The correlation of X-ray emission with strong millimeter activity in extragalactic sources

A sample of 25 strong extragalactic millimeter sources have been observed at about 1 keV with the Imaging Proportional Counter on the Einstein X-Ray Observatory and at 90 GHz with the NRAO 11 m telescope. A strong correlation between the millimeter and X-ray flux densities is found. This result is consistent with a synchronous self-Compton model in which the X-ray emission arises from the Compton scattering of millimeter radio photons off the relativistic electrons which created them.

Owen, F. N.↗

X-ray background, discrete sources, and diffuse processes

Possible sources are discussed for the cosmic residual X-ray background (XRB) radiation at energies from 3-50 keV. Sources have been identified that can account for at least 50 percent of the XRB. The residual has a spectrum with a flat slope up to 30 keV. Comptonized thermal gas emission is ruled out as the origin of the radiation since the emitting regions would be diffuse and Comptonization would require regions no more than a parsec across. Optically thin bremsstrahlung from discrete sources is a more viable candidate, although the associated spectra would not have been accessible with the Einstein Observatory. Future observations with the AXAF and ROSAT satellites in imaging and spectroscopic modes are discussed for gaining definitive data on the real sources of the XRB.

Giacconi, Riccardo↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

High energy spectroscopy with the AXAF

The AXAF is a meter-class telescope that is planned to be the third of NASA's Great Observatories, joining the Hubble Space Telescope and the Compton Gamma Ray Observatory in orbit before the end of this decade. The telescope will approach tenth-arc-second resolution over a dynamic range of 100 (0.1-10 keV). An assortment of gratings and focal plane detectors will be utilized to provide unprecedented imaging and spectroscopic capabilities in a long-lived facility. In particular, the AXAF is unique in its high resolution imaging, and in the hard X-ray spectroscopy that can be performed with both high resolution and high throughput.

Holt, S. S.↗

A glimpse of gluons through deeply virtual compton scattering on the proton

The proton is composed of quarks and gluons, bound by the most elusive mechanism of strong interaction called confinement. In this work, the dynamics of quarks and gluons are investigated using deeply virtual Compton scattering (DVCS): produced by a multi-GeV electron, a highly virtual photon scatters off the proton which subsequently radiates a high energy photon. Similarly to holography, measuring not only the magnitude but also the phase of the DVCS amplitude allows to perform 3D images of the internal structure of the proton. The phase is made accessible through the quantum-mechanical interference of DVCS with the Bethe-Heitler (BH) process, in which the final photon is emitted by the electron rather than the proton. Here, we report herein the first full determination of the BH-DVCS interference by exploiting the distinct energy dependences of the DVCS and BH amplitudes. In the high energy regime where the scattering process is expected to occur off a single quark in the proton, these accurate measurements show an intriguing sensitivity to gluons, the carriers of the strong interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Next Generation of MeV Energy X-ray Sources for Use in the Inspection of Additively Manufactured Parts for Industry

In September 2022, we investigated whether we can change the way we perform non-destructive characterization (NDC) of dense, micrometer-scale objects, e.g., additively manufactured (AM) parts, using the BELLA inverse Compton source (ICS). X-ray computed tomography (CT) is the most suitable technique for NDC of these objects, but often requires x-rays with MeV energy for penetration, sub-mm spatial resolution for small structures, a narrow spectrum for low-artifact images, and the ability to tune x ray energy to image a wide range of materials. The BELLA ICS has the unique potential to produce such an x-ray beam with a repetition rate high enough for CT. We scanned a geometric calibration phantom, fabricated by LLNL, a bearing, and an AM part manufactured by Renishaw. We reconstructed the first CT images of their kind. The results are very promising, and LLNL will present our findings at an SPIE conference.

