Tool For Friction Stir Tack Welding of Aluminum Alloys

A small friction-stir-welding tool has been developed for use in tack welding of aluminum-alloy workpieces. It is necessary to tack-weld the workpieces in order to hold them together during friction stir welding because (1) in operation, a full-size friction-stir-welding tool exerts a large force that tends to separate the workpieces and (2) clamping the workpieces is not sufficient to resist this force. It is possible to tack the pieces together by gas tungsten arc welding, but the process can be awkward and time-consuming and can cause sufficient damage to necessitate rework. Friction stir tack welding does not entail these disadvantages. In addition, friction stir tack welding can be accomplished by use of the same automated equipment (except for the welding tool) used in subsequent full friction stir welding. The tool for friction stir tack welding resembles the tool for full friction stir welding, but has a narrower shoulder and a shorter pin. The shorter pin generates a smaller workpiece-separating force so that clamping suffices to keep the workpieces together. This tool produces a continuous or intermittent partial-penetration tack weld. The tack weld is subsequently consumed by action of the larger tool used in full friction stir welding tool.

Bjorkman, Gerald W.↗

Device for Locking a Control Knob

A simple, effective, easy-to-use device locks a control knob in a set position. In the initial application for which this device was conceived, the control knob to be locked is that of a needle valve. Previously, in that application, it was necessary for one technician to hold the knob to keep the valve at the desired flow setting while another technician secured the valve with safety wire -- a time-consuming procedure. After attachment of the wire, it was still possible to turn the knob somewhat. In contrast, a single technician using the present device can secure the knob in the desired position. in about 30 seconds, and the knob cannot thereafter be turned, even in the presence of harsh vibrations, which occur during space shuttle launch. The device includes a special-purpose clamp that fits around the control knob and its shaft and that can be tightened onto the knob, without turning the knob, by means of two thumbscrews. The end of the device opposite the clamp is a tang that contains a slot that, in turn, engages a bolt that protrudes from the panel on which the control knob and its shaft are mounted.

Grom, Dave↗

Evaluation of Underwater Adhesives and Friction Coatings for In Situ Attachment of Fiber Optic Sensor System for Subsea Applications

Integrity and performance monitoring of subsea pipelines and structures provides critical information for managing offshore oil and gas production operation and preventing environmentally damaging and costly catastrophic failure. Currently pipeline monitoring devices require ground assembly and installation prior to the underwater deployment of the pipeline. A monitoring device that could be installed in situ on the operating underwater structures could enhance the productivity and improve the safety of current offshore operation. Through a Space Act Agreement (SAA) between the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) and Astro Technology, Inc. (ATI), JSC provides technical expertise and testing facilities to support the development of fiber optic sensor technologies by ATI. This paper details the first collaboration effort between NASA JSC and ATI in evaluating underwater applicable adhesives and friction coatings for attaching fiber optic sensor system to subsea pipeline. A market survey was conducted to examine different commercial ]off ]the ]shelf (COTS) underwater adhesive systems and to select adhesive candidates for testing and evaluation. Four COTS epoxy based underwater adhesives were selected and evaluated. The adhesives were applied and cured in simulated seawater conditions and then evaluated for application characteristics and adhesive strength. The adhesive that demonstrated the best underwater application characteristics and highest adhesive strength were identified for further evaluation in developing an attachment system that could be deployed in the harsh subsea environment. Various friction coatings were also tested in this study to measure their shear strengths for a mechanical clamping design concept for attaching fiber optic sensor system. A COTS carbide alloy coating was found to increase the shear strength of metal to metal clamping interface by up to 46 percent. This study provides valuable data for assessing the feasibility of developing the next generation fiber optic senor system that could be retrofitted onto existing subsea pipeline structures.

