Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Perspectives on the Calibration of CNN Energy Reconstruction in Highly Granular Calorimeters

We present a study which shows encouraging stability of the response linearity for a simulated high granularity calorimeter module reconstructed by a CNN model to miscalibration, bias, and noise effects. Our results also show an intuitive, quantifiable relationship between these factors and the calibration parameters. We trained a CNN model to reconstruct energy in the calorimeter module using simulated single-pion events; we then observed the response of the model under various miscalibration, bias, and noise conditions that affected the model input. From these data, we estimated linear response models to calibrate the CNN. We also quantified the relationship between these factors and the calibration parameters by regression analysis.

Akchurin, Nural↗

Gaussian process for calibration and control of GlueX Central Drift Chamber

We have developed and implemented a machine learning based system to calibrate and control the GlueX Central Drift Chamber at Jefferson Lab, VA, in near real-time. The system monitors environmental and experimental conditions during data taking and uses those as inputs to a Gaussian process (GP) with learned prior. The GP predicts calibration constants in order to recommend a high voltage (HV) setting for the detector that maintains consistent detector performance (gain and resolution) throughout data taking. This approach is in stark contrast to traditional detector operations in which the detector operates at fixed HV and its calibration parameters vary quite considerably with time. Additionally, the ML based system utilizes uncertainty quantification to correct the recommended control parameters when appropriate. We will present results from the ML system autonomously during the Charged Pion Polarizability (CPP) experiment conducted in Hall D at Jefferson Lab.

McSpadden, Helen↗

Calibration of the analog beam-signal hardware for the credited engineered beam power limit system at the Proton Power Upgrade Project at the Spallation Neutron Source

A programmable signal processor-based credited safety control that calculates pulsed beam power based on beam kinetic energy and charge was designed as part of the Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS). The system must reliably shut off the beam if the average power exceeds 2.145 MW averaging over 60 seconds. System calibration requires pedigree in measurements, calibration setup, and calculations. This paper discusses the calibration of the analog beam signal components up to and including the Analog Digital Convertors (ADCs) for implementation into the Safety Programmable Logic Controllers (PLCs) and Field Programmable Gate Arrays (FPGAs).

Bobrek, Miljko↗

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Energy Survey Year 6 Results: Redshift Calibration of the MagLim++ Lens Sample

In this work, we derive and calibrate the redshift distribution of the MagLim++ lens galaxy sample used in the Dark Energy Survey Year 6 (DES Y6) 3x2pt cosmology analysis. The 3x2pt analysis combines galaxy clustering from the lens galaxy sample and weak gravitational lensing. The redshift distributions are inferred using the SOMPZ method - a Self-Organizing Map framework that combines deep-field multi-band photometry, wide-field data, and a synthetic source injection (Balrog) catalog. Key improvements over the DES Year 3 (Y3) calibration include a noise-weighted SOM metric, an expanded Balrog catalogue, and an improved scheme for propagating systematic uncertainties, which allows us to generate O($10^8$) redshift realizations that collectively span the dominant sources of uncertainty. These realizations are then combined with independent clustering-redshift measurements via importance sampling. The resulting calibration achieves typical uncertainties on the mean redshift of 1-2%, corresponding to a 20-30% average reduction relative to DES Y3. We compress the $n(z)$ uncertainties into a small number of orthogonal modes for use in cosmological inference. Marginalizing over these modes leads to only a minor degradation in cosmological constraints. This analysis establishes the MagLim++ sample as a robust lens sample for precision cosmology with DES Y6 and provides a scalable framework for future surveys.

Giannini, G. [Chicago U., Astron. Astrophys. Ctr.;↗

Dark Energy Survey Year 6 Results: Redshift Calibration of the Weak Lensing Source Galaxies

Determining the distribution of redshifts for galaxies in wide-field photometric surveys is essential for robust cosmological studies of weak gravitational lensing. We present the methodology, calibrated redshift distributions, and uncertainties of the final Dark Energy Survey Year 6 (Y6) weak lensing galaxy data, divided into four redshift bins centered at $\langle z \rangle = [0.414, 0.538, 0.846, 1.157]$. We combine independent information from two methods on the full shape of redshift distributions: optical and near-infrared photometry within an improved Self-Organizing Map $p(z)$ (SOMPZ) framework, and cross-correlations with spectroscopic galaxy clustering measurements (WZ), which we demonstrate to be consistent both in terms of the redshift calibration itself and in terms of resulting cosmological constraints within 0.1$σ$. We describe the process used to produce an ensemble of redshift distributions that account for several known sources of uncertainty. Among these, imperfection in the calibration sample due to the lack of faint, representative spectra is the dominant factor. The final uncertainty on mean redshift in each bin is $σ_{\langle z\rangle} = [0.012, 0.008,0.009, 0.024]$. We ensure the robustness of the redshift distributions by leveraging new image simulations and a cross-check with galaxy shape information via the shear ratio (SR) method.

