Simulation-based analysis of different curb space type allocations on curb performance

Curbspace is a limited resource in urban areas. Delivery, ridehailing and passenger vehicles must compete for spaces at the curb. Cities are increasingly adjusting curb rules and allocating curb spaces for uses other than short-term paid parking, yet they lack the tools or data needed to make informed decisions. In this research, we analyze and quantify the impacts of different curb use allocations on curb performance through simulation, covering various mixes of curbspace uses (bus stops, paid parking, passenger pick-up/drop-off zones, and commercial vehicle loading zones), parking rules, and driver rule compliance. Three metrics (including two new ones) are developed to evaluate the performance of the curb, covering productivity and accessibility of passengers and goods, and CO 2 emissions. The metrics are calculated for each scenario across a wide range of input parameters (traffic volume, parking demand rate, vehicle dwell time, and street design speed) and compared to each other and to a baseline scenario. This work can inform policy decisions by providing municipalities a tool to analyze various curb management strategies and choose the ones that produce results more in line with their policy goals.

99 GENERAL AND MISCELLANEOUS↗

Assessment of Carbonated Brine Injection as Low-risk Strategy for Geologic Carbon Storage

The main objective of this early-phase research was to evaluate the techno-economic feasibility and risk associated with combined brine and CO 2 storage in SWD wells using brine dissolution in the North Dakota portion of the Williston Basin. Three simulation studies were conducted to investigate: (1) CO 2 phases at different conditions, (2) wellbore compatibility, and (3) long-term storage fate in reservoir. (1) A simple reservoir model and injection simulations were created using data to represent the BEST (brine extraction and storage test) site, an operational SWD facility located near Watford City, North Dakota. The pressure evolution caused by CO 2 comingled in produced water injectate in a layer cake reservoir was then modeled while tracking aqueous CO 2 throughout the project. The salinity of the injection water, the salinity of the reservoir brine, and the amount of dissolved CO 2 comingled in the injection water were varied. (2) A wellbore corrosion model was performed using the CO 2 concentrations selected based on the reservoir modeling to examine the carbonated produced water impact on wellbore. (3) Reactive transport modeling was conducted with the optimal CO 2 concentration for this injection site to study the rock-fluid interactions and CO 2 fate in the reservoir. Results suggest that CO 2 dissolved in produced water can be injected without appreciably increasing subsurface pressure or leakage risks. Pressure buildup was found to vary with salinity but not with CO 2 mass fraction. Simulation results show that lower CO 2 percent mass fraction leads to a higher amount of CO 2 that can be dissolved at a higher injection salinity. Furthermore, the long-term goal of dissolution trapping in a traditional carbon storage project is accomplished from the start, mitigating risks associated with potential migration of buoyant CO 2 , so long as the reservoir pressure and temperature are used to determine the maximum mass fraction of the dissolved CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Radioisotope Analysis of Wastewater from Livermore Site Retention Tanks by Gel Laboratory Gross Alpha, Gross Beta and Tritium Sampling Method

Lawrence Livermore National Laboratory discharged approximately 4.4% of the City of Livermore’s total wastewater in 2022 (LLNL’s Annual Site Environmental Report, Chapter 5, 2022). This volume includes wastewater from Sandia National Laboratories (SNL) and some process wastewater from Site 300. Due to the high volume and constituents of the discharge, LLNL works alongside the City of Livermore under permit #1250, requiring wastewater generated to be monitored and sampled in accordance with permit limits. Process wastewater, from buildings with the highest risk to sewer, is collected by wastewater retention tanks throughout the Livermore Site and sampled prior to discharge. Domestic wastewater directly discharges to sanitary sewer. To maintain permit requirements and ensure proper wastewater discharge practices, an internal wastewater audit was conducted during the summer of 2023. Current wastewater practices, regulatory knowledge and risk management across various Livermore Site buildings were evaluated. Workspaces connected to a wastewater retention tank and sanitary sewer drains were major focus areas. Data collected from walk-throughs prompted further evaluation as many practices were reported to be done based on historical usage. A table of concerns was created to showcase reasons for auditing and proceeding action. An analysis of current and historical retention tank usage throughout LLNL Livermore Site buildings with radioisotope results over a 5-year period from 2019 to 2024, was done to assess building trends and any significant changes throughout the 5-year period. Analytes evaluated were Gross Alpha, Gross Beta and Tritium (GABT) of eleven buildings at the Livermore Site, posing the highest risk to sanitary sewer for radioisotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Asheville Urban Development II: Mapping Urban Heat to Support Cooling Initiatives and Climate Resilience Planning in the Greater Asheville Area

