Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Condensate fraction of cold gases in a nonuniform external potential

Exact calculation of the condensate fraction in multidimensional inhomogeneous interacting Bose systems in a confining potential of arbitrary shape is a difficult computational problem. We have developed an iterative procedure which allows us to calculate the condensate fraction as well as the corresponding eigenfunction of the one-body density matrix. We successfully validate this procedure in diffusion Monte Carlo simulations of a Bose gas in an optical lattice at zero temperature. We also discuss the relation between different criteria used for testing coherence in cold Bose systems, such as the fraction of particles that are superfluid, condensed, or in the zero-momentum state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stable explicit coupling of the Yee scheme with a linear current model in fluctuating magnetized plasmas

This work analyzes the stability of the Yee scheme for non-stationary Maxwell's equations coupled with a linear current model with density fluctuations. We show that the usual procedure may yield unstable scheme for physical situations that correspond to strongly magnetized plasmas in X-mode (TE) polarization. We propose to use first order clustered discretization of the vectorial product that gives back a stable coupling. We validate the schemes on some test cases representative of direct numerical simulations of X-mode in a magnetic fusion plasma including turbulence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibrated cylindrical Mach probe in a plasma wind tunnel

A simple cylindrical Mach probe is described along with an independent calibration procedure in a magnetized plasma wind tunnel. A particle orbit calculation corroborates our model. The probe operates in the weakly magnetized regime in which probe dimension and ion orbit are of the same scale. Analytical and simulation models are favorably compared with experimental calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computing the Casimir energy using the point-matching method

We use a point-matching approach to numerically compute the Casimir interaction energy for a two perfect-conductor waveguide of arbitrary section. We present the method and describe the procedure used to obtain the numerical results. At first, our technique is tested for geometries with known solutions, such as concentric and eccentric cylinders. Then, we apply the point-matching technique to compute the Casimir interaction energy for new geometries such as concentric corrugated cylinders and cylinders inside conductors with focal lines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Derivative expansion for the boundary interaction terms in the Casimir effect: Generalized {delta} potentials

We calculate the Casimir energy for scalar fields in interaction with finite-width mirrors, described by nonlocal interaction terms. These terms, which include quantum effects due to the matter fields inside the mirrors, are approximated by means of a local expansion procedure. As a result of this expansion, an effective theory for the vacuum field emerges, which can be written in terms of generalized {delta} potentials. We compute explicitly the Casimir energy for these potentials and show that, for some particular cases, it is possible to reinterpret them as imposing imperfect Dirichlet boundary conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-C-19A-01: Analytic Design Method to Make a 2D Planar, Segmented Ion Chamber Water-Equivalent for Proton Dose Measurements

Purpose: Quality Assurance (QA) measurements of proton therapy fields must accurately measure steep longitudinal dose gradients as well as characterize the dose distribution laterally. Currently, available devices for two-dimensional field measurements perturb the dose distribution such that routine QA measurements performed at multiple depths require multiple field deliveries and are time consuming. Methods: A design procedure for a two-dimensional detector array is introduced whereby the proton energy loss and scatter are adjusted so that the downstream dose distribution is maintained to be equivalent to that which would occur in uniform water. Starting with the design for an existing, functional two-dimensional segmented ion chamber prototype, a compensating material is introduced downstream of the detector to simultaneously equate the energy loss and lateral scatter in the detector assembly to the values in water. An analytic formalism and procedure is demonstrated to calculate the properties of the compensating material in the general case of multiple layers of arbitrary material. The resulting design is validated with Monte Carlo simulations. Results: With respect to the specific prototype design considered, the results indicate that a graphite compensating layer of the proper dimensions can yield proton beam range perturbation less than 0.1mm and beam sigma perturbation less than 2% across the energy range of therapeutic proton beams. Conclusion: We have shown that, for a 2D gas-filled detector array, a graphite-compensating layer can balance the energy loss and multiple Coulomb scattering relative to uniform water. We have demonstrated an analytic formalism and procedure to determine a compensating material in the general case of multiple layers of arbitrary material. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17-W81XWH-04-2-0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.