Yin, B. [Duke U.] (ORCID:0009000656049980)↗

The Power of DESI for Photometric Redshift Calibration: A Case Study with KiDS-1000

Accurate redshift estimates are a critical requirement for weak lensing surveys and one of the main uncertainties in constraints on dark energy and large-scale cosmic structure. In this paper, we study the potential to calibrate photometric redshift (photo-z) distributions for gravitational lensing using the Dark Energy Spectroscopic Instrument (DESI). Since beginning its science operations in 2021, DESI has collected more than 50 million redshifts, adding about one million monthly. In addition to its large-scale structure samples, DESI has also acquired over 256k high-quality spectroscopic redshifts (spec-zs) in the COSMOS and XMM and VVDS fields. This is already a factor of 3 larger than previous spec-z calibration compilations in these two regions. Here, we explore calibrating photo-zs for the subset of KiDS-1000 galaxies that fall into joint self-organizing map (SOM) cells overlapping the DESI COSMOS footprint using the DESI COSMOS observations. Estimating the redshift distribution in KiDS-1000 with the new DESI data, we find broad consistency with previously published results while also detecting differences in the mean redshift in some tomographic bins with an average shifts of Delta Mean(z) = -0.028 in the mean and Delta Median(z) = +0.011 in the median across tomographic bins. However, we also find that incompleteness per SOM cell, i.e., groups of galaxies with similar colors and magnitudes, can modify n(z) distributions. Finally, we comment on the fact that larger photometric catalogs, aligned with the DESI COSMOS and DESI XMM and VVDS footprints, would be needed to fully exploit the DESI dataset and would extend the coverage to nearly eight times the area of existing 9-band photometry.

Blanco, Diana [UC, Santa Cruz; UC, Santa Cruz, Ins↗

An initial exploration of Bayesian model calibration for estimating the composition of rocks and soils on Mars

The Mars Curiosity rover carries an instrument, ChemCam, designed to measure the composition of surface rocks and soil using laser-induced breakdown spectroscopy (LIBS). The measured spectra from this instrument must be analyzed to identify the component elements in the target sample, as well as their relative proportions. This process, which we call disaggregation, is complicated by so-called matrix effects, which describe nonlinear changes in the relative heights of emission lines as an unknown function of composition due to atomic interactions within the LIBS plasma. In this work, we explore the use of the plasma physics code ATOMIC, developed at Los Alamos National Laboratory, for the disaggregation task. ATOMIC has recently been used to model LIBS spectra and can robustly reproduce matrix effects from first principles. The ability of ATOMIC to predict LIBS spectra presents an exciting opportunity to perform disaggregation in a manner not yet tried in the LIBS community, namely via Bayesian model calibration. However, using it directly to solve our inverse problem is computationally intractable due to the large parameter space and the computation time required to produce a single output. Therefore, we also explore the use of emulators as a fast solution for this analysis. We discuss a proof of concept Gaussian process emulator for disaggregating two-element compounds of sodium and copper. The training and test datasets were simulated with ATOMIC using a Latin hypercube design. After testing the performance of the emulator, we successfully recover the composition of 25 test spectra with Bayesian model calibration.

97 MATHEMATICS AND COMPUTING↗

Quantitative interpretation of time-lapse seismic data at Farnsworth field unit: Rock physics modeling, and calibration of simulated time-lapse velocity responses

Here, this study investigates the contribution of fluid saturation variation to the time-lapse velocity response by performing fluid substitution modeling. The methodology is exemplified by the time-lapse seismic monitoring of carbon dioxide at Farnsworth field unit (FWU). In order to evaluate the fluid distribution in a matured oil reservoir, the Southwest Regional Partnership (SWP) acquired multiple vertical seismic profile (VSP) surveys at different times during the CO 2 –water alternatinggas (WAG) injection period. In this work, we present a thorough methodology for computing the elastic response of the saturated rock for different fluid saturations using a site-specific petro-elastic model (PEM). The output from the PEM was combined with results from a fluid compositional model to compute the seismic velocities at times corresponding to each VSP survey. To produce a calibrated simulated response, the measured time-lapse seismic velocities were integrated into the numerical simulation model. The mismatches between the predicted and measured time-lapse velocities were minimized through an iterative calibration process using a trained artificial neural network proxy (ANN) coupled with a particle swarm optimizer (PSO). Our study indicates that the hybrid optimization workflow can effectively perform the history matching. With an accurate prediction of the hydrodynamic properties, the migration of CO 2 within the subsurface was modeled by predicting the spatial velocity distribution for a radius of 305 m around the injection well. The technology demonstrated and the expertise gained from this study can guide similar CO 2 -WAG projects.

58 GEOSCIENCES↗

Calibration of elastoplastic constitutive model parameters from full-field data with automatic differentiation-based sensitivities

Here, we present a framework for calibration of parameters in elastoplastic constitutive models that is based on the use of automatic differentiation (AD). The model calibration problem is posed as a partial differential equation-constrained optimization problem where a finite element (FE) model of the coupled equilibrium equation and constitutive model evolution equations serves as the constraint. The objective function quantifies the mismatch between the displacement predicted by the FE model and full-field digital image correlation data, and the optimization problem is solved using gradient-based optimization algorithms. Forward and adjoint sensitivities are used to compute the gradient at considerably less cost than its calculation from finite difference approximations. Through the use of AD, we need only to write the constraints in terms of AD objects, where all of the derivatives required for the forward and inverse problems are obtained by appropriately seeding and evaluating these quantities. We present three numerical examples that verify the correctness of the gradient, demonstrate the AD approach's parallel computation capabilities via application to a large-scale FE model, and highlight the formulation's ease of extensibility to other classes of constitutive models.

