 non-ANGSA (Apollo Next Generation Sample Analysis) samples allocated over the past 10 years, the proportions of allocated samples do not precisely align with the abundance (by mass) of those samples withing the collection: Rock (69.4 %); Rake (10.8 %); Bulk Regolith (15.5 %); Drive Tube (3.3 %); Core/Specialty (1.0 %). Apollo Preliminary Examination (PE): The PE process differs significantly for the various sample types enumerated above; we focus on regolith and rock samples here. During the Apollo mission era, the PE process evolved over the course of the missions; below is what was done for the Apollo 17 mission. For regolith samples, the PE process was: (1) documented bags containing regolith are opened, photographed, and described; (2) large rocks are removed and treated separately; (3) 25% to 33% of the bulk soil is scooped out, weighed, and stored in reserve; (4) the remaining sample is sieved to produce the size fractions <1, 1- 2, 2-4, and 4-10 mm, all of which are weighed. For rock samples, the process is: (1) removing rocks from the container(s) it came back from the Moon in; (2) rematching any materials that spalled off the rock to their original location; (3) numbering, weighing, and basic photographic documentation; (4) dusting with a gentle N2 gas jet; (5) Orthogonal photography; (6) detailed description of the textures and features of the rock; (7) rock modelling and measurement; (8) stereophotography; (9) determination of the orientation of the rock on the lunar surface. Drive tubes and deep drill cores were not characterized during PE beyond an initial weight and a sketch of the interior tube materials derived from 2D medical X-ray images. Catalogs: The ongoing utility of the Apollo samples is enabled by the robust cataloguing process for the samples [3-5], which allows the scientific community to accurately request samples uniquely suited to their proposed studies. A common misconception, however, is the amount of detail that goes into the initial catalog (e.g., [6]) for a collection from the preliminary examination (PE) period, versus what goes into the catalogs that come later in the life cycle of the samples from that mission (e.g., [7]). The only required data for a PE catalog is a weight, a basic photograph, and a description of the nature of the sample. Artemis PE: Over the past few years, the ongoing ANGSA project studied previously unopened Apollo 17 double drive tube samples 73001/2 [1], and a PE of the drive tubes was done. The PE took the existing core dissection process (developed during PE of Apollo cores in the 1970s, 1980s), and modernized it [7]. The main lesson from the ANGSA PE relative to future missions was that the physical work done during PE of lunar samples has not changed much over the past 5 decades. The use of “modern” technology during PE (e.g., XCT; multispectral analyses) resulted in an enhanced initial understanding of the 73001 and 73002 drive tubes, but greatly increased the time required. The lessons learned from recent astromaterial PEs (e.g., ANGSA and OREx) are important to consider when planning for Artemis, but the unique nature of the Artemis Campaign means many lessons learned from these mission will not be applicable. Given the time constraints (6 months) and likely number of samples that will be returned by Artemis (>200), the Artemis PE catalog will necessarily look much more like [4] than [6].

J Gross↗

Comparative Results of Using Different Methods for Discovery of Microorganisms in very Ancient Layers of the Central Antarctic Glacier above the Lake Vostok

The ice sheet of the Central Antarctic is considered by the scientific community worldwide, as a model to elaborate on different methods to search for life outside Earth. This became especially significant in connection with the discovery of the underglacial lake in the vicinity of the Russian Antarctic Station Vostok. Lake Vostok is considered by many scientists as an analog of the ice covered seas of Jupiter's satellite Europa. According to the opinion of many researchers there is the possibility that relict forms of microorganisms, well preserved since the Ice Age, may be present in this lake. Investigations throughout the thickness of the ice sheet above Lake Vostok show the presence of microorganisms belonging to different well-known taxonomic groups, even in the very ancient horizons near close to floor of the glacier. Different methods were used to search for microorganisms that are rarely found in the deep ancient layers of an ice sheet. The method of aseptic sampling from the ice cores and the results of controlled sterile conditions in all stages when conducting these investigations, are described in detail in previous reports. Primary investigations tried the usual methods of sowing samples onto different nutrient media, and the result was that only a few microorganisms grew on the media used. The possibility of isolating the organisms obtained for further investigations, by using modern methods including DNA-analysis, appears to be the preferred method. Further investigations of the very ancient layers of the ice sheet by radioisotopic, luminescence, and scanning electron microscopy methods at different modifications, revealed the quantity and morphological diversity of the cells of microorganisms that were distributed on the different horizons. Investigations over many years have shown that the microflora in the very ancient strata of the Antarctic ice cover, nearest to the bedrock, support the effectiveness of using a combination of different methods to search for signs of life in ancient icy formations, which might play a role in the long-term preservation and transportation of microbial life throughout the Universe.

