Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “actual”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Tensor network investigation of the double layer Kagome compound Ca 10 Cr 7 O 28

Quantum spin liquids are exotic quantum phases of matter that do not order even at zero temperature. While there are several toy models and simple Hamiltonians that could host a quantum spin liquid as their ground state, it is very rare to find actual, realistic materials that exhibit their properties. At the same time, the classical simulation of such instances of strongly correlated systems is intricate and reliable methods are scarce. Here, in this work, we investigate the quantum magnet Ca 10 Cr 7 O 28 that has recently been discovered to exhibit properties of a quantum spin liquid in inelastic neutron scattering experiments. This compound has a distorted bilayer Kagome lattice crystal structure consisting of Cr 5+ ions with spin- moments. Coincidentally, the lattice structure renders a tensor network algorithm in 2D applicable that can be seen as a new variant of a projected entangled simplex state algorithm in the thermodynamic limit. In this first numerical investigation of this material that takes into account genuine quantum correlations, good agreement with the experimental findings is found. Our study contributes to uplifting tensor networks from conceptual tools to methods to describe real two-dimensional quantum materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the generalised equipartition law

We observe that the so-called Generalised Equipartition Law for hamiltonian systems is actually valid only under specific hypotheses – unfortunately omitted in some textbooks – which limit its applicability when dealing with nonlinear systems. We introduce a new coordinate-independent generalisation which overcomes this problem and can be applied to a larger set of functions. A simple example of application is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A most misunderstood conditionally-solvable quantum-mechanical model

Highlights: • The Schrödinger equation for some quantum-mechanical models is separable in cylindrical coordinates. • The radial equation exhibits harmonic, linear and Coulomb-like interactions. • The Frobenius method leads to three-term recurrence relations. • Some particular energies are obtained from truncation of the recurrence relation. • Many authors misunderstood these results. In this paper we show that several authors have derived wrong physical conclusions from a gross misunderstanding of the exact eigenvalues and eigenfunctions of a conditionally-solvable quantum-mechanical model. It consists of an eigenvalue equation with seemingly Coulomb, linear and harmonic terms. Here we compare the results derived by those authors with the actual eigenvalues of the models calculated by means of the Ritz variational method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of wind power scenario creation methods for stochastic power systems operations

Probabilistic scenarios of renewable energy production, such as wind, have been gaining popularity for use in stochastic variants of power systems operations scheduling problems, allowing for optimal decision-making under uncertainty. The quality of the scenarios has a direct impact on the value of the resulting decisions, but until now, methods for creating scenarios have not been compared under realistic operational conditions. Here, we compare the quality of scenario sets created using three different methods, based on a simulated re-enactment of stochastic day-ahead unit commitment and subsequent dispatch for a realistic test system. We create scenarios using a dataset of forecasted and actual wind power values, scaled to evaluate the effects of increasing wind penetration levels. We show that the choice of scenario set can significantly impact system operating cost, renewable energy use, and the ability of the system to meet demand. This result has implications for the ability of system operators to efficiently integrate renewable production into their day-ahead planning, highlighting the need for the use of performance-based assessments for scenario evaluation.

17 WIND ENERGY↗

The importance of maldistribution matching for thermal performance of compact heat exchangers

Compact heat exchangers have gained increased attention in recent years, particularly in demanding applications where high temperatures, high pressures, and/or high power densities are required. For decades, the heat exchanger (HX) community believes that flow maldistribution is a key factor for HX effectiveness, that is, reducing the degree of flow maldistribution (MALD) can help increase the HX effectiveness. Therefore, significant efforts have been devoted in the past to optimizing the header geometry to minimize flow maldistribution. This work was initially motivated by this, and the original goal was to figure out a HX header design with the lowest maldistribution. However, by systematically constructing a comprehensive maldistribution matrix, the analysis revealed that the HX effectiveness is not actually determined by the MALD, but instead dominated by the degree of maldistribution mismatch (MISM). This conclusion was also theoretically generalized, which indicated that matching of the local heat capacity rate is key for achieving maximum performance. The MISM provides a local means of tracking this information, while the MALD only provides a global approximation of the maldistribution itself. With this new perspective, flow maldistribution needs not necessarily be avoided, but instead matched between two fluid streams, to improve the HX performance. We demonstrated that by carefully designing the header geometry to match the velocity profiles of the two fluids in a 2 MW PCHE with molten salt and supercritical carbon dioxide (sCO2) as the heat transfer fluids, the HX could achieve a higher effectiveness even when the maldistribution increased. Finally, a technoeconomic study using a CSP system as an example revealed that the use of this new HX design paradigm could result in CSP capital cost savings as large as 16.6%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating capacity credit sensitivity to reliability metrics and computational methodologies

