Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Inside marginal adaptation of crowns by X-ray micro-computed tomography

The objective of this work was to access dental arcade by using X-ray micro-computed tomography. For this purpose high resolution system was used and three groups were studied: Zirkonzahn CAD-CAM system, IPS e.max Press, and metal ceramic. The three systems assessed in this study showed results of marginal and discrepancy gaps clinically accepted. The great result of 2D and 3D evaluations showed that the used technique is a powerful method to investigate quantitative characteristics of dental arcade. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase distribution in Fischer-Tropsch mimicked slurry bubble column via computed tomography

This study aims to investigate the phases distribution and hydrodynamics in an air-Therminol LT-glass beads slurry bubble column reactor in bubbly and churn-turbulent flow regimes by implementing a gamma-ray computed tomography. It is found that gas holdup increases with increasing superficial gas velocity and operating pressure while increasing solids loading has an opposite effect on gas holdup measurements. It is noticed that the pressure effect is more significant at high solids loading and the solids loading is relatively more substantial at lower pressure. Solids loading has the most significant a stronger effect on the solids holdup profile than on the gas holdup profile. Current results were compared with the Sedimentation-Dispersion Model (SDM) predictions. Overall, the findings of this study advance the knowledge of the true behavior of phases distribution in FT mimicked slurry bubble columns which are pertinent in designing such reactors.

42 ENGINEERING↗

SU-G-IeP4-04: DD-Neutron Source Collimation for Neutron Stimulated Emission Computed Tomography: A Monte Carlo Simulation Study

Purpose: To optimize collimation and shielding for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact clinical neutron imaging system. The envisioned application is cancer diagnosis through Neutron Stimulated Emission Computed Tomography (NSECT). Methods: Collimator designs were tested with an isotropic 2.5 MeV neutron source through GEANT4 simulations. The collimator is a 52×52×52 cm{sup 3} polyethylene block coupled with a 1 cm lead sheet in sequence. Composite opening was modeled into the collimator to permit passage of neutrons. The opening varied in shape (cylindrical vs. tapered), size (1–5 cm source-side and target-side openings) and aperture placements (13–39 cm from source-side). Spatial and energy distribution of neutrons and gammas were tracked from each collimator design. Parameters analyzed were primary beam width (FWHM), divergence, and efficiency (percent transmission) for different configurations of the collimator. Select resultant outputs were then used for simulated NSECT imaging of a virtual breast phantom containing a 2.5 cm diameter tumor to assess the effect of the collimator on spatial resolution, noise, and scan time. Finally, composite shielding enclosure made of polyethylene and lead was designed and evaluated to block 99.99% of neutron and gamma radiation generated in the system. Results: Analysis of primary beam indicated the beam-width is linear to the aperture size. Increasing source-side opening allowed at least 20% more neutron throughput for all designs relative to the cylindrical openings. Maximum throughput for all designs was 364% relative to cylindrical openings. Conclusion: The work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-defined collimated neutron beam that can be used to image samples of interest with millimeter resolution. Balance in output efficiency, noise reduction, and scan time should be considered to determine the optimal design for specific NSECT applications.

60 APPLIED LIFE SCIENCES↗

Cone Beam Computed Tomography: The Challenges and Strategies in Its Application for Dose Accumulation

Online image guidance using cone beam computed tomography (CBCT) has greatly improved the geometric precision of radiotherapy. Changes in anatomy are common during a course of fractionated treatment, resulting in dose deviation from the planned distribution. There is increased interest in performing dose accumulation to compute the actual delivered dose and to adapt the treatment when necessary. This can be achieved by delineating the volume of interest and by generating “dose of the day” through dose computation on the CBCT. However, the image quality and the accuracy of the CT number of CBCT are deemed to be inferior to fan beam CT, which increases the uncertainty associated in this process. A review of literature was conducted to assess the reliability of and to examine strategies for overcoming the challenges in using CBCT for volume delineation and dose computation. The review demonstrates that the uncertainty varies across body sites, and different strategies have been recommended to generate comparable results to images from CT simulators. This facilitates a better understanding of the potential and the limitation of using CBCT for dose accumulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impacts of Biomass Feedstock Pre-Processing on Heat and Mass Transfer During Pyrolysis Using X-Ray Computed Tomography and Multiscale Modeling