Tang, Henry H.↗

Test Methodology Development for Experimental Structural Assessment of ASC Planar Spring Material for Long-Term Durability

A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses

fatigue testing machines↗

Preload Loss in a Spacecraft Fastener via Vibration-Induced Unwinding

Sound engineering practice requires that fasteners and bolted joints maintain preload in service. NASA recently concluded a series of vibration tests of a multicomponent structure intended to simulate an upper stage section of a launch vehicle. The stacked components were joined through six circumferentially placed bolted cup-cone-style pyrotechnic joint mechanisms designed to share spacecraft structural loads and then enable separation during ascent. Over the course of the vibration test campaign, all six bolted cup-cone mechanisms experienced some degree of preload loss with two mechanisms losing half of their original bolt preload. A subsequent forensic anomaly investigation concluded that vibration-induced unwinding of the preload nut-and-bolt assemblies occurred despite the use of safety wire and high levels of thread friction. A series of experiments were done to better understand how large, heavily preloaded fasteners could unwind. Additionally, thread friction torque was measured and the fastener locking capability of safety wire was evaluated. The friction coefficient between the clamped cup-cone components was characterized and finally a highly instrumented mechanism-level vibration test was done to reproduce the unwinding phenomenon to better understand the mechanism's behavior. The conclusion drawn was that vibration and structural forces led to relative motion (sliding) of the clamped components, resulting in self-loosening and unwinding effects on the nut-and-bolt assembly. To counter this phenomenon, more effective fastener locking methodologies were recommended and a follow-on effort was initiated to quantify the relationship between preload, component motion, and resulting unwinding forces. It is hoped that elucidation of these effects can be used to design more effective fastener locking features.

fasteners↗

Quick-Replacement High-Temperature Superconducting Current Leads for Use in a Research Cryostat

We report the use of a series of high-temperature superconducting leads in a cryostat that require no soldering to replace in the event of a failed lead. The temperature range spanned by the leads is 50 to 3 degrees Kelvin and they typically carry currents up to 4 amperes although they have a much higher capacity in this temperature range. The leads are integrated into the cryostat by clamping both ends to gold-plated copper pads. Support of the leads over the 25-centimeter length is provided by a simple G10 strong back. Details of the clamping interface, measurements of joint resistances, and other interesting observations will be discussed.

Superconductivity↗

Mechanics of Preloaded Bolt Tensile Loading With Focus on Load Introduction Factor

The bolt tensile and joint separation loads are directly influenced by the locations at which the external loads enter the clamped members of a preloaded bolted joint (PBJ) and the associated load-paths through the joint. This physical load introduction mechanism affecting the bolt tensile loading is typically represented in the bolt tensile load equation, in part, by a load introduction factor (LIF), which was shown by H.M. Lee of Marshall Spaceflight Center to be a natural product of the bolt tensile load equation using a linear spring stiffness model. This LIF, being a function of load-path stiffness, has subsequently been denoted as the stiffness-based LIF (SBLIF), providing a framework to calculate the LIF using whatever load-path stiffness approximations are appropriate. Expanding upon the work of Lee, it is shown that the SBLIF and the joint stiffness factor are functions of the stiffnesses of the same load-paths and regions within a PBJ, and thus they should not be treated as independent variables. Mathematical expressions for the SBLIF are presented. Comparisons are shown between the analytically calculated SBLIF, the analytically calculated geometric LIF (GLIF), which is a simple clamped-member thickness ratio, the experimentally derived LIF, and the LIF determined by finite element analysis (FEA). Using experiment and FEA as a benchmark, the SBLIF, using traditional load-path stiffness approximations, enables a more accurate prediction of bolt tensile loading than the GLIF, although it can be unconservative near joint separation. The GLIF generally attributes more of the externally applied tensile load to the bolt than does the SBLIF, potentially resulting in heavier and/or more costly bolted joints. Mathematical relationships between the SBLIF and the GLIF are developed. Supplemental material is provided in the appendixes where the historical practice of using the joint compressive stiffness in place of the joint tensile stiffness is evaluated. The appendixes include step-by-step examples demonstrating the calculation of the SBLIF using traditional stiffness approximations and conclude with the development of the joint diagram in terms of the SBLIF, culminating into formulas for the key features of a joint diagram, which is useful for programming.

