Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The San Fernando Observatory video Stokes polarimeter

A study was conducted to determine the suitability of the San Fernando Observatory's 61 cm (24 inch) aperture vacuum solar telescope and 3 m (118 inch) focal length vacuum spectroheliograph for Stokes Polarimetry measurements. The polarization characteristics of these two instruments was measured by determining their Mueller matrices as a function of telescope orientation, field angle, wavelength, grating type, and position of the measuring beam in the telescope entrance window. In general, the polarizing and depolarizing properties are small so that inversion of the system Mueller matrix will permit the accurate measurement of Stokes profiles for vector magnetic field determination. A proposed polarimeter design based on the use of a TV camera system to simultaneously scan six different polarization components of a given line profile is described. This design, which uses no rotating optics or electronic modulators and makes efficient use of the available irradiance, promises to yield high quality vector magnetograms.

Richter, P. H.↗

The Visible Imaging System (VIS) for the Polar Spacecraft

The Visible Imaging System (VIS) is a set of three low-light-level cameras to be flown on the POLAR spacecraft of the Global Geospace Science (GGS) program which is an element of the International Solar-Terrestrial Physics (ISTP) campaign. Two of these cameras share primary and some secondary optics and are designed to provide images of the nighttime auroral oval at visible wavelengths. A third camera is used to monitor the directions of the fields-of-view of these sensitive auroral cameras with respect to sunlit Earth. The auroral emissions of interest include those from N+2 at 391.4 nm, 0 I at 557.7 and 630.0 nm, H I at 656.3 nm, and 0 II at 732.0 nm. The two auroral cameras have different spatial resolutions. These resolutions are about 10 and 20 km from a spacecraft altitude of 8 R(sub e). The time to acquire and telemeter a 256 x 256-pixel image is about 12 s. The primary scientific objectives of this imaging instrumentation, together with the in-situ observations from the ensemble of ISTP spacecraft, are (1) quantitative assessment of the dissipation of magnetospheric energy into the auroral ionosphere, (2) an instantaneous reference system for the in-situ measurements, (3) development of a substantial model for energy flow within the magnetosphere, (4) investigation of the topology of the magnetosphere, and (5) delineation of the responses of the magnetosphere to substorms and variable solar wind conditions.

Frank, L. A.↗

Thermal Development of a Commercial off the Shelf (COTS) Camera for Exploration Upper Stage (EUS)

NASA’s Flight Imagery Launch Monitoring Real-time System (FILMRS) cameras were originally developed for the Space Launch System (SLS) Core Stage. These Commercial Off the Shelf (COTS) cameras have been redesigned and reduced by an order of magnitude in size for the Exploration Upper Stage (EUS). The change in thermal environment has led to the application of various passive thermal control methods and the addition of a heater option. This paper will give a summary of the design and development test effort associated with adapting the COTS camera for the demands of the space environment and associated thermal mitigations applied as the project prepares to complete the design. The application of this camera for other space systems is discussed.

Hernandez, Deborah↗

Design of Electrostatic Dust Lofting Suborbital Flight Experiment Examining Photoionization under Lunar Gravity

Dust on the lunar surface electrostatically charges due to the plasma environment surrounding the Moon, causing grains to become lofted and adhere to nearby surfaces including landers and astronauts. Studying the behaviors of these charged particles in the lunar environment is essential to plan around the deleterious effects of dust to future Moon missions. Models attempt to predict the amount of dust loading that can be expected in many of these scenarios, but they require experimental validation to be predictive. This physics cannot be fully studied on Earth due to the six times larger gravitational force obscuring the electrostatic interactions, so it is necessary to run experiments in a more relevant environment, including vacuum and near-lunar gravitational effects. An experiment has been designed to fly on the Lunar Gravity Acceleration (LGA) mission aboard the Blue Origin New Shepard suborbital rocket. This experiment will perform photoionization charging of lunar regolith simulant grains under the illumination of an ultraviolet (UV) source. As a result, the charged grains will then electrostatically repel one another and loft in the reduced gravity environment; their trajectories will be imaged via a high-speed camera. Preliminary laboratory results influencing the design of this experiment will be presented, including characterization of several UV sources, measurements of photoionization currents under various vacuum conditions, and examination of lunar simulant dust lofting under terrestrial gravity. Results from this flight will be compared with ground-based testing and the laboratory results outlined above to examine the dependence on gravity and will be fed into the dust charging and lofting models currently under development.

electrostatics↗

The Mars facsimile camera.

