Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Fourier spectrum of beams chopped by circular apertures.

The circular apertures in the case investigated are uniformly spaced. It is assumed that modulation does not alter beam collimation and that diffraction from aperture edges can be neglected. It is also assumed that the diameter of the apertures is equal to the spacing between the trailing edge and the leading edge of successive apertures. The motion of apertures across the beam is rectilinear. Calculations have been performed for both homogeneous and bivariate normal intensity distributions. The absolute values of the first six Fourier coefficients are plotted as a function of the beam radius normalized to aperture radius.

Cohen, S. C.↗

Improved format for radiocardiographic data

Technique involves introduction of radioactive sample into antecubital vein. Scintillation crystal mounted in collimating housing views portion of right and left hearts. As radioactive sample passes through heart, counting rate is measured by crystal and recorded on strip chart. Data is insensitive to geometric effects and other parameters.

Dimeff, J.↗

Coherent Optical Processing of Phased Array Radar Data

Interfacing a coherent optical processor, which utilizes an electron-beam addressed, potassium dideuterium phosphate (KDP) crystal modulator, with a linear phased array is studied. An abbreviated development of typical radar signals from a linear array is included. A plan for formating the spatial modulator with linear array signals is presented. The theoretical expectations which include target angle and Doppler are derived. A simulated set of M signals which are typical of a linear array of M elements was devised. This set of signals was used to modulate the wave front of collimated laser light via the KDP crystal according to the format presented.

Rogers, J. W.↗

Real-time Optical Alignment and Diagnostic System (ROADS)

The ultimate and most frequent usage of ROADS will be the alignment of subassemblies (collector and collimator) prior to their installation in a chamber. The system as designed has inherent associated capabilities well applied to acceptance testing of the No. 4 mirror, prediction of in-chamber performance, generation of a catalog of test results and other data, providing data for the plotting of isointensity lines, and other applications which are discussed. The ROADS system will collect, process, display, analyze, and retain data as required for components, partial subassemblies, complete subassemblies, complete modules, and multimodular arrays.

Source record↗

Experimental study of spectral and spatial distribution of solar X-rays

The study of the physical conditions within the solar corona and the development of instrumentation and technical expertise necessary for advanced studies of solar X-ray emission are reported. Details are given on the Aerobee-borne-X-ray spectrometer/monochromator and also on the observing program. Preliminary discussions of some results are presented and include studies of helium-like line emission, mapping O(VII) and Ne(IX) lines, survey of O(VII) and Ne(IX) lines, study of plage regions and small flares, and analysis of line emission from individual active regions. It is concluded that the use of large-area collimated Bragg spectrometers to scan narrow wavelength intervals and the capability of the SPARCS pointing control to execute a complex observing program are established.

Acton, L. W.↗

HEAO-B X-ray experiments. Non-dispersive spectroscopy

The scientific objectives of HEAO-B are presented. They include four X-ray and gamma ray experiments in addition to two charged cosmic ray experiments. The first X-ray experiment is one using standard proportional counters, mechanically collimated, and covers the region from 0.2 to 60 keV. It is being designed for the purpose of detecting small changes in the surface brightness of the X-ray sky over a very broad spectral range. The second X-ray experiment involves Bragg crystal spectrometers for the range 0.5 to 10 keV. In the low energy gamma ray experiment, which also extends into the X-ray region, a cooled germanium (lithium drifted) gamma-ray spectrometer was used.

Boldt, E. A.↗

Study of artificially generated and natural auroras

The feasibility of generating artificial auroras by injecting electrons into the upper atmosphere was investigated by using an electron accelerator aboard an Aerobee 350 rocket. Four of the artificial auroral rays were detected and recorded by two geophysical sites separated enough to enable the spatial coordinates of the rays to be determined by triangulation. It was found that (1) the beam remained well collimated; (2) most of the initial beam energy was deposited in the atmosphere; (3) plasma instabilities did not play a significant role; and (4) the orientations of the rays were determined with sufficient accuracy to improve the knowledge of the earth's magnetic field over the Virginia coast. The publications resulting from this research are listed.

Davis, T. N.↗

Primary electron spectrometer, 18:63 UE: Electrostatic analyzer description and energy spectrum determination

The primary electron spectrometer used to detect auroral electrons on sounding rocket 18:63 UE is described. The spectrometer used exponentially decaying positive and negative voltages applied to spherical deflection plates for energy analysis. A method for determining the analyzer response which does not require the assumptions that the ratio of plate separation to mean radius, the entrance or the exit apertures are small is described. By comparison with experiment it is shown that the effect of neither entrance nor exit collimation can be ignored. The experimental and calculated values of the limiting orbits agree well. A non-iterative technique of unfolding the electron differential energy spectrum is described. This method does not require the usual assumption of a flat or histogram-type energy spectrum. The unfolded spectra using both this technique and one which assumes a flat spectrum are compared to actual input spectra. This technique is especially useful in analyzing peaked auroral electron energy spectra.

Pongratz, M. B.↗

Retrieval of dispersive and convective transport phenomena in fluids using stationary and nonstationary time domain analysis

Simultaneously occuring dispersive and convective components of fluid kinematics are obtained by a time domain analysis of optically retrieved temporal histories of the transport phenomena. Utilizing triangulation of collimated optical fields of view from two radiometers to obtain the temporal histories of the intensity fluctuations associated with the transport phenomena has enabled investigators to retrieve the local convective transport by employing correlation statistics. The location of the peak in the covariance curve determines the transit time from which the convection velocity is calculated; whereas, the change in shape of the peak in the covariance curve determines the change in average frequency of the wave packet from which the dispersion velocity is calculated. Thus, two-component analysis requires the maximum possible enhancement of the delineation for the transport. The convection velocity is the result of a fixed reference frame calculation whereas, the dispersion velocity is the result of a moving reference frame calcuation.