Knowledge of the transport properties of biomass particles such as porosity, tortuosity, and permeability is paramount for high-fidelity modeling of biomass pyrolysis due to the heat and mass transfer limitations imposed by particle microstructure. X-ray computed tomography (XCT) is a non-destructive imaging method that enables full 3D reconstructions of the biomass particle microstructure with high resolution, permitting direct calculation of porosity, tortuosity, and permeability from real particle geometries. In this study, XCT imaging revealed the 3D microstructures of particles and chars from pyrolytic conversion of cylindrically cut or milled/pelletized loblolly pine samples. The porosity, tortuosity, and permeability were calculated directly from the XCT geometries via open-source microstructural analysis tool MATBOX+TauFactor (https://github.com/NREL/MATBOX_Microstructure_analysis_toolbox) and computational fluid dynamics (CFD) simulations using our solver, Mesoflow (https://github.com/NREL/mesoflow). These properties were used in a reactor scale model developed in COMSOL of the single particle reactor at NREL to investigate the impact of feedstock pre-processing on biomass conversion during pyrolysis with rigorous experimental validation.

biomass↗

Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median procedural times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling Pancreatic Tumor Motion Using 4-Dimensional Computed Tomography and Surrogate Markers

Purpose: To assess intrafractional positional variations of pancreatic tumors using 4-dimensional computed tomography (4D-CT), their impact on gross tumor volume (GTV) coverage, the reliability of biliary stent, fiducial seeds, and the real-time position management (RPM) external marker as tumor surrogates for setup of respiratory gated treatment, and to build a correlative model of tumor motion. Methods and Materials: We analyzed the respiration-correlated 4D-CT images acquired during simulation of 36 patients with either a biliary stent (n=16) or implanted fiducials (n=20) who were treated with RPM respiratory gated intensity modulated radiation therapy for locally advanced pancreatic cancer. Respiratory displacement relative to end-exhalation was measured for the GTV, the biliary stent, or fiducial seeds, and the RPM marker. The results were compared between the full respiratory cycle and the gating interval. Linear mixed model was used to assess the correlation of GTV motion with the potential surrogate markers. Results: The average ± SD GTV excursions were 0.3 ± 0.2 cm in the left-right direction, 0.6 ± 0.3 cm in the anterior-posterior direction, and 1.3 ± 0.7 cm in the superior-inferior direction. Gating around end-exhalation reduced GTV motion by 46% to 60%. D95% was at least the prescribed 56 Gy in 76% of patients. GTV displacement was associated with the RPM marker, the biliary stent, and the fiducial seeds. The correlation was better with fiducial seeds and with biliary stent. Conclusions: Respiratory gating reduced the margin necessary for radiation therapy for pancreatic tumors. GTV motion was well correlated with biliary stent or fiducial seed displacements, validating their use as surrogates for daily assessment of GTV position during treatment. A patient-specific internal target volume based on 4D-CT is recommended both for gated and not-gated treatment; otherwise, our model can be used to predict the degree of GTV motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcomes of Computed Tomography–Based Volumetric Brachytherapy Planning for Cervical Cancer

