Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control room design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Quench and Partitioning Steels

Quench and Partitioning (Q&P) steels are produced by implementing a unique thermal history designed to produce microstructures that contain martensite, and potentially ferrite, along with significant amounts of retained austenite stabilized by high carbon contents. Carbon-stabilized austenite is obtained by carbon transfer from martensite into austenite after a controlled amount of martensite is introduced by judicious selection of a so-called quench temperature at which quenching below the martensite start temperature is interrupted. Following the quench interruption, during the partitioning step, the steel is either held at the quench temperature or brought to a higher temperature and held for a specific time, to stimulate carbon transfer from martensite to austenite, to decrease the carbon supersaturation in martensite and correspondingly stabilize the austenite by carbon enrichment. A final quench to room temperature may be associated with the transformation of a certain fraction of austenite into secondary or “fresh” martensite, which is usually undesirable. A review of the Q&P process is presented, including prediction of austenite retention, alloying effects on its stabilization, a mechanical properties survey, including tensile and local formability relevant to sheet steels for automotive applications, along with perspectives on reactions competing with carbon partitioning that may operate during partitioning.

Kang, Singon↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental system for the control of surgically induced infections

The results are presented of the development tests performed on the experimental system for the control of surgically induced infections. Tests were performed on the portable clean room to demonstrate assembly, collapsability, portability and storage. Collapsing, relocating and storing within the surgery room can be accomplished in 12 minutes. The storage envelope dimensions are 1.64 m x 4.24 m x 2.62 m high. The disassembly transfer to another room, and reassembly were demonstrated. The laminar air flow velocity profile within the enclosure was measured. In the undisturbed area of the enclosure the air flow met the Federal Standard 209a requirements of 27.45 meters per minute + or - 6.10 meters per minute. Smoke tests with simulated surgery equipment and personnel in the enclosure did not indicate any detrimental air flow patterns. It is concluded that the system as designed will perform the functions required for its intended use.

Source record↗

Cold-Starting All-Solid-State Batteries from Room Temperature by Thermally Modulated Current Collector in Sub-Minute

All-solid-state batteries (ASSBs) show great potential as high-energy and high-power energy storage devices but their attainable energy/power density at room temperature is severely reduced because of the sluggish kinetics of lithium-ion transport. Here we first reported a thermally modulated current collector (TMCC), which can rapidly cold-start ASSBs from room temperature to operating temperatures (70–90 °C) in less than one minute, and simultaneously enhance the transient peak power density by 15-fold compared to one without heating. This TMCC is prepared by integrating a uniform, ultrathin (~200 nm) nickel layer as a thermal modulator within an ultralight polymer-based current collector. By isolating the thermal modulator from the ion/electron pathway of ASSBs, it can provide fast, stable heat control yet does not interfere with regular battery operation. Moreover, this ultrathin (13.2 μm) TMCC effectively shortens the heat transfer pathway, minimizes heat losses, and mitigates the formation of local hot spots. The simulated heating energy consumption can be as low as ~3.94% of total battery energy. This TMCC design with good tunability opens new frontiers towards smart energy storage devices in the future from the current collector perspective.

25 ENERGY STORAGE↗

Trap-Filling Magnetoconductance as an Initialization and Readout Mechanism of Triplet Exciton Spins

Photoexcited triplet states are promising candidates for hybrid qubit systems, as they can be used as a controlling gate for nuclear spins. But microwave readout schemes do not generally offer the sensitivity needed to approach the single-molecule limit or the scope to integrate such systems into devices. In this report we demonstrate the possibility of electrical readout of triplet spins at room temperature through a specific mechanism of magnetoconductance (MC) in polycrystalline pentacene. We show that hole-only pentacene devices exhibit a positive photoinduced MC response that is consistent with a trap-filling mechanism. Spin and magnetic-field-dependent quenching of photogenerated triplets by holes quantitatively explains the MC response we observe. These results are distinct in both sign and proposed mechanism compared to previous reports on polyacene materials and provide clear design rules for future spintronic devices based on this spin-sensing mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rotordynamic Analysis and Feasibility Study of a Disk Spin Test Facility for Rotor Health Monitoring

