Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “characterizations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design and characterization of the time-resolved opacity spectrometer (OpSpecTR) for the NIF iron opacity campaign

A new time-resolved opacity spectrometer (OpSpecTR) is currently under development for the National Ignition Facility (NIF) opacity campaign. Here, the spectrometer utilizes Icarus version 2 (IV2) hybridized complementary metal–oxide–semiconductor sensors to collect gated data at the time of the opacity transmission signal, unlocking the ability to collect higher-temperature measurements on NIF. Experimental conditions to achieve higher temperatures are feasible; however, backgrounds will dominate the data collected by the current time-integrating opacity spectrometer. The shortest available OpSpecTR integration time of ~2 ns is predicted to reduce self-emission and other late-time backgrounds by up to 80%. Initially, three Icarus sensors will be used to collect data in the self-emission, backlighter, and absorption regions of the transmission spectrum, with plans to upgrade to five Daedalus sensors in future implementations with integration times of ~1.3 ns. We present the details of the diagnostic design along with recent characterization results of the IV2 sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and characterization of a solar-enhanced microwave plasma reactor for atmospheric pressure carbon dioxide decomposition

The decomposition of carbon dioxide (CO 2 ) is a main step in carbon re-utilization approaches aimed to fulfill fuels and chemicals demands and mitigate environmental emissions. Plasmachemical CO 2 decomposition processes can be highly efficient; however, their reliance on electrical energy can limit their economic viability and sustainability advantage. In contrast, solar thermochemical CO 2 decomposition approaches can have limited efficiency, but their direct use of the most abundant form of renewable energy affords them the greatest sustainability potential. Solar-Enhanced Microwave Plasma (SEMP) chemical synthesis, based on the direct interaction between microwave plasma and concentrated solar radiation, is investigated as a novel approach to combine the advantages of plasmachemical and solar thermochemical processes. SEMP is motivated by the potential for synergistic effects between solar photons and plasma species, implied by the markedly greater spectral absorption of nonequilibrium CO 2 plasma compared to that of equilibrium CO 2 , to lead to enhanced chemical decomposition. The design, development, and characterization of a SEMP reactor for atmospheric pressure CO 2 decomposition is presented. The reactor is powered by a 1.25 kW magnetron and by up to 525 W of incident radiative power from a high-flux solar simulator. Experimental results reveal that the microwave plasma absorbs up to 20% of concentrated solar radiation at a solar-to-electrical power ratio of 0.5, and that relative absorption decreases with increasing solar input power. Yet, conversion efficiency and plasma energy efficiency increase with increasing solar power, up to 9% and 25% respectively, for a solar-to-electrical power ratio of 0.75. The enhanced process performance appears to be a consequence of the greater power density in the plasma caused by the direct absorption of solar radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cosmic-muon characterization and annual modulation measurement with Double Chooz detectors

A study on cosmic muons has been performed for the two identical near and far neutrino detectors of the Double Chooz experiment, placed at ∼120 and ∼300 m.w.e. underground respectively, including the corresponding simulations using the MUSIC simulation package. This characterization has allowed us to measure the muon flux reaching both detectors to be (3.64 ± 0.04) × 10{sup −4} cm{sup −2}s{sup −1} for the near detector and (7.00 ± 0.05) × 10{sup −5} cm{sup −2}s{sup −1} for the far one. The seasonal modulation of the signal has also been studied observing a positive correlation with the atmospheric temperature, leading to an effective temperature coefficient of α {sub T} = 0.212 ± 0.024 and 0.355 ± 0.019 for the near and far detectors respectively. These measurements, in good agreement with expectations based on theoretical models, represent one of the first measurements of this coefficient in shallow depth installations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Holistic scan optimization of nacelle-mounted lidars for inflow and wake characterization at the RAAW and AWAKEN field campaigns

In this article, we provide a methodological framework for designing the scanning strategies of nacelle-mounted scanning lidars for wind energy field experiments, and apply it at two major experimental field campaigns. For the Rotor Aerodynamics, Aeroelastics, and Wake project (RAAW), we leverage two scanning lidars on one turbine to characterize the incoming turbulence and the turbine wake. For the American WAKE experimeNt (AWAKEN), we use four scanning lidars on top of four turbines in a large wind power plant to investigate both individual wakes and wind-plant-scale flow features.