Assigning capacity value to renewable energy sources (RES) is a challenge faced in planning their integration with the grid. The difficulties stem from the natural characteristics of variability and intermittency of wind and solar sources. The capacity credit (CC) analysis evaluates the system’s actual power output compared with a constant capacity generator, i.e., conventional generator and determines an effective capacity to use for planning and operation. Herein this paper presents different factors that could affect the CC of a system. Two methods are proposed to determine the CC, namely equivalent firm capacity (EFC) and effective load carrying capability (ELCC). Since these methods are based on satisfying reliability criteria, daily loss of load expectation (LOLE), hourly loss of load (LOLH), and expected energy not served (EENS) have been employed as indices. To obtain the CC value, both methods apply two techniques: traditional and optimization. Genetic algorithm (GA) is the optimization approach used in this paper. Then, this work compares the two techniques and shows the superior performance of the optimization approach. Two hybrid systems, stand-alone (SA) and grid-connected (GC) modes, are proposed and used as case studies. The hybrid systems consist of photovoltaic (PV), wind turbine (WT), and battery energy storage system (BESS). In this work, three different scenarios are used to compare capacity credit: system as a whole, only wind, and no batteries. Finally, sensitivity analysis is carried out to examine the impact of varying the wind speed, solar irradiation, and load. It is demonstrated that the choice of reliability index plays an important role in determining the capacity credit and it is shown that EENS is a more comprehensive and consistent index of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Analyzing at-scale distribution grid response to extreme temperatures

Threats against power grids continue to increase, as extreme weather conditions and natural disasters (extreme events) become more frequent. Hence, there is a need for the simulation and modeling of power grids to reflect realistic conditions during extreme events conditions, especially distribution systems. Herein, this paper presents a modeling and simulation platform for electric distribution grids which can estimate overall power demand during extreme weather conditions. The presented platform's efficacy is shown by demonstrating estimation of electrical demand for 1) Electricity Reliability Council of Texas (ERCOT) during winter storm Uri in 2021, and 2) alternative hypothetical scenarios of integrating Distributed Energy Resources (DERs), weatherization, and load electrification. In comparing to the actual demand served by ERCOT during the winter storm Uri of 2021, the proposed platform estimates approximately 34 GW of peak capacity deficit. These numbers are consistent with state-of-the-art prediction results published in the literature. For the case of the future electrification of heating loads, peak capacity of 78 GW (124% increase) is estimated, which would be reduced to 47 GW (38% increase) with the adoption of efficient heating appliances and improved thermal insulation. Integrating distributed solar PV and storage into the grid causes improvement in the local energy utilization and hence reduces the potential unmet energy by 31% and 40%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of system parameters and geospatial variables on the reliability of residential systems with PV and energy storage

A reliable power supply is the foundation of modern society, enabling technologies used to function within a society. Residential systems are places where the end users directly consume power, enabling technologies to sustain life. With the emergence of behind-the-meter resources, the end-users have some control over power supply reliability. The intermittency and variability of these resources impact residential system reliability. In this work, we study the reliability performance of a grid-supplemented residential system with behind-the-meter Distributed Energy Resources(DER) subject to various system parameters and geospatial variables. We propose a multistate reliability model for the behind-the-meter microinverter-based Photo Voltaic (PV) system and integrated inverter-based energy storage (ES) system. A sequential Monte Carlo method is then presented to evaluate the reliability indices for the residential system with behind-the-meter DERs as the main supply and the grid as the backup. The sequential Monte Carlo method is used to analyze the reliability performance of the residential model at the top 100 populous counties of the United States, where actual load and solar irradiance data at the counties is used. In the analysis, the sensitivity of indices to system parameters such as DER size and the sensitivity of the indices to climate zone and gross horizontal irradiation (GHI), which affects the load conditions and the PV output of the residential system, is performed. The analysis results show that the system parameters and the geospatial variables significantly impact the residential system’s reliability. The insights from this analysis will be of immense value to the distribution system planners to provide zone-specific guidelines for DER system sizing and toward the evolution of utility business models. Finally, the methodology developed can be used to extend the analysis to other locations.