Panoramic facsimile camera providing IR and visible spectrum imagery designed for unmanned space operation, noting construction, weight, etc

FACSIMILE TRANSMISSION↗

Design of the Skylab MDA window

Description of the optical and structural design requirements, mechanical and thermal response analyses, final design features, and testing procedures employed in the development of a large window mounted on the earth-facing side of the multiple docking adapter (MDA) of the Skylab manned space vehicle. This window was designed for the S190 earth resources multispectral camera and was protected from the space environment during nonuse periods by a hinged cover operated from within the MDA. The camera required a viewing area approximately 43 by 58 cm. A single glass pane 4.1 cm thick was selected to minimize optical distortions. Heaters on the glass and frame were designed to control distortions caused by thermal gradients in the glass.

Trent, D. J.↗

Design of a neutron microscope based on Wolter mirrors

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. Here, this is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (10 4 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Low-Cost, Submersible, Digital Holographic Microscope for in Situ Microbial Imaging

The methodologies for studying marine microbiology typically consist of utilizing instrumentation within a laboratory. This typically requires extracting a sample from its place of origin prior to examination, which may be days after collection. Oftentimes, the solution is to bring the lab to the ocean, which may be costly and provide further limitations for a sterile and stable laboratory environment. Here we present a low-cost, submersible, digital holographic microscope (DHM) designed to image marine microorganisms (such as bacteria and plankton) in their natural underwater environment. Our instrument eliminates the need to transport samples and allows for instantaneous data collection of microbes in-situ. The DHM achieves sub-micron spatial resolution and is paired with artificial intelligence for the detection and tracking of specimens to reduce the overall collected data. This instrument also aims to reduce the cost of manufacturing and field expenses relative to marine microbiological research. “Off the shelf” components were selected in the design process of this instrument which allows us to achieve precise results without sacrificing data quality. The DHM itself costs under one thousand dollars and features a low-cost high-resolution camera, the Arducam MT9J001. Included in the design were five main subsystems: optical, mechanical, electrical, power, and machine learning. Our on board computer and artificial intelligence consist of a Raspberry Pi 4 (8 Gb) and Google Coral USB Tensorflow accelerator. Instrument testing has successfully proven our abilities of data acquisition for at least two hours in depths of at least forty meters below sea level. Additionally, our artificial intelligence system is currently capable of tracking up to ten areas of interest in a fraction of a second with over ninety percent confidence via the neural net driven by the tensor cores on the Google Coral. Furthermore, we have demonstrated the versatility of our instrument by mounting it on an ocean-going ROV, the BlueRov2 by BlueRobotics. Our tests on the BlueRov2 exemplified the cost-effective nature of a submersible and reusable instrument that can be implemented in moderate environments and on most vessels.

Wallace, James Kent↗

Mars Cameras Make Panoramic Photography a Snap

If you wish to explore a Martian landscape without leaving your armchair, a few simple clicks around the NASA Web site will lead you to panoramic photographs taken from the Mars Exploration Rovers, Spirit and Opportunity. Many of the technologies that enable this spectacular Mars photography have also inspired advancements in photography here on Earth, including the panoramic camera (Pancam) and its housing assembly, designed by the Jet Propulsion Laboratory and Cornell University for the Mars missions. Mounted atop each rover, the Pancam mast assembly (PMA) can tilt a full 180 degrees and swivel 360 degrees, allowing for a complete, highly detailed view of the Martian landscape. The rover Pancams take small, 1 megapixel (1 million pixel) digital photographs, which are stitched together into large panoramas that sometimes measure 4 by 24 megapixels. The Pancam software performs some image correction and stitching after the photographs are transmitted back to Earth. Different lens filters and a spectrometer also assist scientists in their analyses of infrared radiation from the objects in the photographs. These photographs from Mars spurred developers to begin thinking in terms of larger and higher quality images: super-sized digital pictures, or gigapixels, which are images composed of 1 billion or more pixels. Gigapixel images are more than 200 times the size captured by today s standard 4 megapixel digital camera. Although originally created for the Mars missions, the detail provided by these large photographs allows for many purposes, not all of which are limited to extraterrestrial photography.

Source record↗

TV system considerations for the Space Telescope

The Space Telescope, designed as a permanent observatory in space, will be launched into orbit, maintained, and refurbished by the Space Shuttle. One of the primary instruments to fly with the telescope is the f/24 Camera. The camera's mission requirements and their impact on the choice and design of a television system are discussed, along with the system engineering aspects of the TV system design and spacecraft design. An SEC type television camera tube was selected as the primary data acquisition sensor, because of its ability to accommodate exposure times of several hours with only modest cooling.