Asheville, North Carolina experiences the urban heat island effect, where temperatures in the city are higher than in surrounding rural areas. This effect intensifies with increased urbanization and less vegetative cover. Asheville’s urban heat island was exacerbated by population increases and tree cover decline, escalating the need for heat mitigation. We partnered with the City of Asheville’s Sustainability Department and Asheville GreenWorks whose actions prioritize sustainable city planning and equitable climate resilience. Using NASA Earth observations and ancillary datasets we spatially mapped urban heat, heat vulnerability, and cooling and adaptive capacity from 2019-2023. To map urban heat, we used Landsat 8 and 9 Operational Land Imager and Thermal Infrared Sensor for land surface temperature and albedo data and the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station for evapotranspiration data. We assessed heat vulnerability using the urban heat data andthe Centers for Disease Control and Prevention’s Social Vulnerability Index. To evaluate cooling and adaptive capacity we used the InVEST Urban Cooling Model, integrating our heat vulnerability analysis with land use and cover data from Sentinel-1 Synthetic Aperture Rada rand Sentinel-2 Multispectral Instrument. Our results revealed distinct spatial patterns of urban heat, heat vulnerability, and cooling and adaptive capacity in Asheville with downtown as the focal hotspot and an outward decreasing radial pattern. These findings highlight targeted need for interventions to reduce heat impacts, address environmental injustices, and enhance climate resilience. Our project provided research to local organizations that can be used for heat mitigation in the greater Asheville area.

Authors not in NED but are confirmed contractors. ↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Climate Change and a Global City: An Assessment of the Metropolitan East Coast Region

The objective of the research is to derive an assessment of the potential climate change impacts on a global city - in this case the 31 county region that comprises the New York City metropolitan area. This study comprises one of the regional components that contribute to the ongoing U.S. National Assessment: The Potential Consequences of Climate Variability and Change and is an application of state-of-the-art climate change science to a set of linked sectoral assessment analyses for the Metro East Coast (MEC) region. We illustrate how three interacting elements of global cities react and respond to climate variability and change with a broad conceptual model. These elements include: people (e.g., socio- demographic conditions), place (e.g., physical systems), and pulse (e.g., decision-making and economic activities). The model assumes that a comprehensive assessment of potential climate change can be derived from examining the impacts within each of these elements and at their intersections. Thus, the assessment attempts to determine the within-element and the inter-element effects. Five interacting sector studies representing the three intersecting elements are evaluated. They include the Coastal Zone, Infrastructure, Water Supply, Public Health, and Institutional Decision-making. Each study assesses potential climate change impacts on the sector and on the intersecting elements, through the analysis of the following parts: 1. Current conditions of sector in the region; 2. Lessons and evidence derived from past climate variability; 3. Scenario predictions affecting sector; potential impacts of scenario predictions; 4. Knowledge/information gaps and critical issues including identification of additional research questions, effectiveness of modeling efforts, equity of impacts, potential non-local interactions, and policy recommendations; and 5. Identification of coping strategies - i.e., resilience building, mitigation strategies, new technologies, education that affects decision-making, and better preparedness for contingencies.

Rosenzweig, Cynthia↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Urbanization-induced land and aerosol impacts on storm propagation and hail characteristics

Changes in land surface and aerosol characteristics from urbanization can affect dynamic and microphysical properties of severe storms, thus affecting hazardous weather events resulting from such storms such as hail and tornado. We examine the joint and individual effects of urban land and anthropogenic aerosols of Kansas City on a severe convective storm observed during the 2015 Plains Elevated Convection At Night (PECAN) field campaign, focusing on storm evolution, convective intensity, and hail characteristics. The simulations are carried out at the cloud-resolving scale (1 km) using a version of WRF-Chem in which the spectral-bin microphysics (SBM) is coupled with the Model for Simulating Aerosol Interactions and Chemistry (MOSAIC). It is found that the urban land effect of Kansas City initiated a much stronger convective cell and the storm got further intensified when interacting with stronger turbulence induced by the urban land. The urban land effect also changed the storm path by diverting the storm toward the city mainly resulting from enhanced urban land-induced convergence in the urban area and around the urban-rural boundaries. The joint effect of urban land and anthropogenic aerosols enhances occurrences of both severe hail and significant severe hail by ~ 20% by enhancing hail formation and growth from riming. Overall the urban land effect on convective intensity and hail is relatively larger than the anthropogenic aerosol effect, but the joint effect is much notable than either of the individual effects, emphasizing the importance to consider both effects in evaluating urbanization effects.