17 WIND ENERGY↗

Femtosecond X-ray Pulse Temporal Characterization in Free-Electron Lasers Using a Transverse Deflector

We propose a novel method to characterize the temporal duration and shape of femtosecond x-ray pulses in a free-electron laser (FEL) by measuring the time-resolved electron-beam energy loss and energy spread induced by the FEL process, with a transverse radio-frequency deflector located after the undulator. Its merits are simplicity, high resolution, wide diagnostic range, and non-invasive to user operation. When the system is applied to the Linac Coherent Light Source, the first hard x-ray free-electron laser in the world, it can provide single-shot measurements on the electron beam and x-ray pulses with a resolution on the order of 1-2 femtoseconds rms.

43 PARTICLE ACCELERATORS↗

Structural characterization of CalO1: a putative orsellinic acid methyltransferase in the calicheamicin-biosynthetic pathway

The X-ray structure determination at 2.4 {angstrom} resolution of the putative orsellinic acid C3 O-methyltransferase (CalO1) involved in calicheamicin biosynthesis is reported. Comparison of CalO1 with a homology model of the functionally related calicheamicin orsellinic acid C2 O-methyltransferase (CalO6) implicates several residues that are likely to contribute to the regiospecificity of alkylation. Consistent with the proposed requirement of an acyl-carrier-protein-bound substrate, this structural study also reveals structural determinants within CalO1 that are anticipated to accommodate an association with an acyl carrier protein.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Performance and Reliability Characterization of Bonded Interface Materials (BIMs): Preprint

Thermal interface materials are an important enabler for low thermal resistance and reliable electronics packaging for a wide array of applications. There is a trend towards bonded interface materials (BIMs) because of their potential for low thermal resistivity (< 1 mm2K/W). However, BIMs induce thermomechanical stresses in the package and can be prone to failures and integrity risks. Deteriorated interfaces can result in high thermal resistance in the package and degradation and/or failure of the electronics. DARPA's Thermal Management Technologies program has addressed this challenge, supporting the development of mechanically-compliant, low resistivity nano-thermal interface (NTI) materials. In this work, we describe the testing procedure and report the results of NREL's thermal performance and reliability characterization of an initial sample of four different NTI-BIMs.

30 DIRECT ENERGY CONVERSION↗

Characterization of Epitaxial Film Silicon Solar Cells Grown on Seeded Display Glass: Preprint

We report characterizations of epitaxial film crystal silicon (c-Si) solar cells with open-circuit voltages (Voc) above 560 mV. The 2-um absorber cells are grown by low-temperature (<750 degrees C) hot-wire CVD (HWCVD) on Corning EAGLE XG display glass coated with a layer-transferred (LT) Si seed. The high Voc is a result of low-defect epitaxial Si (epi-Si) growth and effective hydrogenpassivation of defects. The quality of HWCVD epitaxial growth on seeded glass substrates depends on the crystallographic quality of the seed and the morphology of the epitaxial growth surface. Heterojunction devices consist of glass/c-Si LT seed/ epi n+ Si:P/epi n- Si:P/intrinsic a-Si:H/p+ a-Si:H/ITO. Similar devices grown on electronically 'dead' n+ wafers have given Voc630 mV and8%efficiency with no light trapping features. Here we study the effects of the seed surface polish on epi-Si quality, how hydrogenation influences the device character, and the dominant junction transport physics.