42 ENGINEERING↗

Science with the Space Infrared Telescope Facility

The Space Infrared Telescope Facility (SIRTF), the fourth and final member of NASA's series of Great Observatories, is scheduled to launch on April 15,2003. Together with the Hubbie Space Telescope, the Compton Gamma ray Telescope, and the Chandra X-Ray Telescope this series of observatories offers observational capabilities across the electromagnetic spectrum from the infrared to high-energy gamma rays. SIRTF is based on three focal plane instruments - an infrared spectrograph and two infrared imagers - coupled to a superfluid-helium cooled telescope to achieve unprecedented sensitivity from 3 to 180 microns. Although SIRTF is a powerful general-purpose infrared observatory, its design was based on the capability to address four broad science themes: (1) understanding the structure and composition of the early universe, (2) understanding the nature of brown dwarfs and super-planets, (3) probing protostellar, protoplanetary, and planetary debris disk systems, and (4) understanding the origin and structure of ultraluminous infrared galaxies and active galactic nuclei. This talk will address the design and capabilities of the SIRTF observatory, provide an overview of some of the initial science investigations planned by the SIRTF Guaranteed Time Observers, and give a brief overview of the General Observer proposal process.

Roellig, Thomas L.↗

SU-G-IeP3-07: High-Resolution, High-Sensitivity Imaging and Quantification of Intratumoral Distributions of Gold Nanoparticles Using a Benchtop L-Shell XRF Imaging System

Purpose: To demonstrate the ability to perform high-resolution imaging and quantification of sparse distributions of gold nanoparticles (GNPs) within ex vivo tumor samples using a highly-sensitive benchtop L-shell x-ray fluorescence (XRF) imaging system. Methods: An optimized L-shell XRF imaging system was assembled using a tungsten-target x-ray source (operated at 62 kVp and 45 mA). The x-rays were filtered (copper: 0.08 mm & aluminum: 0.04 mm) and collimated (lead: 5 cm thickness, 3 cm aperture diameter) into a cone-beam in order to irradiate small samples or objects. A collimated (stainless steel: 4 cm thickness, 2 mm aperture diameter) silicon drift detector, capable of 2D translation, was placed at 90° with respect to the beam to acquire XRF/scatter spectra from regions of interest. Spectral processing involved extracting XRF signal from background, followed by attenuation correction using a Compton scatter-based normalization algorithm. Calibration phantoms with water/GNPs (0 and 0.00001–10 mg/cm{sup 3}) were used to determine the detection limit of the system at a 10-second acquisition time. The system was then used to map the distribution of GNPs within a 12×11×2 mm{sup 3} slice excised from the center of a GNP-loaded ex vivo murine tumor sample; a total of 110 voxels (2.65×10{sup −3} cm{sup 3}) were imaged with 1.3-mm spatial resolution. Results: The detection limit of the current cone-beam benchtop L-shell XRF system was 0.003 mg/cm{sup 3} (3 ppm). Intratumoral GNP concentrations ranging from 0.003 mg/cm{sup 3} (3 ppm) to a maximum of 0.055 mg/cm{sup 3} (55 ppm) and average of 0.0093 mg/cm{sup 3} (9.3 ppm) were imaged successfully within the ex vivo tumor slice. Conclusion: The developed cone-beam benchtop L-shell XRF imaging system can immediately be used for imaging of ex vivo tumor samples containing low concentrations of GNPs. With minor finetuning/optimization, the system can be directly adapted for performing routine preclinical in vivo imaging tasks. Supported by NIH/NCI grant R01CA155446 This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

Closed and Not Closed: Mitigating a Mystery on Chandra's Door

The Chandra X-ray Observatory is part of NASA's fleet of "Great Observatories" along with the Hubble Space Telescope, the Spitzer Space Telescope, and the now deorbited Compton Gamma Ray Observatory. The observatory was designed to detect x-ray emissions from some of the hottest regions of the galaxy including exploded stars, clusters of galaxies, and matter around black holes. One of the observatory's key scientific instruments is the Advanced CCD Imaging Spectrometer (ACIS), which is one of four primary and two focal plane instruments. Due to the sensitivity of the charged coupled devices (CCD's), an aperture door was designed and built by Lockheed-Martin that protected the instrument during testing and the time leading up to launch. The design called for a system of wax actuators (manufactured by STARSYS Corp) to be used as components in a rotary actuator that would open and close the door during ground testing and on-orbit operations. Another feature of the design was an internal shear disc located in each actuator to prevent excessive internal pressure and to shield other components from damage.