Lin, Yun↗

Use of MODIS Terra Imagery to Estimate Surface Water Quality Standards, Using Lake Thonotosassa, Florida, as a Case Study

Lake Thonotosassa is a highly eutrophied lake located in an area with rapidly growing population in the Tampa Bay watershed, Florida. The Florida Administrative Code has designated its use for "recreation, propagation and maintenance of a healthy, well-balanced population of fish and wildlife." Although this lake has been the subject of efforts to improve water quality since 1970, overall water quality has remained below the acceptable state standards, and has a high concentration of nutrients. This condition is of great concern to public health since it has favored episodic blooms of Cyanobacteria. Some Cyanobacterial species release toxins that can reach humans through drinking water, fish consumption, and direct contact with contaminated water. The lake has been historically popular for fishing and water sports, and its overflow water drains into the Hillsborough River, the main supply of municipal water for the City of Tampa, this explains why it has being constantly monitored in situ for water quality by the Environmental Protection Commission of Hillsborough County (EPC). Advances in remote sensing technology, however, open the possibility of facilitating similar types of monitoring in this and similar lakes, further contributing to the implementation of surveillance systems that would benefit not just public health, but also tourism and ecosystems. Although traditional application of this technology to water quality has been focused on much larger coastal water bodies like bays and estuaries, this study evaluates the feasibility of its application on a 46.6 km2 freshwater lake. Using surface reflectance products from Moderate-Resolution Imaging Spectroradiometer (MODIS) Terra, this study evaluates associations between remotely sensed data and in situ data from the EPC. The parameters analyzed are the surface water quality standards used by the State of Florida and general indicators of trophic status.

Moreno, Max J.↗

Gateway Cities Unplugged: (em)Powering Affordable Housing (Final Technical Report)

The Gateway Cities Unplugged: (em)Powering Affordable Housing (the “Project”) was launched to address a critical challenge in the U.S. building and energy sectors: enabling multifamily buildings especially those serving low and moderate‑income (LMI) communities to actively support grid modernization through Grid‑Interactive Efficient Buildings (GEB). Multifamily housing represents a large share of national building energy consumption, yet the sector faces persistent barriers to adopting advanced load flexibility technologies, including capital constraints, aging infrastructure, and limited access to demand‑side management tools. This Project sought to overcome those barriers by defining, evaluating, and designing commercially viable GEB technology packages for six representative multifamily properties across Massachusetts, Connecticut, and New York.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public health applications of remote sensing of the environment, an evaluation

The available techniques were examined in the field of remote sensing (including aerial photography, infrared detection, radar, etc.) and applications to a number of problems in the wide field of public health determined. The specific areas of public health examined included: air pollution, water pollution, communicable disease, and the combined problems of urban growth and the effect of disasters on human communities. The assessment of the possible applications of remote sensing to these problems was made primarily by examination of the available literature in each field, and by interviews with health authorities, physicists, biologists, and other interested workers. Three types of programs employing remote sensors were outlined in the air pollution field: (1) proving ability of sensors to monitor pollutants at three levels of interest - point source, ambient levels in cities, and global patterns; (2) detection of effects of pollutants on the environment at local and global levels; and (3) routine monitoring.