Recently, National Aeronautics and Space Administration (NASA) initiated a program to achieve the significant improvement in aviation safety. One of the technical challenges is the design and development of accelerated experiments that mimic critical damage cases encountered in engine components. The Nondestructive Evaluation (NDE) Group at the NASA Glenn Research Center (GRC) is currently addressing the goal concerning propulsion health management and the development of propulsion system specific technologies intended to detect potential failures prior to catastrophe. For this goal the unique disk spin simulation system was assembled at NASA GRC, which allows testing of rotors with the spinning speeds up to 10K RPM, and at the elevated temperature environment reaching 540 C (1000 F). It is anticipated that the facility can be employed for detection of Low Cycle Fatigue disk cracking and further High Cycle Fatigue blade vibration. The controlled crack growth studies at room and elevated temperatures can be conducted on the turbine wheels, and various NDE techniques can be integrated and assessed as in-situ damage monitoring tools. Critical rotating parts in advanced gas turbine engines such as turbine disks frequently operate at high temperature and stress for long periods of time. The integrity of these parts must be proven by non-destructive evaluation (NDE) during various machining steps ranging from forging blank to finished shape, and also during the systematic overhaul inspections. Conventional NDE methods, however, have unacceptable limits. Some of these techniques are time-consuming and inconvenient for service aircraft testing. Almost all of these techniques require that the vicinity of the damage is known in advance. These experimental techniques can provide only local information and no indication of the structural strength at a component and/or system level. The shortcomings of currently available NDE methods lead to the requirement of new damage detection techniques that can provide global information on the rotating components/system, and, in addition, they do not require direct human access to the operating system. During this period of research considerable effort was directed towards the further development of experimental facility and development of the vibration-based crack detection methodology for rotating disks and shafts. A collection of papers and reports were written to describe the results of this work. The attached captures that effort and represents the research output during the grant period.

Sawicki, Jerzy T.↗

Controlling Valley-Specific Light Emission from Monolayer MoS 2 with Achiral Dielectric Metasurfaces

Excitons in two-dimensional transition metal dichalcogenides have a valley degree of freedom that can be optically manipulated for quantum information processing. Here, we integrate MoS 2 monolayers with achiral silicon disk array metasurfaces to enhance and control valley-specific absorption and emission. Through the coupling to the metasurface electric and magnetic Mie modes, the intensity and lifetime of the emission of neutral excitons, trions, and defect bound excitons can be enhanced and shortened, respectively, while the spectral shape can be modified. Additionally, the degree of polarization (DOP) of exciton and trion emission from the valley can be symmetrically enhanced at 100 K. The DOP increase is attributed to both the metasurface-enhanced chiral absorption of light and the metasurface-enhanced exciton emission from the Purcell effect. Finally, combining Si-compatible photonic design with large-scale 2D materials integration, our work makes an important step toward on-chip valleytronic applications approaching room-temperature operation.

2D materials↗

Test program, helium II orbital resupply coupling

The full scope of this program was to have included development tests, design and production of custom test equipment and acceptance and qualification testing of prototype and protoflight coupling hardware. This program was performed by Ball Aerospace Systems Division, Boulder, Colorado until its premature termination in May 1991. Development tests were performed on cryogenic face seals and flow control devices at superfluid helium (He II) conditions. Special equipment was developed to allow quantified leak detection at large leak rates up to 8.4 x 10(exp -4) SCCS. Two major fixtures were developed and characterized: The Cryogenic Test Fixture (CTF) and the Thermal Mismatch Fixture (Glovebox). The CTF allows the coupling hardware to be filled with liquid nitrogen (LN2), liquid helium (LHe) or sub-cooled liquid helium when hardware flow control valves are either open or closed. Heat leak measurements, internal and external helium leakage measurements, cryogenic proof pressure tests and external load applications are performed in this fixture. Special reusable MLI closures were developed to provide repeatable installations in the CTF. The Thermal Mismatch Fixture allows all design configurations of coupling hardware to be engaged and disengaged while measuring applied forces and torques. Any two hardware components may be individually thermally preconditioned within the range of 117 deg K to 350 deg K prior to engage/disengage cycling. This verifies dimensional compatibility and operation when thermally mismatched. A clean, dry GN2 atmosphere is maintained in the fixture at all times. The first shipset of hardware was received, inspected and cycled at room temperature just prior to program termination.