14 SOLAR ENERGY↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive cold-load pickup considerations in 2-stage microgrid unit commitment for enhancing microgrid resilience

In an extended main grid outage spanning multiple days, load shedding serves as a critical mechanism for islanded microgrids to maintain essential power and energy reserves that are indispensable for fulfilling reliability and resiliency mandates. However, using load shedding for such purposes leads to increasing occurrence of cold load pickup (CLPU) events. Here, this study presents an innovative adaptive CLPU model that introduces a method for determining and incorporating parameters related to CLPU power and energy requirements into a two-stage microgrid unit commitment (MGUC) algorithm. In contrast to the traditional fixed-CLPU-curve approach, this model calculates CLPU duration, power, and energy demands by considering outage durations and ambient temperature variations within the MGUC process. By integrating the adaptive CLPU model into the MGUC problem formulation, it allows for the optimal allocation of energy resources throughout the entire scheduling horizon to fulfill the CLPU requirements when scheduling multiple CLPU events. The performance of the enhanced MGUC algorithm considering CLPU needs is assessed using actual load and photovoltaic (PV) data. Simulation results demonstrate significant improvements in dispatch optimality evaluated by the amount of load served, customer comfort, energy storage operation, and adherence to energy schedules. These enhancements collectively contribute to reliable and resilient microgrid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An iterative bidirectional gradient boosting approach for CVR baseline estimation

Here this paper presents a novel Iterative Bidirectional Gradient Boosting Model (IBi-GBM) for estimating the baseline of Conservation Voltage Reduction (CVR) programs. In contrast to many existing methods, we treat CVR baseline estimation as a missing data retrieval problem. The approach involves dividing the load and its corresponding temperature profiles into three periods: pre-CVR, CVR, and post-CVR. To restore the missing load profile during the CVR period, the method employs a three-step process. First, a forward-pass GBM is executed using data from the pre-CVR period as inputs. Subsequently, a backward-pass GBM is applied using data from the post-CVR period. The two restored load profiles are reconciled, considering pre-calculated weights derived from forecasting accuracy, and only the leftmost and rightmost points are retained. The newly restored points are then included as inputs for the subsequent iteration. This iterative procedure continues until the original load data in the CVR period is fully restored. We develop IBi-GBM using actual smart meter and Supervisory Control and Data Acquisition (SCADA) data. Our results demonstrate that IBi-GBM exhibits robust performance across various data resolutions and in different seasons and outperforms existing methods by achieving a 1-2% reduction in normalized Root Mean Square Error (nRMSE).

42 ENGINEERING↗

Power generation-cooling water Nexus: Impacts of cooling water shortage on power system operation - a simulation case study in Illinois, U.S

Cooling water shortage, frequently attributed to drought and heat waves, poses a significant threat to the operations of thermoelectric power plants and further poses a challenge for the entire power system and environmental stakeholders. Recognizing the critical nexus between power generation and cooling water availability and the potential ability of power generations to adjust generation schedules during cooling water shortages, this paper introduces a security-constrained unit commitment and economic dispatch model considering water-energy nexus. In specific, the model is augmented with a unit-level cooling water requirement (CWR) model and multi-level cooling water availability (CWA) constraints. The unit-level CWR model quantifies the cooling water withdrawal per MWh of power generation, taking into account factors such as thermoelectric generation technologies, cooling system technologies, and environmental parameters. The multi-level CWA constraints incorporate pump-level, plant-level, watershed-level, and forced minimum power constraints, utilizing data derived from actual-based cooling water shortage scenarios. Using a simulation case study in Illinois, United States, this research examines the reliability, economic, and environmental implications of cooling water shortages on power system operations. The results show that Illinois may experience 10-15% daily load curtailment and severe congestion between certain regions from the east to central during cooling water shortages, while once-through and wet-tower units experience a 52% and 17% reduction in power generation. In conclusion, overall cooling water withdrawal decreases by 24-38% as severity intensifies.

Cooling water shortage↗

Development of typical solar years and typical wind years for efficient assessment of renewable energy systems across the U.S.

