Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomic clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Whispering Gallery Mode Resonators as Optical Reference Cavities

Highly stabilized lasers are an increasingly valuable tool for metrology. For many applications, however, existing Fabry Perot systems are too bulky and cumbersome. We are investigating the use of miniature monolithic whispering gallery mode resonators as reference cavities for laser stabilization. We seek to exploit the benefit of small size and vibration resistance by suppressing thermally induced frequency fluctuations. We have theoretically investigated the viability of using a thin-film coating to achieve temperature compensation. We have experimentally investigated an active temperature stabilization scheme based on birefringence in a crystalline resonator. We also report progress of laser locking to the resonators.

optical frequency↗

Independent Panel Report for Technical Assessment of NASA and External Quantum Sensing Capabilities

Sensors based on quantum mechanical properties of electromagnetic radiation and matter offer unique capabilities and performance sometimes difficult to achieve using classical approaches. This report assesses the suitability of quantum sensing for current and future NASA needs, with a specific focus on NASA’s Science Mission Directorate (SMD). Measurement and sensing needs across NASA SMD are reviewed as a driver for the possible incorporation of existing quantum sensors into the NASA portfolio and the development of next-generation quantum sensors. A range of quantum sensing modalities is then described and the current state of the art for each sensor is presented. Current research and development activities on quantum sensing within NASA are compared with the range of activities ongoing throughout the broader scientific community, both within the United States and internationally. In conclusion, there is considerable advantage to be gained by NASA from quantum sensors through the growth of internal programs and collaboration with outside entities.

Quantum Sensing↗

Appendix A: The Impact of the HP 5071A on International Atomic Time

The international clock ensemble, which contributes to the generation of International Atomic Time (TAI and UTC) has improved dramatically over the last few years. The main change has been the introduction of a significant number of HP 5071A clocks. Of the 313 clocks contributing to TAI/UTC during 1994, 94 of these were HP 5071As. The environmental insensitivity of the HP 5071A clocks is more than an order of magnitude better than that of previously contributing clocks. This environmental insensitivity translates to outstanding long-term stability - with a typical flicker floor of a few x10(sup -15). in addition, there are now several hydrogen masers with cavity tuning contributing to TAI/UTC. These not only have outstanding short-term stability, but comparatively low frequency drifts and excellent intermediate-type frequency stability. By analyzing data available from the international ensemble, we have obtained two important results. First the frequency stability obtainable with an optimum algorithm is about 10(sup -15) for both the intermediate and long-term regions. It could be as good in the short-term (if time transfer measurement instabilities were reduced sufficiently. Second, with cooperation, this performance can be made available on an international basis in near real time. The recent enhancements in the contributing clocks are already providing a significant improvement in the accuracy with which UTC is made available to the world from several of the national timing centers, such as the National Institute for Standards and Technology (NIST) and the US Naval Observatory (USNO).

Allan, David W.↗

Atomic frequency standard relativistic Doppler shift experiment

An experiment has been performed to measure possible space anisotropy as it would effect the frequency of a cesium atomic beam standard clock in a laboratory on earth due to motion relative to external coordinate frames. The cesium frequency was measured as a function of orientation with respect to an atomic hydrogen maser standard. Over a period of 34 days 101 measurements were made. The results are consistent with a conclusion that no general orientation dependance attributable to spacial anisotropy was observed. It is shown that both the airplane clock results, and the null results for the atomic beam clock, are consistent with Einstein general or special relativity, or with the Lorentz transformations alone.

Peters, H. E.↗

Atomic Coherence of 2 Minutes and Instability of 1.5 × 10 −18 at 1 s in a Wannier-Stark Lattice Clock

We explore the limits of atomic coherence and measurement precision in a 87 Sr optical lattice clock. We perform a detailed characterization of key effects, including lattice Raman scattering and atomic collisions in a shallow lattice configuration, determining a 174(28) s 3 𝑃 0 clock state lifetime. Investigation of atomic coherence across a range of lattice depths and atomic densities reveals decoherence mechanisms related to photon scattering and atomic interaction. At a reduced density, we observe a coherence time of 118(9) s, approaching the fundamental limit set by spontaneous emission. Guided by this coherence understanding, we demonstrate a clock instability for an atomic ensemble of 1.5 × 10 −18 at 1 s in fractional frequency units. Our results are important for further advancing the state of the art of an optical lattice clock for fundamental physics applications.

atomic, optical, & lattice clocks↗

Clock Technology Development in the Laser Cooling and Atomic Physics (LCAP) Program

This paper presents the Laser Cooling and Atomic Physics (LCAP) program. It focuses on clock technology development. The topics include: 1) Overview of LCAP Flight Projects; 2) Space Clock 101; 3) Physics with Clocks in microgravity; 4) Space Clock Challenges; 5) LCAP Timeline; 6) International Space Station (ISS) Science Platforms; 7) ISS Express Rack; 8) Space Qualification of Components; 9) Laser Configuration; 10) Clock Rate Comparisons: GPS Carrier Phase Frequency Transfer; and 11) ISS Model Views. This paper is presented in viewgraph form.