Load Path↗

Fluid-Thermal-Structural Interactions Induced by an Asymmetric Shock-Wave/Boundary-Layer Interaction in a Mach-6 Compression Corner

An experimental study is conducted of the fluid-thermal-structural interaction of a clamped compliant panel exposed to a three dimensional shock-wave/boundary-layer interaction (SWBLI) induced by a Mach-6 compression ramp with a spanwise nonuniform incoming boundary layer. The nonuniform boundary layer was produced by placing trips on one side of the upstream flat plate, resulting in largely turbulent flow on the tripped side and transitional flow on the untripped side. Measurements of the flowfield confirmed that the tripped boundary layer contained elevated levels of unsteadiness, and the SWBLI was observed to vary from attached to fully separated as the ramp angle was increased from 10◦ to 38◦; the separation region on the tripped side of the panel was noticeably smaller, showing the elevated turbulence levels of the tripped-side flow to remain relatively localized rather than diffusing across the whole model. Full-field, time-resolved panel deformations were measured using high-speed photogrammetry and the vibrational response at each compression angle was characterized. Although the measured modes conformed largely to those from classical clamped-plate theory, some skewing of the mode shapes was observed. IR thermography highlighted regions of the compliant region where elevated temperatures were likely to promote thermal softening effects to the transient panel response. The quasi-static deformation and stress field was used to characterize the internal stress factor of each mode and showed a meaningful relationship between transient panel response and stress contained within each mode: modes with antinodes lying in high-stress areas of the plate tended to exhibit increases in vibrational frequency and decreases in vibrational power, whereas the opposite was true for modes with antinodes in low-stress areas.

Spectral Proper Orthogonal Decomposition↗

Interleaved multi-channel, multi-level, multi-quadrant DC-DC converters

Direct-current-to-direct-current (DC-DC) power converters that include two or more multi-quadrant, multi-level, DC-DC, switching converter subcircuits, connected in parallel at respective input and output sides, so as to provide a multi-channel, multi-quadrant, multi-level configuration, are disclosed. The DC-DC power converters further include a control circuit configured to control the switching converter subcircuits so that corresponding switching semiconductors in each of the switching converter subcircuits are switched in an interleaved manner. In some embodiments, each of the switching converter subcircuits is a three-level, neutral-point-clamped, four-quadrant DC-DC converter circuit. In other embodiments, each of the switching converter subcircuits is a three-level, neutral-point-clamped, two-quadrant DC-DC converter circuit. In any of these embodiments, a filter capacitor may be connected between across a pair of output terminals at the output sides of the switching converter subcircuits.

Du, Yu↗

TREAT Slide Decks for Alabama A&M

Slides to introduce TREAT and two senior design projects to a professor and senior engineering students at Alabama A&M. Slide Deck 1 is an overview of the TREAT Reactor and its mission. Use for Space Nuclear Thermal Propulsion Testing is mentioned, but no details of space reactor fuel are included. Review for unlimited release is requested. Slide deck 2 presents technical background for neutron radiography, with contrast to x-radiography, and then presents the application of TREAT for Flash Radiography. Slide Deck 3 describes the background behind the second senior design project, which is to design powered actuators for TREAT core clamps. Slide Deck 3 includes photos of different sides of the TREAT reactor and sketches of internal components associated with the core clamping system. These were presented via Teams on October 5, but we want to provide the slidedeck files to the university for student reference.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Digital Three Level Space Vector Modulator for High Frequency Vector Sequence Generation