Odom, Brian↗

Characterization of a three layer Compton telescope for hadron therapy dose monitoring

A Compton telescope for dose monitoring in hadron therapy is under development at IFIC-Valencia. The system consists of three layers of LaBr{sub 3} crystals coupled to silicon photomultiplier arrays. Two- and three-layer versions of the device have been tested in the laboratory. Images of Na-22 sources have been reconstructed. In addition, the two-layer version has been tested in a proton beam. Performance improvement and full characterization of the device are ongoing. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GRIS instrument continuum results from SN1987A

Results on the continuum emission from SN1987A from two balloon flights of gamma-ray imaging spectrometer over Alice Springs, Australia, in the spring and fall of 1988 are presented. The durations of the two observations were 11.2 and 11.7 hours, respectively. The measured continuum spectra (95-2560 keV for the spring and 55-2560 keV for the fall) are consistent with Compton scattering of the Co-56 decay lines. The 10HMM model agrees well with continuum data in the energy dependence of the continuum both in the slope of the spectra and the step increases below the 2599, 1238, and 847 keV Co-56 decay lines.

Barthelmy, S.↗

Rosat observation of the 4U 1543-47 outburst in 1992

Observation of 4U 1543-47 (HL Lupi) with the Rosat satellite on 21 Aug. 1992 with the PSPC (Position Sensitive Proportional Counter) and on 4 Sep. 1992 with the HRI (High Resolution Imager), four and five months after the soft X-ray transient outburst, respectively, is reported. Both observations revealed the source to be much brighter than expected from the decay rate at harder X-rays (deduced from BATSE (Gamma Ray Burst (GRB) instrument team for the Compton Gamma Ray Observatory) data). BATSE observations in Aug. 1992 do not show any significant increase in the hard X-ray flux, suggesting that the soft and hard X-ray fluxes are either decoupled or anticorrelated to some degree.

Greiner, J.↗

HOW TO IDENTIFY AND SEPARATE BRIGHT GALAXY CLUSTERS FROM THE LOW-FREQUENCY RADIO SKY

In this work, we simulate the 50-200 MHz radio sky that is constrained in the field of view (5{sup 0} radius) of the 21 Centimeter Array (21CMA), a low-frequency radio interferometric array constructed in the remote area of Xinjiang, China, by carrying out Monte Carlo simulations to model the strong contaminating foreground of the redshifted cosmological reionization signals, including emissions from our Galaxy, galaxy clusters, and extragalactic discrete sources (i.e., star-forming galaxies, radio-quiet active galactic nuclei (AGNs), and radio-loud AGNs). As an improvement over previous works, we consider in detail not only random variations of morphological and spectroscopic parameters within the ranges allowed by multi-band observations, but also the evolution of radio halos in galaxy clusters, assuming that relativistic electrons are re-accelerated in the intracluster medium (ICM) in merger events and lose energy via both synchrotron emission and inverse Compton scattering with cosmic microwave background photons. By introducing a new approach designed on the basis of independent component analysis and wavelet detection algorithm, we prove that, with a cumulative observation of one month with the 21CMA array, about 80% of galaxy clusters (37 out of 48 clusters assuming a mean magnetic field of B = 2 {mu}G in the ICM, or 15 out of 18 clusters assuming B = 0.2 {mu}G) with central brightness temperatures of >10 K at 65 MHz can be safely identified and separated from the overwhelmingly bright foreground. By examining the brightness temperature images and spectra extracted from these identified clusters, we find that the morphological and spectroscopic distortions are extremely small compared to the input simulated clusters, and the reduced {chi}{sup 2} of brightness temperature profiles and spectra are controlled to be {approx}<0.5 and {approx}<1.3, respectively. These results robustly indicate that in the near future a sample of dozens of bright galaxy clusters will be disentangled from the foreground in 21CMA observations, the study of which will greatly improve our knowledge about cluster merger rates, electron acceleration mechanisms in cluster radio halos, and magnetic field in the ICM.