42 ENGINEERING↗

Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests

The hot box test method has been applied to evaluate both the steady-state (U-value) and dynamic thermal properties of building envelopes. However, the high construction cost of full-scale hot box apparatus and the testing time required (usually several days) may prevent its wider adoption. To overcome the limitations of full-scale hot box tests, here we propose a novel method to evaluate the dynamic thermal performance of building envelope components using a small-scale calibrated hot box and scaled-down specimen. In this paper, the scaling relationships of thermal properties evaluated using a full-size specimen and a scaled-down specimen are established based on the Laplace transform of the heat transfer equations. In addition, dynamic thermal properties obtained from scaled-down experimental tests are compared to the values calculated by the EN ISO13768 (ISO) method. A small-scale hot box with a 355 mm × 355 mm metering area was constructed and calibrated to validate the correlations. Three scaled-down concrete sandwich wall panels were then tested and the scaling relationship was cross-validated using the experimental results, finite difference (FD) simulations, and the ISO method. The results indicate that the dynamic thermal properties obtained from a scaled-down hot box test can be correlated to its full-size counterpart when certain conditions are met. The scaled-down hot box test is demonstrated to be an effective yet economical alternative to a full-scale test with significantly reduced experimentation cost and turn-around time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibration of large neutron detection arrays using cosmic rays

Cosmic muons are used to calibrate the position, light output and the relative timing offset of the Large Area Neutron Array (LANA). Each 2 × 2 m 2 LANA wall consists of twenty-five horizontal neutron detection bars. Each bar is 2 m long with a cross-section of 6.35 × 7.62 cm 2 Pyrex container filled with NE-213 organic scintillation liquid. The average position and time resolution of a bar is found to be about 8 cm and 500 ps FWHM, respectively. Furthermore, our method provides an accurate, fast and convenient calibration of LANA that can be applied to general scintillation arrays without the use of radioactive sources or beams.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pyroelectric Heat Detection for Calibrated Measurement of Atomic Layer Deposition Reaction Heat

Atomic layer deposition (ALD) precursors and processes have been identified that enable the deposition of materials that span the periodic table. However, the detailed mechanisms, kinetics, thermodynamics, and complexities of even the most well-studied ALD half-reactions remain insufficiently resolved experimentally to test present computational hypotheses. In this work, a pyroelectric calorimeter is designed, implemented, calibrated, and electrically modeled to enable quantitative ALD reaction heat detection. The operation and response of three ALD calorimeter designs were evaluated for use as absolute ALD half-reaction heat detectors. The most effective design was calibrated in situ before being utilized to measure the heat generated by the reaction of trimethylaluminum with a hydroxylated alumina surface to produce 96 μJ/cm 2 over a reaction time of ~30 ms. With thermal and temporal resolutions down to 0.1 μJ/cm 2 and 50 ns, respectively, this sensitive and ultrafast probe is poised to improve our fundamental understanding of numerous ALD reaction mechanisms through quantitative comparison with first-principles computation predictions.

36 MATERIALS SCIENCE↗

Using Machine Learning to Generate a GISS ModelE Calibrated Physics Ensemble (CPE)

A neural network (NN) surrogate of the NASA GISS ModelE atmosphere (version E3) is trained on a perturbed parameter ensemble (PPE) spanning 45 physics parameters and 36 outputs. The NN is leveraged in a Markov Chain Monte Carlo (MCMC) Bayesian parameter inference framework to generate a second posterior constrained ensemble coined a “calibrated physics ensemble,” or CPE. The CPE members are characterized by diverse parameter combinations and are, by definition, close to top-of-atmosphere radiative balance, and must broadly agree with numerous hydrologic, energy cycle and radiative forcing metrics simultaneously. Global observations of numerous cloud, environment, and radiation properties (provided by global satellite products) are crucial for CPE generation. The inference framework explicitly accounts for discrepancies (or biases) in satellite products during CPE generation. We demonstrate that product discrepancies strongly impact calibration of important model parameter settings (e.g., convective plume entrainment rates; fall speed for cloud ice). Structural improvements new to E3 are retained across CPE members (e.g., stratocumulus simulation). Notably, the framework improved the simulation of shallow cumulus and Amazon rainfall while not degrading radiation fields, an upgrade that neither default parameters nor Latin Hypercube parameter searching achieved. Analyses of the initial PPE suggested several parameters were unimportant for output variation. However, many “unimportant” parameters were needed for CPE generation, a result that brings to the forefront how parameter importance should be determined in PPEs. From the CPE, two diverse 45-dimensional parameter configurations are retained to generate radiatively-balanced, auto-tuned atmospheres that were used in two E3 submissions to CMIP6.

54 ENVIRONMENTAL SCIENCES↗

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