Lowrance, J. L.↗

The facsimile camera - Its potential as a planetary lander imaging system.

Review of the performance characteristics of the facsimile camera, emphasizing its line-scan sampling process; the design tradeoffs which are imposed by planetary lander missions, emphasizing those tradeoffs which define the Viking Lander Camera parameters; and new concepts which are currently being investigated for future planetary lander missions, emphasizing an integrated imagery and spectrometry concept.

Huck, F. O.↗

An Acoustic Charge Transport Imager for High Definition Television

This project, over its term, included funding to a variety of companies and organizations. In addition to Georgia Tech these included Florida Atlantic University with Dr. William E. Glenn as the P.I., Kodak with Mr. Mike Richardson as the P.I. and M.I.T./Polaroid with Dr. Richard Solomon as the P.I. The focus of the work conducted by these organizations was the development of camera hardware for High Definition Television (HDTV). The focus of the research at Georgia Tech was the development of new semiconductor technology to achieve a next generation solid state imager chip that would operate at a high frame rate (I 70 frames per second), operate at low light levels (via the use of avalanche photodiodes as the detector element) and contain 2 million pixels. The actual cost required to create this new semiconductor technology was probably at least 5 or 6 times the investment made under this program and hence we fell short of achieving this rather grand goal. We did, however, produce a number of spin-off technologies as a result of our efforts. These include, among others, improved avalanche photodiode structures, significant advancement of the state of understanding of ZnO/GaAs structures and significant contributions to the analysis of general GaAs semiconductor devices and the design of Surface Acoustic Wave resonator filters for wireless communication. More of these will be described in the report. The work conducted at the partner sites resulted in the development of 4 prototype HDTV cameras. The HDTV camera developed by Kodak uses the Kodak KAI-2091M high- definition monochrome image sensor. This progressively-scanned charge-coupled device (CCD) can operate at video frame rates and has 9 gm square pixels. The photosensitive area has a 16:9 aspect ratio and is consistent with the "Common Image Format" (CIF). It features an active image area of 1928 horizontal by 1084 vertical pixels and has a 55% fill factor. The camera is designed to operate in continuous mode with an output data rate of 5MHz, which gives a maximum frame rate of 4 frames per second. The MIT/Polaroid group developed two cameras under this program. The cameras have effectively four times the current video spatial resolution and at 60 frames per second are double the normal video frame rate.

Hunt, William D.↗

Surveyor television mechanisms

Design specifications for Surveyor Spacecraft television camera mechanisms, and operating conditions in lunar environment

EQUIPMENT SPECIFICATIONS↗

Design and evaluation of controls for drift, video gain, and color balance in spaceborne facsimile cameras

The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.

Katzberg, S. J.↗

Preliminary results from a single-photon imaging X-ray charge coupled device /CCD/ camera

A CCD camera is described which has been designed for single-photon X-ray imaging in the 1-10 keV energy range. Preliminary results are presented from the front-side illuminated Fairchild CCD 211, which has been shown to image well at 3 keV. The problem of charge-spreading above 4 keV is discussed by analogy with a similar problem at infrared wavelengths. The total system noise is discussed and compared with values obtained by other CCD users.

Griffiths, R. E.↗

Wide-Field, Two-Stage Optical System

Proposed telescope offers wide field of view, yet relatively inexpensive to manufacture. Design, in form of three Schmidt cameras, offers 10-degree strip field of view, single large-diameter collecting aperture, four spherical mirrors, and two diamond-turned aspheric mirrors in relatively compact configuration. Transference of large-diameter Schmidt corrector plate to smaller element makes this wide-field optical system suitable for application of two-stage optics theory. Concept enables cost-effective implementation of large-diameter optics by relaxing fabrication requirements.

Manhart, Paul K.↗

Determination of Shed Ice Particle Size Using High Speed Digital Imaging

A full scale model of an aircraft engine inlet was tested at NASA Lewis Research Center's Icing Research Tunnel. Simulated natural ice sheds from the engine inlet lip were studied using high speed digital image acquisition and image analysis. Strategic camera placement integrated at the model design phase allowed the study of ice accretion on the inlet lip and the resulting shed ice particles at the aerodynamic interface plane at the rear of the inlet prior to engine ingestion. The resulting digital images were analyzed using commercial and proprietary software to determine the size of the ice particles that could potentially be ingested by the engine during a natural shedding event. A methodology was developed to calibrate the imaging system and insure consistent and accurate measurements of the ice particles for a wide range of icing conditions.

Broughton, Howard↗