Abyzov, S. S.↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

Core expansion in young star clusters in the Large Magellanic Cloud

The core radii of 18 rich star clusters in the LMC with ages from 10 Myr to 1 Gyr. Data for an additional 17 clusters with ages from 1 Myr to 10 Gyr are available in the literature. The combined sample shows that the core radii increase from about 0 to about 5 pc between about 1 Myr and 1 Gyr, and then begin to decrease again. The expansion of the cores is probably driven by mass loss from evolving stars. Models of cluster evolution show that the rate of increase in core radius is sensitive to the slope of the initial mass function. The observed core radius-age relation for the LMC clusters favors an intial mass function with slope slightly flatter than the Salpeter value.

Elson, Rebecca A. W.↗

Visualization and Quantification of Rotor Tip Vortices in Helicopter Flows

Helicopter aeromechanics encompasses a highly vortical flow field. The vortices generated at each blade tip contain unsteady, complex, three-dimensional structures, which interact with each other, other blades, the fuselage and various components of the helicopter. It is crucial to understand vortex kinematics and their subsequent dynamic evolution. Much research has been devoted to the understanding of helicopter vortex dynamics, including a number of experimental studies.1-6 In May 2010 Particle Image Velocimetry (PIV) measurements of a full-scale UH-60A rotor were acquired in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel.1 These measurements were taken at a plane just downstream of the advancing blade in the vicinity of the blade tip—the so-called PIV plane. The resulting PIV data were then processed using an ensemble-average approach to create graphical representations of the vortical wake velocity and vorticity fields, which, in turn, have enhanced the understanding of rotorcraft vortical wake flow field physics and have provided a more detailed validation of vortical wake computer simulations.7 A common approach used to analyze flow field features is to compute and plot color contour maps of various scalar quantities such as pressure, velocity magnitude and vorticity magnitude. For example, the color map of the vorticity magnitude is typically used to determine vortical flow structure. With this approach the vortex core may appear larger or smaller, depending on the contour levels that are selected. Thus, the resulting visualization is sensitive to user-specified contour levels. For vortex core radius measurements, it is more accurate to calculate the vortex core radius using the cross-flow velocity profile across the vortex core. The task of extracting the cross-flow velocity profile can be time consuming with existing tools since the user needs to manually select the core center then specify sampling points along the profile axis. The task becomes even more challenging when the associated grid system uses AMR (Adaptive Mesh Refinement) where the profile axis could span multiple grid blocks. There are a number of existing techniques for profiling of vortex core attributes;8-9 however, these techniques are not fully automatic in that the user still needs to select the vortex core center to compute the cross-flow velocity profile. The present study introduces a new color map scheme that is based on the vortex core radius, which is fully automatic and does not require user intervention. Analysis and visualization of blade tip vortices on the PIV plane using the proposed new color map scheme are described in Section II. The new approach is evaluated using two case studies, which are described in Section III. The paper ends with a summary in Section IV.

Quantification↗

Mars 2020 Coring Drill: Prototype Testing and Analysis

The Mars 2020 rover will carry a new subsystem to collect and prepare Martian rocks and regolith (loose, unconsolidated) samples. This includes a rotary percussive coring drill and a set of sample tubes. About 30 of these sample tubes will be deposited at select locations for return on a potential future sample-retrieval mission. In laboratories on Earth, specimens from Mars could be analyzed for evidence of past life on Mars and possible health hazards for future human missions. Hardware and control algorithms for the coring drill are based heavily on testing. Results from testing of prototype hardware are used to refine the design