This letter proposes a digital high-speed three-level space vector pulse width modulator (3L-SVPWM). A conventional 3L-SVPWM is typically computation-based, involving a sequential execution of sub-tasks on a digital signal processor (DSP) based controller. The resulting high computation time of 5.4 μs limits the implementation of additional control blocks for switching frequencies greater than 100 kHz. This is overcome by transforming sub-tasks into digital blocks with 1-0 decisions and simpler arithmetic operations. The sub-task blocks are executed concurrently on a programmable logic device (PLD). Hence, a fast 3L-SVPWM execution in 140 ns is achieved. The proposed digital 3L-SVPWM enables high switching frequency operation of wide bandgap (WBG) device-based 3 L inverters to generate high fundamental frequency waveforms. A finite state machine is an integral part of the proposed implementation with the ability to generate any vector sequence, maximizing the usage of redundant vector states in 3L-SVPWM. Here, the proposed digital 3L-SVPWM operation is demonstrated with a GaN-based 3 L active neutral point clamped (3L-ANPC) inverter. Experimental results are presented at 250 kHz switching frequency to generate vector sequences for center-aligned SVPWM (CA-SVPWM) and common mode voltage reduced SVPWM (CMVR-SVPWM). The results also showcase a high fundamental frequency generation capability of 10 kHz.

active neutral point clamped inverter↗

A Generic Two-Vector Model Predictive Control for Hybrid Multilevel Converters

In this article, a generic two-vector model predictive control (TV-MPC) strategy is proposed for the hybrid multilevel converters (HMCs). The proposed method selects two optimal voltage vectors among all the vector candidates using a geometric positioning approach to reduce the computational burden, which is a common issue in the existing MPC methods for HMC. Then duty cycles of the two selected vectors are optimized to minimize the current tracking error, such that the current tracking performance can be enhanced compared with the conventional MPC. In addition, the voltages of the floating dc capacitors can be balanced by evaluating all switching sequences that belong to the optimal voltage vectors with optimal duty cycles. Here, the concept of the proposed TV-MPC is generic and applicable for any HMCs. A typical HMC based on active neutral-point-clamped topology is adopted as a case study in this work. Comprehensive simulation and experimental studies are performed on an all silicon-carbide HMC prototype to validate the effectiveness of the proposed control scheme.

42 ENGINEERING↗

A New Configuration of Paralleled Modular ANPC Multilevel Converter Controlled by an Improved Modulation Method for 1 MHz, 1 MW EV Charger

In this work, a new configuration of the modular multilevel converter (MLC) based on the parallel connection of three-level active-neutral-point-clamped (3L-ANPC) cells as well as its improved modulation method is proposed for 1 MHz, 1 MW electric vehicle (EV) megacharger. In the proposed paralleled modular ANPC-MLC, only six high-frequency silicon carbide (SiC) power switches operating at 333 kHz are required to generate 1 MHz switching frequency spectrum. Moreover, the operating voltage of all power devices is halved, the magnitude of the first switching frequency harmonic cluster is decreased by the factor of five, and the load current is equally distributed between the 3L-ANPC legs by employing the proposed improved modulation method. Hence, the modularity, efficiency, and power density of the proposed converter are notably increased, whereas the value of passive components and the overall switching loss are remarkably decreased. In addition, an optimized design of the one 3L-ANPC cell of the proposed paralleled modular ANPC-MLC for 1 MHz, 1MW EV megacharger using Ansys SIwave, Icepak, and Q3D finite element method platforms is presented and analyzed in detail. The provided experimental results of the down-scaled setup verify the feasibility and viability of the proposed configuration as well as its improved switching pattern.

42 ENGINEERING↗

A Virtual Space Vector Model Predictive Control for a Seven-Level Hybrid Multilevel Converter

This paper proposes a virtual space vector (VSV) model predictive control (MPC) for a three-phase seven-level (7L) hybrid multilevel converter (HMC), where each phase consists of an active-neutral-point-clamped converter with a floating H-bridge. To achieve the best current tracking, which is the primary goal of the proposed algorithm, a novel geometrical positioning approach is proposed to select the optimal voltage vector among all the realspace vectors and VSVs. Then, all the possible switching sequences that belong to the optimal voltage vector are evaluated to realize the dc capacitor voltage balancing and common-mode voltage reduction. Through an external modulator, the optimal voltage vector can be synthesized by using either one-, three-, or seven-segment switching sequence. Compared with the conventional MPC, the proposed VSV-MPC can reduce not only the computational burden but also the current THD. Both simulation and experimental results obtained on silicon carbide based 7L-HMC prototype are presented to validate the feasibility and effectiveness of the proposed VSVMPC strategy.

