Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrification of residential and commercial buildings integrated with hybrid renewable energy systems: A techno-economic analysis

Here, this study assesses the techno-economic viability of city-scale building electrification, comparing a base case scenario with conventional HVAC systems to an electrified scenario with heat pump systems. EnergyPlus simulations reveal a 28% increase in annual electricity consumption in the electrified scenario, shifting the peak consumption from summer to winter with a 49% surge. Hybrid renewable energy systems (HRESs) are then evaluated using HOMER Pro, considering renewable penetration from 0% to 100%. The net present cost (NPC) of the base case and electrified scenarios range from $\$10.34$ to $\$24.38$ billion and $\$8.79$ to $\$50.31$ billion, respectively. Sensitivity analysis explores the impact of carbon tax, fuel price, and renewable subsidies on HRESs in the electrified scenario. Results indicate that applying a carbon tax up to $\$120$/tonne of CO 2 increases the optimum renewable fraction from 5% to 26%, while higher fuel prices and renewable subsidies further enhance the feasibility by shifting the optimum renewable fraction to 60% and 54%, respectively, demonstrating the interplay between economic factors and renewable integration in electrified urban contexts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Good practices for documenting AI-based studies on energy and buildings

Artificial intelligence has transformed building science research over the past decade, with applications spanning energy modeling, energy prediction, HVAC optimization and controls, fault detection, and occupancy modeling. However, many studies lack adequate documentation of datasets, algorithms, training procedures, and validation methods. Building science research faces additional challenges including inconsistent evaluation metrics, limited generalizability across building types, climates, and significant gaps between experimental studies and deployed systems. This communication provides practical guidance for good practices in documenting and publishing AI-based research following established standards from the computer science and machine learning communities. By adopting frameworks such as Datasheets for Datasets, Model Cards, and standardized reproducibility checklists, researchers can ensure their work meets the rigorous documentation standards necessary for reproducible, comparable, and impactful building science research.

Hong, Tianzhen [Lawrence Berkeley National Laborat↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Wireless Power Technology for Use in Electrochromic Window Retrofit Applications

Electrochromic (EC) windows, often referred to as smart windows, have the ability to adjust their tint in response to electrical signals, thereby controlling the amount of sunlight and heat entering a building. This dynamic modulation can lead to significant energy savings by reducing the reliance on artificial lighting and minimizing the load on heating, ventilation, and air conditioning (HVAC) systems. However, the widespread adoption of electrochromic window technology, especially in existing buildings, faces challenges, particularly concerning the installation cost associated with the need for electrical wiring to power and control the EC glass (tinting). In this project, GuRu Wireless demonstrated that it’s mmWave-based wireless power energy transfer technology can provide the necessary power for operation of electrochromic windows, wirelessly, and address the wiring challenges of electrochromic windows in retrofit applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

Commercial Building Stock Segmentation for Decarbonization Planning

This document discusses the development of a segmentation approach for the U.S. commercial building stock that is focused on identifying similarities that align with common decarbonization strategies. The resulting nine-segment approach primarily uses similarities in heating, ventilation, and air conditioning (HVAC) systems, service water heating systems, and presence of cooking equipment to separate buildings into categories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cloud-Control of Legacy Building Automation System: A case study

As Internet of Things devices and cloud-based platforms become more mature, Energy Management and Information Systems (EMIS) are increasingly gaining momentum in the building industry. In large commercial buildings, Fault-Detection and Diagnostic (FDD) and energy information systems (EIS) are now established technologies with tens of providers and thousands of deployment sites across North America. The new frontier for the EMIS technology is now represented by control systems that use advanced system optimization (ASO) methods to improve the operations of the HVAC system. Given the complexity of the integration of such systems with the existing building automation systems (BAS) and the higher risk involved with direct control of the HVAC, these systems are still emerging in the market. This paper presents the results of a project in which a start-up company partnered with a research institution to develop a cloud-based software EMIS solution and deployed it in a university campus in California. The software system included advanced sensing, data acquisition, storage and advanced control and analytics applications developed on top of the native BAS. The new platform controls ten buildings on the campus and the FDD and the ASO applications deployed on this platform were able to generate energy savings of up to 35% and 25% in certain buildings for each functionality respectively. Where the platform did not save energy, it improved building service (air quality). Lessons learned include the importance of collaborating with and training the building operators and evaluating whether the legacy system can work reliably with the new technology.