Kreichbaum, Kristopher↗

In Situ Carbon and Sulfur Isotope Analysis of Archean Organic Matter and Pyrite

Stable isotopic compositions of biologically important elements (e.g., C and S) in sedimentary rocks are valuable biosignatures to the extent that they indicate the presence and variable expression of microbial metabolisms in space and time. Strong interactions between the carbon and sulfur cycles (e.g., via organic matter remineralization during microbial sulfate reduction) make coordinated, in situ C and S isotope analysis by secondary ion mass spectrometry (SIMS) a particularly powerful tool. In rocks ranging in age from 2.7-2.5 Ga, expansions in the ranges of delta C-13 of organic matter and delta S-34 of pyrite likely reflect the increasing influence of oxygenic photosynthesis in the surface ocean (as well as methane and sulfur metabolisms in deeper waters), whereas the large range of mass independent sulfur isotope fractionation (Delta S-33) suggests that the atmosphere remained anoxic until approx 2.4 Gyr ago. We report in situ delta C-13 measurements of organic matter in the approx 2.7-2.6 Ga Carawine Dolomite, Marra Mamba Iron Formation, and Jeerinah, Wittenoom, and Tumbiana Formations, as well as the approx 2.5 Ga Mount McRae Shale. We also report in situ delta S-24 and Delta S-33 measurements of pyrite associated with organic matter in a subset of these samples. In a single square cm sample of the Tumbiana Formation with bulk delta C-13(sub org) of -49.7% (VPDB), two distinct kerogen types have delta C-13 values, measured in situ, consistent with oxygenic photosynthesis (-33%) and methane metabolism (-52%). In a sample from the ABDP-9 core, radiobitumen associated with a uraniferous mineral grain is C-13-enriched by 8% (-26.8%0) relative to average in situ kerogen (-34.9%0) and similar in delta C-13 to solvent extractable hydrocarbons from the Mount McRae Shale (avg delta C-13 = -27.1 %). Average reproducibility for delta C-13 was 0.4% (2 SD) using a 6 micron spot and 0.8% using a 3 micron spot. In situ sulfur isotope analyses of 33 authigenic pyrite grains in 3 samples of the ABDP-9 core using a 10 micron spot (2 SD reproducibility = 0.4% for delta S-34 and -0.1% for Delta S-33) show a range of 28.1 % in delta S-34 (-10.3 to 17.8%) and 13.3%0 in Delta S-33 (-3.8 to 9.5%), whereas the range from 132 bulk analyses across 84 m of core is 19.4% for delta S-34 and 11.5% for Delta S-33. Coordinated, in situ carbon and sulfur isotope analyses in one ABDP-9 sample are shown. In situ values from this kerogen-pyrite association are within 0.1% of the bulk value in the case of delta C-13 and higher by several permil in the case of delta S-34 and Delta S-33. Coordinated in situ carbon and sulfur isotope analyses in rocks deposited during key intervals of environmental change (e.g., the Great Oxidation Event) can refine our understanding of the mode and tempo of change. In Earth's oldest sedimentary rocks, and in extraterrestrial samples, these coordinated in situ analyses may reveal biosignatures in the form of isotopic correlations at the scale of individual microorganisms and their microhabitats.

Williford, K. H.↗

Lunar core 15010/11 - Grain size, petrology, and implications for regolith dynamics

Petrographic observations of six samples from various depths show that core 15010/11 is relatively homogeneous and consists mostly of basalt fragments and minerals derived from basalts. However, it also contains an appreciable highland component nearly equally distributed among the fine-grained fraction, dark matrix breccia and identifiable highland grains, and agglutinates. Grain size data and agglutinates show that this core is not mature and does not contain a well developed reworking profile. The unusual properties of the core are thought to be a direct result of its close proximity to the rim of Hadley Rille. This location favors relatively rapid regolith erosion into the rille, produces a thin regolith, and provides an abundant supply of bedrock-derived ejecta.

Mckay, D. S.↗

Geochemical stratigraphy of two regolith cores from the Central Highlands of the moon

High-resolution concentration profiles are presented for 20-22 chemical elements in the under 1-mm grain-size fractions of 60001-7 and 60009/10. Emphasis is placed on the stratigraphic features of the cores, and the fresh results are compared with those of previous petrographic and geochemical studies. For elements associated with major mineral phases, the variations in concentration in both cores exceed that observed in some 40 samples of surface and trench soils. Most of the variation in lithophile element concentrations at depths of 18 to 21 cm results from the mixing of two components - oil that is relatively mafic and rich in incompatible trace elements (ITEs), and coarse-grained anorthosite. The linearity of mixing lines on two-element concentration plots argues that the relative abundances of these various subcomponents are sufficiently uniform from sample to sample and from region to region in the core that the mixture behaves effectively as a single component. Soils at depths of 52-55 cm exhibit very low concentrations of ITEs.

