Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consumption potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemical Nutrient Recovery for the Food–Energy–Water Nexus at Municipal Wastewater Facilities: Multivariate Analyses of Seasonal Sampling and Reactor Performance

Digester-equipped municipal wastewater facilities generate recycle streams with high nutrient loads that increase energy consumption and can cause environmental pollution. The reduction of these loads through electrochemical nutrient recovery (ENR) could enhance the food–energy–water nexus by producing fertilizer (struvite). This study investigated the recovery process through a 1 year sampling of recycle streams and the implementation of nutrient recovery. Time series analyses showed that P (as orthophosphate) concentration was time-variant in digester effluent streams, while N (as ammonia) concentration was time-variant in only the aerobic system. Furthermore, these two nutrient concentrations did not correlate in any of the recycle streams. Subsequent multivariate screening analyses identified anode type, NH 4 + concentration, cathodic potential, P concentration, and temperature as most significant for ENR. Finally, the optimum conditions of cathodic potential, anode area-to-volume ratio, and temperature applied to a real recycle stream resulted in 95% P recovery with 0.03 kWh/kg P. This energy consumption is significantly lower than process energy for conventional P fertilizers (1.1 kWh/kg P) and chemical recovery processes at scale (1.7–12.9 kWh/kg P). Overall, this study recommended specific process controls for nutrient recovery, expanded the variables evaluated for ENR, and demonstrated the ability to significantly impact energy demand associated with P-based fertilizers.

36 MATERIALS SCIENCE↗

Energy Demand Management in Buildings Using PCM-Integrated Wall

The buildings in the United States annually consume nearly 40% of total U.S. energy consumption and approximately 75% of U.S. electricity consumption. Almost half of the total U.S. energy consumption in buildings is attributed to the space conditioning through Heating, Ventilation, and Air Conditioning (HVAC) systems. Utilizing thermal energy storage in buildings, particularly integrating phase change material (PCM) in the walls, has been reported to be an effective method of managing the space heating and cooling loads. This presentation covers an in-depth discussion on the integration of a PCM to building walls, the key conditions required for effective utilization of the PCM, and effect of the PCM transition temperature and the PCM location on energy-saving potential of the PCM-integrated wall.

building↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supply Chain Energy and Greenhouse Gas Analysis Using the Materials Flows Through Industry (MFI) Tool: Examination of Alternative Technology Scenarios for the U.S. Chemical Sector

Chemical manufacturing is a large and diverse sector of the U.S. economy, with products, fuels, and a wide assortment of materials used daily by both the public and businesses. Currently, several of the largest volume chemicals produced in the United States rely on fossil fuels as a feedstock, energy source, or both. The list of chemicals includes steam cracking products such as ethylene, propylene, benzene, and xylenes as well as products such as ammonia and methanol. The focus for this work is on platform chemicals that are both produced in the largest volume and have a high potential for subsequent processing into more specialized products. In this study, we explore several new pathways that reduce the overall energy consumption and greenhouse gas (GHG) emissions for each product. These pathways include energy efficiency measures applied to existing production methods, the use of bio‐based fuels and/or feedstocks as new production methods, and electrification of high‐energy‐input stages within current production methods. Scenarios for energy demand and GHG reduction were conducted with the National Renewable Energy Laboratory's Materials Flows through Industry tool. Projections of the energy demand and GHG emissions in 2030 and 2050 are included, using grid composition projections from the NREL ReEDS model. The alternative scenarios selected showcase the effect of realistic changes the industry could make, focusing on technologies with a high level of technical readiness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

PoolDilutionR : An R package for easy optimization of isotope pool dilution calculations

Abstract Isotopic pool dilution is a powerful approach to quantify gross biogeochemical transformation rates, but remains seldom used despite its potential. To facilitate broader implementation of pool dilution methods, we present a user‐friendly R package that optimizes gross production and consumption rates (and optionally fractionation constants as well) based on standard pool dilution time series data. This package features extensive documentation and example analyses, and is easily integrated into analytical pipelines. With this open‐source tool, the biogeochemistry community will be able to readily apply isotope pool dilution to a wide range of processes.