Weather data plays a critical role in renewable energy analysis. Compared to using multiple Actual Meteorological Years, simulations using a single typical year require significantly fewer computational resources. Previous efforts to create typical weather datasets for renewable energy analysis either lack justified or optimized strategies for selecting and weighting different weather parameters or are limited to a few specific locations. Here, in this study, we developed a dataset comprising Typical Solar Years (TSYs) and Typical Wind Years (TWYs) for over 2000 locations across the U.S., based on data from NASA's POWER project. The strategies for creating TSYs and TWYs were optimized based on the simulated outputs of various PV systems and wind turbines in 16 representative cities. This dataset provides an efficient means for the rapid evaluation and optimization of renewable energy systems throughout the entire U.S. Additionally, the optimal strategies identified in this study can be directly applied to create near-optimal TSYs and TWYs for most locations worldwide. However, readers can also employ the optimization approach presented in this work to develop optimal strategies tailored for particular regions.

NASA POWER↗

An empirical analysis of supply offers in the ERCOT operating reserves markets

Here, this paper seeks to improve theoretical and empirical understanding of supplier dynamics in wholesale markets for operating reserves, which have been understudied compared to energy markets. We begin by identifying several economic factors that unit owners may consider when submitting offers into operating reserves auctions in two-stage, co-optimized markets common across much of North America. Next, we analyze historical offer data from the Electric Reliability Council of Texas (ERCOT) market to assess whether actual reserve market behavior aligns with expectations based on economic theory, as well as with commonly used assumptions in electricity market modeling efforts. We find that the aggregate supply of operating reserves in ERCOT varies meaningfully over time, becoming more expensive during summer afternoons, which is consistent with theoretical expectations but contradicts the typical modeling assumption of temporally invariant reserve offers. Analysis of offers made by individual units uncovers additional insights, such as the existence of large offer pattern differences by unit owner and the tendency of battery storage units to submit very low offer prices. We conclude by discussing how our findings can be integrated into electricity market modeling assumptions to improve alignment with observed operating reserve offer inputs and pricing outcomes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

UrbanPop: A spatial microsimulation framework for exploring demographic influences on human dynamics

Ensuring the social equity of planning measures in social systems requires an understanding of human dynamics, particularly how individual relationships, activities, and interactions intersect with individual needs. Spatial microsimulation models (SMSMs) support planning for human security goals by representing human dynamics through realistic, georeferenced synthetic populations, that a) provide a complete representation of social systems while b) also protecting individual privacy. In this paper, we present UrbanPop, an open and reproducible SMSM framework for analysis of human dynamics with high spatial, temporal, and demographic resolution. UrbanPop creates synthetic populations of demographically detailed worker and student agents, positioning them first at probable nighttime locations (home), then moving them to probable daytime locations (work/school). Summary aggregations of these populations match the granular detail available at the census block group level in the American Community Survey Summary File (SF), providing realistic approximations of the actual population. UrbanPop users can select particular demographic traits important in their application, resulting in a highly tailored agent population. We first lay out UrbanPop's baseline methodology, including population synthesis, activity modeling, and diagnostics, then demonstrate these capabilities by developing case studies of shifting population distributions and high-risk populations in Knox County, TN during the global COVID-19 pandemic.

60 APPLIED LIFE SCIENCES↗

Experimental and computational investigations on the SO 2 poisoning of (La 0.8 Sr 0.2 ) 0.95 MnO 3 cathode materials

To study the formation of detrimental phases under the sulfur gas impurity to the long-term degradation in the LSM cathode material, the classic cathode material, (La 0.8 Sr 0.2 ) 0.95 MnO 3 (LSM), was prepared, sintered, and annealed at 800, 900, and 1000°C in the sulfur-containing atmospheres, respectively. Through X-Ray Diffraction (XRD), Scanning Electron Microscope (SEM), and Transmission electron microscopy (TEM) techniques, as well as the CALPHAD (Computer Coupling of Phase Diagrams and Thermochemistry) methodology, the secondary phases, especially the detrimental ones, under different conditions were predicted and experimentally verified correspondingly. Furthermore, sulfur poisoning results indicate that the accelerated tests might have degradation mechanisms different from actual operation conditions. More importantly, comprehensive comparisons among various impurity-containing conditions were also made to recommend better operation parameters.

36 MATERIALS SCIENCE↗