Purpose/Objectives: A report of clinical outcomes of a computed tomography (CT)-based image guided brachytherapy (IGBT) technique for treatment of cervical cancer. Methods and Materials: Seventy-six women with International Federation of Gynecology and Obstetrics stage IB to IVA cervical carcinoma diagnosed between 2007 and 2014 were treated with definitive external beam radiation therapy (EBRT) with or without concurrent chemotherapy followed by high-dose-rate (HDR) IGBT. All patients underwent planning CT simulation at each implantation. A high-risk clinical target volume (HRCTV) encompassing any visible tumor and the entire cervix was contoured on the simulation CT. When available, magnetic resonance imaging (MRI) was performed at implantation to assist with tumor delineation. The prescription dose was prescribed to the HRCTV. Results: The median follow-up time was 17 months. Thirteen patients (17%) had an MRI done before brachytherapy, and 16 patients (21%) were treated without MRI guidance. The mean EBRT/IGBT sum 2-Gy equivalent dose (EQD2) delivered to the 90% volume of the HRCTV was 86.3 Gy. The mean maximum EQD2s delivered to 2 cm{sup 3} of the rectum, sigmoid, and bladder were 67.5 Gy, 66.2 Gy, and 75.3 Gy, respectively. The 2-year cumulative incidences of local, locoregional, and distant failure were 5.8% (95% confidence interval [CI]: 1.4%-14.8%), 15.1% (95% CI: 5.4%-29.4%), and 24.3% (95% CI: 12.1%-38.9%), respectively. The 2-year overall and disease-free survival rates were 75% (95% CI, 61%-91%) and 73% (95% CI, 60%-90%), respectively. Twenty-nine patients (38%) experienced grade ≥2 acute toxicity, with 5 cases of acute grade 3 toxicity and no grade ≥4 toxicities. One patient experienced grade 3 gastrointestinal toxicity. No other late grade ≥3 events were observed. Conclusions: This is the largest report to date of CT/MRI-based IGBT for the treatment of cervical cancer. The results are promising, with excellent local control and acceptable toxicity. Further investigation is needed to assess the long-term safety and efficacy of this treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Informing Patients About the Cancer Induction Risk of Undergoing Computed Tomography Imaging: The Radiographers' Perspective

In the midst of debates about the actual risk posed from computed tomography (CT) imaging, there is a general consensus that patients have a right to information. Despite this, communication of the potential cancer induction risk from CT scans is poor, leading to poor patient awareness. Without adequate awareness of any significant risks patients might be deprived of the opportunity to take part in their own care and, therefore, the opportunity for patient-centered care is missed. The aims of this study were to determine whether CT radiographers provide patients with information about cancer induction risks from CT scans and the rationale for their practices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments

By means of fluorescent x-ray computed tomography (FXCT) one can detect and image a distribution of non-radioactive imaging agent, e.g., iodine, in a biomedical subject at a high spatial resolution, so it can be a novel molecular imaging modality. We have been studying an FXCT system using synchrotron radiation for in-vivo imaging brains of small animals such as mouse, or rat. For the purpose, we propose a fast FXCT imaging method based on the novel geometry. In this study, we prove the feasibility of this concept and investigate its imaging properties, including spatial and contrast resolutions and quantitativeness, by imaging an acrylic phantom and a normal mouse brain using a preliminary imaging system with monochromatic synchrotron x rays.

60 APPLIED LIFE SCIENCES↗

Image-based iterative compensation of motion artifacts in computed tomography

Purpose: This article presents an iterative method for compensation of motion artifacts for slowly rotating computed tomography (CT) systems. Patient's motion introduces inconsistencies among projections and yields severe reconstruction artifacts for free-breathing acquisitions. Streaks and doubling of structures can appear and the resolution is limited by strong blurring. Methods: The rationale of the proposed motion compensation method is to iteratively correct the reconstructed image by first decomposing the perceived motion in projection space, then reconstructing the motion artifacts in image space, and finally subtracting the artifacts from an initial image. The initial image is reconstructed from the acquired data and might contain motion blur artifacts but, nevertheless, is considered as a reference for estimating the reconstruction artifacts. Results: Qualitative and quantitative figures are shown for experiments based on numerically simulated projections of a sequence of clinical images resulting from a respiratory-gated helical CT acquisition. The border of the diaphragm becomes progressively sharper and the contrast improves for small structures in the lungs. Conclusions: The originality of the technique stems from the fact that the patient motion is not explicitly estimated but the motion artifacts are reconstructed in image space. This approach could provide sharp static anatomical images on interventional C-arm systems or on slowly rotating X-ray equipments in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 08: Rotational errors with on-board cone beam computed tomography