59 BASIC BIOLOGICAL SCIENCES↗

Editors’ Choice—Molten Salt Electrolysis in Chloride Melts for Energy-Efficient Iron Metal Production

This study explores chloride molten salt electrolysis (CMSE) as a promising route for energy-efficient iron metal (Fe) production. Moderate temperature (500 °C) LiCl-KCl molten salts offer excellent thermodynamic stability, high ionic conductivity and diffusivity, and high solubility for FeCl 3 , thereby enabling efficient Fe metal extraction at high electrowinning rates. Here, we demonstrate the two essential steps for converting taconite ore into Fe metal. First, Fe 2 O 3 from taconite pellets was selectively leached in HCl yielding a high-purity FeCl 3 aqueous solution, while the gangue components settled at the bottom. Then, anhydrous FeCl 3 was electrolyzed in a LiCl-KCl eutectic molten salt at 500 °C at high current density (1 A cm −2 ) and at high Coulombic efficiency (>85%). Analysis of the electrowon Fe deposits revealed dendritic structures with purity of >99 wt%, which could be further improved to nearly 100 wt% through arc re-melting. CMSE offers low specific energy consumption (3.7 kWhr kg −1 ), competitive with H 2 -DRI and other electrolytic approaches being pursued globally. Our findings underscore the potential of CMSE as an energy-efficient route for electrosynthesis of Fe metal.

36 MATERIALS SCIENCE↗

EV Shuttle Bus Pilot

The EV Shuttle Bus Pilot dataset contains data and analysis from Hocking-Athens-Perry Community Action's demonstration of an electric bus on routes of their rural Athens Public Transit system. The vehicle used in the demonstration was a Ford E-450 cutaway equipped with an electric drivetrain, a 127-kWh battery system by Motiv Power Systems, and a cabin upfit by Turtle Top. Data gathered include route assignments, running time and distance, fuel economy, and charge cycles. A comparison of the vehicle's observed duty cycle with duty cycle modeling from other rural transit fleets in the National Transit Database is included to help better understand the rural adoption potential for this fleet technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A DYNAMIC ENERGY MODEL FOR DISPLAY CASES CONSIDERING FAULTS IN SUPERMARKETS FOR LOW GWP REFRIGERANTION

Display cases are widely used in supermarkets to demonstrate commercial goods for customers, like milk, frozen food, ice-cream, etc. There are two types of display case: open case and closed case. The goods inside display cases need to stay within a stable temperature range to meet the quality standards. However, due to variety of faults (e.g., leaving door opening), it is hard to maintain a stable temperature. The associated energy consumption from display cases is extremely high due to faults. There is a need for a dynamic energy model to accurately predict the good temperature and energy consumption under faults. A dynamic model is developed based on operation data collected through field tests in a low global warming potential (GWP) refrigeration system, at Oak Ridge National Laboratory.

Li, Yanfei↗

A Collaborative Industrial Assessment Center (IAC) for Expanded Outreach within the Southeast

This GA-FL IAC had impacts on workforce development and economic impact for regional small- and medium-sized enterprises. Qualified faculty and campus staff educated and trained cohorts of students regarding state-of-the-art industrial assessments. Students gained hands-on experiences in learning about manufacturing processes, energy systems, developing assessment recommendations/calculations, and client interaction. These skills were complemented by the incorporation of IAC themes into some course curricula. As far as economic impact, the center conducted 66 assessments over 5 years primarily in Georgia and Florida. These represented hundreds of thousands of dollars in potential annual resource savings to the clients and region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Key Grid-Interactive Efficient Building Technologies for Federal and Commercial Facilities

This report serves as a resource for building owners and managers interested in deploying GEB technologies in federal and commercial facilities. This document also provides an overview of smart buildings and the prioritization and categorization of GEB technologies that have a high potential to provide grid services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resolving dynamic mineral-organic interactions in the rhizosphere by combining in-situ microsensors with plant-soil reactive transport modeling

Associations between minerals and organic matter represent one of the most important carbon storage mechanisms in soils. Plant roots are major sources of soil carbon, and resolving the dynamics and dominance of microbial consumption versus mineral sorption of root-derived carbon is critical to understanding soil carbon storage. Here we integrate in-situ rhizosphere microsensor and plant physiological measurements with a 3-D plant-soil reactive transport model to explore the fate of dissolved organic carbon (DOC) in the rhizosphere, particularly its microbial consumption and interaction with Fe oxide minerals. Over several days, a microdialysis probe sampling pore water at the root-soil interface of growing Vicia faba roots in live soil, revealed clear diel patterns of DOC concentration. Daytime DOC spikes coincided with peaks in leaf-level photosynthesis rates and were accompanied by declining redox potential and dissolved oxygen as well as increasing pH in the rhizosphere. Incorporating microsensor data into our modeling framework showed that the measured rapid loss of DOC after each mid-day spike could not be explained by consumption via aerobic respiration, nor via anaerobic respiration dominated by Fe oxide reduction. Rather, in the model, a large fraction of rhizosphere DOC was rapidly immobilized each day by adsorption to Fe oxides. Further, modeled microbial Fe reduction (fueled by DOC) did not mobilize significant organic carbon from Fe oxides during the day. Instead, the model predicted equilibrium desorption of organic carbon from Fe oxides at night. This new mechanistic modeling framework, which couples aboveground plant physiological measurements with non-destructive high-resolution monitoring of rhizosphere processes, has great potential for exploring the dynamics and balance of the various microbial reactions and mineral interactions controlling carbon transformations and storage in soils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal conditions for efficient flow-electrode capacitive deionization