14 SOLAR ENERGY↗

Characterization and Modeling of 4H-SiC Lateral MOSFETs for Integrated Circuit Design

A new process in 4H-SiC is developed that features n-type buried and inversion channel lateral MOSFETs that are fabricated with several different channel lengths (2-8 mu m) and widths (8-32 mu m) and characterized over a wide temperature range (25 degrees C-225 degrees C). It is shown that the on-resistance of enhancement-mode SiC MOSFETs reduces with temperature despite a reduction in inversion mobility because of the interaction of interface states with temperature. To enable integrated circuit development using the developed MOSFETs, their electrical characteristics are modeled over geometry and temperature using the industry standard PSP MOSFET model. A new mathematical formulation to describe the presence of the interface states is also developed and implemented in the PSP model, and excellent agreement is shown between measurement and simulation using the modified PSP model.

Mudholkar, M↗

Synthesis and characterization of iodosodalite

Abstract The effects of six process variables were investigated on the hydrothermal growth of iodosodalite, Na 8 Al 6 Si 6 O 24 I 2 : pH (Na OH concentration), aging time, temperature, Al/Si ratio, precursors used (i.e., zeolite 4A, kaolinite, meta‐kaolin, colloidal silica, and sodium aluminate), and precursor concentration. Powder X‐ray diffraction ( XRD ) with Rietveld refinements, X‐ray photoelectron spectroscopy ( XPS ), Fourier transform infrared spectroscopy ( FTIR ), and scanning electron microscopy ( SEM ) were performed to characterize the structures, phase fractions, chemical state, and surface morphology of the synthesized products. Iodosodalite yield increased as aging time and pH increased. The crystallization of iodosodalite was favored in the temperature range 140°C‐180°C. Decreasing the Al/Si ratio by half increased the crystallization of basic cancrinite. Lowering the precursor concentration by adding water revealed the crystallization of nepheline hydrate I and a decrease in the sodalite fraction. Among the tested precursors, zeolite 4A yielded the highest mass fraction of iodosodalite in the synthesized powders. From the aging time and temperature variation experiments, the phase transformation of zeolite A→sodalite→cancrinite was observed. XPS and FTIR results showed the presence of only iodide but not iodate in the synthesized product. The crystallization of various minerals suggests that mechanisms for transport of the ions and formation of the aluminosilicate frameworks vary with hydrothermal conditions.

Chong, Saehwa↗

Design and characterization of the SPT-3G receiver (Conference Presentation)

(On behalf of the SPT-3G collaboration)The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map the Cosmic Microwave Background (CMB) with arcminute resolution. The new instrument significantly improves on previous SPT camera designs, offering unprecedented sensitivity to the CMB’s temperature and polarization anisotropies while maintaining a tight control on systematic effects.A restructured optics chain features new secondary and tertiary mirrors to increase the receiver’s field of view by a factor of four in area, coupling light through a set of four cryogenic 720 mm alumina elements, which re-image the Gregorian focus inside the receiver. The broad-band (70-270 GHz) anti-reflective coated lenses are paired with a Lyot stop and cooled to 4 K using a dedicated two-stage pulse-tube cooler (PTC) to minimize in-band attenuation, internal radiative loading, and stray light on the considerably larger focal plane, which is populated with ~2,700 diffraction-limited pixels.Each independent pixel incorporates a lenslet-coupled broadband sinuous antenna, which routes signals through superconducting transmission lines and in-line band-defining filters to six transition-edge sensors, each measuring one of three bands (90, 150, and 220 GHz) and two polarizations, yielding a total of ~16,000 bolometers distributed across ten 150 mm monolithic wafers on a 430 mm image plane. A robust mechanical and thermal architecture supports and cools all detectors across this sizable focal plane to ~250 mK using a closed-cycle Helium adsorption refrigerator backed by a PTC, allowing a duty cycle greater than 90%.This order of magnitude increase in detector count relies on an improved digital frequency-domain SQUID readout system which integrates superconducting inductor-capacitor resonators wired in series with each bolometer to achieve a 68x multiplexing factor while mitigating noise and crosstalk effects.Cumulatively, SPT-3G’s new optics, detector, and readout strategies boast a potential factor of ~20 improvement in mapping speed over its predecessor, SPT-Pol, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We summarize the new receiver’s core design principles, outline technology characterization results, and report on plans for future upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