The focus of this study is on the Elekta XVI on-board cone beam computed tomography (CBCT) system. A rotational mismatch as large as 0.5° is observed between clockwise (CW) and counter-clockwise (CCW) CBCT scans. The error could affect non-isocentric treatments (e.g., lung SBRT and acoustic neuroma), as well as off-axis organs-at-risk. The error is caused by mislabeling of the projections with a lagging gantry angle, which is caused by the finite image acquisition time and delays in the imaging system. A 30 cm diameter cylindrical phantom with 5 mm diameter holes is used for the scanning. CW and CCW scans are acquired for five gantry speeds (360 to 120 deg./min.) on six linacs from three generations (MLCi, MLCi2, and Agility). Additional scans are acquired with different x-ray pulse widths for the same mAs. In the automated CBCT analysis (using ImageJ), the CW/CCW mismatch in a series of line profiles is identified and used to calculate the rotational error. Results are consistent among all linacs and indicate that the error varies linearly with gantry speed. The finite width of the x-ray pulses is a major but predictable contributor to the delay causing the error. For 40 ms pulses, the delay is 34 ± 1 ms. A simple solution applied in our clinic is adjusting the gantry angle offset to make the CCW one-minute scans correct. A more involved approach we are currently investigating includes adjustments of pulse width and mA, resulting in focal spot changes, with potential impact on image quality.

60 APPLIED LIFE SCIENCES↗

Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Marcellus Formation from the Whipkey ST 1 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) Morgantown, West Virginia site were used to characterize core of the Marcellus Formation from a vertical well drilled in Greene County, Pennsylvania by the Energy Corporation of America. The core is from the Whipkey ST 1 well, in the Carmichaels Field, and is comprised primarily of the Marcellus Formation from depths of 7,719 to 7,910.8 ft. Core was provided by Tim Carr and Keithan Martin (West Virginia University and ORISE). The primary impetus of this work is a collaboration between West Virginia University (WVU) and NETL to characterize core from multiple wells to better understand the structure and variation of the Marcellus and Utica Shale Formations. As part of this effort, bulk scans of core were obtained from the Whipkey ST 1 well. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis. The resultant datasets are presented in this report, and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/whipkey-well. All equipment and techniques used were non-destructive, enabling future examinations to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of Core from the Marcellus Shale Energy and Environment Laboratory

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize middle Devonian black shale from the Marcellus Shale Energy and Environmental Laboratory (MSEEL) site in northeastern West Virginia. The samples are representative of the Middle Devonian Marcellus Formation, a clay-rich black shale in the Appalachian Basin. The MSEEL site is a unique field study area for new techniques supporting natural gas production and a high level of monitoring of environmental impacts. The primary impetus of this work is a collaboration between NETL, West Virginia University, Northeast Natural Energy (NNE), and Ohio State University to characterize core from multiple wells to better understand the structure and variation of the Marcellus Shale formations. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Smackover Formation from the Roberson 18-19 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize the Upper Jurassic (Oxfordian) Smackover limestone in the Roberson 18-19 1-15H core retrieved from the Atlanta Field, Columbia County, Arkansas. The 365.68-ft long Roberson core came from a vertical well at depths 8,802 ft to 9,169.60 ft, drilled by Southwestern Energy targeting the Smackover Formation as a potential unconventional oil reservoir. The primary impetus of this work was to non-destructively characterize core from the Smackover Formation that was acquired through a core exchange with Southwestern Energy. The Smackover Formation is an unconventional limestone play in southern Arkansas. This report and the associated scans provide detailed datasets not typically made publicly available from unconventional limestone for analysis. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roberson-smackover.

58 GEOSCIENCES↗

Portable Digital Radiography and Computed Tomography Manual

This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

47 OTHER INSTRUMENTATION↗