Korotev, R. L.↗

Stratigraphy and depositional history of the Apollo 17 drill core

Lithologic abundances obtained from modal analyses of a continuous string of polished thin sections indicate that the Apollo 17 deep drill core can be divided into three main zones: An upper zone (0-19 cm depth) characterized by high abundances of agglutinates (30%) and a high ratio of mare to non-mare lithic fragments (less than 0.8); a coarse-grained layer (24-56 cm) rich in fragments of high-Ti mare basalts and mineral fragments derived from them, and poor in agglutinates (6%); and a lower zone (56-285 cm) characterized by variable but generally high agglutinate abundances (25%) and a low ratio of mare to nonmare lithic fragments (0.6). Using observations of the geology of the landing site, the principles of cratering dynamics, and the vast amount of data collected on the core, the following depositional history for the section of regolith sampled by the Apollo 17 drill core: was devised.

Taylor, G. J.↗

Depositional history of core section 74001 - Depth profiles of maturity, FeO, and metal

Samples from every 0.5-cm interval of soil in core section 74001 have been studied by ferromagnetic resonance (FMR) and magnetic techniques. The values of the FMR maturity index show that the 74001 samples are very immature (the index ranges from 0.14 to 0.29 units) and have not seen appreciable, if any, surface exposure since their deposition. In fact, the small amount of fine-grained metal in the 74001 samples is probably not acquired as a result of their exposure to the micrometeoroid flux at the lunar surface. Thus, the black-glass soil of 74001 was deposited very rapidly, probably in a single episode or several closely spaced episodes of lunar fire fountaining. The average concentration of FeO and its standard deviation for all the 74001 samples are 22.5 + or - 0.3 wt.%. Since the FeO concentration is so uniform, no large variations in the major-element chemistry of 74001 are expected, with the possible exception of the volatile elements. The concentration of coarse-grained metal, which is measured magnetically, and its standard deviation are 0.15 + or - 0.01 wt.%. The coarse-grained metal probably precipitated contemporaneously with the silicate and oxide phases in the black-glass droplets.

Morris, R. V.↗

Lunar Polar Coring Lander

Plans to build a lunar base are presently being studied with a number of considerations. One of the most important considerations is qualifying the presence of water on the Moon. The existence of water on the Moon implies that future lunar settlements may be able to use this resource to produce things such as drinking water and rocket fuel. Due to the very high cost of transporting these materials to the Moon, in situ production could save billions of dollars in operating costs of the lunar base. Scientists have suggested that the polar regions of the Moon may contain some amounts of water ice in the regolith. Six possible mission scenarios are suggested which would allow lunar polar soil samples to be collected for analysis. The options presented are: remote sensing satellite, two unmanned robotic lunar coring missions (one is a sample return and one is a data return only), two combined manned and robotic polar coring missions, and one fully manned core retrieval mission. One of the combined manned and robotic missions has been singled out for detailed analysis. This mission proposes sending at least three unmanned robotic landers to the lunar pole to take core samples as deep as 15 meters. Upon successful completion of the coring operations, a manned mission would be sent to retrieve the samples and perform extensive experiments of the polar region. Man's first step in returning to the Moon is recommended to investigate the issue of lunar polar water. The potential benefits of lunar water more than warrant sending either astronauts, robots or both to the Moon before any permanent facility is constructed.

Angell, David↗

Depositional history of the Apollo 16 deep drill core

Ferromagnetic resonance and magnetic hysteresis loop measurements were performed on 212 samples from the Apollo 16 deep drill core. The total iron content is generally uniform with a mean value of 5.7 plus or minus 0.9 wt%. The soils range in maturity from immature to mature. Two major contacts were observed. The contact at 13 cm depth represents a fossil surface whereas the contact at 190 cm depth has no time-stratigraphic significance. The data suggest that the core section below 13 cm depth was deposited in a single impact event and subjected to meteoritic gardening for about 450 m.y. However, our data do not preclude deposition by a series of closely spaced events. About 50 m.y. ago, the top 13 cm were added. Comparison with the Apollo 16 double drive tube 60009/60010 does not yield any evidence for a stratigraphic correlation with the deep drill core.

Gose, W. A.↗