Stephens, J. B.↗

Compton scatter attenuation gamma ray spectrometer

A gamma ray spectrometer is described for use in intense radiation fields such as those in the vicinity of a rocket engine exhaust. A collimated radiation beam is Compton scattered toward shielded spectrometers to reduce the energy and intensity of the radiation and is energy selective among the spectrometers. The scattering targets are changeable to control the percentage of the radiation scattered. Sum-Compton coincidence techniques are employed for data selection.

Austin, W. E.↗

Advances in solar and cosmic X-ray astronomy - A survey of experimental techniques and observational results.

The current status of X-ray astronomy is surveyed by reviewing observational results and theoretical conclusions gained within the past two years in areas dealing with the quiet-sun, slowly-varying, and burst components of solar X-radiation and with the features of cosmic X-ray sources. Thermal and nonthermal processes responsible for a wide variety of X-ray emission mechanisms in nature are explained, and characteristics of X radiation from specific solar structures are described. Attention is given to the effects of interstellar and intergalactic matter on cosmic X-rays; the properties of galactic and extragalactic X-ray sources; and the specifications of such instruments as gas-filled ionization detectors, proportional counters, Geiger counters, scintillation detectors, photoelectric detectors, polarimeters, collimators, spectrometers, and imaging systems.

Hoover, R. B.↗

Coronal survey in X-rays of O VII and Ne IX.

Results of a rocket experiment flown on Apr. 29, 1971, in which a survey of the solar corona was carried out with a pair of collimated Bragg spectrometers to study the resonance, intersystem, and forbidden line emission from the helium-like ions O vii (22 A) and Ne ix (13 A). The observed X-ray emission came from the general corona, seven plage regions, and one dynamic feature - the late stage of a small flare. From the intensity of the O vii and Ne ix resonance lines the electron temperature and emission measure of the individual emitting regions are derived on the basis of two models, one in which the region is assumed to be isothermal and another in which the emission measure decreases exponentially with increasing temperature. The latter model, which is the most adequate of the two, yields for the electron temperature of the time-varying feature 2,000,000 to 3,000,000 K, for the other active regions 1,500,000 to 2,500,000 K, and for the general corona 1,300,000 to 1,700,000 K. The Ne ix emitting regions are about 1.5 times as hot as the O vii regions.

Acton, L. W.↗

Method of measuring the thickness of radioactive thin films

Thickness monitor consists of proportional X-ray counter coupled to pulse counting system, copper filter over face of counter, rotatable collimator containing radioactive source, and rotatable shutter. Monitor can be used as integral part of neutron generator. It has been used to measure titanium tritide film thicknesses from 0.1 to 30 micrometers.

Alger, D. L.↗

A low cost ""Air Mass 2'' solar simulator

Tungsten halogen projection lamps have integral ellipsoidal reflector, and hexagonal shaped plastic Fresnel lenses. Reflector is dichroic coated to reduce infrared content of reflected radiation. Array of lamps and lenses produces uniform collimated beam having near AM2 spectrum and intensity that can be used for testing flat plate solar collectors.

Yass, K.↗

Acoustic-optic deflector telescope

In construction of page-organized holographic memories, it is necessary to provide collimated laser beam which can be deflected parallel to itself. This is used for selecting stored holograms from two-dimensional array. Three-lens system significantly reduces optical path length.

Stewart, W. C.↗

Low-cost, air mass 2 solar simulator

A low cost air mass 2 solar simulator for testing flat-plate solar collectors was developed and operated at Lewis. Total cost was less than $10,800/sq m ($1000/sq ft). It consists of an array of 143 tungsten-halogen 300-watt lamps, each having integral dichroic coated reflectors. A second array of 143 respective hexagonal-shaped plastic Fresnel lenses are located approximately 1 focal length from the lamps. The simulator will produce a uniform collimated beam covering an area of 1.2 by 1.2m(4 by 4 ft). Design features, construction details, and component costs are given, as well as measured results on a 12-lamp prototype.

Yass, K.↗

High resolution solar X-ray studies

Two high resolution solar X-ray payloads and their launches on Aerobee rockets with pointing system are described. The payloads included 5 to 25A X-ray spectrometers, multiaperture X-ray cameras, and command box attitude control inflight by means of a television image radioed to ground. Spatial resolution ranged from five arc minutes to ten arc seconds and spectral resolution ranged from 500 to 3000. Several laboratory tasks were completed in order to achieve the desired resolution. These included (1) development of techniques to align grid collimators, (2) studies of the spectrometric properties of crystals, (3) measurements of the absorption coefficients of various materials used in X-ray spectrometers, (4) evaluation of the performance of multiaperture cameras, and (5) development of facilities.

Blake, R. L.↗

Depolarization of an uncollimated laser beam in a turbulent medium

The depolarization of a beam wave, with Gaussian intensity distribution and arbitrary divergence, propagating in a turbulent medium is considered. The correlation function of the depolarized component of the beam is determined. The mean-square depolarization fluctuation is then determined for a medium characterized by a Kolmogorov spectrum. If the beam is assumed to be collimated, this expression reduces to that of Collett and Alferness; if the plane-wave limiting case of the Gaussian beam is taken, the results in this paper agree with those of Strohbehn. The results show that off the beam axis the depolarization can be greater than for the plane wave, and that near the beam focal point the depolarization may decrease by orders of magnitude.

Chang, F. C.↗