Source record↗

Strategies to mitigate urban heat: Effects on overheating and cloud formation

This study evaluates the effectiveness of various urban heat island (UHI) overheating mitigation strategies and their associated impacts on urban cloud dynamics and thermal processes. This study shows cloud-resolving and urban-resolving modeling results estimating the impact of Houston-Galveston heat mitigation scenarios and other resilient strategies contemplated in the Climate Adaptation Plan and Resilient Houston reports. The simulated scenarios include high intensity green rooftops, rooftop photovoltaic solar panels, enhanced urban irrigation, white/cool roofs and roads, and street trees. We contrast the adaptation scenarios against a present baseline case, a no city scenario and a larger and denser city as projected by the Houston-Galveston Area Council for 2045. During the daytime, cooling strategies such as cool roofs, cool roads, and green roofs exhibit superior performance in mitigating urban overheating. At night, enhanced urban irrigation emerges as the most effective cooling intervention. Cooling strategies significantly reduce sensible heat flux partitioning during the day, a process that reduces the uplift of air, suppressing the formation of urban shallow cumulus clouds. The extent of urban cloud mixing ratio is reduced in proportion to the decrease in sensible heating. Under the BEP-Tree scenario, which includes wind effects and evapotranspiration driven by a stomatal conductance model, urban trees demonstrated negligible environmental cooling effects and minimal urban cloud modifications. In contrast, the scenarios with more urban cooling and higher latent heat fluxes led to suppressed urban clouds. The net cooling effect achieved by the heat mitigation strategies is influenced by a combination of indirect processes, including the reduction of downwelling longwave radiation flux, due to reduced cloud presence, while some warming is attributed to a modest increase in shortwave radiation that offsets the cooling benefit. Additionally, reduced heat dissipation, weakened thermal gradients, and diminished vertical mixing over urban areas further moderate the cooling potential. These findings highlight the pivotal role of clouds and moist atmospheric processes in shaping the UHI effect and offer insights for designing more effective urban cooling strategies.

albedo changes↗

Flight test and evaluation of Omega navigation in a general aviation aircraft. Volume 1: Technical

A low cost flight research program was conducted to evaluate the performance of differential Omega navigation in a general aviation aircraft. The flight program consisted of two distinct parts corresponding to the two major objectives of the study. The Wallops Flight Program was conducted to obtain Omega signal and phase data in the Wallops Flight Center vicinity to provide preliminary technical information and experience in preparation for a comprehensive NASA/FAA flight test program of an experimental differential Omega system. The Northeast Corridor Flight Program was conducted to examine Omega operational suitability and performance on low altitude area navigation (RNAV) routes for city-center to city-center VTOL commercial operations in the Boston-New York-Washington corridor. The development, execution and conclusions of the flight research program are discribed. The results of the study provide both quantitative and qualitative data on the Omega Navigation System under actual operating conditions.

Howell, J. D.↗

Evaluating Acoustic vs. AI-Based Satellite Leak Detection in Aging US Water Infrastructure: A Cost and Energy Savings Analysis

The aging water distribution system in the United States, constructed mainly during the 1970s with some pipes dating back 125 years, is experiencing significant deterioration leading to substantial water losses. Along with the potential for water loss savings, improvements in the distribution system by using leak detection technologies can create net energy and cost savings. In this work, a new framework has been presented to calculate the economic level of leakage within water supply and distribution systems for two primary leak detection technologies (acoustic vs. satellite). In this work, a new framework is presented to calculate the economic level of leakage (ELL) within water supply and distribution systems to support smart infrastructure in smart cities. A case study focused using water audit data from Atlanta, Georgia, compared the costs of two leak mitigation technologies: conventional acoustic leak detection and artificial intelligence–assisted satellite leak detection technology, which employs machine learning algorithms to identify potential leak signatures from satellite imagery. The ELL results revealed that conducting one survey would be optimum for an acoustic survey, whereas the method suggested that it would be expensive to utilize satellite-based leak detection technology. However, results for cumulative financial analysis over a 3-year period for both technologies revealed both to be economically favorable with conventional acoustic leak detection technology generating higher net economic benefits of USD 2.4 million, surpassing satellite detection by 50%. A broader national analysis was conducted to explore the potential benefits of US water infrastructure mirroring the exemplary conditions of Germany and The Netherlands. Achieving similar infrastructure leakage index (ILI) values could result in annual cost savings of $\$4$–$\$4.8$ billion and primary energy savings of 1.6–1.9 TWh. These results demonstrate the value of combining economic modeling with advanced leak detection technologies to support sustainable, cost-efficient water infrastructure strategies in urban environments, contributing to more sustainable smart living outcomes.

acoustic leak detection↗

A Comparative Analysis of Infrastructure-Based Perception Sensors for Intelligent Transportation Systems

The rise of privatized and public investment in smart city infrastructure and intelligent transportation systems has generated a heightened demand for perception sensors that effectively track and detect objects while being reliable in diverse weather and lighting conditions. This growing demand for perception sensors has accelerated their development and enhanced their capabilities. With these new capabilities, it is challenging to determine the most suitable sensing unit to use in each situation. Therefore, it is essential to have a comprehensive understanding of the benefits and limitations of each sensing unit to effectively leverage their capabilities. The purpose of this paper is to provide a detailed evaluation of various perception sensors. Additionally, this paper will demonstrate the benefits of combining multiple perception sensors, which complement each other by addressing data gaps inherent to single-sensor systems, to facilitate the creation of a digital twin that models the real world. The Infrastructure, Perception, and Control (IPC) team will conduct data analysis using data collected through field testing at traffic intersections in Colorado Springs, Colorado, to make comparisons between sensors. This research aims to provide clear and concise information about modern perception systems, which will support the development of intelligent transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