Hyatt, William S.↗

Fuel Cell Power Plant Initiative: Solid Oxide Fuel Cell/Logistics Fuel Processor 27 kWe Power System Demonstration for ARPA - Volume 1

This report describes the successful testing of a 27 kWe Solid Oxide Fuel Cell (SOFC) generator fueled by natural gas and/or a fuel gas produced by a brassboard logistics fuel preprocessor (LFP). The test period began on May 24, 1995 and ended on February 26, 1996 with the successful completion of all program requirements and objectives. During this time period, this power system produced 118.2 MWh of electric power. No degradation of the generator's performance was measured after 5582 accumulated hours of operation on these fuels: local natural gas - 3261 hours, jet fuel reformate gas - 766 hours, and diesel fuel reformate gas - 1555 hours. This SOFC generator was thermally cycled from full operating temperature to room temperature and back to operating temperature six times, because of failures of support system components and the occasional loss of test site power, without measurable cell degradation. Numerous outages of the LFP did not interrupt the generator's operation because the fuel control system quickly switched to local natural gas when an alarm indicated that the LFP reformate fuel supply had been interrupted. The report presents the measured electrical performance of the generator on all three fuel types and notes the small differences due to fuel type. Operational difficulties due to component failures are well documented even though they did not affect the overall excellent performance of this SOFC power generator. The final two appendices describe in detail the LFP design and the operating history of the tested brassboard LFP.

Veyo, S.E.↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a HTGR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts over the past decades have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near-term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR ha s undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform high-temperature gas reactor (HTGR) safety evaluations. The generic plant model is based on publicly available PMBR-400 design information. For plant aspects (e.g., reactor building size and leak rate) that are not described in the PBMR-400 references, the analysts made assumptions needed to construct a MELCOR full-plant model. The HTGR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to a recuperative heat exchange r. Surrounding the reactor vessel is a reactor cavity contained within a confinement room cooled by the Reactor Cavity Cooling System (RCCS). Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, primary system heat removal and reactor vessel decay heat removal, and confinement cooling.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Overview of Quantum Sensing Materials and Techniques for Energy Sector Applications

The energy sector has become increasingly dependent upon highly sensitive sensing devices for a wide range of applications. Variables such as temperature, pH, electromagnetic fields, ions, and pressure must be measured with high precision, often in harsh conditions (e.g. highly corrosive environments due to high temperature, pressure and humidity). These sensors are deployed in infrastructure such as transformers, pipelines, mines, nuclear power plants, and other areas to ensure safe operating conditions and uninterrupted, optimized service. Moreover, new opportunities for sensors have emerged due to the expansion of smart grids/meters, driverless vehicles, and the discovery of new oil, gas, and critical mineral deposits. The continued maturation of quantum sensing technologies offers exciting opportunities for quantum-enhanced measurements within the energy sector that may provide significant improvements in sensitivity beyond the classical limit. Here, an overview of established and emerging quantum materials for sensing applications will be provided, from trapped ions to color centers in diamond and silicon carbide. Associated quantum sensing methods for these materials will be discussed, with an emphasis on platforms that are nearing commercial viability. Specific application opportunities within the energy sector for quantum sensors will then be analyzed, including oil/gas discovery, greenhouse gas emission monitoring, pH and ion sensing, current measurement in electric vehicle batteries, and quantum-enhanced spectroscopy. Remaining barriers, such as quantum sensor platform miniaturization and ruggedization, will also be analyzed. A specific project at the National Energy Technology Laboratory involving the functionalization of qubits using metal-organic frameworks for enhanced quantum sensing will also be highlighted. Here, nitrogen vacancy centers (NV) in nanodiamonds, a commercially available qubit with long coherence times and utilizable quantum properties at room temperature, are encapsulated in a controlled way using the metal-organic framework ZIF-8. The ZIF-8 provides a well-defined, porous scaffold that can be controlled to promote the selective uptake of specific target analytes, such as gas molecules or ions. The quantum sensing performance of this composite material is either preserved or enhanced following ZIF-8 encapsulation; the optically detected magnetic resonance response of the NV nanodiamonds with and without the ZIF-8 coating are identical, while the ZIF-8 coating increases the longitudinal spin relaxation lifetime (T1) of the NV centers, an important parameter for spin relaxometry-based quantum sensing experiments. Taken together, these results demonstrate the importance of qubit functionalization as a crucial step for rationally designing high performance quantum sensors.