07 ISOTOPE AND RADIATION SOURCES↗

CFD Model Development and validation for High Temperature Gas Cooled Reactor Cavity Cooling System (RCCS) Applications

The Reactor Cavity Cooling Systems (RCCS) is a passive safety system that will be incorporated in the VTHR design. The system was designed to remove the heat from the reactor cavity and maintain the temperature of structures and concrete walls under desired limits during normal operation (steady-state) and accident scenarios. A small scale (1:23) water-cooled experimental facility was scaled, designed, and constructed in order to study the complex thermohydraulic phenomena taking place in the RCCS during steady-state and transient conditions. The facility represents a portion of the reactor vessel with nine stainless steel coolant risers and utilizes water as coolant. The facility was equipped with instrumentation to measure temperatures and flow rates and a general verification was completed during the shakedown. A model of the experimental facility was prepared using RELAP5-3D and simulations were performed to validate the scaling procedure. The experimental data produced during the steady-state run were compared with the simulation results obtained using RELAP5-3D. The overall behavior of the facility met the expectations. The facility capabilities were confirmed to be very promising in performing additional experimental tests, including flow visualization, and produce data for code validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupling of the model reduction technique with the lattice Boltzmann method for combustion simulations

A new framework of simulation of reactive flows is proposed based on a coupling between accurate reduced reaction mechanism and the lattice Boltzmann representation of the flow phenomena. The model reduction is developed in the setting of slow invariant manifold construction, and the simplest lattice Boltzmann equation is used in order to work out the procedure of coupling of the reduced model with the flow solver. Practical details of constructing slow invariant manifolds of a reaction system under various thermodynamic conditions are reported. The proposed method is validated with the two-dimensional simulation of a premixed counterflow flame in the hydrogen-air mixture. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel adaptive time stepping variant of the Boris–Buneman integrator for the simulation of particle accelerators with space charge

We show that adaptive time stepping in particle accelerator simulation is an enhancement for certain problems. The new algorithm has been implemented in the OPAL (Object Oriented Parallel Accelerator Library) framework. The idea is to adjust the frequency of costly self-field calculations, which are needed to model Coulomb interaction (space charge) effects. In analogy to a Kepler orbit simulation that requires a higher time step resolution at the close encounter, we propose to choose the time step based on the magnitude of the space charge forces. Inspired by geometric integration techniques, our algorithm chooses the time step proportional to a function of the current phase space state instead of calculating a local error estimate like a conventional adaptive procedure. Building on recent work, a more profound argument is given on how exactly the time step should be chosen. An intermediate algorithm, initially built to allow a clearer analysis by introducing separate time steps for external field and self-field integration, turned out to be useful by its own, for a large class of problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Modality Phantom Development

Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agargelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-188: Clinical Implementation of in Room Mobile CT for Image Guided Proton Therapy

Purpose: To implement soft-tissue image-guided proton therapy using inroom mobile CT. Methods: Anthropomorphic phantom was first used to determine the setup accuracy using in- room mobile CT. Laser and bbs were used for the initial setup (marked isocenter). CT data was then acquired with in-room mobile CT (daily CT). The shift between the marked isocenter and the planned isocenter (final isocenter) was determined from the daily CT using in-house Computer Assisted Targeting (CAT) software. Orthogonal DRRs of the day was also generated from the daily CT. The phantom was then transferred on the treatment couch top to the treatment machine using a transportation system, and again aligned to the marked isocenter. Couch shifts were made to align the phantom to the final isocenter using the shifts as determined using the CAT software, and verified using orthogonal X-ray images with the daily DRRs. Results: Phantom data suggests that following the setup procedure as described above, targeting accuracy could be within 1 mm. Patient data are being acquired and analyzed. Conclusion: In-room mobile CT is capable of providing soft-tissue image-guided proton therapy.