42 ENGINEERING↗

Simplified Two-Stage Model Predictive Control for a Hybrid Multilevel Converter With Floating H-Bridge

This paper proposes a simplified two-stage model predictive control (ST-MPC) for a hybrid multilevel converter, which is an active-neutral-point-clamped converter with floating H-bridge (ANPC-H). The objective of the first stage is to select the voltage vector that has the optimal current tracking performance by using a novel geometrical positioning approach in the complex plane. The second stage selects the best switching state among all the available switching states that belong to the same voltage vector obtained in the first stage, to balance dc capacitor voltages and reduce the common mode voltage. The proposed ST-MPC can dramatically reduce the computational burden and ensure the best current tracking by the two-stage structure, such that the execution time is much shorter compared with the conventional MPC. In addition, the geometrical positioning approach in the first stage is generic and can be applicable for any multilevel converters with N-level output; thus, this ST-MPC can be applied for both sevenand nine-level operation of the hybrid ANPC-H converter under different dc voltage ratios. Both simulation results and experimental results obtained on a silicon carbide hybrid ANPC-H converter prototype validate the feasibility and effectiveness of the proposed ST-MPC strategy.

42 ENGINEERING↗

Flaming Moe

Current clamp measurements collected on various small electronic devices. Details on the data set can be found in J. M. Vann, T. P. Karnowski, R. Kerekes, C. D. Cooke and A. L. Anderson, A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions, in IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 1, pp. 122-131, Feb. 2018, doi: 10.1109/TEMC.2017.2692962.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Efficiency OLED Light Engine

LED Specialists has accomplished the program objective in designing a high efficiency OLED light engine combining high-performance OLED panels in the 5W-8W range. We achieved our goal by using an Active-Clamp Flyback circuit topology using state-of-the-art electronics. Evaluation testing of our second-generation prototype PC board has demonstrated an efficiency rating of 93% and dimming capability between 100% and 5% of OLED brightness. A reliability analysis of the design shows it to have a predicted Mean Time Between Failures (MTBF) of approximately 1,000,000 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model study of ATP and ADP buffering, transport of Ca(2+) and Mg(2+), and regulation of ion pumps in ventricular myocyte

We extended the model of the ventricular myocyte by Winslow et al. (Circ. Res 1999, 84:571-586) by incorporating equations for Ca(2+) and Mg(2+) buffering and transport by ATP and ADP and equations for MgATP regulation of ion transporters (Na(+)-K(+) pump, sarcolemmal and sarcoplasmic Ca(2+) pumps). The results indicate that, under normal conditions, Ca(2+) binding by low-affinity ATP and diffusion of CaATP may affect the amplitude and time course of intracellular Ca(2+) signals. The model also suggests that a fall in ATP/ADP ratio significantly reduces sarcoplasmic Ca(2+) content, increases diastolic Ca(2+), lowers systolic Ca(2+), increases Ca(2+) influx through L-type channels, and decreases the efficiency of the Na(+)/Ca(2+) exchanger in extruding Ca(2+) during periodic voltage-clamp stimulation. The analysis suggests that the most important reason for these changes during metabolic inhibition is the down-regulation of the sarcoplasmic Ca(2+)-ATPase pump by reduced diastolic MgATP levels. High Ca(2+) concentrations developed near the membrane might have a greater influence on Mg(2+), ATP, and ADP concentrations than that of the lower Ca(2+) concentrations in the bulk myoplasm. The model predictions are in general agreement with experimental observations measured under normal and pathological conditions.

NASA Discipline Cardiopulmonary↗