One of the current barriers to achieving fast and stable performance for flow-electrode capacitive deionization (FCDI) is determining optimal operating parameters. To date, however, no consensus has been reached for universal conditions for FCDI. Through experimental and modeling approaches in this study, we systematically evaluated the influence of applied potential (V = 1.2–2.4 V) and electrolyte concentration (C0 = 0.05–0.5 M) on the FCDI and electrodialysis (ED) desalination processes. Evaluation indicators include the concentration decrease in the desalinated solution, salt removal rates, pH fluctuations, charge efficiency, and energy consumption. Results demonstrated that the dynamic curves of concentration decrease at 2.0 V nearly overlapped with the response at 1.6 V at certain electrolyte concentrations, while the salt removal rates at 0.2 M salt concentration were the best among all concentrations tested at a range of applied potential. Therefore, it was thus concluded that the optimum conditions for FCDI operation are 1.6 V applied potential and 0.2 M initial salt concentration, under which faradaic reactions are not being triggered, and concentration polarization does not significantly affect ion transfer. Furthermore, a comparative study between FCDI and ED indicated that ED has a different dependence on the electrolyte concentration and applied potential, in which the desalination can be linearly enhanced with increasing potential but greatly limited at high concentrations. Due to the presence of carbon particles in FCDI, the enhanced charge/ion transfer is probably the main reason for the different desalination performance of FCDI and ED. Overall, the optimal operating parameters obtained in this work could be used as basic test conditions for further development of new carbon-based materials for FCDI.

42 ENGINEERING↗

Performance and power modeling and prediction using MuMMI and 10 machine learning methods

Energy-efficient scientific applications require insight into how high performance computing system features impact the applications' power and performance. This insight can result from the development of performance and power models. Here, in this article, we use the modeling and prediction tool MuMMI (Multiple Metrics Modeling Infrastructure) and 10 machine learning methods to model and predict performance and power consumption and compare their prediction error rates. We use an algorithm-based fault-tolerant linear algebra code and a multilevel checkpointing fault-tolerant heat distribution code to conduct our modeling and prediction study on the Cray XC40 Theta and IBM BG/Q Mira at Argonne National Laboratory and the Intel Haswell cluster Shepard at Sandia National Laboratories. Our experimental results show that the prediction error rates in performance and power using MuMMI are less than 10% for most cases. By utilizing the models for runtime, node power, CPU power, and memory power, we identify the most significant performance counters for potential application optimizations, and we predict theoretical outcomes of the optimizations. Based on two collected datasets, we analyze and compare the prediction accuracy in performance and power consumption using MuMMI and 10 machine learning methods.

97 MATHEMATICS AND COMPUTING↗

High Temperature, High Pressure Stability of Aqueous Foams for Potential Application in Enhanced Geothermal System (EGS)

Enhanced Geothermal Systems (EGS) are typically constructed by injecting high-pressure water into deep hot dry rocks (HDR) under carefully controlled conditions to create new or re-open existing fractures, which usually uses an immense quantity of water. In lieu, a more sustainable technique is to utilize aqueous foams as fracturing fluid to reduce water consumption and waste-water treatments of conventional hydraulic fracturing. Although foam-based fracturing has shown promising results in oil and gas industries, its feasibility is not demonstrated in EGS conditions that usually involve high temperature and high pressures. One potential barrier of utilizing foams in EGS applications is that foams are thermodynamically unstable and will become more unstable with increasing temperature due to liquid drainage, bubble coarsening, and coalescence. This work focuses on evaluation of the stability of selected aqueous foams under high-temperature and high-pressure conditions. Specifically, foams generated with surfactant alfa olefin sulfonate (AOS) were studied at temperature up to 200oC, while the pressure ranged between 100 psi and 1000 psi. The effect of additional stabilizing agents was also examined, including guar gum, bentonite clay, borate salt crosslinker, silicon dioxide nanoparticles (SiO2), and graphene oxide (GO) dispersion. Results showed that the stabilizing agents can enhance the foam thermal stability. Foams made with AOS and the borate salt crosslinker exhibited the longest half-life of 20 min at 200°C when the pressure was at 1000 psi. Data fitting showed that foam stability decreased exponentially as temperature increased. On the other hand, pressure increased the foam half-life which followed a power model. This study indicates that it may be possible to obtain highly stable foams at high-temperature and high-pressure conditions with appropriate stabilizing agents.

Thakore, Viren↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