60 APPLIED LIFE SCIENCES↗

An Advanced ISOCS In Situ Gamma Spectrometry Services Tool to Reduce Uncertainties in Waste Characterization Projects - 16311

Canberra's In Situ Object Counting System (ISOCS) is an established tool used for gamma spectrometry allowing a physical representation of complex geometries and mathematical calculation of the calibration function. It avoids the need for radioisotope standards which can be costly and prohibitively difficult to produce. Uncertainties in the sample - detector geometry lead to uncertainties in the calibrations. Canberra's ISOCS Uncertainty Estimator (IUE) tool offers an automated means of accommodating known model geometry uncertainties, with calculation of robust defensible calibration uncertainties. However these uncertainties may be large leading to potential over-estimation of under-estimation of activity. This can be equated directly to waste disposal costs if one is using ISOCS for waste sentencing to classify wastes as (for example) Transuranic Waste (TRU) or Low Level Waste (LLW). An Advanced ISOCS in-situ Gamma Spectrometry (AIGS) services tool has been developed to reduce the uncertainties. This system is based on generating and comparing geometry models that yield Figures of Merit (FoM) indicative of improved consistency between modelled data and available diverse measurement data. This paper describes the development and features of AIGS, focusing on recent testing with radioisotope sources in a 200 litre drum filled with a simulated waste matrix. The results demonstrate a significant advantage for Am-241 where uncertainties can otherwise amount to a factor of 2 or more. We show how our specialist teams can develop procedures for deployment of standard ISOCS hardware, adapting measurement geometries and procedures through careful planning, to provide data that can be used to greatly reduce the uncertainties in the measured activities. Lastly, we comment on the range of potential applications for this new technique and the wider benefits for the decommissioning industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Irreversible Electroporation for Unresectable Hepatocellular Carcinoma: Initial Experience

Purpose: To evaluate the efficacy and safety of irreversible electroporation (IRE) in the treatment of unresectable hepatocellular carcinoma (HCC). Materials and Methods: A retrospective study was conducted from September 2014 to June 2017. A total of 21 HCCs in 21 patients with cirrhosis were treated with IRE. There were eight subcapsular or exophytic, ten perivascular and three peribiliary tumors. The median tumor size was 26 mm (range 14–40 mm). The technical success of the procedure was recorded. Median follow-up, median time to local recurrence, median local tumor progression-free survival (PFS) and complications were recorded. Results: Technical success was achieved in all the patients. The median follow-up was 10 months (range 2–30 months). The median time to local recurrence and local tumor PFS were 4 months (range 3–4 months) and 7 months (range 3–30 months), respectively. The tumor-related factor that was significantly associated with local PFS was the size. Maximum tumor diameter < 25 mm was significantly associated with local tumor PFS (p = 0.045). Other parameters including tumor location, segmental portal vein thrombosis, baseline alpha-fetoprotein level and underlying etiology did not affect local tumor PFS. Complications were noted in nine patients and were classified as grades 1 and 2. No procedure-related mortality was encountered. Conclusion: IRE is an effective treatment for ablation of small HCCs. Larger prospective studies with strict selection criteria will establish the safety and efficacy of IRE in the treatment of unresectable HCC in patients who cannot undergo thermal ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RF-driven advanced modes of ITER operation

The impact of the Radio Frequency heating and current drive systems on the ITER advanced scenarios is analyzed by means of the CRONOS suite of codes for integrated tokamak modelling. As a first step, the code is applied to analyze a high power advanced scenario discharge of JET in order to validate both the heating and current drive modules and the overall simulation procedure. Then, ITER advanced scenarios, based on Radio Frequency systems, are studied on the basis of previous results. These simulations show that both hybrid and steady-state scenarios could be possible within the ITER specifications, using RF heating and current drive only.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the implementation of computed laminography using synchrotron radiation

Hard x rays from a synchrotron source are used in this implementation of computed laminography for three-dimensional (3D) imaging of flat, laterally extended objects. Due to outstanding properties of synchrotron light, high spatial resolution down to the micrometer scale can be attained, even for specimens having lateral dimensions of several decimeters. Operating either with a monochromatic or with a white synchrotron beam, the method can be optimized to attain high sensitivity or considerable inspection throughput in synchrotron user and small-batch industrial experiments. The article describes the details of experimental setups, alignment procedures, and the underlying reconstruction principles. Imaging of interconnections in flip-chip and wire-bonded devices illustrates the peculiarities of the method compared to its alternatives and demonstrates the wide application potential for the 3D inspection and quality assessment in microsystem technology.

43 PARTICLE ACCELERATORS↗