79 ASTRONOMY AND ASTROPHYSICS↗

Hunting extreme BL Lacertae blazars with Fermi-Large Area Telescope

ABSTRACT The emission of very-high-energy (VHE) photons ($E\ \gt\ 100\ \mathrm{GeV}$) in blazars is closely connected to the production of ultra-relativistic particles and the role of these γ-ray sources as cosmic particle accelerators. This work focuses on a selection of 22 γ-ray objects from the 2BIGB catalogue of high-synchrotron-peaked sources, which are classified as blazar candidates of uncertain type in the 4FGL-DR2 catalogue. We study these sources by means of a re-analysis of the first 10 yr of γ-ray data taken with the Fermi-Large Area Telescope, including the attenuation by the extragalactic background light. Their broad-band spectral energy distributions are also evaluated, using multiwavelength archival data in the radio, optical, and X-ray bands, in terms of one-zone synchrotron-self-Compton models, adding an external Compton component when needed. Out of this analysis, we identify 17 new extreme high-synchrotron-peaked (EHSP) candidates and compare their physical parameters with those of prototypical EHSP blazars. Finally, the resulting models are used to assess their detectability by the present and future generation of ground-based Imaging Atmospheric Cherenkov Telescopes. We find two VHE candidates within the reach of the current and next generation of Cherenkov telescopes: J0847.0−2336 and J1714.0−2029.

Nievas Rosillo, M. (ORCID:0000000283219168)↗

Hunting extreme BL Lacertae blazars with Fermi-Large Area Telescope

The emission of very-high-energy (VHE) photons (⁠E > 100 GeV⁠) in blazars is closely connected to the production of ultra-relativistic particles and the role of these γ-ray sources as cosmic particle accelerators. This work focuses on a selection of 22 γ-ray objects from the 2BIGB catalogue of high-synchrotron-peaked sources, which are classified as blazar candidates of uncertain type in the 4FGL-DR2 catalogue. We study these sources by means of a re-analysis of the first 10 yr of γ-ray data taken with the Fermi-Large Area Telescope, including the attenuation by the extragalactic background light. Their broad-band spectral energy distributions are also evaluated, using multiwavelength archival data in the radio, optical, and X-ray bands, in terms of one-zone synchrotron-self-Compton models, adding an external Compton component when needed. Out of this analysis, we identify 17 new extreme high-synchrotron-peaked (EHSP) candidates and compare their physical parameters with those of prototypical EHSP blazars. Finally, the resulting models are used to assess their detectability by the present and future generation of ground-based Imaging Atmospheric Cherenkov Telescopes. We find two VHE candidates within the reach of the current and next generation of Cherenkov telescopes: J0847.0−2336 and J1714.0−2029.

M Nievas Rosillo↗

Computed Tomography by Combining Transmission and Scatter Radiography Methods

In 2015, approximately 13 billion tons of freight was transported in the US, roughly 40 tons per person. 40% of all freight on a ton-mile basis will be transported by railroads. Class I railroads have approximately 140,000 miles (224,000 km) of railroad track across the country. Approximately 3,200 crossties per mile secure the rails at the proper gauge, transmit loads to the ballast, and prevent lateral and longitudinal shifting. Wood crossties can fail in many ways including rotting, breaking, cracking, and splitting. Developing new technologies to inspect these crossties are necessary to help maintain and ensure safe railroad operations. The Georgetown Railroad Equipment Company partnered with the University of Florida to develop the Aurora Xi X-ray backscatter inspection system. This system generates 2D backscatter images at 25 mph to detect weakness in wood crossties long before the internal degradation is visible on the tie surface. The railroad industry has a need for a high-speed high resolution 3D inspection method to inspect approximately 20 million newly fabricated railroad crossties per year. Currently new ties are not radiographically inspected to reject internal flaws and verify that rot prevention treatments have adequately penetrated into the crosstie. Current spiral scan computed tomography (CT) systems are not designed for the 100 cm/s to 400 cm/s speed of a wood crosstie production line. Building on the technology developed for the 2D Aurora Xi system, a new 3D fan-beam inspection system and CT method is being developed. A previous scatter CT method by Arsenault and Hussein required moving the Xray source to many positions, averaging the X-ray spectra, and ignoring the Compton scatter change of energy. The proposed design and method combines transmission and scatter radiography in all directions without moving or rotating the X-ray sources or detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of calibration materials to improve dual-energy CT scanning for petrophysical applications