Crawford, Scott↗

Space shuttle development Motor No. 9 (DM-9), volume 1

The results obtained during the December 23, 1987 static firing of the DM-9 test article are presented. The DM-9 full-scale static test article employed redesigned solid rocket motor (RSRM) field joint capture feature hardware with J-seal insulation configuration, and nozzle-to-case joint radial bolt design with bonded insulation configuration. The nozzle incorporated RSRM components, including a thicker cowl with involuted outer boot ring. The nozzle employed redundant and verifiable seals in all five joints, and room temperature vulcanization backfill in three joints. With very few exceptions, the DM-9 test article was flight configuration. The test was conducted under extreme weather conditions: temperature of 25 F and wind at 15 to 20 mph. Ballistics performance values were within specification requirements. The RSRM field joint (J-seal) insulation configuration functioned as predicted with no indication of hot gases reaching the capture feature O-rings. There was a blowhole in the polysulfide adhesive in the nozzle-to-case joint, but no evidence of hot gases past the wiper O-ring. Nozzle design changes appeared to perform nominally, with the exception of the outer boot ring, which suffered partial structural breakup late in the test. Field joint heaters maintained the controlling resistance temperature device temperature within the specified requirements during heater operation. The thrust vector control system operated properly. The redesigned water deluge system, temperature conditioning equipment, and other test support equipment performed as planned.

Garecht, Diane M.↗

Power Electronics Being Developed for Deep Space Cryogenic Applications

Electronic circuits and systems designed for deep space missions need to operate reliably and efficiently in harsh environments that include very low temperatures. Spacecraft that operate in such cold environments carry a large number of heaters so that the ambient temperature for the onboard electronics remains near 20 C. Electronics that can operate at cryogenic temperatures will simplify system design and reduce system size and weight by eliminating the heaters and their associated structures. As a result, system development and launch cost will be reduced. At the NASA Glenn Research Center, an ongoing program is focusing on the development of power electronics geared for deep space low-temperature environments. The research and development efforts include electrical components design, circuit design and construction, and system integration and demonstration at cryogenic temperatures. Investigations are being carried out on circuits and systems that are targeted for use in NASA missions where low temperatures will be encountered: devices such as ceramic and tantalum capacitors, metal film resistors, semiconductor switches, magnetics, and integrated circuits including dc/dc converters, operational amplifiers, voltage references, and motor controllers. Test activities cover a wide range of device and circuit performance under simple as well as complex test conditions, such as multistress and thermal cycling. The effect of low-temperature conditions on the switching characteristics of an advanced silicon-on-insulator field effect transistor is shown. For gate voltages (VGS) below 2.6 V, drain currents at -190 C are lower than drain currents at room temperature (20 C).

Patterson, Richard L.↗

Conceptual design of a high reactive-power ferroelectric fast reactive tuner

We present a novel design of a ferroelectric fast reactive tuner (FE-FRT) capable of modulating mega-VAR reactive power on a submicrosecond timescale. The high reactive power capability of our design extends the range of applications of reactive tuners to numerous applications. We present a detailed analytical model of the performance of a megawatt-class reactive power device and benchmark it against finite-element method eigenmode and frequency domain electromagnetic simulations. We introduce new features, including an annulus design for the ferroelectric capacitors and capacitive window coupling to the cavity. We consider thermal design issues and nonlinear effects in the ferroelectric. The model covers several configurations, allowing control of the frequency of superconducting and normal-conducting cavities in a variety of applications and frequencies. We calculate that the FE-FRT designed should be capable of handling around 0.45 MVAR of reactive power with around 3 kW of resistive losses, providing a frequency tuning range of 8 kHz in an example of 400 MHz cavity geometry. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Atomic Ordering-Induced Ensemble Variation in Alloys Governs Electrocatalyst On/Off States

The catalytic behavior of a material is influenced by ensembles—the geometric configuration of atoms. Traditional approaches, mainly utilizing solid-solution alloys in electrocatalysis, have often overlooked the challenges posed by concurrent changes in the electronic structure (i.e. d-band center) when the composition is altered. Here, this study introduces a methodology that distinctly separates the geometric effects (i.e. ensembles) from the electronic structure. We compare the reactivity of compositionally identical, but structurally different Pd 3 Bi ordered intermetallic and solid-solution alloys. Remarkably, we find that Pd 3 Bi intermetallics display nearly no reactivity for the methanol oxidation (MOR), while their solid-solution counterparts have significant reactivity. This highlights a unique case where materials with identical chemical compositions demonstrate drastically different catalytic behavior underscoring the critical importance of ensembles in electrocatalysis. Specifically, Pd 3 Bi intermetallics form smaller ensembles (average coordination number: 4.5 ± 1.6) with almost no measurable MOR activity at room temperature, in contrast to the solid-solution Pd 3 Bi that exhibit larger ensembles (average coordination number: 6.8 ± 0.9) and considerable MOR reactivity (0.5 mA cm −2 Pd ). An ordered Pd 3 Bi alloy, with an intermediate ensemble size (average coordination number: 5.3 ± 1.2), displays moderate MOR activity (0.1 mA cm −2 Pd ), further confirming the direct correlation between ensemble size and catalytic activity. Notably, all Pd 3 Bi alloys maintain similar electronic structures, because the chemical composition of the alloys is fixed, indicating that the differences in reactivity are predominantly from changes to the ensemble size. Our findings offer an approach for precisely controlling catalytic activity through manipulating the geometric configuration of the atoms within an alloy, paving the way for more efficient catalyst design.