Communicating Respiratory Health Risk Among Children using a Global Air Quality Index

Air pollution poses a serious threat to children’s respiratory health around the world. Satellite remote-sensing technology and air quality models can provide pollution data on a global scale, necessary for riskcommunication efforts in regions without ground-based monitoring networks. Several large centers, including NASA, produce global pollution forecasts that may be used alongside air quality indices to communicate local, daily risk information to the public. Here we present a health-based, globally applicable air quality index developed specifically to reflect the respiratory health risks among children exposed to elevated outdoor air pollution. Additive, excess-risk air quality indices were developed using 51 different coefficients derived from time-series health studies evaluating the impacts of ambient fine particulate matter, nitrogen dioxide, and ozone on children's respiratory morbidity outcomes. A total of four indices were created which varied based on whether or not the underlying studies controlled for co-pollutants and in the adjustment of excess risks of individual pollutants. Combined with historical estimates of air pollution provided globally at a 25x25 km2 spatial resolution from the NASA's Goddard Earth Observing System composition forecast (GEOS-CF) model, each of these indices were examined in a global sample of 664 small and 140 large cities for study year 2017. Adjusted indices presented the most normal distributions of locally-scaled index values, which has been shown to improve associations with health risks, while indices based on coefficients controlling for co-pollutants had little effect on index performance. We provide the steps and resources need to apply our final adjusted index at the local level using freely-available forecasting data from the GEOS-CF model, which can provide risk communication information for cities around the world to better inform individual behavior modification to best protect children's respiratory health.

Air Qualilty↗

Partial melting of the St. Severin (LL) and Lost City (H) ordinary chondrites: One step backwards and two steps forward

This study looks at partial melting in H and LL chondrites at nearly one atmosphere of total pressure as part of a continuing study of the origins of basaltic achondrites. Previously, melting experiments on anhydrous CM and CV chondrites showed that, near its solidus, the CM chondrite produced melts having major element chemistries similar to the Sioux County eucrite; but, the pyroxenes in the residuum were too iron-rich to form diogenites. Our preliminary results from melting experiments on ordinary (H, LL) chondrites suggested that, although the melts did not look like any known eucrites, pyroxenes from these charges bracketed the compositional range of pyroxenes found in diogenites. We had used the Fe/Mg exchange coefficients calculated for olivine, pyroxene, and melt in these charges to evaluate the approach to equilibrium, which appeared to be excellent. Unfortunately, mass balance calculations later indicated to us that, unlike our CM and CV charges, the LL and H experimental charges had lost significant amounts of iron to their (Pt or PtRh) supports. Apparently, pyroxene stability in chondritic systems is quite sensitive to the amount of FeO, and it was this unrecognized change in the bulk iron content which had stabilized the high temperature, highly magnesian pyroxenes. Accordingly, this work reinvestigates the phase equilibria of ordinary chondrites, eliminating iron and nickel loss, and reports significant differences. It also looks closely at how the iron and sodium in the bulk charge affect the stability of pyroxene, and it comments on how these new results apply to the problems of diogenite and eucrite petrogenesis.

Jurewicz, A. J. G.↗

The Response of Summertime Organic Aerosol Composition to Emission Controls in the Northeastern United States

The responses of secondary organic aerosols (SOA) to emission controls remain uncertain due to the limited continuous long‐term measurements. Measurements of detailed carbonaceous aerosol composition in the New York City metropolitan region during the summers of 2001, 2009, 2011, and 2018 provide a look at the changes in summertime SOA over the past two decades when significant pollution reduction and emission controls occurred in the northeastern United States. Here, we show that the averaged nighttime SOA, especially the fresh local SOA, extreme mass concentrations resulted from anthropogenic volatile organic compounds reductions, while there is a little trend for the regional aged SOA. Meanwhile, these fresh SOA extremes occurred most often under conditions of high relative humidity during nighttime. The analysis presented here provides a comprehensive evaluation of the evolution of the increasingly important organic component of the submicron ambient aerosols in this major metropolitan area.

Zhang, Jie↗