Seidel, Dave↗

The Tidal Clock Effects of the Lunisolar Gravitational Field and the Earth’s Tidal Deformation

State-of-the-art atomic and optical clocks have the great potential to precisely test fundamental physical assumptions and enhance our understanding of nature. Their widespread applications require us to rigorously deduce the relativistic frequency shift in the framework of general relativity. One interesting question for clocks is tidal field effect which contains variously periodic variations. By introducing tidally deformed Earth, the general algorithms for clock and frequency comparisons are derived. We investigate the effects of external gravitational bodies and Earth’s tidal deformation on the ground- and space-based clocks. The orbital elements of satellite and locations of laboratory are introduced for corresponding clocks, in which the secular and long-period terms and short-period terms are subsequently presented. These effects called tidal clock effects produce the non-negligible contributions in the modern clock experiments and can be directly evaluated from our parameterized formulas. In addition, we also demonstrate for tidal clock effects the position and distance dependences, as well as periodicity. These tidal effects and dependences can provide valuable information for the clock comparison experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Test of an orbiting hydrogen maser clock system using laser time transfer

We describe a joint Smithsonian Astrophysical Laboratory/National Aeronautics and Space Administration (SAO/NASA) program for flight testing a atomic hydrogen maser clock system designed for long-term operation in space. The clock system will be carried by a shuttle-launched EURECA spacecraft. Comparisons with earth clocks to measure the clock's long-term frequency stability (tau = 10(exp 4) seconds) will be made using laser time transfer from existing NASA laser tracking stations. We describe the design of the maser clock and its control systems, and the laser timing technique. We describe the precision of station time synchronization and the limitations in the comparison between the earth and space time scales owing to gravitational and relativistic effects. We will explore the implications of determining the spacecraft's location by an on-board Global Position System (GPS) receiver, and of using microwave techniques for time and frequency transfer.

Vessot, Robert F. C.↗

Los Alamos - A Short History

At 5:45 am on the morning of July 16, 1945, the world’s first atomic bomb exploded over a remote section of the southern New Mexican desert known as the Jornada del Muerto, the Journey of Death. Three weeks later, the atomic bombs known as Little Boy and Fat Man brought World War II to an end. Working literally around the clock, these first atomic bombs were designed and built in just thirty months by scientists working at a secret scientific laboratory in the mountains of New Mexico known by its codename, Project Y, better known to the world as Los Alamos.

99 GENERAL AND MISCELLANEOUS↗

An open source digital servo for atomic, molecular, and optical physics experiments

We describe a general purpose digital servo optimized for feedback control of lasers in atomic, molecular, and optical physics experiments. The servo is capable of feedback bandwidths up to roughly 1 MHz (limited by the 320 ns total latency); loop filter shapes up to fifth order; multiple-input, multiple-output control; and automatic lock acquisition. The configuration of the servo is controlled via a graphical user interface, which also provides a rudimentary software oscilloscope and tools for measurement of system transfer functions. We illustrate the functionality of the digital servo by describing its use in two example scenarios: frequency control of the laser used to probe the narrow clock transition of {sup 27}Al{sup +} in an optical atomic clock, and length control of a cavity used for resonant frequency doubling of a laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Raman − Ramsey pulsed excitation of coherent population trapping resonances in a {sup 87}Rb cell with a buffer gas

We report the results of experimental investigation of the Raman – Ramsey method of pulsed excitation of coherent population trapping (CPT) resonances in a rubidium vapour cell filled with a mixture of Ar and Ne buffer gases. For the development of compact quantum microwave frequency standards, this method is an alternative to the pulsed optical pumping method recently implemented using the same rubidium cell. Both methods have advantages over the traditional double radio-optical resonance technique, the main of which is the substantial suppression of the light shift of the clock transition frequency, since the evolution of the coherence of atomic states forming the clock transition occurs in the absence of laser radiation in the cell. The narrow (110 – 240 Hz) Raman – Ramsey resonances are obtained using the scheme of pulsed excitation of CPT resonances on the D{sub 1} lines of the {sup 87}Rb atom with the same linear (lin||lin) polarisations of the bichromatic laser radiation components. The process of optimising the central fringe linewidth, its contrast, and the linewidth-to-contrast ratio is described. The magnetic dependence of the Raman – Ramsey line central fringe linewidth is experimentally investigated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser induced asymmetry and inhomogeneous broadening of the microwave lineshape of a gas cell atomic frequency standard