Dual energy CT-scanning is a rapidly emerging imaging technique employed in non-destructive evaluation of various materials. Although CT (Computerized Tomography) has been used for characterizing rocks and visualizing and quantifying multiphase flow through rocks for over 25 years, most of the scanning is done at a voltage setting above 100 kV for taking advantage of the Compton scattering (CS) effect, which responds to density changes. Below 100 kV the photoelectric effect (PE) is dominant which responds to the effective atomic numbers (Zeff), which is directly related to the photo electric factor. Using the combination of the two effects helps in better characterization of reservoir rocks. The most common technique for dual energy CT-scanning relies on homogeneous calibration standards to produce the most accurate decoupled data. However, the use of calibration standards with impurities increases the probability of error in the reconstructed data and results in poor rock characterization. This work combines ICP-OES (inductively coupled plasma optical emission spectroscopy) and LIBS (laser induced breakdown spectroscopy) analytical techniques to quantify the type and level of impurities in a set of commercially purchased calibration standards used in dual-energy scanning. The Zeff data on the calibration standards with and without impurity data were calculated using the weighted linear combination of the various elements present and used in calculating Zeff using the dual energy technique. Results show 2 to 5% difference in predicted Zeff values which may affect the corresponding log calibrations. The effect that these techniques have on improving material identification data is discussed and analyzed. The workflow developed in this paper will translate to a more accurate material identification estimates for unknown samples and improve calibration of well logging tools.

42 ENGINEERING↗

Potential origin of the state-dependent high-energy tail in the black hole microquasar Cygnus X-1 as seen with INTEGRAL

Context. 0.1–10 MeV observations of the black hole microquasar Cygnus X-1 have shown the presence of a spectral feature in the form of a power law in addition to the standard black body (0.1–10 keV) and Comptonization (10–200 keV) components observed by INTEGRAL in several black-hole X-ray binaries. This so-called “high-energy tail” was recently shown to be strong in the hard spectral state of Cygnus X-1, and, in this system, has been interpreted as the high-energy part of the emission from a compact jet. Aims. This result was nevertheless obtained from a data set largely dominated by hard state observations. In the soft state, only upper limits on the presence and hence the potential parameters of a high-energy tail could be derived. Using an extended data set, we aim to obtain better constraints on the properties of this spectral component in both states. Methods. We make use of data obtained from about 15 years of observations with the INTEGRAL satellite. The data set is separated into the different states and we analyze stacked state-resolved spectra obtained from the X-ray monitors, the gamma-ray imager, and the gamma-ray spectrometer (SPI) onboard. Results. A high-energy component is detected in both states, confirming its earlier detection in the hard state and its suspected presence in the soft state with INTEGRAL, as seen in a much smaller SPI data set. We first characterize the high-energy tail components in the two states through a model-independent, phenomenological analysis. We then apply physical models based on hybrid Comptonization (eqpair and belm). The spectra are well modeled in all cases, with a similar goodness of the fits. While in the semi-phenomenological approach the high-energy tail has similar indices in both states, the fits with the physical models seem to indicate slightly different properties. Based on this approach, we discuss the potential origins of the high-energy components in both the soft and hard states, and favor an interpretation where the high-energy component is due to a compact jet in the hard state and hybrid Comptonization in either a magnetized or nonmagnetized corona in the soft state.