alloys↗

Engineering of Ferroic Orders in Thin Films by Anionic Substitution

Multiferroics are a unique class of materials where magnetic and ferroelectric orders coexist. The research on multiferroics contributes significantly to the fundamental understanding of the strong correlations between different material degrees of freedom and provides an energy-efficient route toward the electrical control of magnetism. While multiple ABO 3 oxide perovskites are identified as being multiferroic, their magnetoelectric coupling strength is often weak, necessitating the material search in different compounds. Here, the observation of room-temperature multiferroic orders in multi-anion SrNbO 3-x N x thin films is reported. In these samples, the multi-anion state enables the room-temperature ferromagnetic ordering of the Nb d-electrons. Simultaneously, ferroelectric responses that originate from the structural symmetry breaking associated are found with both the off-center displacements of Nb and the geometric displacements of Sr, depending on the relative O-N arrangements within the Nb-centered octahedra. So findings not only diversify the available multiferroic material pool but also demonstrate a new multiferroism design strategy via multi-anion engineering.

thin-films↗

Testing of a 15 kA Superconducting Transformer

Here, the manufacturing of superconducting magnets for High Energy Physics (HEP) and Fusion Energy Sciences (FES) applications requires high-current conductors to generate stronger magnetic fields without increasing the inductance of the magnet. Increased inductance is undesirable due to the associated AC losses, which reduce the temperature margin; and the quench protection also becomes complicated. Testing high-current conductors with a direct current (DC) room temperature power supply is unfeasible for two primary reasons: 1) the limited capacity to supply large currents, and 2) the significant heat load losses at the current leads. A superconducting transformer offers a solution to both challenges. A 50-kA superconducting transformer is planned for manufacturing and commissioning at Brookhaven National Laboratory as part of its user facility upgrade. This transformer will facilitate the testing of superconducting cables, conductors, joints, and insert coils under high magnetic field conditions (10 T) and with currents up to 50-kA. To evaluate the manufacturing process and validate the theoretical models, the magnet division has developed and tested a 15-kA prototype transformer. A control loop has been implemented to ensure precise current delivery to the sample. This paper presents the coil design, manufacturing, and experimental results from the cold tests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary Look at the LBEG & MPEG Beam Transmissions between HPSim and Operation Data

This report summarizes recent work on estimating the transmission of LANSCE H- beams from the end of the present DTL to both the PSR stripper foil (LBEG) and WNR target 4 (MPEG). The LBEG beam might be considered a more typical LINAC beam and lends itself to continuous monitoring of transmission through the various stages of the accelerator. For the MPEG, however, the widely-spaced micropulses and lack of the requisite sensitivity current monitors throughout the accelerator make these measurements extremely difficult and more uncertain. Therefore, to assist in estimating the MPEG beam transmission, beam-dynamics simulations using HPSim were employed. These beam transmission estimates from the end of the Drift Tube Linac (DTL) to Target 4 (MPEG) and the PSR stripper foil (LBEG) are vital to determine the charge requirements for LAMP’s front end. In this technote, we demonstrate three major efforts in determining the transmission: (1) Convert the WNR beamline lattice from TRANSPORT to HPSim for use in the simulation; (2) Simulate the optimization process in the Central Control Room (CCR) that brings down the losses by up to a factor of 4000 between the end of the initial physics-based tuneup phase and production beam operation; (3) Analyze operational data to deduce measured transmissions. Table 1 shows the estimated losses with HPSim and operational analysis. Finally, a better measurement and other improvements to refine the results are also proposed.

43 PARTICLE ACCELERATORS↗