Prakash, Anand Krishnan↗

DSO+T: Integrated System Simulation (DSO+T Study: Volume 2)

This report summarizes an integrated co-simulation model used by the Distribution System Operator with Transactive (DSO+T) study to represent an electrical generation, delivery, and end-load systems for the purposes of assessing the viability and value proposition of transactive energy coordination of flexible assets versus a business-as-usual case. The integrated co-simulation model includes the bulk generation and transmission system, including the day-ahead and real-time scheduling and dispatch of thermal generators. Forty distribution system operators were modelled in detail, including tens of thousands of residential and commercial buildings and their flexible end-loads. These included HVAC systems, residential water heaters, electric vehicles, and stationary, behind-the-meter, batteries. Both wholesale market and end-load results for the business-as-usual case are presented and compared to actual ERCOT system data to assess the accuracy and representativeness of the resulting model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Room Return Path Sensitivity

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms. In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology–or layout–impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This report considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CAD-based Energy & Cost Models Prove Affordable Net Zero Energy Performance for WonderWindows + 24" On-center Framing

Windows are thermally the “weakest link” in the building envelope. Increasing the thermal resistance of windows can make buildings more energy efficient and reduce the cost of electricity needed for conditioning the building. The proper design and placement of framing can also help to reduce the thermal bridging that occurs near the window frame area. This study investigates the energy performance of multi-pane acrylic windows fitting 24" on-center framing. Initial parametric analysis is done for a single zone accessory dwelling unit (ADU). Then, an energy model was developed for three types of wood-framed buildings: townhomes, stacked flats and hotels. A whole building energy simulation is performed for each of these building types in hot-humid Houston, mixed-humid New York, and cold-humid Minneapolis climates. The results show up to a 39% reduction in heating, ventilation, and air-conditioning (HVAC) related electricity consumption for the cold climate compared to the Base case which has window and wall properties based on ASHRAE standard 90.1 2019. In the hot climate, a modest increase in electricity consumption was seen due to an increase in cooling electricity demand. The ADU achieved Net Zero Energy performance in all 3 Climate Zones despite having the highest exterior surface area-to-floor area ratio: the ADU also had the highest PV kW to floor area ratio compared to the other multi-story building types. The townhomes, hotel and stacked flats respectively met 73, 52 and 57 % of electrical use in Houston, 71, 48 and 56 % in New York, and 63, 40 and 53 % in Minneapolis from energy produced by rooftop solar. If 400 W solar panels are used instead of 320 W panel used for energy simulation, it is estimated that in the townhomes, hotel and stacked flats rooftop solar can meet 91, 65 and 71 % of electrical use in Houston; 89, 60 and 70% in New York, and 79, 50 and 66 % in Minneapolis. A preliminary evaluation of cost shows that such superior performance can potentially be achieved at less first cost with this 24"on-center solution than conventional construction. All the building types at the three locations used for simulation had net energy use intensity under 20 kBtu/sf/year with 320 W solar panel and under 17 kBtu/sf/year with 400 W solar panel. Further tailoring of building envelope R-values and window solar heat gain to particular Climate Zone locations for each building type shows promise in reducing the HVAC electricity use that comprises almost half of building energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Dataset 2024.1 Documentation

Public ResStock datasets provide credible, relevant, and accessible information on energy use and related non-energy metrics to a variety of stakeholders in the residential buildings space. The current public datasets include baseline building characteristics, timeseries (15-minute) energy consumption, and timeseries carbon emissions for the baseline (existing) U.S. housing stock and the U.S. housing stock with 10 "what-if" energy measure packages applied. This report documents a new public ResStock dataset to complement and build upon the existing public datasets. This dataset is specifically intended to be a resource for state and local decision-makers considering options for energy retrofits for their housing stock to reduce carbon emissions, energy use, and/or utility bills. These data consist of housing stock characteristics and modeled full-year energy consumption, carbon emission, energy bill, and energy burden data for the baseline U.S. housing stock as well as the U.S. housing stock with 260 "what-if" energy measure packages applied. These measure packages include measures related to the building envelope, appliances, pools and spas, lighting, water heating, and HVAC (including efficiency improvements and fuel switching with equipment at a range of performance levels) in a variety of combinations. This report provides methodology information on the generation of this dataset and serves as a key part of the dataset's public documentation.

buildings↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

State-of-the-art on research and applications of machine learning in the building life cycle

Fueled by big data, powerful and affordable computing resources, and advanced algorithms, machine learning has been explored and applied to buildings research for the past decades and has demonstrated its potential to enhance building performance. This study systematically surveyed how machine learning has been applied at different stages of building life cycle. By conducting a literature search on the Web of Knowledge platform, we found 9579 papers in this field and selected 153 papers for an in-depth review. The number of published papers is increasing year by year, with a focus on building design, operation, and control. However, no study was found using machine learning in building commissioning. There are successful pilot studies on fault detection and diagnosis of HVAC equipment and systems, load prediction, energy baseline estimate, load shape clustering, occupancy prediction, and learning occupant behaviors and energy use patterns. None of the existing studies were adopted broadly by the building industry, due to common challenges including (1) lack of large scale labeled data to train and validate the model, (2) lack of model transferability, which limits a model trained with one data-rich building to be used in another building with limited data, (3) lack of strong justification of costs and benefits of deploying machine learning, and (4) the performance might not be reliable and robust for the stated goals, as the method might work for some buildings but could not be generalized to others. Finally, findings from the study can inform future machine learning research to improve occupant comfort, energy efficiency, demand flexibility, and resilience of buildings, as well as to inspire young researchers in the field to explore multidisciplinary approaches that integrate building science, computing science, data science, and social science.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