The possibility of replacing the RF discharge lamp in a rubidium gas cell clock with a single mode laser diode is addressed. Since the short term stability of the rubidium frequency standard is limited by the shot noise of the photodetector, an increased signal-to-noise ratio due to more efficient laser diode optical pumping might improve the short term performance. Because the emission wavelength of the laser diode can be tuned, improved long term performance could be gained through the control of the light shift effect. However, due to the nature of the gas cell frequency standard, various physical phenomena are strongly coupled in their effect on the frequency output, and thus careful consideration must be given to any change in one parameter because of its interrelation with other parameters. Some investigations concerning the coupled effect of the optical and microwave fields in the rubidium atomic clock are reported. It is shown that this type of coupling is an important consideration for any attempt to incorporate a laser diode into a gas cell clock.

Camparo, J. C.↗

Detection of the clock transition (1.14 μm) in ultra-cold thulium atoms

The magnetic dipole transition between fine structure sublevels of the ground state of thulium atom 4f{sup 13}({sup 2}F{sup o})6s{sup 2} has been directly excited in a cloud of ultra-cold atoms by a frequency-stabilised laser. This transition at the wavelength λ = 1.14 μm is planned to be used as the clock one in an optical frequency reference on laser-cooled thulium atoms. (extreme light fields and their applications)

74 ATOMIC AND MOLECULAR PHYSICS↗

Compensation of residual amplitude modulation fluctuations in an optoelectronic system for laser radiation frequency stabilisation

Fluctuations of residual amplitude modulation in a scheme of laser frequency stabilisation by a Fabry – Perot cavity reduce the frequency stability of the laser systems intended for interrogating clock transitions of atoms and ions. The dependences of the residual amplitude modulation on a temperature of the waveguide-based electro-optical modulator used for modulating the radiation phase and on polarisation of the radiation are measured. The parameters are found, at which the influence of the residual amplitude modulation on the frequency stability is minimal. A system for active compensation is created, which reduces the contribution of fluctuations of residual amplitude modulation to the instability down to 2.1 × 10{sup −16}, which makes it possible to reach the thermal noise limit of a silicon cryogenic cavity. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Precision Time Transfer in Space with a Hydrogen Maser on MIR

An atomic hydrogen maser clock system designed for long term operation in space will be installed on the Russian space station Mir, in late 1997. The H-maser's frequency stability will be measured using pulsed laser time transfer techniques. Daily time comparisons made with a precision of better than 100 picoseconds will allow an assessment of the long term stability of the space maser at a level on the order of 1 part in 10(sup 15) or better. Laser pulse arrival times at the spacecraft will be recorded with a resolution of 10 picoseconds relative to the space clock's time scale. Cube corner reflectors will reflect the pulses back to the Earth laser station to determine the propagation delay and enable comparison with the Earth-based time scale. Data for relativistic and gravitational frequency corrections will be obtained from a Global Positioning System (GPS) receiver.

Mattison, Edward M.↗

Repetitive Interrogation of 2-Level Quantum Systems

Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

Rabi interrogation↗

Robust Mølmer-Sørensen gate for neutral atoms using rapid adiabatic Rydberg dressing

The Rydberg blockade mechanism is now routinely considered for entangling qubits encoded in clock states of neutral atoms. Challenges towards implementing entangling gates with high fidelity include errors due to thermal motion of atoms, laser amplitude inhomogeneities, and imperfect Rydberg blockade. Here, we show that adiabatic rapid passage by Rydberg dressing provides a mechanism for implementing two-qubit entangling gates by accumulating phases that are robust to these imperfections. We find that the typical error in implementing a two-qubit gate, such as the controlled phase gate, is dominated by errors in the single-atom light shift, and that this can be easily corrected using adiabatic dressing interleaved with a simple spin echo sequence. This results in a two-qubit Mølmer-Sørensen gate. A gate fidelity ~ 0.995 is achievable with modest experimental parameters and a path to higher fidelities is possible for Rydberg states in atoms with a stronger blockade, longer lifetimes, and larger Rabi frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